Skip to main content

2017 | OriginalPaper | Buchkapitel

Control of Pneumatic Actuators with Long Transmission Lines for Rehabilitation in MRI

verfasst von : Melih Turkseven, Jun Ueda

Erschienen in: 2016 International Symposium on Experimental Robotics

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This study presents methods for understanding, modeling and control of tele-operated pneumatic actuators for rehabilitation in Magnetic Resonance Imaging (MRI). Pneumatic actuators have excellent MRI-compatibility as opposed to conventional electro-mechanical systems; however, the actuator and the system drivers cannot be co-located due to the MRI-compatibility requirements. The actuators are driven via long transmission lines, which affect the system dynamics significantly. Methods provided in this work produced accurate pressure estimation and control by accounting for the pressure dynamics in the lines, which has been neglected by previous work in this area. The effectiveness of the presented modeling and control methods were demonstrated on tele-operation test setups. This study also includes the design of necessary system components for the developed algorithms. An MRI-compatible optical sensor was developed for force feedback and its design was analyzed for high precision.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Elmasry, A., Liermann, M.: Passive pneumatic teleoperation system. In: ASME/BATH 2013 Symposium on Fluid Power and Motion Control, pp. V001T01A040-V001T01A040. American Society of Mechanical Engineers (2013) Elmasry, A., Liermann, M.: Passive pneumatic teleoperation system. In: ASME/BATH 2013 Symposium on Fluid Power and Motion Control, pp. V001T01A040-V001T01A040. American Society of Mechanical Engineers (2013)
2.
Zurück zum Zitat Gassert, R., Burdet, E., Chinzei, K.: Opportunities and challenges in MR-compatible robotics. IEEE Eng. Med. Biol. Mag. 27(3), 15–22 (2008)CrossRef Gassert, R., Burdet, E., Chinzei, K.: Opportunities and challenges in MR-compatible robotics. IEEE Eng. Med. Biol. Mag. 27(3), 15–22 (2008)CrossRef
3.
Zurück zum Zitat Gulati, N., Barth, E.: A globally stable, load-independent pressure observer for the servo control of pneumatic actuators. IEEE/ASME Trans. Mechatron. 14(3), 295–306 (2009)CrossRef Gulati, N., Barth, E.: A globally stable, load-independent pressure observer for the servo control of pneumatic actuators. IEEE/ASME Trans. Mechatron. 14(3), 295–306 (2009)CrossRef
4.
Zurück zum Zitat Krichel, S.V., Sawodny, O.: Non-linear friction modelling and simulation of long pneumatic transmission lines. Math. Comput. Model. Dyn. Syst. 20(1), 23–44 (2014)CrossRefMATH Krichel, S.V., Sawodny, O.: Non-linear friction modelling and simulation of long pneumatic transmission lines. Math. Comput. Model. Dyn. Syst. 20(1), 23–44 (2014)CrossRefMATH
5.
Zurück zum Zitat Li, J., Kawashima, K., Fujita, T., Kagawa, T.: Control design of a pneumatic cylinder with distributed model of pipelines. Precis. Eng. 37(4), 880–887 (2013)CrossRef Li, J., Kawashima, K., Fujita, T., Kagawa, T.: Control design of a pneumatic cylinder with distributed model of pipelines. Precis. Eng. 37(4), 880–887 (2013)CrossRef
6.
Zurück zum Zitat Sergi, F., Chawda, V., OMalley, M.K.: Interaction control of a non-backdriveable MR-compatible actuator through series elasticity. In: ASME 2013 Dynamic Systems and Control Conference, pp. V002T27A002-V002T27A002. American Society of Mechanical Engineers (2013) Sergi, F., Chawda, V., OMalley, M.K.: Interaction control of a non-backdriveable MR-compatible actuator through series elasticity. In: ASME 2013 Dynamic Systems and Control Conference, pp. V002T27A002-V002T27A002. American Society of Mechanical Engineers (2013)
7.
Zurück zum Zitat Turkseven, M., Ueda, J.: Design of an MRI compatible haptic interface. In: 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 2139–2144. IEEE (2011) Turkseven, M., Ueda, J.: Design of an MRI compatible haptic interface. In: 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 2139–2144. IEEE (2011)
8.
Zurück zum Zitat Turkseven, M., Ueda, J.: Analysis of an MRI compatible force sensor for sensitivity and precision. IEEE Sens. J. 13(2), 476–486 (2013)CrossRef Turkseven, M., Ueda, J.: Analysis of an MRI compatible force sensor for sensitivity and precision. IEEE Sens. J. 13(2), 476–486 (2013)CrossRef
9.
Zurück zum Zitat Turkseven, M., Ueda, J.: An asymptotically stable pressure observer based on load and displacement sensing for pneumatic actuators with long transmission lines. IEEE Trans. Mechatron. (2015) Turkseven, M., Ueda, J.: An asymptotically stable pressure observer based on load and displacement sensing for pneumatic actuators with long transmission lines. IEEE Trans. Mechatron. (2015)
10.
Zurück zum Zitat Yang, B., Tan, U.-X., McMillan, A., Gullapalli, R., Desai, J.: Design and control of a 1-dof MRI-compatible pneumatically actuated robot with long transmission lines. IEEE/ASME Trans. Mechatron. 16(6), 1040–1048 (2011)CrossRef Yang, B., Tan, U.-X., McMillan, A., Gullapalli, R., Desai, J.: Design and control of a 1-dof MRI-compatible pneumatically actuated robot with long transmission lines. IEEE/ASME Trans. Mechatron. 16(6), 1040–1048 (2011)CrossRef
11.
Zurück zum Zitat Yu, N., Hollnagel, C., Blickenstorfer, A., Kollias, S.S., Riener, R.: Comparison of MRI-compatible mechatronic systems with hydrodynamic and pneumatic actuation. IEEE/ASME Trans. Mechatron. 13(3), 268–277 (2008)CrossRef Yu, N., Hollnagel, C., Blickenstorfer, A., Kollias, S.S., Riener, R.: Comparison of MRI-compatible mechatronic systems with hydrodynamic and pneumatic actuation. IEEE/ASME Trans. Mechatron. 13(3), 268–277 (2008)CrossRef
Metadaten
Titel
Control of Pneumatic Actuators with Long Transmission Lines for Rehabilitation in MRI
verfasst von
Melih Turkseven
Jun Ueda
Copyright-Jahr
2017
DOI
https://doi.org/10.1007/978-3-319-50115-4_8

Neuer Inhalt