Skip to main content
Erschienen in: Tribology Letters 3/2010

01.12.2010 | Original Paper

Fretting Wear Study on Micro-Arc Oxidation TiO2 Coating on TC4 Titanium Alloys in Simulated Body Fluid

verfasst von: Guanghong Zhou, Hongyan Ding, Yue Zhang, Aihui Liu, Yuebin Lin, Yufu Zhu

Erschienen in: Tribology Letters | Ausgabe 3/2010

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Tribological properties of TiO2 coatings synthesized by micro-arc oxidation (MAO) on the surface of TC4 titanium alloys were investigated at the fretting contact against 440C stainless steel in simulated body fluid (SBF). Fretting experiments were carried out by ball-on-flat contact at various loads for 1 h, with an amplitude of 100 μm and a frequency of 5 Hz. Results show that MAO TiO2 coatings presented good tribological properties with lower friction coefficient in SBF. Less wear volume was observed for MAO TiO2 coatings compared with that for TC4 alloy. At lower load, the wear mechanism of MAO TiO2 coatings was dominated to abrasive wear. With an increase of normal load, however, fretting corrosion increased due to chemical reactions with SBF, and therefore, fretting fatigue coexisting with abrasive wear became the predominant mode.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Iwabuchi, A., Lee, J.W., Uchidate, M.: Synergistic effect of fretting wear and sliding wear of Co-alloy and Ti-alloy in Hanks’ solution. Wear 263, 492–500 (2007)CrossRef Iwabuchi, A., Lee, J.W., Uchidate, M.: Synergistic effect of fretting wear and sliding wear of Co-alloy and Ti-alloy in Hanks’ solution. Wear 263, 492–500 (2007)CrossRef
2.
Zurück zum Zitat Matsuno, H., Yokoyama, A., Watari, F., Uo, M., Kawasaki, T.: Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. Biomaterials 22, 1253–1262 (2001)CrossRefPubMed Matsuno, H., Yokoyama, A., Watari, F., Uo, M., Kawasaki, T.: Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. Biomaterials 22, 1253–1262 (2001)CrossRefPubMed
3.
Zurück zum Zitat Khan, M.A., Williams, R.L., Williams, D.F.: Conjoint corrosion and wear in titanium alloys. Biomaterials 20, 765–772 (1999)CrossRefPubMed Khan, M.A., Williams, R.L., Williams, D.F.: Conjoint corrosion and wear in titanium alloys. Biomaterials 20, 765–772 (1999)CrossRefPubMed
4.
Zurück zum Zitat Willert, H.G., Semlitsch, M.: Reactions of the articular capsule to wear products of artificial joint prostheses. J. Biomed. Mater. Res. 11, 157–164 (1977)CrossRefPubMed Willert, H.G., Semlitsch, M.: Reactions of the articular capsule to wear products of artificial joint prostheses. J. Biomed. Mater. Res. 11, 157–164 (1977)CrossRefPubMed
5.
Zurück zum Zitat Brown, S.A., Merritt, K.: Fretting corrosion in saline and serum. J. Biomed. Mater. Res. 15, 479–488 (1981)CrossRefPubMed Brown, S.A., Merritt, K.: Fretting corrosion in saline and serum. J. Biomed. Mater. Res. 15, 479–488 (1981)CrossRefPubMed
6.
Zurück zum Zitat Langkamer, V.G., Case, C.P., Watt, I., Palmer, M., Atkins, R.M.: Aggressive wear-debris pseudotumor following total hip replacement. Orthopedics 22, 353–355 (1999)PubMed Langkamer, V.G., Case, C.P., Watt, I., Palmer, M., Atkins, R.M.: Aggressive wear-debris pseudotumor following total hip replacement. Orthopedics 22, 353–355 (1999)PubMed
7.
Zurück zum Zitat Uo, M., Watari, F., Yokoyama, A., Matsuno, H., Kawasaki, T.: Visualization and detectability of elements rarely contained in soft tissue by X-ray scanning analytical microscopy and electron-probe micro analysis. Biomaterials 22, 1787–1794 (2001)CrossRefPubMed Uo, M., Watari, F., Yokoyama, A., Matsuno, H., Kawasaki, T.: Visualization and detectability of elements rarely contained in soft tissue by X-ray scanning analytical microscopy and electron-probe micro analysis. Biomaterials 22, 1787–1794 (2001)CrossRefPubMed
8.
Zurück zum Zitat Liu, X.Y., Chu, P.K., Ding, C.X.: Surface modification of titanium, titanium alloys, and related materials for biomedical applications. Mat. Sci. Eng. R 47, 49–121 (2004)CrossRefADS Liu, X.Y., Chu, P.K., Ding, C.X.: Surface modification of titanium, titanium alloys, and related materials for biomedical applications. Mat. Sci. Eng. R 47, 49–121 (2004)CrossRefADS
9.
Zurück zum Zitat Choubey, A., Basu, B., Balasubramaniam, R.: Tribological behaviour of Ti-based alloys in simulated body fluid solution at fretting contacts. Mat. Sci. Eng. A 379, 234–239 (2004)CrossRef Choubey, A., Basu, B., Balasubramaniam, R.: Tribological behaviour of Ti-based alloys in simulated body fluid solution at fretting contacts. Mat. Sci. Eng. A 379, 234–239 (2004)CrossRef
10.
Zurück zum Zitat Bailey, L.O., Lipplatt, S., Biancanello, F.S., Ridder, S.D., Washburn, N.R.: The quantification of cellular viability and inflammatory response to stainless steel alloys. Biomaterials 26, 5296–5302 (2005)CrossRefPubMed Bailey, L.O., Lipplatt, S., Biancanello, F.S., Ridder, S.D., Washburn, N.R.: The quantification of cellular viability and inflammatory response to stainless steel alloys. Biomaterials 26, 5296–5302 (2005)CrossRefPubMed
11.
Zurück zum Zitat Merritt, K., Brown, S.A.: Metal sensitivity reactions to orthopedic implants. Int. J. Dermatol. 20, 89–94 (1981)CrossRefPubMed Merritt, K., Brown, S.A.: Metal sensitivity reactions to orthopedic implants. Int. J. Dermatol. 20, 89–94 (1981)CrossRefPubMed
12.
Zurück zum Zitat Schuh, A., Thomas, P., Kachler, W., Goske, J., Wagner, L., Holzwarth, U., Forst, R.: Allergic potential of titanium implants. Orthopade 34, 327–333 (2005)CrossRefPubMed Schuh, A., Thomas, P., Kachler, W., Goske, J., Wagner, L., Holzwarth, U., Forst, R.: Allergic potential of titanium implants. Orthopade 34, 327–333 (2005)CrossRefPubMed
13.
Zurück zum Zitat Ning, C.Q., Zhou, Y.: In vitro bioactivity of a biocomposite fabricated from HA and Ti powders by powder metallurgy method. Biomaterials 23, 2909–2915 (2002)CrossRefPubMed Ning, C.Q., Zhou, Y.: In vitro bioactivity of a biocomposite fabricated from HA and Ti powders by powder metallurgy method. Biomaterials 23, 2909–2915 (2002)CrossRefPubMed
14.
Zurück zum Zitat Karanjai, M., Kumar, B.V.M., Sundaresan, R., Basu, B., Mohan, T.R.R., Kashyap, B.P.: Fretting wear study on Ti-Ca-P biocomposite in dry and simulated body fluid. Mat. Sci. Eng. A 475, 299–307 (2008)CrossRef Karanjai, M., Kumar, B.V.M., Sundaresan, R., Basu, B., Mohan, T.R.R., Kashyap, B.P.: Fretting wear study on Ti-Ca-P biocomposite in dry and simulated body fluid. Mat. Sci. Eng. A 475, 299–307 (2008)CrossRef
15.
Zurück zum Zitat Navaneethakrishnan, P., Raman, S.G.S., Pathak, S.D., Gnanamoorthy, R., Ravi, N.: Fretting wear studies on diamond-like carbon coated Ti-6Al-4 V. Surf. Coat. Technol. 203, 1205–1212 (2009)CrossRef Navaneethakrishnan, P., Raman, S.G.S., Pathak, S.D., Gnanamoorthy, R., Ravi, N.: Fretting wear studies on diamond-like carbon coated Ti-6Al-4 V. Surf. Coat. Technol. 203, 1205–1212 (2009)CrossRef
16.
Zurück zum Zitat Budzynski, P., Youssef, A.A., Sielanko, J.: Surface modification of Ti-6Al-4V alloy by nitrogen ion implantation. Wear 261, 1271–1276 (2006)CrossRef Budzynski, P., Youssef, A.A., Sielanko, J.: Surface modification of Ti-6Al-4V alloy by nitrogen ion implantation. Wear 261, 1271–1276 (2006)CrossRef
17.
Zurück zum Zitat Dong, Q., Chen, C.Z., Wang, D.G., Ji, Q.M.: Research status about surface modification of biomedical Ti and its alloys by micro-arc oxidation. Surf. Rev. Lett. 13, 35–43 (2006)CrossRef Dong, Q., Chen, C.Z., Wang, D.G., Ji, Q.M.: Research status about surface modification of biomedical Ti and its alloys by micro-arc oxidation. Surf. Rev. Lett. 13, 35–43 (2006)CrossRef
18.
Zurück zum Zitat Lee, Y.K.: Effects of electrical parameters on titania film grown by micro-arc oxidation. Mod. Phys. Lett. B 23, 2035–2040 (2009)CrossRefADS Lee, Y.K.: Effects of electrical parameters on titania film grown by micro-arc oxidation. Mod. Phys. Lett. B 23, 2035–2040 (2009)CrossRefADS
19.
Zurück zum Zitat Santos, A., Lidizio, L.R., Cruz, T.S., Sena, L.A., Damasceno, C.J., Achete, A.C.: Influence of electrolyte composition and time deposition on TiO2 films produced by micro-arc oxidation. Key Eng. Mater. 396–398, 349–352 (2009)CrossRef Santos, A., Lidizio, L.R., Cruz, T.S., Sena, L.A., Damasceno, C.J., Achete, A.C.: Influence of electrolyte composition and time deposition on TiO2 films produced by micro-arc oxidation. Key Eng. Mater. 396–398, 349–352 (2009)CrossRef
20.
Zurück zum Zitat Jiang, Z.H., Sun, X.T., Li, Y.P., Wang, F.P., Lu, Y.D.: Effect of the oxidation time on properties of ceramic coatings produced on Ti-6Al-4V by micro-arc oxidation. J. Mater. Sci. Technol. 21, 281–284 (2005)CrossRef Jiang, Z.H., Sun, X.T., Li, Y.P., Wang, F.P., Lu, Y.D.: Effect of the oxidation time on properties of ceramic coatings produced on Ti-6Al-4V by micro-arc oxidation. J. Mater. Sci. Technol. 21, 281–284 (2005)CrossRef
21.
Zurück zum Zitat Li, Y., Lee, I.S., Cui, F.Z., Choi, S.H.: The biocompatibility of nanostructured calcium phosphate coated on micro-arc oxidized titanium. Biomaterials 29, 2025–2032 (2008)CrossRefPubMed Li, Y., Lee, I.S., Cui, F.Z., Choi, S.H.: The biocompatibility of nanostructured calcium phosphate coated on micro-arc oxidized titanium. Biomaterials 29, 2025–2032 (2008)CrossRefPubMed
22.
Zurück zum Zitat Yu, S.R., Yang, X.Z., Yang, L., Liu, Y.H., Yu, Y.J.: Novel technique for preparing Ca- and P-containing ceramic coating on Ti-6Al-4V by micro-arc oxidation. J. Biomed. Mater. Res. B Appl. Biomater. 83B, 623–627 (2007)CrossRef Yu, S.R., Yang, X.Z., Yang, L., Liu, Y.H., Yu, Y.J.: Novel technique for preparing Ca- and P-containing ceramic coating on Ti-6Al-4V by micro-arc oxidation. J. Biomed. Mater. Res. B Appl. Biomater. 83B, 623–627 (2007)CrossRef
23.
Zurück zum Zitat Wang, Y.M., Zhang, P.F., Guo, L.X., Ouyang, J.H., Zhou, Y., Jia, D.C.: Effect of microarc oxidation coating on fatigue performance of Ti-Al-Zr alloy. Appl. Surf. Sci. 255, 8616–8623 (2009)CrossRefADS Wang, Y.M., Zhang, P.F., Guo, L.X., Ouyang, J.H., Zhou, Y., Jia, D.C.: Effect of microarc oxidation coating on fatigue performance of Ti-Al-Zr alloy. Appl. Surf. Sci. 255, 8616–8623 (2009)CrossRefADS
24.
Zurück zum Zitat Sun, X.T., Jiang, Z.H., Xin, S.G., Yao, Z.P.: Composition and mechanical properties of hard ceramic coating containing alpha-Al2O3 produced by microarc oxidation on Ti-6Al-4V alloy. Thin Solid Films 471, 194–199 (2005)CrossRefADS Sun, X.T., Jiang, Z.H., Xin, S.G., Yao, Z.P.: Composition and mechanical properties of hard ceramic coating containing alpha-Al2O3 produced by microarc oxidation on Ti-6Al-4V alloy. Thin Solid Films 471, 194–199 (2005)CrossRefADS
25.
Zurück zum Zitat Guo, B.G., Liang, J., Tian, J., Liu, H.W., Xu, T.: Structure and composition of surface and interface of micro-arc oxide ceramic layer on Ti-6Al-4V alloy. Rare Metal Mater. Eng. 34, 1897–1900 (2005) Guo, B.G., Liang, J., Tian, J., Liu, H.W., Xu, T.: Structure and composition of surface and interface of micro-arc oxide ceramic layer on Ti-6Al-4V alloy. Rare Metal Mater. Eng. 34, 1897–1900 (2005)
26.
Zurück zum Zitat Wei, Z.S., Wang, M., Zhang, M., Ding, W.J.: Study on fretting fatigue behavior of TC4 titanium alloy. Rare Metal Mater. Eng. 35, 1050–1052 (2006) Wei, Z.S., Wang, M., Zhang, M., Ding, W.J.: Study on fretting fatigue behavior of TC4 titanium alloy. Rare Metal Mater. Eng. 35, 1050–1052 (2006)
27.
Zurück zum Zitat Merhej, R., Fouvry, S.: Contact size effect on fretting wear behavior: application to an AISI 52100/AISI 52100 interface. Lubr. Sci. 21, 83–102 (2009)CrossRef Merhej, R., Fouvry, S.: Contact size effect on fretting wear behavior: application to an AISI 52100/AISI 52100 interface. Lubr. Sci. 21, 83–102 (2009)CrossRef
28.
Zurück zum Zitat Johnson, L.: Contact Mechanics, pp. 50–55. Cambridge University Press, Cambridge (1989) Johnson, L.: Contact Mechanics, pp. 50–55. Cambridge University Press, Cambridge (1989)
29.
Zurück zum Zitat Zhou, G.H., Zhang, Y., Ding, H.Y.: Negative synergism between corrosion and wear of Nickel-free austenitic stainless steel in artificial body solution. Mater. Sci. Forum 610–613, 1183–1187 (2009)CrossRef Zhou, G.H., Zhang, Y., Ding, H.Y.: Negative synergism between corrosion and wear of Nickel-free austenitic stainless steel in artificial body solution. Mater. Sci. Forum 610–613, 1183–1187 (2009)CrossRef
Metadaten
Titel
Fretting Wear Study on Micro-Arc Oxidation TiO2 Coating on TC4 Titanium Alloys in Simulated Body Fluid
verfasst von
Guanghong Zhou
Hongyan Ding
Yue Zhang
Aihui Liu
Yuebin Lin
Yufu Zhu
Publikationsdatum
01.12.2010
Verlag
Springer US
Erschienen in
Tribology Letters / Ausgabe 3/2010
Print ISSN: 1023-8883
Elektronische ISSN: 1573-2711
DOI
https://doi.org/10.1007/s11249-010-9665-6

Weitere Artikel der Ausgabe 3/2010

Tribology Letters 3/2010 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.