Skip to main content
Erschienen in: Fire Technology 1/2015

01.01.2015

Evaluating Fire Service Escape Ropes at Elevated Temperatures and Fire Conditions

verfasst von: Gavin P. Horn, Julien Chaussidon, Mark Obstalecki, Daniel A. Martin, Peter Kurath, Robert G. Backstrom, Stephen Kerber

Erschienen in: Fire Technology | Ausgabe 1/2015

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The tools and equipment that firefighters carry on the fireground must be able to perform in the thermal conditions for which they may be deployed and utilized. Escape rope systems, which may be utilized by firefighters requiring emergency escape from an elevated position due to rapidly evolving fire conditions, are potentially life critical pieces of equipment. However, until recently traditional standardized tests required that the material properties of the rope only be evaluated at room temperature. In this study, traditional materials testing instruments were modified to quantify the capability of firefighter escape ropes to perform in the thermal conditions for which they may be deployed and utilized. These instruments have shown that at temperatures as low as 100°C, the strength of each rope was significantly reduced and at temperatures as low as 300°C, even the all aramid rope strength reduced by more than 50 %. Furthermore, this study has provided the first means of reliably and repeatably determining the available safe on-rope time. For temperature conditions comparable to those in typical structure fires, where the compartment of egress has flashed over, even the strongest ropes with the highest temperature resistance can only be expected to provide a maximum of 90 s of protection prior to failure. Pilot testing with a protective sheath concept has demonstrated a promising potential for improvement in performance.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat NFPA (2006) NFPA 1983: standard on life safety rope and equipment for emergency services, 2006 edn. National Fire Protection Association, Quincy. NFPA (2006) NFPA 1983: standard on life safety rope and equipment for emergency services, 2006 edn. National Fire Protection Association, Quincy.
2.
Zurück zum Zitat Firefighter’s handbook: essentials of firefighting and emergency response, 2nd edn. Delmar Thomson Learning, Clifton Park (2004). Firefighter’s handbook: essentials of firefighting and emergency response, 2nd edn. Delmar Thomson Learning, Clifton Park (2004).
3.
Zurück zum Zitat Watson P (1993) Selecting lifesaving rope. Fire Eng 146(9):14–16. Watson P (1993) Selecting lifesaving rope. Fire Eng 146(9):14–16.
6.
Zurück zum Zitat Greiff JS (2001) Performance tests of personal escape rope systems. Fire Eng. 154 (5):45–60. Greiff JS (2001) Performance tests of personal escape rope systems. Fire Eng. 154 (5):45–60.
7.
Zurück zum Zitat NFPA (2012) NFPA 1983: standard on life safety rope and equipment for emergency services, 2012 edn. National Fire Protection Association, Quincy. NFPA (2012) NFPA 1983: standard on life safety rope and equipment for emergency services, 2012 edn. National Fire Protection Association, Quincy.
8.
Zurück zum Zitat Fontenot N, Stenvers D, Gilmore J, Solomon A, van Berkel B, Grabandt O, Kong D (2009) Use of synthetic rope in high-temperature or fire environments, MTS/IEEE Biloxi—marine technology for our future: global and local challenges, OCEANS 2009, art. No. 5422343. Fontenot N, Stenvers D, Gilmore J, Solomon A, van Berkel B, Grabandt O, Kong D (2009) Use of synthetic rope in high-temperature or fire environments, MTS/IEEE Biloxi—marine technology for our future: global and local challenges, OCEANS 2009, art. No. 5422343.
11.
Zurück zum Zitat ASTM International (2012) ASTM I119-12a: standard test method for fire tests of building construction and materials. ASTM, West Conshohocken, PA. ASTM International (2012) ASTM I119-12a: standard test method for fire tests of building construction and materials. ASTM, West Conshohocken, PA.
12.
Zurück zum Zitat The Cordage Institute (2007). CI 1801: low stretch/static kernmantle safety rope. Cordage Institute, Wayne, PA. The Cordage Institute (2007). CI 1801: low stretch/static kernmantle safety rope. Cordage Institute, Wayne, PA.
13.
Zurück zum Zitat Obstalecki M, Chaussidon J, Kurath P, Horn GP (2011) Prediction of dynamic forces in fire service escape scenarios. Conf Proc Soc Exp Mech Ser 1:179–186.CrossRef Obstalecki M, Chaussidon J, Kurath P, Horn GP (2011) Prediction of dynamic forces in fire service escape scenarios. Conf Proc Soc Exp Mech Ser 1:179–186.CrossRef
Metadaten
Titel
Evaluating Fire Service Escape Ropes at Elevated Temperatures and Fire Conditions
verfasst von
Gavin P. Horn
Julien Chaussidon
Mark Obstalecki
Daniel A. Martin
Peter Kurath
Robert G. Backstrom
Stephen Kerber
Publikationsdatum
01.01.2015
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 1/2015
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-013-0373-2

Weitere Artikel der Ausgabe 1/2015

Fire Technology 1/2015 Zur Ausgabe