Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 12/2008

01.12.2008 | Technical Note

Finger and ear photoplethysmogram waveform analysis by fitting with Gaussians

verfasst von: Uldis Rubins

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 12/2008

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Analysis of the contour of the blood volume pulse (VP) has become important because it contains much information about cardiovascular activity. Traditionally, pulse contour analysis requires first or higher derivatives to be calculated. This paper describes a novel algorithm for analysing simultaneously measured ear and finger photoplethysmography (PPG) signals. The algorithm separates the systolic wave and the diastolic wave of the VP and fits each of them with the sum of two Gaussian functions. The VP was obtained from PPG signals taken from 40 healthy subjects at each heartbeat cycle. From the evaluated VP, time values of the direct wave and three reflected waves were calculated, as well as the augmentation index (AI) and the reflection index (RI). The evaluated parameters were compared with those that were obtained by the derivative method, and it was demonstrated that the new method can be used to analyze VP waveforms.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Bortolotto LA, Blacher J, Kondo T, Takazawa K, Safar ME (2000) Assessment of vascular aging and atherosclerosis in hypertensive subjects: second derivative of photoplethysmogram versus pulse wave velocity. Am J Hypertens 13:165–171. doi:10.1016/S0895-7061(99)00192-2 CrossRef Bortolotto LA, Blacher J, Kondo T, Takazawa K, Safar ME (2000) Assessment of vascular aging and atherosclerosis in hypertensive subjects: second derivative of photoplethysmogram versus pulse wave velocity. Am J Hypertens 13:165–171. doi:10.​1016/​S0895-7061(99)00192-2 CrossRef
3.
Zurück zum Zitat Foo JY, Wilson SJ (2006) A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states. Med Biol Eng Comput 44(1–2):140–145. doi:10.1007/s11517-005-0008-y CrossRef Foo JY, Wilson SJ (2006) A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states. Med Biol Eng Comput 44(1–2):140–145. doi:10.​1007/​s11517-005-0008-y CrossRef
4.
Zurück zum Zitat Imanaga I, Hara H, Koyanagi S, Tanaka K (1998) Correlation between wave components of the second derivative of the plethysmogram and arterial distensibility. Jpn Heart J 39:775–784 Imanaga I, Hara H, Koyanagi S, Tanaka K (1998) Correlation between wave components of the second derivative of the plethysmogram and arterial distensibility. Jpn Heart J 39:775–784
7.
Zurück zum Zitat Millaseau SC, Kelly RP, Ritter JM, Chowienczyk PJ (2002) Determination of age-related increases in large artery stiffness by digital pulse contour analysis. Clin Sci 103:371–377 Millaseau SC, Kelly RP, Ritter JM, Chowienczyk PJ (2002) Determination of age-related increases in large artery stiffness by digital pulse contour analysis. Clin Sci 103:371–377
9.
Zurück zum Zitat Takazawa K, Tanaka N, Fujita M, Matsuoka O, Saiki T, Aikawa M et al (1998) Assessment of vascoactive agents and vascular aging by the second derivative of photoplethysmogram waveform. Hypertension 32:365–370 Takazawa K, Tanaka N, Fujita M, Matsuoka O, Saiki T, Aikawa M et al (1998) Assessment of vascoactive agents and vascular aging by the second derivative of photoplethysmogram waveform. Hypertension 32:365–370
10.
11.
Zurück zum Zitat Westerhof N, Stergiopulos N, Noble MNM (2005) Snapshots of hemodynamics. Springer 15:69–70 Westerhof N, Stergiopulos N, Noble MNM (2005) Snapshots of hemodynamics. Springer 15:69–70
Metadaten
Titel
Finger and ear photoplethysmogram waveform analysis by fitting with Gaussians
verfasst von
Uldis Rubins
Publikationsdatum
01.12.2008
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 12/2008
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-008-0406-z

Weitere Artikel der Ausgabe 12/2008

Medical & Biological Engineering & Computing 12/2008 Zur Ausgabe