Evaluation of the Power Generated by Ultrasonic Shears Used in Laparoscopic Surgeries

verfasst von : I. P. H. Rosario, J. M. Maia

Erschienen in: XXVII Brazilian Congress on Biomedical Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Minimally invasive surgical procedures are in evidence and are, therefore, the major worldwide trend. They correspond to a great technological advance that aims to promote patient safety, minimizing complications and making possible some complex surgeries that were not possible to be performed in the past. Highly complex surgeries require the use of equipment that presents high precision in cutting biological tissues and that is also combined with cauterization, thus avoiding complications caused by hemorrhages and even infections. The objective of this work was to evaluate the power/intensity generated by ultrasonic shears used in surgical procedures. Twenty-five Harmonic Ace® shears—HAR36 were evaluated, with four handpieces coupled to eight different ETHICON GEN11 generators. The generators were configured to generate the Level 5 power, standard for cutting, Level 3, standard for coagulation and Level 1, also used for coagulation with greater efficiency. For each GEN11 configuration, the maximum generated power values were measured using an Ohmic Instruments UPM-DT-1 Ultrasound Power Meter. The expected value and standard deviations were calculated using EXCEL (Microsoft Corp.). The average powers generated for all evaluated devices were 1.08 ± 0.80 W for Level 1, 3.74 ± 2.28 W for Level 3 and 9.18 ± 3.32 W for Level 5. It was found that there is a 20-fold variation between the lowest and the highest power generated, showing the importance of implementing an adequate quality control protocol for these devices. It was also found that, even during the standard test of equipment, high levels of intensity are generated that can subject operators to risks if they do not take proper care, requiring adequate training of these professionals. Thus, to avoid risks to operators, this work suggests a safety protocol with the steps to be followed when activating the ultrasonic shears.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Fitzharris L (2017) The butchering art: Joseph Lister's quest to transform the grisly world of victorian medicine. PublisherFarrar, Straus and Giroux Fitzharris L (2017) The butchering art: Joseph Lister's quest to transform the grisly world of victorian medicine. PublisherFarrar, Straus and Giroux
3.
Zurück zum Zitat Amaral JF (1993) Laparoscopic application of an ultrasonically activated scalpel. Gastrointest Endosc Clin North Am. Amaral JF (1993) Laparoscopic application of an ultrasonically activated scalpel. Gastrointest Endosc Clin North Am.
4.
Zurück zum Zitat Chen C, Kallakuri S, Vedpathak A, Chimakurthy C, Cavanaugh J, Clymer J, Malaviya P (2012) The effects of ultrasonic and electrosurgery devices on nerve physiology. Br J Neurosurg 26(6):856–863 Chen C, Kallakuri S, Vedpathak A, Chimakurthy C, Cavanaugh J, Clymer J, Malaviya P (2012) The effects of ultrasonic and electrosurgery devices on nerve physiology. Br J Neurosurg 26(6):856–863
7.
Zurück zum Zitat Ethicon Endo-Surgery (2017) GEN11 Ethicon endo-surgery generator. LLC ©EES, LLC Ethicon Endo-Surgery (2017) GEN11 Ethicon endo-surgery generator. LLC ©EES, LLC
8.
Zurück zum Zitat Seehofer D, Mogl M, Boas-Knoop S, Unger J, Schirmeier A, Chopra S, Eurich D (2012) Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instruments. Surg Endosc 26(9):2541–2549 Seehofer D, Mogl M, Boas-Knoop S, Unger J, Schirmeier A, Chopra S, Eurich D (2012) Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instruments. Surg Endosc 26(9):2541–2549
9.
Zurück zum Zitat Vakharia O, Messerly J, Stefanchik D, Smolik S (2016) Ultrasonic surgical instruments with distally positioned jaw assembles. Patent Application Publication. Ethicon Endo-Surgery, LLC, Guaynabo, PR (US), Pub. No.: US 2016/0346001 Vakharia O, Messerly J, Stefanchik D, Smolik S (2016) Ultrasonic surgical instruments with distally positioned jaw assembles. Patent Application Publication. Ethicon Endo-Surgery, LLC, Guaynabo, PR (US), Pub. No.: US 2016/0346001
10.
Zurück zum Zitat Nanashima A, Abo T, Arai J, Takagi K, Matsumoto H, Takeshita H, Tsuchiya T, Nagayasu T (2013) Usefulness of vessel-sealing devices combined with crush clamping method for hepatectomy: a retrospective cohort study. Int J Surg. 11(9):891–897CrossRef Nanashima A, Abo T, Arai J, Takagi K, Matsumoto H, Takeshita H, Tsuchiya T, Nagayasu T (2013) Usefulness of vessel-sealing devices combined with crush clamping method for hepatectomy: a retrospective cohort study. Int J Surg. 11(9):891–897CrossRef
11.
Zurück zum Zitat Hadjicostis A, Hottinger C, Rosen J, Wells P (1984) Ultrasonic Transducer materials for medical applications. Ferroelectrics 60(1):107–126CrossRef Hadjicostis A, Hottinger C, Rosen J, Wells P (1984) Ultrasonic Transducer materials for medical applications. Ferroelectrics 60(1):107–126CrossRef
12.
Zurück zum Zitat Hekkenberg R, Reibold R, Zeqiri B (1994) Development of standard measurement methods for essential properties of ultrasound therapy equipment. Ultrasound Med Biol. 20(1):83–98CrossRef Hekkenberg R, Reibold R, Zeqiri B (1994) Development of standard measurement methods for essential properties of ultrasound therapy equipment. Ultrasound Med Biol. 20(1):83–98CrossRef
Metadaten
Titel
Evaluation of the Power Generated by Ultrasonic Shears Used in Laparoscopic Surgeries
verfasst von
I. P. H. Rosario
J. M. Maia
Copyright-Jahr
2022
DOI
https://doi.org/10.1007/978-3-030-70601-2_318

Neuer Inhalt