Abstract

Water-mist technology provides efficient fire suppression for compartments while minimizing water usage. Even with the many advantages of water mist systems, there is still room for improvement. Water mist systems have demonstrated effectiveness at suppressing flammable liquids (Class B) fires in compartments. However, an especially challenging fire suppression scenario for water mist systems is the small Class B fire. This scenario is often realized after a large fire has been reduced in size or ‘controlled’ by water mist. The small fire scenario is challenging because a small fire may not be able to generate enough vaporized water to displace sufficient oxygen for complete extinction. It should also be noted that even if the Class B fire is extinguished with a water mist system, re-ignition from the hot surrounding surfaces may occur at any time. In the present work, an additive is introduced into the water supply and its effect on the water mist suppression performance is studied. This ForafacTM additive is a specific formulation, which includes fluorinated surfactants for creating a robust fire suppression foam. The enhanced suppressant exiting the mist nozzle is dispersed in the form of small droplets (not as a continuous foam) similar to a pure water mist spray. However, these droplets create a foam blanket on the surface of the fire, which acts to isolate the fuel from the air. With this formulation, the efficiency of the water mist system is improved even on small fires and most importantly the re-ignition of class B fires is prevented.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Fußnoten
1
European parliament legislative resolution on the proposal for a directive of the European Parliament and of the council relating to restrictions on the marketing and use of perflurooctane sulfonates (amendment of council directive 76/769/EEC).
 
Literatur
1.
Zurück zum Zitat Committee on Assessment of Fire Suppression Substitutes and Alternatives to Halon, Naval Studies Board, Commission on Physical Sciences, Mathematics, and Applications, National Research Council (1997) Fire suppression substitutes and alternatives to halon for U.S. Navy applications. National Academy Press, Washington, DC Committee on Assessment of Fire Suppression Substitutes and Alternatives to Halon, Naval Studies Board, Commission on Physical Sciences, Mathematics, and Applications, National Research Council (1997) Fire suppression substitutes and alternatives to halon for U.S. Navy applications. National Academy Press, Washington, DC
2.
Zurück zum Zitat NFPA (1996) 750: standard on the installation of water mist fire protection systems. National Fire Protection Association, Quincy, MA NFPA (1996) 750: standard on the installation of water mist fire protection systems. National Fire Protection Association, Quincy, MA
4.
Zurück zum Zitat Notarianni KA (1994) Water mist fire suppression systems. In: Proceedings of the technical symposium on halon alternatives. Knoxville, TN Notarianni KA (1994) Water mist fire suppression systems. In: Proceedings of the technical symposium on halon alternatives. Knoxville, TN
6.
Zurück zum Zitat Weaire D, Hutzler S (1999) The physics of foams. Clarendon Press, Oxford Weaire D, Hutzler S (1999) The physics of foams. Clarendon Press, Oxford
8.
Zurück zum Zitat Kim AK, Dlugogorski DS DZ, Mawhinney JR (1994) The effect of foam additives on the fire suppression efficiency of water mist. In: Proceedings of the halon options technical working conference. Albuqerque, New Mexico Kim AK, Dlugogorski DS DZ, Mawhinney JR (1994) The effect of foam additives on the fire suppression efficiency of water mist. In: Proceedings of the halon options technical working conference. Albuqerque, New Mexico
9.
Zurück zum Zitat Pabon M (2005) New additive for water mist systems on class B fires: toxicological study on breathable particles. In: 6th international water mist association conference. Berlin, Germany Pabon M (2005) New additive for water mist systems on class B fires: toxicological study on breathable particles. In: 6th international water mist association conference. Berlin, Germany
10.
Zurück zum Zitat Arridson M, Hertzberg T (2003) The Vinnova water mist research project: a description of the 500 m3 machinery spaces. SP Swed Natl Test Res Inst SP 19 Arridson M, Hertzberg T (2003) The Vinnova water mist research project: a description of the 500 m3 machinery spaces. SP Swed Natl Test Res Inst SP 19
11.
Zurück zum Zitat Pepi JS (1995) Performance evaluation of low-pressure water mist system in a marine machinery space with open doorway. In: Proceedings of the halon options technical working conference. Albuqerque, New Mexico Pepi JS (1995) Performance evaluation of low-pressure water mist system in a marine machinery space with open doorway. In: Proceedings of the halon options technical working conference. Albuqerque, New Mexico
12.
Zurück zum Zitat Ural EA, Bill RG (1995) Fire suppression performance testing of water mist systems for combustion turbine enclosures. In: Proceedings of the halon options technical working conference. Albuqerque, New Mexico Ural EA, Bill RG (1995) Fire suppression performance testing of water mist systems for combustion turbine enclosures. In: Proceedings of the halon options technical working conference. Albuqerque, New Mexico
13.
Zurück zum Zitat UL2167: water mist for nozzles for fire protection service. Underwriters Laboratories, USA February 2004 UL2167: water mist for nozzles for fire protection service. Underwriters Laboratories, USA February 2004
Metadaten
Titel
Evaluation of Surfactant Enhanced Water Mist Performance
verfasst von
Georges LeFort
André W. Marshall
Martial Pabon
Publikationsdatum
01.09.2009
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 3/2009
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-008-0068-2

Weitere Artikel der Ausgabe 3/2009

Fire Technology 3/2009 Zur Ausgabe