Experimental Study of Bileaflet Mechanical Heart Valves

verfasst von : Eraldo Sales, M. Mazzetto, S. Bacht, I. A. Cestari

Erschienen in: XXVII Brazilian Congress on Biomedical Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Biological or mechanical heart valve prostheses are used as a treatment to replace failing native heart valves. The goal of this study is to investigate the hydrodynamic performance of small sizes bileaflet mechanical heart valves (BMHVs) considering their use to control flow direction on a pulsatile pediatric ventricular assist device (VAD) [1]. Small size BMHVs of 17, 19 mm were tested in vitro and compared to 23 mm prosthesis. Each prosthesis was placed on a pulse duplicator (4–90 bpm, 2.0–4.0 L/min flow range) and pressure and flow signals were recorded to determine pressure gradient, flow regurgitation and effective orifice area (EOA). Pressure gradients (maximum/minimum; mmHg) were (12.2/8.5), (8.4/6.3) and (8.2/5.8), for 17, 19 and 23-mm, respectively. Valve effective orifice areas (maximum/minimum; cm2) were (1.05/1.02), (1.37/1.24) and (1.55/1.35) for 17, 19 and 23-mm sizes, respectively. The regurgitation fractions (maximum/minimum; %) obtained were (6.91/5.29), (10.47/6.08), and (14.63/10.04), for 17, 19 and 23-mm sizes, respectively. The results suggest that the mechanical valves have adequate performance according to the requirements of the ISO 5840:2015 standards and that they can be used to effectively control flow direction on a pediatric pulsatile ventricular assist device.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Cestari IA, Mazzetto M, Oyama HT, Bacht S, Jatene MB, Cestari IN, Jatene FB (2019) Design and hydrodynamic performance of a pediatric pulsatile pump. In: Costa-Felix R, Machado J, Alvarenga A (eds) Proceedings on 26th Brazilian congress on biomedical engineering, vol 70/1. IFMBE. Springer, Singapore, pp 85–88 Cestari IA, Mazzetto M, Oyama HT, Bacht S, Jatene MB, Cestari IN, Jatene FB (2019) Design and hydrodynamic performance of a pediatric pulsatile pump. In: Costa-Felix R, Machado J, Alvarenga A (eds) Proceedings on 26th Brazilian congress on biomedical engineering, vol 70/1. IFMBE. Springer, Singapore, pp 85–88
2.
Zurück zum Zitat Burriesci G, Marincola FC, Zervides C (2010) Design of a novel polymeric heart valve. J Med Eng Technol 34(1):7–22CrossRef Burriesci G, Marincola FC, Zervides C (2010) Design of a novel polymeric heart valve. J Med Eng Technol 34(1):7–22CrossRef
3.
Zurück zum Zitat Rahmani B et al (2012) Manufacturing and hydrodynamic assessment of a novel aortic valve made of a new nanocomposite polymer. J Biomech 45:1205–1211CrossRef Rahmani B et al (2012) Manufacturing and hydrodynamic assessment of a novel aortic valve made of a new nanocomposite polymer. J Biomech 45:1205–1211CrossRef
4.
Zurück zum Zitat Gorlin R, Gorlin SG (1951) Hydraulic formula for calculation of area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. Am Heart J 41:1–29CrossRef Gorlin R, Gorlin SG (1951) Hydraulic formula for calculation of area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. Am Heart J 41:1–29CrossRef
5.
Zurück zum Zitat Claiborne TE et al (2013) In vitro evaluation of a novel hemodynamically optimized trileaflet polymeric prosthetic heart valve. J Biomech Eng 135:021021-1–021021-8 Claiborne TE et al (2013) In vitro evaluation of a novel hemodynamically optimized trileaflet polymeric prosthetic heart valve. J Biomech Eng 135:021021-1–021021-8
6.
Zurück zum Zitat Dasi LP et al (2008) Passive flow control of bileaflet mechanical heart valve leakage flow. J Biomech 41(6):1166–1173CrossRef Dasi LP et al (2008) Passive flow control of bileaflet mechanical heart valve leakage flow. J Biomech 41(6):1166–1173CrossRef
7.
Zurück zum Zitat Yun BM et al (2014) Computational simulations of flow dynamics and blood damage through a bileaflet mechanical heart valve scaled to pediatric size and flow. J Biomech 47(12):3169–3177CrossRef Yun BM et al (2014) Computational simulations of flow dynamics and blood damage through a bileaflet mechanical heart valve scaled to pediatric size and flow. J Biomech 47(12):3169–3177CrossRef
8.
Zurück zum Zitat Lee H et al (2007) Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity. Artif Organs 31:532–537CrossRef Lee H et al (2007) Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity. Artif Organs 31:532–537CrossRef
Metadaten
Titel
Experimental Study of Bileaflet Mechanical Heart Valves
verfasst von
Eraldo Sales
M. Mazzetto
S. Bacht
I. A. Cestari
Copyright-Jahr
2022
DOI
https://doi.org/10.1007/978-3-030-70601-2_11

Neuer Inhalt