Abstract

This chapter presents an overview of the digital biochip design process, highlighting the main design tasks, with a focus on fault-tolerant biochips. The purpose is to explain how the methods presented in this book are used within a design methodology and to define the main design tasks. We highlight the difference between the “compilation” and “synthesis” terms used throughout the book. We discuss in more detail the compilation task, which is covered by Parts II and III, and its constituent subtasks. The architecture synthesis tasks are covered in Part IV. This chapter is intended to help in understanding how the methods presented in the book interact with each other. This chapter also presents the related work in the area of compilation and architecture synthesis approaches for digital microfluidic biochips.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Alistar, M., Pop, P.: Synthesis of biochemical applications on digital microfluidic biochips with operation execution time variability. Integr. VLSI J. (2015). In Press Alistar, M., Pop, P.: Synthesis of biochemical applications on digital microfluidic biochips with operation execution time variability. Integr. VLSI J. (2015). In Press
2.
Zurück zum Zitat Alistar, M., Maftei, E., Pop, P., Madsen, J.: Synthesis of biochemical applications on digital microfluidic biochips with operation variability. In: Proceedings of the Symposium on Design Test Integration and Packaging of MEMS/MOEMS, pp. 350–357 (2010) Alistar, M., Maftei, E., Pop, P., Madsen, J.: Synthesis of biochemical applications on digital microfluidic biochips with operation variability. In: Proceedings of the Symposium on Design Test Integration and Packaging of MEMS/MOEMS, pp. 350–357 (2010)
3.
Zurück zum Zitat Alistar, M., Pop, P., Madsen, J.: Online synthesis for error recovery in digital microfluidic biochips with operation variability. In: Proceedings of the Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS, pp. 53–58 (2012) Alistar, M., Pop, P., Madsen, J.: Online synthesis for error recovery in digital microfluidic biochips with operation variability. In: Proceedings of the Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS, pp. 53–58 (2012)
4.
Zurück zum Zitat Alistar, M., Pop, P., Madsen, J.: Application-specific fault-tolerant architecture synthesis for digital microfluidic biochips. In: Proceedings of the 18th Asia and South Pacific Design Automation Conference, pp. 794–800 (2013) Alistar, M., Pop, P., Madsen, J.: Application-specific fault-tolerant architecture synthesis for digital microfluidic biochips. In: Proceedings of the 18th Asia and South Pacific Design Automation Conference, pp. 794–800 (2013)
5.
Zurück zum Zitat Alistar, M., Pop, P., Madsen, J.: Redundancy optimization for error recovery in digital microfluidic biochips. Des. Autom. Embed. Syst. 19, 129–159 (2015)CrossRef Alistar, M., Pop, P., Madsen, J.: Redundancy optimization for error recovery in digital microfluidic biochips. Des. Autom. Embed. Syst. 19, 129–159 (2015)CrossRef
7.
Zurück zum Zitat Bohringer, K.F.: Towards optimal strategies for moving droplets in digital microfluidic systems. In: Proceedings of IEEE International Conference on Robotics and Automation, pp. 1468–1474 (2004) Bohringer, K.F.: Towards optimal strategies for moving droplets in digital microfluidic systems. In: Proceedings of IEEE International Conference on Robotics and Automation, pp. 1468–1474 (2004)
8.
Zurück zum Zitat Chakrabarty, K., Su, F.: Digital Microfluidic Biochips: Synthesis, Testing, and Reconfiguration Techniques. CRC Press, Boca Raton (2006)CrossRef Chakrabarty, K., Su, F.: Digital Microfluidic Biochips: Synthesis, Testing, and Reconfiguration Techniques. CRC Press, Boca Raton (2006)CrossRef
9.
Zurück zum Zitat Chakrabarty, K., Fair, R.B., Zeng, J.: Design tools for digital microfluidic biochips: towards functional diversification and more than Moore. Trans. Comput. Aided Des. Integr. Circuits Syst. 29(7), 1001–1017 (2010). doi:10.1109/TCAD.2010.2049153 CrossRef Chakrabarty, K., Fair, R.B., Zeng, J.: Design tools for digital microfluidic biochips: towards functional diversification and more than Moore. Trans. Comput. Aided Des. Integr. Circuits Syst. 29(7), 1001–1017 (2010). doi:10.​1109/​TCAD.​2010.​2049153 CrossRef
10.
Zurück zum Zitat Cho, M., Pan, D.Z.: A high-performance droplet router for digital microfluidic biochips. In: Proceedings of the International Symposium on Physical Design, pp. 200–206 (2008) Cho, M., Pan, D.Z.: A high-performance droplet router for digital microfluidic biochips. In: Proceedings of the International Symposium on Physical Design, pp. 200–206 (2008)
11.
Zurück zum Zitat Ding, J., Chakrabarty, K., Fair, R.B.: Scheduling of microfluidic operations for reconfigurable two-dimensional electrowetting arrays. Trans. Comput. Aided Des. Integr. Circuits Syst. 20, 1463–1468 (2001)CrossRef Ding, J., Chakrabarty, K., Fair, R.B.: Scheduling of microfluidic operations for reconfigurable two-dimensional electrowetting arrays. Trans. Comput. Aided Des. Integr. Circuits Syst. 20, 1463–1468 (2001)CrossRef
12.
Zurück zum Zitat Gong, M., Kim, C.J.: Two-dimensional digital microfluidic system by multilayer printed circuit board. In: Proceedings of the Conference on Micro Electro Mechanical Systems, pp. 726–729 (2005) Gong, M., Kim, C.J.: Two-dimensional digital microfluidic system by multilayer printed circuit board. In: Proceedings of the Conference on Micro Electro Mechanical Systems, pp. 726–729 (2005)
13.
Zurück zum Zitat Griffith, E.J., Akella, S., Goldberg, M.K.: Performance characterization of a reconfigurable plannar array digital microfluidic system. Trans. Comput. Aided Des. Integr. Circuits Syst. 25, 340–352 (2006) Griffith, E.J., Akella, S., Goldberg, M.K.: Performance characterization of a reconfigurable plannar array digital microfluidic system. Trans. Comput. Aided Des. Integr. Circuits Syst. 25, 340–352 (2006)
14.
Zurück zum Zitat Grissom, D., Brisk, P.: Fast online synthesis of generally programmable digital microfluidic biochips. In: Proceedings of the 8th International Conference on Hardware/Software Codesign and System Synthesis, pp. 413–422 (2012) Grissom, D., Brisk, P.: Fast online synthesis of generally programmable digital microfluidic biochips. In: Proceedings of the 8th International Conference on Hardware/Software Codesign and System Synthesis, pp. 413–422 (2012)
15.
Zurück zum Zitat Grissom, D., Brisk, P.: Path scheduling on digital microfluidic biochips. In: Proceedings of the 49th Annual Design Automation Conference, pp. 26–35 (2012) Grissom, D., Brisk, P.: Path scheduling on digital microfluidic biochips. In: Proceedings of the 49th Annual Design Automation Conference, pp. 26–35 (2012)
16.
Zurück zum Zitat Ho, T.Y., Zeng, J., Chakrabarty, K.: Digital microfluidic biochips: a vision for functional diversity and more than Moore. In: Proceedings of the International Conference on Computer-Aided Design, pp. 578–585 (2010) Ho, T.Y., Zeng, J., Chakrabarty, K.: Digital microfluidic biochips: a vision for functional diversity and more than Moore. In: Proceedings of the International Conference on Computer-Aided Design, pp. 578–585 (2010)
17.
Zurück zum Zitat Hsieh, Y.L., Ho, T.Y., Chakrabarty, K.: Design methodology for sample preparation on digital microfluidic biochips. In: Proceedings of the 30th International Conference on Computer Design, pp. 189–194 (2012) Hsieh, Y.L., Ho, T.Y., Chakrabarty, K.: Design methodology for sample preparation on digital microfluidic biochips. In: Proceedings of the 30th International Conference on Computer Design, pp. 189–194 (2012)
18.
Zurück zum Zitat Hsieh, Y.L., Ho, T.Y., Chakrabarty, K.: A reagent-saving mixing algorithm for preparing multiple-target biochemical samples using digital microfluidics. IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 31(11), 1656–1669 (2012)CrossRef Hsieh, Y.L., Ho, T.Y., Chakrabarty, K.: A reagent-saving mixing algorithm for preparing multiple-target biochemical samples using digital microfluidics. IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 31(11), 1656–1669 (2012)CrossRef
19.
Zurück zum Zitat Huang, T.W., Ho, T.Y.: A fast routability-and performance-driven droplet routing algorithm for digital microfluidic biochips. In: Proceedings of the International Conference on Computer Design, pp. 445–450 (2009) Huang, T.W., Ho, T.Y.: A fast routability-and performance-driven droplet routing algorithm for digital microfluidic biochips. In: Proceedings of the International Conference on Computer Design, pp. 445–450 (2009)
20.
Zurück zum Zitat Huang, T.W., Lin, C.H., Ho, T.Y.: A contamination aware droplet routing algorithm for digital microfluidic biochips. In: Proceedings of the International Conference on Computer-Aided Design, pp. 151–156 (2009) Huang, T.W., Lin, C.H., Ho, T.Y.: A contamination aware droplet routing algorithm for digital microfluidic biochips. In: Proceedings of the International Conference on Computer-Aided Design, pp. 151–156 (2009)
21.
Zurück zum Zitat Hwang, W., Su, F., Chakrabarty, K.: Automated design of pin-constrained digital microfluidic arrays for lab-on-a-chip applications. In: Proceedings of the Design Automation Conference, pp. 925–930 (2006) Hwang, W., Su, F., Chakrabarty, K.: Automated design of pin-constrained digital microfluidic arrays for lab-on-a-chip applications. In: Proceedings of the Design Automation Conference, pp. 925–930 (2006)
22.
Zurück zum Zitat Kerkhoff, H.G.: Testing microelectronic biofluidic systems. IEEE Des. Test Comput. 24(1), 72–82 (2007)CrossRef Kerkhoff, H.G.: Testing microelectronic biofluidic systems. IEEE Des. Test Comput. 24(1), 72–82 (2007)CrossRef
23.
Zurück zum Zitat Kotchoni, S.O., Gachomo, E.W., Betiku, E., Shonukan, O.O.: A home made kit for plasmid DNA mini-preparation. Afr. J. Biotechn. 2(4), 109–114 (2003) Kotchoni, S.O., Gachomo, E.W., Betiku, E., Shonukan, O.O.: A home made kit for plasmid DNA mini-preparation. Afr. J. Biotechn. 2(4), 109–114 (2003)
24.
Zurück zum Zitat Lin, C.C.Y., Chang, Y.W.: Cross-contamination aware design methodology for pin-constrained digital microfluidic biochips. In: Proceedings of the Design Automation Conference, pp. 641–646 (2010) Lin, C.C.Y., Chang, Y.W.: Cross-contamination aware design methodology for pin-constrained digital microfluidic biochips. In: Proceedings of the Design Automation Conference, pp. 641–646 (2010)
25.
Zurück zum Zitat Lin, C.C.Y., Chang, Y.W.: ILP-based pin-count aware design methodology for microfluidic biochips. Trans. Comput. Aided Des. Integr. Circuits Syst. 29(9), 1315–1327 (2010)CrossRef Lin, C.C.Y., Chang, Y.W.: ILP-based pin-count aware design methodology for microfluidic biochips. Trans. Comput. Aided Des. Integr. Circuits Syst. 29(9), 1315–1327 (2010)CrossRef
26.
Zurück zum Zitat Luo, Y., Chakrabarty, K., Ho, T.Y.: A cyberphysical synthesis approach for error recovery in digital microfluidic biochips. In: Proceedings of the Conference on Design, Automation and Test in Europe, pp. 1239–1244 (2012) Luo, Y., Chakrabarty, K., Ho, T.Y.: A cyberphysical synthesis approach for error recovery in digital microfluidic biochips. In: Proceedings of the Conference on Design, Automation and Test in Europe, pp. 1239–1244 (2012)
27.
Zurück zum Zitat Luo, Y., Bhattacharya, B.B., Ho, T.Y., Chakrabarty, K.: Optimization of polymerase chain reaction on a cyberphysical digital microfluidic biochip. In: Proceedings of the International Conference on Computer-Aided Design, pp. 622–629 (2013) Luo, Y., Bhattacharya, B.B., Ho, T.Y., Chakrabarty, K.: Optimization of polymerase chain reaction on a cyberphysical digital microfluidic biochip. In: Proceedings of the International Conference on Computer-Aided Design, pp. 622–629 (2013)
28.
Zurück zum Zitat Luo, Y., Chakrabarty, K., Ho, T.Y.: Design of cyberphysical digital microfluidic biochips under completion-time uncertainties in fluidic operations. In: Proceedings of the 50th Annual Design Automation Conference, p. 44 (2013) Luo, Y., Chakrabarty, K., Ho, T.Y.: Design of cyberphysical digital microfluidic biochips under completion-time uncertainties in fluidic operations. In: Proceedings of the 50th Annual Design Automation Conference, p. 44 (2013)
29.
Zurück zum Zitat Luo, Y., Chakrabarty, K., Ho, T.Y.: Real-time error recovery in cyberphysical digital-microfluidic biochips using a compact dictionary. IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 32(12), 1839–1852 (2013)CrossRef Luo, Y., Chakrabarty, K., Ho, T.Y.: Real-time error recovery in cyberphysical digital-microfluidic biochips using a compact dictionary. IEEE Trans. Comput. Aided Des. Integr. Circuits Syst. 32(12), 1839–1852 (2013)CrossRef
30.
Zurück zum Zitat Maftei, E., Paul, P., Madsen, J., Stidsen, T.: Placement-aware architectural synthesis of digital microfluidic biochips using ILP. In: Proceedings of the International Conference on Very Large Scale Integration of System on Chip, pp. 425–430 (2008) Maftei, E., Paul, P., Madsen, J., Stidsen, T.: Placement-aware architectural synthesis of digital microfluidic biochips using ILP. In: Proceedings of the International Conference on Very Large Scale Integration of System on Chip, pp. 425–430 (2008)
31.
Zurück zum Zitat Maftei, E., Pop, P., Madsen, J.: Tabu search-based synthesis of digital microfluidic biochips with dynamically reconfigurable non-rectangular devices. Des. Autom. Embed. Syst. 14(3), 287–307 (2010)CrossRef Maftei, E., Pop, P., Madsen, J.: Tabu search-based synthesis of digital microfluidic biochips with dynamically reconfigurable non-rectangular devices. Des. Autom. Embed. Syst. 14(3), 287–307 (2010)CrossRef
32.
Zurück zum Zitat Maftei, E., Pop, P., Madsen, J.: Droplet-aware module-based synthesis for fault-tolerant digital microfluidic biochips. In: Proceedings of the Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS, pp. 47–52 (2012) Maftei, E., Pop, P., Madsen, J.: Droplet-aware module-based synthesis for fault-tolerant digital microfluidic biochips. In: Proceedings of the Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS, pp. 47–52 (2012)
33.
Zurück zum Zitat Pollack, M.G., Shenderov, A.D., Fair, R.B.: Electrowetting-based actuation of droplets for integrated microfluidics. Lab Chip 2, 96–101 (2002)CrossRef Pollack, M.G., Shenderov, A.D., Fair, R.B.: Electrowetting-based actuation of droplets for integrated microfluidics. Lab Chip 2, 96–101 (2002)CrossRef
34.
Zurück zum Zitat Ren, H., Srinivasan, V., Fair, R.B.: Design and testing of an interpolating mixing architecture for electrowetting-based droplet-on-chip chemical dilution. In: Proceedings of the International Conference on Transducers, Solid-State Sensors, Actuators and Microsystems, pp. 619–622 (2003) Ren, H., Srinivasan, V., Fair, R.B.: Design and testing of an interpolating mixing architecture for electrowetting-based droplet-on-chip chemical dilution. In: Proceedings of the International Conference on Transducers, Solid-State Sensors, Actuators and Microsystems, pp. 619–622 (2003)
35.
Zurück zum Zitat Ricketts, A., Irick, K., Vijaykrishnan, N., Irwin, M.: Priority scheduling in digital microfluidics-based biochips. In: Proceedings of the Design, Automation and Test in Europe, vol. 1, pp. 1–6 (2006) Ricketts, A., Irick, K., Vijaykrishnan, N., Irwin, M.: Priority scheduling in digital microfluidics-based biochips. In: Proceedings of the Design, Automation and Test in Europe, vol. 1, pp. 1–6 (2006)
36.
Zurück zum Zitat Rose, D.: Microdispensing technologies in drug discovery. Drug Discov. Today 4(9), 411–419 (1999)CrossRef Rose, D.: Microdispensing technologies in drug discovery. Drug Discov. Today 4(9), 411–419 (1999)CrossRef
37.
Zurück zum Zitat Roy, S., Bhattacharya, B.B., Chakrabarty, K.: Waste-aware dilution and mixing of biochemical samples with digital microfluidic biochips. In: Proceedings of the Conference on Design, Automation and Test in Europe, pp. 1–6 (2011) Roy, S., Bhattacharya, B.B., Chakrabarty, K.: Waste-aware dilution and mixing of biochemical samples with digital microfluidic biochips. In: Proceedings of the Conference on Design, Automation and Test in Europe, pp. 1–6 (2011)
38.
Zurück zum Zitat Sista, R.S., Eckhardt, A.E., Wang, T., Graham, C., Rouse, J.L., Norton, S.M., Srinivasan, V., Pollack, M.G., Tolun, A.A., Bali, D., et al.: Digital microfluidic platform for multiplexing enzyme assays: implications for lysosomal storage disease screening in newborns. Clin. Chem. 57(10), 1444–1451 (2011)CrossRef Sista, R.S., Eckhardt, A.E., Wang, T., Graham, C., Rouse, J.L., Norton, S.M., Srinivasan, V., Pollack, M.G., Tolun, A.A., Bali, D., et al.: Digital microfluidic platform for multiplexing enzyme assays: implications for lysosomal storage disease screening in newborns. Clin. Chem. 57(10), 1444–1451 (2011)CrossRef
39.
Zurück zum Zitat Su, F., Chakrabarty, K.: Architectural-level synthesis of digital microfluidics-based biochips. In: Proceedings of the International Conference on Computer Aided Design, pp. 223–228 (2004) Su, F., Chakrabarty, K.: Architectural-level synthesis of digital microfluidics-based biochips. In: Proceedings of the International Conference on Computer Aided Design, pp. 223–228 (2004)
40.
Zurück zum Zitat Su, F., Chakrabarty, K.: Design of fault-tolerant and dynamically-reconfigurable microfluidic biochips. In: Proceedings of the Conference on Design, Automation and Test in Europe, pp. 1202–1207 (2005) Su, F., Chakrabarty, K.: Design of fault-tolerant and dynamically-reconfigurable microfluidic biochips. In: Proceedings of the Conference on Design, Automation and Test in Europe, pp. 1202–1207 (2005)
42.
Zurück zum Zitat Su, F., Chakrabarty, K.: Module placement for fault-tolerant microfluidics-based biochips. ACM Trans. Des. Autom. Electron. Syst. 11(3), 682–710 (2006)CrossRef Su, F., Chakrabarty, K.: Module placement for fault-tolerant microfluidics-based biochips. ACM Trans. Des. Autom. Electron. Syst. 11(3), 682–710 (2006)CrossRef
43.
Zurück zum Zitat Su, F., Chakrabarty, K.: Yield enhancement of reconfigurable microfluidics-based biochips using interstitial redundancy. J. Emerg. Technol. Comput. Syst. 2(2), 104–128 (2006)CrossRef Su, F., Chakrabarty, K.: Yield enhancement of reconfigurable microfluidics-based biochips using interstitial redundancy. J. Emerg. Technol. Comput. Syst. 2(2), 104–128 (2006)CrossRef
44.
Zurück zum Zitat Su, F., Chakrabarty, K.: High-level synthesis of digital microfluidic biochips. J. Emerg. Technol. Comput. Syst. 3(4), 1 (2008)CrossRef Su, F., Chakrabarty, K.: High-level synthesis of digital microfluidic biochips. J. Emerg. Technol. Comput. Syst. 3(4), 1 (2008)CrossRef
45.
Zurück zum Zitat Su, F., Ozev, S., Chakrabarty, K.: Testing of droplet-based microelectrofluidic systems. In: Proceedings of the International Test Conference, pp. 1192–1200 (2003) Su, F., Ozev, S., Chakrabarty, K.: Testing of droplet-based microelectrofluidic systems. In: Proceedings of the International Test Conference, pp. 1192–1200 (2003)
46.
Zurück zum Zitat Su, F., Ozev, S., Chakrabarty, K.: Concurrent testing of droplet-based microfluidic systems for multiplexed biomedical systems. In: Proceedings of the International Test Conference, pp. 883–892 (2004) Su, F., Ozev, S., Chakrabarty, K.: Concurrent testing of droplet-based microfluidic systems for multiplexed biomedical systems. In: Proceedings of the International Test Conference, pp. 883–892 (2004)
47.
Zurück zum Zitat Su, F., Ozev, S., Chakrabarty, K.: Ensuring the operational health of droplet-based microelectrofluidic biosensor systems. IEEE J. Sens. 5, 763–773 (2005)CrossRef Su, F., Ozev, S., Chakrabarty, K.: Ensuring the operational health of droplet-based microelectrofluidic biosensor systems. IEEE J. Sens. 5, 763–773 (2005)CrossRef
48.
Zurück zum Zitat Su, F., Hwang, W., Mukherjee, A., Chakrabarty, K.: Defect-oriented testing and diagnosis of digital microfluidics-based biochips. In: Proceedings of the International Test Conference, pp. 487–496 (2005) Su, F., Hwang, W., Mukherjee, A., Chakrabarty, K.: Defect-oriented testing and diagnosis of digital microfluidics-based biochips. In: Proceedings of the International Test Conference, pp. 487–496 (2005)
49.
Zurück zum Zitat Su, F., Hwang, W., Chakrabarty, K.: Droplet routing in the synthesis of digital microfluidic biochips. In: Proceedings of the Design, Automation and Test in Europe, vol. 1, pp. 73–78 (2006) Su, F., Hwang, W., Chakrabarty, K.: Droplet routing in the synthesis of digital microfluidic biochips. In: Proceedings of the Design, Automation and Test in Europe, vol. 1, pp. 73–78 (2006)
50.
Zurück zum Zitat Su, F., Hwang, W., Mukherjee, A., Chakrabarty, K.: Testing and diagnosis of realistic defects in digital microfluidic biochips. J. Electron. Test. 23(2–3), 219–233 (2007)CrossRef Su, F., Hwang, W., Mukherjee, A., Chakrabarty, K.: Testing and diagnosis of realistic defects in digital microfluidic biochips. J. Electron. Test. 23(2–3), 219–233 (2007)CrossRef
51.
Zurück zum Zitat Xiao, Z., Young, E.F.Y.: Crossrouter: a droplet router for cross-referencing digital microfluidic biochips. In: Proceedings of the Asia and South Pacific Design Automation Conference, pp. 269–274 (2010) Xiao, Z., Young, E.F.Y.: Crossrouter: a droplet router for cross-referencing digital microfluidic biochips. In: Proceedings of the Asia and South Pacific Design Automation Conference, pp. 269–274 (2010)
52.
Zurück zum Zitat Xu, T., Chakrabarty, K.: Droplet-trace-based array partitioning and a pin assignment algorithm for the automated design of digital microfluidic biochips. In: Proceedings of the International Conference on Hardware/Software Codesign and System Synthesis, pp. 112–117 (2006) Xu, T., Chakrabarty, K.: Droplet-trace-based array partitioning and a pin assignment algorithm for the automated design of digital microfluidic biochips. In: Proceedings of the International Conference on Hardware/Software Codesign and System Synthesis, pp. 112–117 (2006)
53.
Zurück zum Zitat Xu, T., Chakrabarty, K.: A cross-referencing-based droplet manipulation method for high-throughput and pin-constrained digital microfluidic arrays. In: Proceedings of the Conference on Design, Automation and Test in Europe, pp. 552–557 (2007) Xu, T., Chakrabarty, K.: A cross-referencing-based droplet manipulation method for high-throughput and pin-constrained digital microfluidic arrays. In: Proceedings of the Conference on Design, Automation and Test in Europe, pp. 552–557 (2007)
54.
Zurück zum Zitat Xu, T., Chakrabarty, K.: Functional testing of digital microfluidic biochips. In: Proceedings of the International Test Conference, pp. 1–10 (2007) Xu, T., Chakrabarty, K.: Functional testing of digital microfluidic biochips. In: Proceedings of the International Test Conference, pp. 1–10 (2007)
55.
Zurück zum Zitat Xu, T., Chakrabarty, K.: Integrated droplet routing and defect tolerance in the synthesis of digital microfluidic biochips. In: Proceedings of the Design Automation Conference, pp. 948–953 (2007) Xu, T., Chakrabarty, K.: Integrated droplet routing and defect tolerance in the synthesis of digital microfluidic biochips. In: Proceedings of the Design Automation Conference, pp. 948–953 (2007)
56.
Zurück zum Zitat Xu, T., Chakrabarty, K.: Parallel scan-like testing and fault diagnosis techniques for digital microfluidic biochips. In: Proceedings of the European Test Symposium, pp. 63–68 (2007) Xu, T., Chakrabarty, K.: Parallel scan-like testing and fault diagnosis techniques for digital microfluidic biochips. In: Proceedings of the European Test Symposium, pp. 63–68 (2007)
57.
Zurück zum Zitat Xu, T., Chakrabarty, K.: Broadcast electrode-addressing for pin-constrained multi-functional digital microfluidic biochips. In: Proceedings of the Design Automation Conference, pp. 173–178 (2008) Xu, T., Chakrabarty, K.: Broadcast electrode-addressing for pin-constrained multi-functional digital microfluidic biochips. In: Proceedings of the Design Automation Conference, pp. 173–178 (2008)
58.
Zurück zum Zitat Xu, T., Chakrabarty, K.: Integrated droplet routing and defect tolerance in the synthesis of digital microfluidic biochips. J. Emerg. Technol. Comput. Syst. 4(3), 11 (2008)CrossRef Xu, T., Chakrabarty, K.: Integrated droplet routing and defect tolerance in the synthesis of digital microfluidic biochips. J. Emerg. Technol. Comput. Syst. 4(3), 11 (2008)CrossRef
59.
Zurück zum Zitat Xu, T., Chakrabarty, K.: Fault modeling and functional test methods for digital microfluidic biochips. Trans. Biomed. Circuits Syst. 3(4), 241–253 (2009)CrossRef Xu, T., Chakrabarty, K.: Fault modeling and functional test methods for digital microfluidic biochips. Trans. Biomed. Circuits Syst. 3(4), 241–253 (2009)CrossRef
60.
Zurück zum Zitat Yuh, P.H., Yang, C.L., Chang, Y.W.: Placement of defect-tolerant digital microfluidic biochips using the T-tree formulation. ACM J. Emerg. Technol. Comput. Syst. 3(3) (2007) Yuh, P.H., Yang, C.L., Chang, Y.W.: Placement of defect-tolerant digital microfluidic biochips using the T-tree formulation. ACM J. Emerg. Technol. Comput. Syst. 3(3) (2007)
61.
Zurück zum Zitat Yuh, P.H., Yang, C.L., Chang, Y.W.: Bioroute: A network-flow-based routing algorithm for the synthesis of digital microfluidic biochips. Trans. Comput. Aided Des. Integr. Circuits Syst. 27(11), 1928–1941 (2008)CrossRef Yuh, P.H., Yang, C.L., Chang, Y.W.: Bioroute: A network-flow-based routing algorithm for the synthesis of digital microfluidic biochips. Trans. Comput. Aided Des. Integr. Circuits Syst. 27(11), 1928–1941 (2008)CrossRef
62.
Zurück zum Zitat Zhao, Y., Chakrabarty, K.: Cross-contamination avoidance for droplet routing in digital microfluidic biochips. In: Proceedings of the Conference on Design, Automation and Test in Europe, pp. 1290–1295 (2009) Zhao, Y., Chakrabarty, K.: Cross-contamination avoidance for droplet routing in digital microfluidic biochips. In: Proceedings of the Conference on Design, Automation and Test in Europe, pp. 1290–1295 (2009)
63.
Zurück zum Zitat Zhao, Y., Chakrabarty, K.: Synchronization of washing operations with droplet routing for cross-contamination avoidance in digital microfluidic biochips. In: Proceedings of the Design Automation Conference, pp. 641–646 (2010) Zhao, Y., Chakrabarty, K.: Synchronization of washing operations with droplet routing for cross-contamination avoidance in digital microfluidic biochips. In: Proceedings of the Design Automation Conference, pp. 641–646 (2010)
64.
Zurück zum Zitat Zhao, Y., Chakrabarty, K.: Cross-contamination avoidance for droplet routing. In: Design and Testing of Digital Microfluidic Biochips, pp. 27–55. Springer, Berlin (2013) Zhao, Y., Chakrabarty, K.: Cross-contamination avoidance for droplet routing. In: Design and Testing of Digital Microfluidic Biochips, pp. 27–55. Springer, Berlin (2013)
65.
Zurück zum Zitat Zhao, Y., Xu, T., Chakrabarty, K.: Integrated control-path design and error recovery in the synthesis of digital microfluidic lab-on-chip. J. Emerg. Technol. Comput. Syst. 6(3), 11 (2010)CrossRef Zhao, Y., Xu, T., Chakrabarty, K.: Integrated control-path design and error recovery in the synthesis of digital microfluidic lab-on-chip. J. Emerg. Technol. Comput. Syst. 6(3), 11 (2010)CrossRef
66.
Zurück zum Zitat Zhao, Y., Chakrabarty, K., Sturmer, R., Pamula, V.K.: Optimization techniques for the synchronization of concurrent fluidic operations in pin-constrained digital microfluidic biochips. Trans. Very Large Scale Integr. VLSI Syst. 20(6), 1132–1145 (2012)CrossRef Zhao, Y., Chakrabarty, K., Sturmer, R., Pamula, V.K.: Optimization techniques for the synchronization of concurrent fluidic operations in pin-constrained digital microfluidic biochips. Trans. Very Large Scale Integr. VLSI Syst. 20(6), 1132–1145 (2012)CrossRef
Metadaten
Titel
Design Methodology for Digital Microfluidic Biochips
verfasst von
Paul Pop
Mirela Alistar
Elena Stuart
Jan Madsen
Copyright-Jahr
2016
DOI
https://doi.org/10.1007/978-3-319-23072-6_2

Neuer Inhalt