Skip to main content
Erschienen in: Sustainable Water Resources Management 5/2023

01.10.2023 | Original Article

Geophysical and hydrochemical assessment of the risk posed by open dumpsite at Kaduna Central Market, Nigeria

verfasst von: Joseph Omeiza Alao, Abubakar Fahad, Eli Danladi, Theophilus Toro Danjuma, Ekwu Tongha Mary, Abdullahi Diya’ulhaq

Erschienen in: Sustainable Water Resources Management | Ausgabe 5/2023

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Open dumping is becoming a fast-spreading bad phenomenon across the globe. The groundwater systems and ambient soil remain the major hotspots of the dumpsite leachate plumes activities. An electrical resistivity survey and hydrochemical investigations were undertaken within and off-dumpsite to assess the environmental impacts of the dumpsite leachates. Schlumberger method was used to acquire twenty-nine (29) vertical electrical sounding (VES) points across two orthogonal traverses established within and off-dumpsite to investigate the level of impacts of the dumpsite leachate plumes on the soil and groundwater resources. While the protective overburden soil layers resistivity values vary between 2.4 and 217 Ωm within the dumpsite, the off-site varies between 117 and 1313 Ωm. The study indicates that the overburdened soil layers overlying the weathered/fractured unit, which constitute the aquifer systems of the region, were suspected to have been compromised by dumpsite leachate plumes as indicated by the low resistivity values characterizing the subsoil layers. The hydrochemical analysis of water samples from the investigated six hand-dug wells (HDWs) shows the presence of heavy metals (HMs). The results of the laboratory analysis of the water sample indicate a high content of electrical conductivity (0.699–1.221 mg/l), iron (0.782–1.9181 mg/l), lead (0.871–1.992 mg/l), chromium (0.333–0.512 mg/l), and cadmium (0.0211–0.0419 mg/l), while the high contents of chemical oxygen demand (COD) (459–561 mg/l), biological oxygen demand (BOD) (902–1017 mg/l), and total dissolved solids (TDS) (597–1301 mg/l). The high content of BOD and COD in the dumpsite leachate plumes shows high organic potency. However, it was noted that the concentration decreased as the pollutant source distance increased, while the shallow depth seems to have been more impacted. Geophysical and hydrochemical data show that the degree of the impacts of the dumpsite leachate plumes seeping the ground down the water table is a function of depth, source distance and subsurface properties. Both techniques confirmed the infiltration of leachate plumes into the soil and groundwater systems posing a great risk to public health. Therefore, to obtain clean and portable drinking water, it is suggested that HDWs/boreholes should be sited at least 100 m away from the dumpsite to at least a depth of 15 m.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Abdullahi NK, Osazuwa IB, Sule PO, Onugba A (2013) Geophysical assessment of an active open dumpsite in basement complex of North-western Nigeria. Int J Eng Sci Invention ISSN (online). 2(5):12–21 (2319–6734, ISSN (Print): 2319–6726) Abdullahi NK, Osazuwa IB, Sule PO, Onugba A (2013) Geophysical assessment of an active open dumpsite in basement complex of North-western Nigeria. Int J Eng Sci Invention ISSN (online). 2(5):12–21 (2319–6734, ISSN (Print): 2319–6726)
Zurück zum Zitat Aboh HO, Dogara MD, Alao JO (2016) Evaluation of the geotechnical parameters in part of Kaduna, Kaduna State Nigeria. World J Appl Sci Technol 8(2):108–117. ISSN: 2141–3290; www.wojast.com Aboh HO, Dogara MD, Alao JO (2016) Evaluation of the geotechnical parameters in part of Kaduna, Kaduna State Nigeria. World J Appl Sci Technol 8(2):108–117. ISSN: 2141–3290; www.​wojast.​com
Zurück zum Zitat Ercolano S, Gaeta G, Ghinoi S, Silvestri F (2018) Kuznets curve in municipal solid waste production: An empirical analysis based on municipal-level panel data from the Lombardy region (Italy). Ecol Indic 93:397–403CrossRef Ercolano S, Gaeta G, Ghinoi S, Silvestri F (2018) Kuznets curve in municipal solid waste production: An empirical analysis based on municipal-level panel data from the Lombardy region (Italy). Ecol Indic 93:397–403CrossRef
Zurück zum Zitat Isaac OO, Jonah CA, Joel AO (2010) Assessment of aquifer characteristics in relation to rural water supply in Part of Northern Nigeria. Researcher 2(3):22–27 Isaac OO, Jonah CA, Joel AO (2010) Assessment of aquifer characteristics in relation to rural water supply in Part of Northern Nigeria. Researcher 2(3):22–27
Zurück zum Zitat Olayinka AI (1992) Geophysical siting of boreholes in crystalline basement Areas of Africa. J Africa Earth Sci (middle East) 14:197–207CrossRef Olayinka AI (1992) Geophysical siting of boreholes in crystalline basement Areas of Africa. J Africa Earth Sci (middle East) 14:197–207CrossRef
Zurück zum Zitat Omotayo AI, Adefila SA, Mustapha TA (2019) Impact of Olusosun landfill leachate on the growth and germination of Celosia Argentea. J Waste Manag Disposal 2:107 Omotayo AI, Adefila SA, Mustapha TA (2019) Impact of Olusosun landfill leachate on the growth and germination of Celosia Argentea. J Waste Manag Disposal 2:107
Zurück zum Zitat Oyawoye MO (1970) The basement complex of Nigeria. In: Dessauvagie TFJ, Whiteman AJ (eds) African geology. University Press, Ibadan Oyawoye MO (1970) The basement complex of Nigeria. In: Dessauvagie TFJ, Whiteman AJ (eds) African geology. University Press, Ibadan
Zurück zum Zitat Roychoudhury A, Chakraborty S (2021) Effect of hydrogen sulfide on osmotic adjustment of plants under different abiotic stresses. In: Khan MN, Siddiqui MH, Alamri S, Corpas FJ (eds) Hydrogen sulfide and plant acclimation to abiotic stresse. Plant in challenging environments, vol 1. Springer, Cham. https://doi.org/10.1007/978-3-030-73678-1_5CrossRef Roychoudhury A, Chakraborty S (2021) Effect of hydrogen sulfide on osmotic adjustment of plants under different abiotic stresses. In: Khan MN, Siddiqui MH, Alamri S, Corpas FJ (eds) Hydrogen sulfide and plant acclimation to abiotic stresse. Plant in challenging environments, vol 1. Springer, Cham. https://​doi.​org/​10.​1007/​978-3-030-73678-1_​5CrossRef
Zurück zum Zitat Telford WM, Geldart LP, Sheriff ER (1990) Applied geophysics. Cambridge University Press, CambridgeCrossRef Telford WM, Geldart LP, Sheriff ER (1990) Applied geophysics. Cambridge University Press, CambridgeCrossRef
Metadaten
Titel
Geophysical and hydrochemical assessment of the risk posed by open dumpsite at Kaduna Central Market, Nigeria
verfasst von
Joseph Omeiza Alao
Abubakar Fahad
Eli Danladi
Theophilus Toro Danjuma
Ekwu Tongha Mary
Abdullahi Diya’ulhaq
Publikationsdatum
01.10.2023
Verlag
Springer International Publishing
Erschienen in
Sustainable Water Resources Management / Ausgabe 5/2023
Print ISSN: 2363-5037
Elektronische ISSN: 2363-5045
DOI
https://doi.org/10.1007/s40899-023-00948-6

Weitere Artikel der Ausgabe 5/2023

Sustainable Water Resources Management 5/2023 Zur Ausgabe