Skip to main content
Erschienen in:
Buchtitelbild

Open Access 2019 | OriginalPaper | Buchkapitel

15. Dose Coefficients for Use in Rapid Dose Estimation in Industrial Radiography Accidents

verfasst von : Haegin Han, Yeon Soo Yeom, Chansoo Choi, Hanjin Lee, Bangho Shin, Xujia Zhang, Rui Qiu, Nina Petoussi-Henss, Chan Hyeong Kim

Erschienen in: Brain and Human Body Modeling

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

When accidents by industrial radiography sources occur, it is necessary to accurately and quickly estimate radiation doses for the effective treatment of those individuals with acute radiation syndrome (ARS). In the present study, a comprehensive set of absorbed dose coefficients (DCs) was obtained by performing Monte Carlo simulations using computational human phantoms of different body sizes. These DCs provide an “initial and rapid” dose estimation for individuals accidentally exposed to industrial radiography sources. The adult mesh-type ICRP reference computational phantoms (MRCPs) and the adult 10th and 90th percentile computational phantoms, constructed by deforming the MRCPs, were implemented in the Geant4 Monte Carlo code. We subsequently simulated the most commonly used industrial radiography sources (i.e., 192Ir and 60Co) placed in 72 different locations near the human body. It was found that body size significantly influences the DCs, especially when the source is closer than 1 m to the human body, which is a case frequently encountered during industrial radiography accidents. Acknowledging the significance of these results, the ICRP is planning to include the full set of the calculated DCs from this study in a forthcoming ICRP Publication, which is being prepared by the ICRP Committee 2 Task Group 103 “Mesh-type Reference Computational Phantoms.”

15.1 Introduction

Accidents by industrial radiography sources, which usually involve powerful gamma-emitting sources, could result in very high radiation doses to workers, leading to serious injuries or even death [1]. Even members of the public could be accidentally irradiated by such sources when the sources are not properly controlled or regulated. Moreover, industrial radiography accidents are one of the most frequently reported accidents among all reported cases in nuclear-related industries [2]. According to Lima et al. [3], a total of 80 industrial radiography accidents involving 120 workers and 110 members of the public, including 12 deaths, were recorded globally between 1896 and 2014.
Radiation accidents could lead to high radiation doses, which could induce acute radiation syndrome (ARS); these are primarily classified into hematopoietic (0.2–2 Gy), gastrointestinal (6–10 Gy), and cerebrovascular (>10 Gy) syndromes [4]. For the effective management of patients (i.e., exposed individuals) with ARS, initial medical triage should be performed accurately and rapidly, whereby those patients who could develop symptoms should be separately identified from those who do not require medical intervention [5]. Therapies for ARS, such as dose mitigators, should be promptly administered during the latent period in which the exposed person still feels well, i.e., before symptoms occur [6]. For this purpose, it is essential not only to carefully document clinical signs and symptoms but also to accurately and quickly estimate radiation doses to exposed individuals [7].
Individual radiation doses can be estimated using various dosimetric techniques based on biological, physical, and computational approaches. However, all the existing dosimetry techniques have limitations and none of them can be used as a stand-alone tool in a satisfactory manner for most radiation accident scenarios [8]. For instance, biological or physical dosimetry techniques generally require more than several days for sample collection and analysis, and these time-consuming processes make it difficult to perform timely medical triage. These techniques are therefore impractical, especially for use in a large-scale accident involving many individuals [5, 6, 9, 10]. Moreover, these techniques are generally limited to estimating the whole-body dose, without information on organ/tissue doses or dose distributions [8]. It should be noted that information about the whole-body absorbed dose is insufficient, particularly for partial-body or localized exposures. Organ/tissue absorbed doses and/or absorbed dose distributions can be estimated from computational dosimetry approaches (e.g., Monte Carlo simulations with computational human phantoms) if reliable information on the accident scenario is available, including accurate source geometry and duration of exposure [11], which are often unclear in accident situations [8, 12]. No single technique fully meets the criteria of an ideal dosimetry technique for use in accident situations; therefore, an integrated approach using multiple dosimetry techniques is considered the best strategy [8, 13, 14]. Absorbed doses calculated with computational human phantoms could be used as one of the dose estimators, particularly as an “initial, rapid estimator.”
In the present study, a comprehensive set of organ/tissue absorbed dose coefficients (DCs) for industrial radiography sources was obtained by Monte Carlo simulations with the adult male and female mesh-type reference computational phantoms (MRCPs) recently developed by Task Group 103 of the International Commission on Radiological Protection (ICRP) [15]. In addition, adult male and female non-reference computational phantoms that represent the 10th and 90th percentiles of the Caucasian population were also used. These phantoms were constructed by deformation and modification of the MRCPs [16]. Note that for dose estimation of individuals in accident situations, consideration of the reference person would be insufficient, particularly when the body size of the individual involved in the accident is significantly different from that of the reference person. In this case, the dose estimation could be better approximated by using DCs calculated with a non-reference computational phantom whose body size is close to that of the actual individual.
The phantoms were implemented into the Geant4 Monte Carlo code [17] to calculate DCs by simulating the most commonly used industrial radiography sources, i.e., 192Ir and 60Co, for various source locations. The behavior of the calculated DCs was investigated, primarily by comparing the DCs among the different body size phantoms to study the influence of body size on the DCs.

15.2 Material and Methods

15.2.1 Mesh-Type Computational Phantoms

Figure 15.1 shows the adult male and female MRCPs and 10th and 90th percentile phantoms used in the DC calculations. The adult MRCPs were constructed by converting the adult voxel-type reference computational phantoms of ICRP Publication 110 [18] into a high-quality mesh format. This results in an improved representation of various organs/tissues and their ability to accurately estimate doses for very small organs/tissues such as the eye lens, the skin, and respiratory and alimentary tracts [15]. Note that recent developments enabled the direct use of mesh phantoms in Monte Carlo dose calculations, i.e., without going through a “voxelization” process, which is required for most existing surface phantoms (also called hybrid phantoms) [19, 20].
The MRCPs represent the adult reference male and female, as established in ICRP Publication 89 [21] with respect to the reference standing height, body mass (male: 1.76 m and 73 kg; female: 1.63 m and 60 kg) and individual organ and tissue masses. The 10th and 90th percentile phantoms were constructed by Lee et al. [16], by selectively deforming and modifying the MRCPs. The 10th percentile phantoms, which represent small statures, have the 10th percentile standing height and 10th percentile body mass (male: 1.67 m and 56 kg; female: 1.55 m and 44 kg), with organ masses ~25% lighter than those of MRCPs. The 90th percentile phantoms, which represent large statures, have the 90th percentile standing height and the 90th percentile body mass (male: 1.86 m and 108 kg; female: 1.72 m and 94 kg), and organ masses ~25% heavier than those of MRCPs.

15.2.2 Calculation of Organ Absorbed Dose Coefficients for Industrial Radiography Sources

The most commonly used industrial radiography sources of the 192Ir and 60Co radioisotopes were simulated as point sources placed near the phantoms. 192Ir emits gamma rays up to 0.820 MeV with mean energy of 0.377 MeV, whereas 60Co emits 1.33 and 1.17 MeV gamma rays. The point sources were assumed to be located at three different distances (0.005, 0.1, and 0.3 m) in four directions (anterior, posterior, right lateral, and left lateral) and at five locations along the height of the phantom (ground, middle thigh and lower, middle, and upper torso). In addition, for the lower torso level, three longer distances (1, 1.5, and 3 m) were considered for the four directions. The source distances used in the calculations are the distances from the phantom surface to the sources, except for the anterior and posterior directions at the ground and middle thigh levels, for which the source distances were measured from the center of an imaginary segment tangent to the surfaces of feet or left and right legs at the given level.
The doses of organs/tissues were calculated as organ/tissue-averaged absorbed dose per radioactive decay (Gy s−1 Bq−1), by using the Geant4 Monte Carlo code [17]. For the simulations, we used a range cut of 5 μm for secondary electrons and photons, and the Livermore physics model (G4EmLivermorePhysics), which is provided by Geant4 for the transportation of electrons and photons with the energies ranging from 250 eV to 1 GeV. The statistical errors of the calculated values were less than 5% for all cases. The red bone marrow (RBM) DCs were calculated by using the fluence-to-absorbed dose response functions provided in Annex D of ICRP Publication 116 [22] in order to consider the microscopic structure of bone geometry for different skeletal regions.
Note that the DCs in the present study (assuming point sources) were calculated without considering the exact source geometry. In order to allow users to consider the self-shielding effect of the sources, source self-shielding factors were additionally calculated by investigating the ratio of DCs for the spherical volume sources enclosed by capsule material to those for the bare point sources. For this purpose, combinations of four different thicknesses of radioactive material (1, 2, 3, and 4 mm) and two different thicknesses of capsule wall (1 and 2 mm) were considered, which cover the geometries of most radiography sources. The composition of the capsule material was assumed to correspond to that of 316 L stainless steel.

15.3 Results and Discussion

DCs for organ absorbed dose of the reference and 10th and 90th percentile phantoms were produced for two industrial radiography sources (192Ir and 60Co) placed at 72 different locations around the phantoms. The analysis of the calculated DCs for industrial radiography sources showed that the DCs generally tend to decrease with an increase in the source distance, while the opposite tendency was also observed for some cases. Figure 15.2, for example, shows the DCs for the lungs of the adult male MRCP for 60Co. It can be seen that the DCs at the source levels of the upper, middle, and lower torso decrease with the increase of the source distance, whereas the opposite behavior is observed at the other source levels (i.e., the middle thigh and ground). This opposite trend is due to the different factors influencing the DCs of the lungs. For the first group of source levels (i.e., the upper, lower, and middle torso), the lung DCs are mainly influenced by the change of distance between the lungs and source (i.e., the inverse-square-law attenuation), rather than that of the shielding effect of the intervening tissue (i.e., the exponential-law attenuation). On the other hand, for the second group of source levels (i.e., the middle thigh and ground), which are much further away from the level of the lungs compared to the first group, the lung DCs are mainly influenced by the change of the shielding effect of the intervening tissue, which significantly decreases with the increase of the source distance. Similar trends were also observed for the DCs of the brain, which tend to increase with increasing source distance for the height levels of ground, middle thigh, and lower torso.
Our analysis also showed that the DC difference due to different body sizes tends to be larger when the source is closer to the body. When the source distance is shorter than 1 m, in general, the DCs of the 90th percentile phantoms were significantly smaller than those of the MRCPs; the maximum difference was a factor of ~8 for the female brain for the 192Ir source located at 0.3 m from the phantom surface in the right-lateral direction at the ground level. The DCs of the 10th percentile phantoms were significantly larger than those of the MRCPs; the maximum difference was 2.3 times for the female brain for the 192Ir source located at 0.1 m from the phantom surface in the left-lateral direction at the ground level. It should be noted that, for both cases, maximum differences were not found at the shortest source distance (0.005 m), because in these cases the source particles could directly reach the head only for the smaller phantoms, while this was not the case for the other phantoms.
On the other hand, for the longer source distances, the DC differences due to the different body sizes were small, i.e., less than 20–30% for both genders and all organs/tissues, source directions, and isotopes considered in the present study. Figure 15.3 shows the DCs of the large intestine of the adult male MRCP for 192Ir sources in the four directions at the lower torso level as a function of the source distance, along with those of the 10th and 90th percentile phantoms. It can be seen that the DC differences among the different body size phantoms decrease with an increase in the source distance. This trend indicates that the DCs among the different body sizes are influenced mainly by the change of the distance from the target organs/tissues to the source, rather than that of the shielding effect of the intervening tissue.
Finally, the DCs of MRCPs were generally found to be closer to the DCs of 10th percentile phantom than those of 90th percentile phantom. This is mainly because the MRCPs do not exactly correspond to the 50th percentile in body weight; the adult male and female MRCPs correspond to ~30th and ~40th percentile in body weight, respectively, which are closer to 10th percentile than 90th percentile. It can also be seen that the body size effect tends to be less significant for sources in the posterior direction as opposed to those in the other directions (anterior and left and right laterals). This can be explained by the fact that the change of the residual soft tissue (i.e., adipose tissue) among the different body size phantoms in the back is smaller than that in the other sides, especially in the abdominal region [2325].
Table 15.1 shows the source self-shielding factors of 192Ir and 60Co, by which the DCs could be multiplied according to the different thicknesses of the radioactive material (1, 2, 3, and 4 mm) and capsule wall (1 and 2 mm). It can be seen that while the self-shielding effects of 60Co sources are less than 10% in all cases, the self-shielding effects of 192Ir sources are up to 56.4%, which is due to the extremely high density of iridium (22.5 g cm−3). This implies that source self-shielding factors should be considered, especially for 192Ir sources.
Table 15.1
Source self-shielding factors for 192Ir and 60Co
Capsule-wall thickness
Radioactive material thickness
1 mm
2 mm
3 mm
4 mm
192Ir
60Co
192Ir
60Co
192Ir
60Co
192Ir
60Co
1 mm
0.840
0.972
0.717
0.965
0.627
0.958
0.556
0.949
2 mm
0.803
0.953
0.694
0.947
0.606
0.938
0.536
0.929

15.4 Conclusion

In the present study, a comprehensive data set of organ absorbed dose coefficients (DC) for industrial radiography sources of two radioisotopes (192Ir and 60Co), placed in 72 different source locations were obtained by performing Monte Carlo simulations with the mesh-type reference computational phantoms (MRCPs) and 10th and 90th percentile phantoms. In addition, the characteristics of the DC data were investigated, thereby finding that the body size indeed significantly influences the DCs, especially when the sources are closer than 1 m to the human body, which is often the case for accidents involving industrial radiography sources. The DC data are expected to be used as an initial tool for the rapid dose estimation of individuals accidentally exposed to industrial radiography sources. A full set of the DCs will appear in a forthcoming ICRP Publication prepared by the ICRP Task Group 103 of Committee 2.

Acknowledgments

The authors would like to thank Dr. Wi-Ho Ha and Mr. Han Sung Kim of Korea Institute of Radiological & Medical Sciences (KIRAMS) for helpful discussions. This work was supported by the Nuclear Safety Research Development (NSR&D) Program through Korea Foundation of Nuclear Safety (KoFONS), funded by the Nuclear Safety and Security Commission (NSSC), and additionally by the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (Project No.: 1705006, 2016R1D1A1A09916337). Two of the authors (Haegin Han and Chansoo Choi) were supported by the Global Ph.D. Fellowship program (Project No.: NRF-2018H1A2A1059767 and NRF-2017H1A2A1046391).
Open Access This chapter is licensed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.
The images or other third party material in this chapter are included in the chapter's Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the chapter's Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.
Literatur
1.
Zurück zum Zitat IAEA. (2011). IAEA Safety Standards No. SSG-11, Radiation safety in industrial radiography. IAEA. (2011). IAEA Safety Standards No. SSG-11, Radiation safety in industrial radiography.
2.
Zurück zum Zitat IAEA. (1998). Safety Reports Series No. 7, Lessons learned from accidents in industrial radiography. IAEA. (1998). Safety Reports Series No. 7, Lessons learned from accidents in industrial radiography.
3.
Zurück zum Zitat Lima, C. M. A., Lima, A. R., Degenhardt, A. L., et al. (2015). Reconstructive dosimetry for cutaneous radiation syndrome. Brazilian Journal of Medical and Biological Research, 48, 895.CrossRef Lima, C. M. A., Lima, A. R., Degenhardt, A. L., et al. (2015). Reconstructive dosimetry for cutaneous radiation syndrome. Brazilian Journal of Medical and Biological Research, 48, 895.CrossRef
4.
Zurück zum Zitat Donnelly, E. H., Nemhauser, J. B., Smith, J. M., et al. (2010). Acute radiation syndrome: assessment and management. Southern Medical Journal, 103, 541.CrossRef Donnelly, E. H., Nemhauser, J. B., Smith, J. M., et al. (2010). Acute radiation syndrome: assessment and management. Southern Medical Journal, 103, 541.CrossRef
5.
Zurück zum Zitat Gougelet, R. M., Nicolalde, R. J., Rea, M., & Swartz, H. M. (2010). The View from the Tranches Part 1: Emergency Medical Response Plans and the Need for EPR Screening. Health Physics, 98, 118.CrossRef Gougelet, R. M., Nicolalde, R. J., Rea, M., & Swartz, H. M. (2010). The View from the Tranches Part 1: Emergency Medical Response Plans and the Need for EPR Screening. Health Physics, 98, 118.CrossRef
6.
Zurück zum Zitat Rea, M. E., Gougelet, R. M., Nicolalde, R. J., et al. (2010). Proposed triage categories for large-scale radiation incidents using high-accuracy biodosimetry methods. Health Physics, 98, 136.CrossRef Rea, M. E., Gougelet, R. M., Nicolalde, R. J., et al. (2010). Proposed triage categories for large-scale radiation incidents using high-accuracy biodosimetry methods. Health Physics, 98, 136.CrossRef
7.
Zurück zum Zitat Cerezo, L. (2011). Radiation accidents and incidents. What do we know about the medical management of acute radiation syndrome? Reports of Practical Oncology and Radiotherapy, 16, 119.CrossRef Cerezo, L. (2011). Radiation accidents and incidents. What do we know about the medical management of acute radiation syndrome? Reports of Practical Oncology and Radiotherapy, 16, 119.CrossRef
8.
Zurück zum Zitat Ainsbury, E. A., Bakhanova, E., Barquinero, J. F., et al. (2011). Review of retrospective dosimetry techniques for external ionising radiation exposures. Radiation Protection Dosimetry, 147, 573.CrossRef Ainsbury, E. A., Bakhanova, E., Barquinero, J. F., et al. (2011). Review of retrospective dosimetry techniques for external ionising radiation exposures. Radiation Protection Dosimetry, 147, 573.CrossRef
9.
Zurück zum Zitat Swartz, H. M., Williams, B. B., & Flood, A. B. (2014). Overview of the principles and practice of biodosimetry. Radiation and Environmental Biophysics, 53, 221.CrossRef Swartz, H. M., Williams, B. B., & Flood, A. B. (2014). Overview of the principles and practice of biodosimetry. Radiation and Environmental Biophysics, 53, 221.CrossRef
10.
Zurück zum Zitat Kulka, U., Abend, M., Ainsbury, E., et al. (2017). RENEB-Running the European Network of biological dosimetry and physical retrospective dosimetry. International Journal of Radiation Biology, 93, 2.CrossRef Kulka, U., Abend, M., Ainsbury, E., et al. (2017). RENEB-Running the European Network of biological dosimetry and physical retrospective dosimetry. International Journal of Radiation Biology, 93, 2.CrossRef
11.
Zurück zum Zitat Lu, W., Wu, Z., Qiu, R., et al. (2017). Physical dosimetric reconstruction of a radiological accident at Nanjing (China) for clinical treatment using THUdose. Health Physics, 113, 327.CrossRef Lu, W., Wu, Z., Qiu, R., et al. (2017). Physical dosimetric reconstruction of a radiological accident at Nanjing (China) for clinical treatment using THUdose. Health Physics, 113, 327.CrossRef
12.
Zurück zum Zitat Clairand, I., Trompier, F., & Bottollier-Depois, J. F. (2006). EX vivo ESR measurements assiciated with Monte Carlo calculations for accident dosimetry: application to the 2001 Georgian accident. Radiation Protection Dosimetry, 119, 500.CrossRef Clairand, I., Trompier, F., & Bottollier-Depois, J. F. (2006). EX vivo ESR measurements assiciated with Monte Carlo calculations for accident dosimetry: application to the 2001 Georgian accident. Radiation Protection Dosimetry, 119, 500.CrossRef
13.
Zurück zum Zitat Sullivan, J. M., Prasanna, P. G. S., Grace, M. B., et al. (2013). Assessment of biodosimetry methods for a mass-casualty radiological incident: medical response and management considerations. Health Physics, 105, 540.CrossRef Sullivan, J. M., Prasanna, P. G. S., Grace, M. B., et al. (2013). Assessment of biodosimetry methods for a mass-casualty radiological incident: medical response and management considerations. Health Physics, 105, 540.CrossRef
14.
Zurück zum Zitat Ainsbury, E. A., Badie, C., Barnard, S., et al. (2017). Integration of new biological and physical retrospective dosimetry methods into EU emergency response plans-joint RENEB and EURADOS inter-laboratory comparisons. International Journal of Radiation Biology, 93, 99.CrossRef Ainsbury, E. A., Badie, C., Barnard, S., et al. (2017). Integration of new biological and physical retrospective dosimetry methods into EU emergency response plans-joint RENEB and EURADOS inter-laboratory comparisons. International Journal of Radiation Biology, 93, 99.CrossRef
16.
Zurück zum Zitat Lee, H., Yeom, Y. S., Thang, T. N., et al. (2017). Transactions of the Korean Association for Radiation Protection Autumn Meeting. Lee, H., Yeom, Y. S., Thang, T. N., et al. (2017). Transactions of the Korean Association for Radiation Protection Autumn Meeting.
17.
Zurück zum Zitat Allison, J., Amako, K., Apostolakis, J., et al. (2016). Recent developments in Geant4. Nuclear Instruments and Methods in Physics Research Section A, 835, 186.CrossRef Allison, J., Amako, K., Apostolakis, J., et al. (2016). Recent developments in Geant4. Nuclear Instruments and Methods in Physics Research Section A, 835, 186.CrossRef
18.
Zurück zum Zitat ICRP, ICRP Publication 110, Adult Reference Computational Phantoms, 2009. ICRP, ICRP Publication 110, Adult Reference Computational Phantoms, 2009.
19.
Zurück zum Zitat Kim, C. H., Jeong, J. H., Bolch, W. E., et al. (2011). A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation. Physics in Medicine and Biology, 56, 3137.CrossRef Kim, C. H., Jeong, J. H., Bolch, W. E., et al. (2011). A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation. Physics in Medicine and Biology, 56, 3137.CrossRef
20.
Zurück zum Zitat Yeom, Y. S., Jeong, J. H., Han, H. C., et al. (2014). Tetrahedral-mesh-based computational human phantom for fast Monte Carlo dose calculations. Physics in Medicine and Biology, 59, 3173.CrossRef Yeom, Y. S., Jeong, J. H., Han, H. C., et al. (2014). Tetrahedral-mesh-based computational human phantom for fast Monte Carlo dose calculations. Physics in Medicine and Biology, 59, 3173.CrossRef
21.
Zurück zum Zitat ICRP, ICRP Publication 89, Basic Anatomical and Physiological Data for Use in Radiological Protection: Reference Values, 2002. ICRP, ICRP Publication 89, Basic Anatomical and Physiological Data for Use in Radiological Protection: Reference Values, 2002.
22.
Zurück zum Zitat ICRP, ICRP Publication 116, Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures, 2010. ICRP, ICRP Publication 116, Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures, 2010.
23.
Zurück zum Zitat Borkan, G. A., Gerzof, S. G., Robbins, A. H., et al. (1982). Assessment of abdominal fat content by computed tomography. The American Journal of Clinical Nutrition, 36, 172.CrossRef Borkan, G. A., Gerzof, S. G., Robbins, A. H., et al. (1982). Assessment of abdominal fat content by computed tomography. The American Journal of Clinical Nutrition, 36, 172.CrossRef
24.
Zurück zum Zitat Dixon, A. K. (1983). Abdominal fat assessed by computed tomography: sex difference in distribution. Clinical Radiology, 34, 189.CrossRef Dixon, A. K. (1983). Abdominal fat assessed by computed tomography: sex difference in distribution. Clinical Radiology, 34, 189.CrossRef
25.
Zurück zum Zitat Grauer, W. O., Moss, A. A., Cann, C. E., et al. (1984). Quantification of body fat distribution in the abdomen using computed tomography. The American Journal of Clinical Nutrition, 39, 631.CrossRef Grauer, W. O., Moss, A. A., Cann, C. E., et al. (1984). Quantification of body fat distribution in the abdomen using computed tomography. The American Journal of Clinical Nutrition, 39, 631.CrossRef
Metadaten
Titel
Dose Coefficients for Use in Rapid Dose Estimation in Industrial Radiography Accidents
verfasst von
Haegin Han
Yeon Soo Yeom
Chansoo Choi
Hanjin Lee
Bangho Shin
Xujia Zhang
Rui Qiu
Nina Petoussi-Henss
Chan Hyeong Kim
Copyright-Jahr
2019
DOI
https://doi.org/10.1007/978-3-030-21293-3_15