Skip to main content
Erschienen in: Experimental Mechanics 1/2020

16.10.2019 | Research paper

Experimental Evaluation of Vertebral Strain in Lumbar Total Disc Replacement

verfasst von: A. Semitela, F. Fonseca, A.M.G. Completo

Erschienen in: Experimental Mechanics | Ausgabe 1/2020

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Total disk replacement (TDR) has met considerable reluctance from the medical community, mainly in the United States, because the insurance companies have refused to reimburse surgeons for fear of delayed complications, revisions and unknown secondary costs. Typical long-term vertebrae-implant related structural complications include subsidence, migration, implant displacement, endplate fracture, wear and loosening. Intervertebral disc implant size, shape, position, endplate removal and compressive strength of trabecular bone further affect the risk of implant subsidence and loosening. The aim of the present study is to understand the combined effects of the different depth positioning of the ProDisc-L implant and endplate removal during surgery on the vertebral bone strain behaviour. Manufactured synthetic spinal L3-L4 segments were used to experimentally predict vertebrae cortex strain behaviour for different depth implant positioning and endplate thickness removal. In addition, validated finite element models were developed to assess the structural behaviour of cancellous-bone. Measured cortex strains showed significant differences relative to the intact vertebra for the most extreme depth implant positioning. The endplate thickness reduction tends to decrease significantly compressive cortex strains for all strain gauges. A two- to three-fold cancellous-bone strain increase occurs when more than 50% of the endplate thickness is removed, independently of the depth implant position. It is concluded that the implanted strain distribution that better fits intact vertebra strain behaviour is achieved when the depth centred implant position is combined with a partial endplate thickness removal.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Sandhu F, Blumenthal S, Grunch B, Kimball B, Ferko N, Hollmann S (2017) Barriers to and budget impact of lumbar Total disc replacement utilization. Spine. 42(Suppl 24):S112–S114CrossRef Sandhu F, Blumenthal S, Grunch B, Kimball B, Ferko N, Hollmann S (2017) Barriers to and budget impact of lumbar Total disc replacement utilization. Spine. 42(Suppl 24):S112–S114CrossRef
2.
Zurück zum Zitat Hart RA, DePasse JM, Daniels AH (2017) Failure to launch: what the rejection of lumbar Total disk replacement tells us about American spine surgery. Clin Spine Surg 30:E759–E764CrossRef Hart RA, DePasse JM, Daniels AH (2017) Failure to launch: what the rejection of lumbar Total disk replacement tells us about American spine surgery. Clin Spine Surg 30:E759–E764CrossRef
3.
Zurück zum Zitat Siepe CJ, Heider F, Wiechert K, Hitzl W, Ishak B, Mayer MH (2014) Mid- to long-term results of total lumbar disc replacement: a prospective analysis with 5- to 10-year follow-up. Spine J 14:1417–1431CrossRef Siepe CJ, Heider F, Wiechert K, Hitzl W, Ishak B, Mayer MH (2014) Mid- to long-term results of total lumbar disc replacement: a prospective analysis with 5- to 10-year follow-up. Spine J 14:1417–1431CrossRef
4.
Zurück zum Zitat Garcia R Jr, Yue JJ, Blumenthal S, Coric D, Patel VV, Leary SP, Dinh DH, Buttermann GR, Deutsch H, Girardi F, Billys J, Miller LE (2015) Lumbar Total disc replacement for Discogenic low Back pain: two-year outcomes of the activL multicenter randomized controlled IDE clinical trial. Spine. 40:1873–1881CrossRef Garcia R Jr, Yue JJ, Blumenthal S, Coric D, Patel VV, Leary SP, Dinh DH, Buttermann GR, Deutsch H, Girardi F, Billys J, Miller LE (2015) Lumbar Total disc replacement for Discogenic low Back pain: two-year outcomes of the activL multicenter randomized controlled IDE clinical trial. Spine. 40:1873–1881CrossRef
5.
Zurück zum Zitat Salzmann SN, Plais N, Shue J, Girardi FP (2017) Lumbar disc replacement surgery-successes and obstacles to widespread adoption. Curr Rev Musculoskelet Med 10:153–159CrossRef Salzmann SN, Plais N, Shue J, Girardi FP (2017) Lumbar disc replacement surgery-successes and obstacles to widespread adoption. Curr Rev Musculoskelet Med 10:153–159CrossRef
6.
Zurück zum Zitat Formica M, Divano S, Cavagnaro L, Basso M, Zanirato A, Formica C, Felli L (2017) Lumbar total disc arthroplasty: outdated surgery or here to stay procedure? A systematic review of current literature. J Orthop Traumatol 18:197–215CrossRef Formica M, Divano S, Cavagnaro L, Basso M, Zanirato A, Formica C, Felli L (2017) Lumbar total disc arthroplasty: outdated surgery or here to stay procedure? A systematic review of current literature. J Orthop Traumatol 18:197–215CrossRef
7.
Zurück zum Zitat Lee CK (2007) Osteopenia and total disc prosthesis subsidence: inclusion/exclusion criteria for total disc replacement. SAS J 1:82–84CrossRef Lee CK (2007) Osteopenia and total disc prosthesis subsidence: inclusion/exclusion criteria for total disc replacement. SAS J 1:82–84CrossRef
8.
Zurück zum Zitat Auerbach JD, Ballester CM, Hammond F, Carine ET, Balderston RA, Elliott DM (2010) The effect of implant size and device keel on vertebral compression properties in lumbar total disc replacement. Spine J 10:333–340CrossRef Auerbach JD, Ballester CM, Hammond F, Carine ET, Balderston RA, Elliott DM (2010) The effect of implant size and device keel on vertebral compression properties in lumbar total disc replacement. Spine J 10:333–340CrossRef
9.
Zurück zum Zitat Oxland TR, Grant JP, Dvorak MF, Fisher CG (2003) Effects of endplate removal on the structural properties of the lower lumbar vertebral bodies. Spine 28:771–777 Oxland TR, Grant JP, Dvorak MF, Fisher CG (2003) Effects of endplate removal on the structural properties of the lower lumbar vertebral bodies. Spine 28:771–777
10.
Zurück zum Zitat Zigler J, Garcia R (2015) ISASS policy statement - lumbar artificial disc. Int J Spine Surg 9:7CrossRef Zigler J, Garcia R (2015) ISASS policy statement - lumbar artificial disc. Int J Spine Surg 9:7CrossRef
11.
Zurück zum Zitat Osterhoff G, Morgan EF, Shefelbine SJ, Karim L, McNamara LM, Augat P (2016) Bone mechanical properties and changes with osteoporosis. Injury. 47:S11–S20CrossRef Osterhoff G, Morgan EF, Shefelbine SJ, Karim L, McNamara LM, Augat P (2016) Bone mechanical properties and changes with osteoporosis. Injury. 47:S11–S20CrossRef
12.
Zurück zum Zitat Zhou SH, McCarthy ID, McGregor AH, Coombs RR, Hughes SP (2000) Geometrical dimensions of the lower lumbar vertebrae--analysis of data from digitised CT images. Eur Spine J 9:242–248CrossRef Zhou SH, McCarthy ID, McGregor AH, Coombs RR, Hughes SP (2000) Geometrical dimensions of the lower lumbar vertebrae--analysis of data from digitised CT images. Eur Spine J 9:242–248CrossRef
13.
Zurück zum Zitat Saraste H, Brostrom LA, Aparisi T, Axdorph G (1985) Radiographic measurement of the lumbar spine – a clinical and experimental study on man. Spine 10:236–241CrossRef Saraste H, Brostrom LA, Aparisi T, Axdorph G (1985) Radiographic measurement of the lumbar spine – a clinical and experimental study on man. Spine 10:236–241CrossRef
14.
Zurück zum Zitat Kemper AR, McNally C, Duma SM (2007) The influence of strain rate on the compressive stiffness properties of human lumbar intervertebral discs. Biomed Sci Instrum 43:176–181 Kemper AR, McNally C, Duma SM (2007) The influence of strain rate on the compressive stiffness properties of human lumbar intervertebral discs. Biomed Sci Instrum 43:176–181
15.
Zurück zum Zitat Smeathers JE, Joanes DN (1988) Dynamic compressive properties of human lumbar intervertebral joints: a comparison between fresh and thawed specimens. J Biomech 21:425–433CrossRef Smeathers JE, Joanes DN (1988) Dynamic compressive properties of human lumbar intervertebral joints: a comparison between fresh and thawed specimens. J Biomech 21:425–433CrossRef
16.
Zurück zum Zitat ASTM F2423-11 (2016) Standard guide for functional, kinematic, and Wear assessment of Total disc prostheses. ASTM International, West Conshohocken, PA ASTM F2423-11 (2016) Standard guide for functional, kinematic, and Wear assessment of Total disc prostheses. ASTM International, West Conshohocken, PA
17.
Zurück zum Zitat Prodisc-L (2017) Modular intervertebral disc prosthesis for stabilizing the lumbar spine and restoring the physiological range of motion – surgical technique DePuy Synthes Spine, a division of Synthes GmbH Prodisc-L (2017) Modular intervertebral disc prosthesis for stabilizing the lumbar spine and restoring the physiological range of motion – surgical technique DePuy Synthes Spine, a division of Synthes GmbH
18.
Zurück zum Zitat Completo A, Nascimento A, Ramos A, Simões J (2015) Failure analysis of C-5 after total disc replacement with ProDisc-C at 1 and 2 levels and in combination with a fusion cage: finite-element and biomechanical models. J Neurosurg Spine 22:639–646CrossRef Completo A, Nascimento A, Ramos A, Simões J (2015) Failure analysis of C-5 after total disc replacement with ProDisc-C at 1 and 2 levels and in combination with a fusion cage: finite-element and biomechanical models. J Neurosurg Spine 22:639–646CrossRef
19.
Zurück zum Zitat Polikeit A, Ferguson SJ, Nolte LP, Orr TE (2003) Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis. Eur Spine J 12:413–420CrossRef Polikeit A, Ferguson SJ, Nolte LP, Orr TE (2003) Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis. Eur Spine J 12:413–420CrossRef
20.
Zurück zum Zitat Goreham-Voss CM, Hyde PJ, Hall RM, Fisher J, Brown TD (2010) Cross-shear implementation in sliding-distance-coupled finite element analysis of wear in metal-on-polyethylene total joint arthroplasty: intervertebral total disc replacement as an illustrative application. J Biomech 43:1674–1681CrossRef Goreham-Voss CM, Hyde PJ, Hall RM, Fisher J, Brown TD (2010) Cross-shear implementation in sliding-distance-coupled finite element analysis of wear in metal-on-polyethylene total joint arthroplasty: intervertebral total disc replacement as an illustrative application. J Biomech 43:1674–1681CrossRef
21.
Zurück zum Zitat Completo A, Simões J, Fonseca F (2008) Experimental evaluation of strain shielding in distal femur in revision TKA. Exp Mech 48:817–824CrossRef Completo A, Simões J, Fonseca F (2008) Experimental evaluation of strain shielding in distal femur in revision TKA. Exp Mech 48:817–824CrossRef
22.
Zurück zum Zitat Completo A, Fonseca F, Simões JA, Ramos A, Relvas C (2012) A new press-fit stem concept to reduce the risk of end-of-stem pain at revision TKA: a pre-clinical study. Knee 19:537–542CrossRef Completo A, Fonseca F, Simões JA, Ramos A, Relvas C (2012) A new press-fit stem concept to reduce the risk of end-of-stem pain at revision TKA: a pre-clinical study. Knee 19:537–542CrossRef
23.
Zurück zum Zitat Pentecost R, Murray R, Brindley H Fatigue (1964) insufficiency, and pathological fractures. JAMA. 187:1001–1004 Pentecost R, Murray R, Brindley H Fatigue (1964) insufficiency, and pathological fractures. JAMA. 187:1001–1004
24.
Zurück zum Zitat Lambers F, Bouman A, Rimnac C, Hernandez C (2013) Microdamage caused by fatigue loading in human cancellous bone: relationship to reductions in bone biomechanical performance. PLoS One 8:e83662CrossRef Lambers F, Bouman A, Rimnac C, Hernandez C (2013) Microdamage caused by fatigue loading in human cancellous bone: relationship to reductions in bone biomechanical performance. PLoS One 8:e83662CrossRef
25.
Zurück zum Zitat Frost H (2003) Bone's mechanostat: a 2003 update. Anat Rec A Discov Mol Cell Evol Biol 275:1081–1101CrossRef Frost H (2003) Bone's mechanostat: a 2003 update. Anat Rec A Discov Mol Cell Evol Biol 275:1081–1101CrossRef
26.
Zurück zum Zitat Heiner A (2008) Structural properties of fourth-generation composite femurs and tibias. J Biomech 41:3282–3284CrossRef Heiner A (2008) Structural properties of fourth-generation composite femurs and tibias. J Biomech 41:3282–3284CrossRef
27.
Zurück zum Zitat Completo A, Duarte R, Fonseca F, Simões JA, Ramos A, Relvas C (2013) Biomechanical evaluation of different reconstructive techniques of proximal tibia in revision total knee arthroplasty: an in-vitro and finite element analysis. Clin Biomech 28:291–298CrossRef Completo A, Duarte R, Fonseca F, Simões JA, Ramos A, Relvas C (2013) Biomechanical evaluation of different reconstructive techniques of proximal tibia in revision total knee arthroplasty: an in-vitro and finite element analysis. Clin Biomech 28:291–298CrossRef
28.
Zurück zum Zitat Eswaran SK, Gupta A, Adams MF, Keaveny TM (2006) Cortical and trabecular load sharing in the human vertebral body. J Bone Miner Res 21:307–314CrossRef Eswaran SK, Gupta A, Adams MF, Keaveny TM (2006) Cortical and trabecular load sharing in the human vertebral body. J Bone Miner Res 21:307–314CrossRef
29.
Zurück zum Zitat Ferguson SJ, Steffen T (2003) Biomechanics of the aging spine. Eur Spine J 12(Suppl 2):S97–S103CrossRef Ferguson SJ, Steffen T (2003) Biomechanics of the aging spine. Eur Spine J 12(Suppl 2):S97–S103CrossRef
30.
Zurück zum Zitat Kerner J, Huiskes R, van Lenthe GH, Weinans H, van Rietbergen B, Engh CA, Amis AA (1999) Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling. J Biomech 32:695–703CrossRef Kerner J, Huiskes R, van Lenthe GH, Weinans H, van Rietbergen B, Engh CA, Amis AA (1999) Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling. J Biomech 32:695–703CrossRef
31.
Zurück zum Zitat Gross T, Rubin C (1995) Uniformity of resorptive bone loss induced by disuse. J Orthop Res 13:708–714CrossRef Gross T, Rubin C (1995) Uniformity of resorptive bone loss induced by disuse. J Orthop Res 13:708–714CrossRef
32.
Zurück zum Zitat Taylor M, Tanner K (1997) Fatigue failure of cancellous bone: a possible cause of implant migration and loosening. J-Bone-Joint-Surg Br 79:181–182CrossRef Taylor M, Tanner K (1997) Fatigue failure of cancellous bone: a possible cause of implant migration and loosening. J-Bone-Joint-Surg Br 79:181–182CrossRef
33.
Zurück zum Zitat Choi K, Goldstein SA (1992) A comparison of the fatigue behavior of human trabecular and cortical bone tissue. J Biomech 25:1371–1381CrossRef Choi K, Goldstein SA (1992) A comparison of the fatigue behavior of human trabecular and cortical bone tissue. J Biomech 25:1371–1381CrossRef
34.
Zurück zum Zitat Hongo M, Abe E, Shimada Y, Murai H, Ishikawa N, Sato K (1999) Surface strain distribution on thoracic and lumbar vertebrae under axial compression. The role in burst fractures. Spine. 24:1197–1202CrossRef Hongo M, Abe E, Shimada Y, Murai H, Ishikawa N, Sato K (1999) Surface strain distribution on thoracic and lumbar vertebrae under axial compression. The role in burst fractures. Spine. 24:1197–1202CrossRef
35.
Zurück zum Zitat Shah JS, Hampson WG, Jayson MI (1978) The distribution of surface strain in the cadaveric lumbar spine. J Bone Joint Surg Br 60:246–251CrossRef Shah JS, Hampson WG, Jayson MI (1978) The distribution of surface strain in the cadaveric lumbar spine. J Bone Joint Surg Br 60:246–251CrossRef
36.
Zurück zum Zitat Cristofolini L, Brandolini N, Danesi V, Juszczyk MM, Erani P, Viceconti M (2013) Strain distribution in the lumbar vertebrae under different loading configurations. Spine J 13:1281–1292CrossRef Cristofolini L, Brandolini N, Danesi V, Juszczyk MM, Erani P, Viceconti M (2013) Strain distribution in the lumbar vertebrae under different loading configurations. Spine J 13:1281–1292CrossRef
37.
Zurück zum Zitat Pollintine P, Dolan P, Tobias JH, Adams MA (2004) Intervertebral disc degeneration can lead to "stress-shielding" of the anterior vertebral body: a cause of osteoporotic vertebral fracture? Spine. 29:774–782CrossRef Pollintine P, Dolan P, Tobias JH, Adams MA (2004) Intervertebral disc degeneration can lead to "stress-shielding" of the anterior vertebral body: a cause of osteoporotic vertebral fracture? Spine. 29:774–782CrossRef
Metadaten
Titel
Experimental Evaluation of Vertebral Strain in Lumbar Total Disc Replacement
verfasst von
A. Semitela
F. Fonseca
A.M.G. Completo
Publikationsdatum
16.10.2019
Verlag
Springer US
Erschienen in
Experimental Mechanics / Ausgabe 1/2020
Print ISSN: 0014-4851
Elektronische ISSN: 1741-2765
DOI
https://doi.org/10.1007/s11340-019-00545-9

Weitere Artikel der Ausgabe 1/2020

Experimental Mechanics 1/2020 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.