Abstract

The existing kW-class air-cooled proton exchange membrane fuel cells (PEMFC) usually control the exhaust valve and fan according to the manufacturer’s recommendations of the purge interval and the optimum temperature, respectively. However, the single-cell voltage and its uniformity under dynamic working conditions are not considered. Nonetheless, single-cell voltage and its uniformity are important factors that reflect and affect the performance and lifetime of the stack. Therefore, it is necessary to investigate the dynamic uniformity of the single-cell voltages under conventional control mode. Based on a self-built 2-kW air-cooled PEMFC test platform, this paper investigated the voltage responses and the single cell dynamic voltage uniformity for PEMFC under dynamic working conditions. For the step loading and unloading conditions, it was observed that the larger the step amplitude, the greater the voltage overshoot or undershoot, the greater the volatility of the single-cell voltage, and the longer the time to restore stability. In particular, large step loading at small currents and large step unloading at high currents can seriously damage single-cell voltages and their uniformity. In addition, large step unloading at high currents has a greater negative impact on the cell voltage than large step loading. For a continuous loading or unloading situation with a constant slope, dynamic variable loading experiments with different frequencies and amplitudes were designed to reach a specified current from different initial currents. It was observed that with an increase in the loading and unloading amplitude and frequency, the uniformity of single-cell voltage becomes worse. However, the effect of ramp loading is greater than that of ramp unloading. Finally, based on these experimental results, dynamic variable loading suggestions involving the voltage uniformity were proposed, which have certain guiding significance and reference value for the practical applications of kW-class air-cooled PEMFC.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Baolian Y, Ming H (2011) Solutions for the durability of fuel cells in vehicle applications. J Automot Saf Energy 2(2):91–100 Baolian Y, Ming H (2011) Solutions for the durability of fuel cells in vehicle applications. J Automot Saf Energy 2(2):91–100
2.
Zurück zum Zitat Jianqiu L, Chuan F, Liangfei X (2014) Current status and trends of the research and development for fuel cell vehicles. J Automot Saf Energy 5(1):17–29 Jianqiu L, Chuan F, Liangfei X (2014) Current status and trends of the research and development for fuel cell vehicles. J Automot Saf Energy 5(1):17–29
3.
Zurück zum Zitat Dai C, Shi Q, Chen W et al (2016) A review of the single cell voltage uniformity in proton exchange membrane fuel cells. Proc CSEE 36(5):1289–1302 Dai C, Shi Q, Chen W et al (2016) A review of the single cell voltage uniformity in proton exchange membrane fuel cells. Proc CSEE 36(5):1289–1302
4.
Zurück zum Zitat Kongjian Q, Dong H, Yongping H et al (2013) Review and prospect of influence factors of vehicular fuel cell performance degradation. Chin J Automot Eng 3(4):242–250 Kongjian Q, Dong H, Yongping H et al (2013) Review and prospect of influence factors of vehicular fuel cell performance degradation. Chin J Automot Eng 3(4):242–250
5.
Zurück zum Zitat You Zhiyu X, Tao LZ et al (2014) Study on air-cooled self-humidifying PEMFC control method based on segmented predict negative feedback control. Electrochim Acta 132:389–396CrossRef You Zhiyu X, Tao LZ et al (2014) Study on air-cooled self-humidifying PEMFC control method based on segmented predict negative feedback control. Electrochim Acta 132:389–396CrossRef
6.
Zurück zum Zitat Xingguang ZHU, Qiuhong JIA, Tanglong CHEN et al (2013) Experimental study on characteristics of cathode fan systems of proton exchange membrane fuel cells. Proc CSEE 33(11):47–53 Xingguang ZHU, Qiuhong JIA, Tanglong CHEN et al (2013) Experimental study on characteristics of cathode fan systems of proton exchange membrane fuel cells. Proc CSEE 33(11):47–53
7.
Zurück zum Zitat Dong W, Dong Z, Enhui Z (2010) Temperature-humidity characteristics modeling and output control based on adaptive Fuzzy method for proton exchange membrane fuel cell stack. Proc CSEE 30(23):114–120 Dong W, Dong Z, Enhui Z (2010) Temperature-humidity characteristics modeling and output control based on adaptive Fuzzy method for proton exchange membrane fuel cell stack. Proc CSEE 30(23):114–120
9.
Zurück zum Zitat Saygılı Y, Kıncal S, Eroglu I (2015) Development and modeling for process control purposes in PEMs. Int J Hydrog Energy 40(24):7886–7894CrossRef Saygılı Y, Kıncal S, Eroglu I (2015) Development and modeling for process control purposes in PEMs. Int J Hydrog Energy 40(24):7886–7894CrossRef
10.
Zurück zum Zitat Philipps F, Simons G, Schiefer K (2006) Dynamic investigation of PEFC stacks in interaction with the air supply system. J Power Sources 154(2):412–419CrossRef Philipps F, Simons G, Schiefer K (2006) Dynamic investigation of PEFC stacks in interaction with the air supply system. J Power Sources 154(2):412–419CrossRef
11.
Zurück zum Zitat Li J, Zunyan H, Liangfei X et al (2016) Fuel cell system degradation analysis of a Chinese plug-in hybrid fuel cell city bus. Int J Hydrog Energy 41(34):15295–15310CrossRef Li J, Zunyan H, Liangfei X et al (2016) Fuel cell system degradation analysis of a Chinese plug-in hybrid fuel cell city bus. Int J Hydrog Energy 41(34):15295–15310CrossRef
12.
Zurück zum Zitat Zhu H, Payne RU, Cahela DR (2004) Uniformity analysis at MEA and stack levels for a Nexa PEM fuel cell system. J Power Sources 128(2):231–238CrossRef Zhu H, Payne RU, Cahela DR (2004) Uniformity analysis at MEA and stack levels for a Nexa PEM fuel cell system. J Power Sources 128(2):231–238CrossRef
13.
Zurück zum Zitat Giddey S, Ciacchi FT, Badwal SPS (2004) Design, assembly and operation of polymer electrolyte membrane fuel cell stacks to 1 kWe capacity. J Power Sources 125:155–165CrossRef Giddey S, Ciacchi FT, Badwal SPS (2004) Design, assembly and operation of polymer electrolyte membrane fuel cell stacks to 1 kWe capacity. J Power Sources 125:155–165CrossRef
14.
Zurück zum Zitat Yankun L, Xingqiang Z, Zhixiang L, Yan L, Weirong C, Qi L (2015) Experimental study on the voltage uniformity for dynamic loading of a PEM fuel cell stack. Int J Hydrog Energy 40(23):7361–7369CrossRef Yankun L, Xingqiang Z, Zhixiang L, Yan L, Weirong C, Qi L (2015) Experimental study on the voltage uniformity for dynamic loading of a PEM fuel cell stack. Int J Hydrog Energy 40(23):7361–7369CrossRef
15.
Zurück zum Zitat Ous T, Arcoumanis C (2013) Degradation aspects of water formation and transport in proton exchange membrane fuel cell: a review. J Power Sources 240:558–582CrossRef Ous T, Arcoumanis C (2013) Degradation aspects of water formation and transport in proton exchange membrane fuel cell: a review. J Power Sources 240:558–582CrossRef
16.
Zurück zum Zitat Feijie W, Daijun Y, Hao Z et al (2013) Response features of a 1.5 kW proton exchange membrane fuel cell stack for dynamic cycle. CIESC J 64(4):1380–1386 Feijie W, Daijun Y, Hao Z et al (2013) Response features of a 1.5 kW proton exchange membrane fuel cell stack for dynamic cycle. CIESC J 64(4):1380–1386
17.
Zurück zum Zitat Verma A, Pitchumani R (2014) Effects of operating parameters on the transient response of proton exchange membrane fuel cells subject to load changes. Int J Hydrog Energy 39(33):19024–19038CrossRef Verma A, Pitchumani R (2014) Effects of operating parameters on the transient response of proton exchange membrane fuel cells subject to load changes. Int J Hydrog Energy 39(33):19024–19038CrossRef
Metadaten
Titel
Experimental study on dynamic voltage uniformity of a 2-kW air-cooled PEMFC
verfasst von
Ming Li
Chaohua Dai
Ai Guo
Weirong Chen
Publikationsdatum
21.09.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Electrical Engineering / Ausgabe 4/2018
Print ISSN: 0948-7921
Elektronische ISSN: 1432-0487
DOI
https://doi.org/10.1007/s00202-018-0733-5

Weitere Artikel der Ausgabe 4/2018

Electrical Engineering 4/2018 Zur Ausgabe

Neuer Inhalt