Skip to main content

2019 | OriginalPaper | Buchkapitel

CT Extended Hounsfield Unit Range in Radiotherapy Treatment Planning for Patients with Implantable Medical Devices

verfasst von : Zehra Ese, Sima Qamhiyeh, Jakob Kreutner, Gregor Schaefers, Daniel Erni, Waldemar Zylka

Erschienen in: World Congress on Medical Physics and Biomedical Engineering 2018

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Radiotherapy (RT) treatment planning is based on computed tomography (CT) images and traditionally uses the conventional Hounsfield unit (CHU) range. This HU range is suited for human tissue but inappropriate for metallic materials. To guarantee safety of patient carrying implants precise HU quantification is beneficial for accurate dose calculations in planning software. Some modern CT systems offer an extended HU range (EHU). This study focuses the suitability of these two HU ranges for the quantification of metallic components of active implantable medical devices (AIMD). CT acquisitions of various metallic and non-metallic materials aligned in a water phantom were investigated. From our acquisitions we calculated that materials with mass-density ρ > 3.0 g/cm3 cannot be represented in the CHU range. For these materials the EHU range could be used for accurate HU quantification. Since the EHU range does not effect the HU values for materials ρ < 3.0 g/cm3, it can be used as a standard for RT treatment planning for patient with and without implants.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Gauter-Fleckenstein, B., Israel, C.W., Dorenkamp, M., Dunst, J., Roser, M., Schimpf, R., Steil, V., Schaefer, J., Hoeller, U., Wenz, F.: DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices. Strahlentherapie Onkologie 191, 393–404 (2015) Gauter-Fleckenstein, B., Israel, C.W., Dorenkamp, M., Dunst, J., Roser, M., Schimpf, R., Steil, V., Schaefer, J., Hoeller, U., Wenz, F.: DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices. Strahlentherapie Onkologie 191, 393–404 (2015)
2.
Zurück zum Zitat Zaremba, T.: Radiotherapy in Patients with Pacemakers and Implantable Cardioverter-Defibrillators. PhD Thesis, Aalborg University (2015) Zaremba, T.: Radiotherapy in Patients with Pacemakers and Implantable Cardioverter-Defibrillators. PhD Thesis, Aalborg University (2015)
3.
Zurück zum Zitat Prisciandro, J.I., Makkar, A., Fox, C.J., Hayman, J.A., Horwood, F., Pelosi, L., Moran, J.M.: Dosimetric review of cardiac implantable electronic device patients receiving radiotherapy. Journal of Applied Clinical Medical Physics 16, 1–8 (2014) Prisciandro, J.I., Makkar, A., Fox, C.J., Hayman, J.A., Horwood, F., Pelosi, L., Moran, J.M.: Dosimetric review of cardiac implantable electronic device patients receiving radiotherapy. Journal of Applied Clinical Medical Physics 16, 1–8 (2014)
4.
Zurück zum Zitat Marbach, J.R., Sontag, M.R., Van Dyk, J., Wolbarst, A.B.: Management of Radiation Oncology Patients with Implanted Cardiac Pacemakers: Report of AAPM Task Group No.34. Medical Physics 21(1), 85–90 (1994) Marbach, J.R., Sontag, M.R., Van Dyk, J., Wolbarst, A.B.: Management of Radiation Oncology Patients with Implanted Cardiac Pacemakers: Report of AAPM Task Group No.34. Medical Physics 21(1), 85–90 (1994)
5.
Zurück zum Zitat Bourgouin, A., Varfalvy, N., Archambault, L.: Estimating and reducing dose received by cardiac devices for patients undergoing radiotherapy. Journal of Applied Clinical Medical Physics 16(6), 411–420 (2015) Bourgouin, A., Varfalvy, N., Archambault, L.: Estimating and reducing dose received by cardiac devices for patients undergoing radiotherapy. Journal of Applied Clinical Medical Physics 16(6), 411–420 (2015)
6.
Zurück zum Zitat Huang, J.Y., Followill, D.S., Wang, X.A., Kry, S.f.: Accuracy and sources of error out-of-field dose calculations by commercial treatment planning system for intensity-modulated radiation therapy treatments. Journal of Applied Clinical Medical Physics 14(2), 4139 (2015) Huang, J.Y., Followill, D.S., Wang, X.A., Kry, S.f.: Accuracy and sources of error out-of-field dose calculations by commercial treatment planning system for intensity-modulated radiation therapy treatments. Journal of Applied Clinical Medical Physics 14(2), 4139 (2015)
7.
Zurück zum Zitat Howell, R.M., Scarboto, S.B., Kry, S.F., Yaldo, D.Z.: Accuracy of out-of-field dose calculations by a commercial treatment planning system. Physics in Medicine and Biology 55(23), 6999–7008 (2010) Howell, R.M., Scarboto, S.B., Kry, S.F., Yaldo, D.Z.: Accuracy of out-of-field dose calculations by a commercial treatment planning system. Physics in Medicine and Biology 55(23), 6999–7008 (2010)
8.
Zurück zum Zitat Kairn, T., Crowe, S.B., Kenny, J., Mitchell, J., Burke, M., Schlect, D., Trapp, J.V.: Dosimetric effects of a high-density spinal implant. Journal of Physics: Conference Series, 7th International Conference on 3D Radiation Dosimetry 444, 1–4 (2008) Kairn, T., Crowe, S.B., Kenny, J., Mitchell, J., Burke, M., Schlect, D., Trapp, J.V.: Dosimetric effects of a high-density spinal implant. Journal of Physics: Conference Series, 7th International Conference on 3D Radiation Dosimetry 444, 1–4 (2008)
9.
Zurück zum Zitat Mullins, J.P., Grams, M.P., Herman, M.G., Brinkmann, D.H., Antolak, J.A.: Treatment planning for metals using an extended CT number scale. Journal of Applied Clinical Medical Physics 17(6), 179–188 (2016) Mullins, J.P., Grams, M.P., Herman, M.G., Brinkmann, D.H., Antolak, J.A.: Treatment planning for metals using an extended CT number scale. Journal of Applied Clinical Medical Physics 17(6), 179–188 (2016)
10.
Zurück zum Zitat Gossman, M.S., Graves-Calhoun, A.R., Wilkinson, J.D.: Establishing radiation therapy treatment planning effects involving implantable pacemakers and implantable cardioverter-defibrillator. Journal of Applied Clinical Medical Physics 11(1), 33–45 (2009) Gossman, M.S., Graves-Calhoun, A.R., Wilkinson, J.D.: Establishing radiation therapy treatment planning effects involving implantable pacemakers and implantable cardioverter-defibrillator. Journal of Applied Clinical Medical Physics 11(1), 33–45 (2009)
11.
Zurück zum Zitat Ese, Z., Kressmann, M., Kreutner, J., Schaefers, G., Erni, D., Zylka, W.: Influence of conventional and extended CT scale range on quantification of Hounsfield units of medical implants and metallic objects. tm-Technisches Messen 85(5), 343-350 (2018) Ese, Z., Kressmann, M., Kreutner, J., Schaefers, G., Erni, D., Zylka, W.: Influence of conventional and extended CT scale range on quantification of Hounsfield units of medical implants and metallic objects. tm-Technisches Messen 85(5), 343-350 (2018)
12.
Zurück zum Zitat Hubbell, J.H.: Photon Cross Sections, Attenuation Coefficients, and Energy Absorption Coefficients From 10 keV to 100 GeV. Nat. Stand. Ref. Data. Ser., Nat. Bur. Stand. (U.S.), 29, 85 (1969) Hubbell, J.H.: Photon Cross Sections, Attenuation Coefficients, and Energy Absorption Coefficients From 10 keV to 100 GeV. Nat. Stand. Ref. Data. Ser., Nat. Bur. Stand. (U.S.), 29, 85 (1969)
13.
Zurück zum Zitat Barrett, J.F., Keal, N.: Artifacts in CT: Recognition and Avoidance. RadioGraphics 24(6), 1679–1691 (2004) Barrett, J.F., Keal, N.: Artifacts in CT: Recognition and Avoidance. RadioGraphics 24(6), 1679–1691 (2004)
14.
Zurück zum Zitat Xin-ye, N., Liugang, G., Mingming, F., Tao, L.: Application of Metal Implant 16-Bit Imaging: New Technique in Radiotherapy. Technology in Cancer Research and Treatment 16(2), 188–194 (2017) Xin-ye, N., Liugang, G., Mingming, F., Tao, L.: Application of Metal Implant 16-Bit Imaging: New Technique in Radiotherapy. Technology in Cancer Research and Treatment 16(2), 188–194 (2017)
Metadaten
Titel
CT Extended Hounsfield Unit Range in Radiotherapy Treatment Planning for Patients with Implantable Medical Devices
verfasst von
Zehra Ese
Sima Qamhiyeh
Jakob Kreutner
Gregor Schaefers
Daniel Erni
Waldemar Zylka
Copyright-Jahr
2019
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-9023-3_111

Neuer Inhalt