Skip to main content
Erschienen in: Optical and Quantum Electronics 3/2024

01.03.2024

Diagnostic value of abdominal X-ray film and multi-slice spiral CT in patients with acute intestinal obstruction by using optical medical equipment

verfasst von: Dandan Dong, Ye Tian, Xiujuan Liu, Xiangrong Yu, Jingming Wang

Erschienen in: Optical and Quantum Electronics | Ausgabe 3/2024

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Acute intestinal obstruction is a frequently encountered condition characterized by sudden abdominal pain, and its prompt and accurate diagnosis plays a crucial role in the management and prognosis of patients. Although traditional abdominal X-ray imaging has certain limitations in identifying acute ileus, the emergence of multi-slice spiral CT has offered potential as a non-invasive diagnostic tool. Thus, this study aimed to assess the diagnostic efficacy of abdominal radiographs and multi-slice spiral CT in acute ileus and explore their respective advantages and limitations. A total of 64 patients diagnosed with acute intestinal obstruction and admitted to our hospital between March 2021 and March 2022 for surgical intervention were selected for this study. All patients initially underwent conventional abdominal X-ray examinations, followed by multi-slice spiral CT scans after a 12-hour interval. In the case of acute intestinal obstruction patients, multi-slice spiral CT demonstrated superior diagnostic performance compared to abdominal X-ray plain film. The use of multi-slice spiral CT resulted in enhanced diagnostic experience, lower rates of missed diagnosis and misdiagnosis.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Fang, Z., Qianli, R., Hongfu, Z., et al.: Diagnosis of multi-slice spiral CTin location and cause of intestinal obstruction[J]. Anhui Med. J. 22(S2), 61–63 (2018) Fang, Z., Qianli, R., Hongfu, Z., et al.: Diagnosis of multi-slice spiral CTin location and cause of intestinal obstruction[J]. Anhui Med. J. 22(S2), 61–63 (2018)
Zurück zum Zitat Hong, C.: Value of 64-Slice spiral CT in the diagnosis of Acute Intestinal Obstruction[J]. J. Imaging Res. Med. Appl. 11(04), 36–40 (2018) Hong, C.: Value of 64-Slice spiral CT in the diagnosis of Acute Intestinal Obstruction[J]. J. Imaging Res. Med. Appl. 11(04), 36–40 (2018)
Zurück zum Zitat Jing, D., Xiao-Hang, Y.: Application value of multi-slice spiral CT in radiodiagnosis of intestinal obstruction[J]. Gen. J. Stomatology. 127(10), 696–697 (2019) Jing, D., Xiao-Hang, Y.: Application value of multi-slice spiral CT in radiodiagnosis of intestinal obstruction[J]. Gen. J. Stomatology. 127(10), 696–697 (2019)
Zurück zum Zitat Li Hongcheng, X.X.: Comparison of multislice spiral CT and abdominal X-ray plain film in the diagnosis of acute intestinal obstruction [J]. Chin. J. CT MRI. 17(7), 125–127 (2019) Li Hongcheng, X.X.: Comparison of multislice spiral CT and abdominal X-ray plain film in the diagnosis of acute intestinal obstruction [J]. Chin. J. CT MRI. 17(7), 125–127 (2019)
Zurück zum Zitat QuanRi, F.: Comparison of early diagnostic efficacy of spiral CT and abdominal X-ray plain film in acute intestinal obstruction [J]. Prog. Mod. Gen. Sur. Chin. 21(5), 397–399 (2018) QuanRi, F.: Comparison of early diagnostic efficacy of spiral CT and abdominal X-ray plain film in acute intestinal obstruction [J]. Prog. Mod. Gen. Sur. Chin. 21(5), 397–399 (2018)
Zurück zum Zitat Song Jiangbin: Study on the diagnostic value of multi-slice spiral CT in various types of acute abdomen [J]. Chin. J. Emerg. Med. 38(0z1), 163–164 (2018) Song Jiangbin: Study on the diagnostic value of multi-slice spiral CT in various types of acute abdomen [J]. Chin. J. Emerg. Med. 38(0z1), 163–164 (2018)
Zurück zum Zitat Wang Li, Y., Yushan, P., et al.: bin,. Comparative study on the diagnostic value of multi-slice spiral CT and abdominal X-ray plain film in acute intestinal obstruction [J]. Modern biomedical progress, 19(03), 540–543 (2019) Wang Li, Y., Yushan, P., et al.: bin,. Comparative study on the diagnostic value of multi-slice spiral CT and abdominal X-ray plain film in acute intestinal obstruction [J]. Modern biomedical progress, 19(03), 540–543 (2019)
Zurück zum Zitat YHalepota, H.F., Mateen Khan, M.A., Shahzad, N.: Sensitivity and specificity of CT scan in small bowel obstruction among children [J]. J. Pak Med. Assoc. 68(5), 744–746 (2018) YHalepota, H.F., Mateen Khan, M.A., Shahzad, N.: Sensitivity and specificity of CT scan in small bowel obstruction among children [J]. J. Pak Med. Assoc. 68(5), 744–746 (2018)
Zurück zum Zitat Zhen, S.: The value of multi-slice spiral CT multiplanar reconstruction in the diagnosis of acute intestinal obstruction[J]. Contemp. Med. 38(3), 1749–1753 (2019) Zhen, S.: The value of multi-slice spiral CT multiplanar reconstruction in the diagnosis of acute intestinal obstruction[J]. Contemp. Med. 38(3), 1749–1753 (2019)
Metadaten
Titel
Diagnostic value of abdominal X-ray film and multi-slice spiral CT in patients with acute intestinal obstruction by using optical medical equipment
verfasst von
Dandan Dong
Ye Tian
Xiujuan Liu
Xiangrong Yu
Jingming Wang
Publikationsdatum
01.03.2024
Verlag
Springer US
Erschienen in
Optical and Quantum Electronics / Ausgabe 3/2024
Print ISSN: 0306-8919
Elektronische ISSN: 1572-817X
DOI
https://doi.org/10.1007/s11082-023-06160-2

Weitere Artikel der Ausgabe 3/2024

Optical and Quantum Electronics 3/2024 Zur Ausgabe

Neuer Inhalt