Skip to main content
Erschienen in: Experiments in Fluids 4-5/2009

01.10.2009 | Research Article

Global Doppler frequency shift detection with near-resonant interferometry

verfasst von: Andrin Landolt, Thomas Roesgen

Erschienen in: Experiments in Fluids | Ausgabe 4-5/2009

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The recent development in measuring 2D Doppler shift distributions for flow velocimetry using the dispersive properties of atomic line filters is presented. On the basis of velocity field measurements on a subsonic jet flow and a tip vortex flow in a medium-sized wind tunnel, the technique was assessed. Atomic line filters near a resonant transition combine imaging capabilities with a sharp frequency cutoff and an associated region of strong anomalous dispersion. While conventional Doppler global velocimetry relies on the absorption of the filter to convert frequency shifts to intensity variations, near-resonant interferometry uses its dispersion to detect frequency shifts as phase changes in an interference pattern. In the present setup, an iodine vapor cell in an imaging Michelson interferometer is used. With the illuminating laser frequency tuned near a resonant transition, the cell’s dispersion converts the frequency content of the field of view into a distortion of the carrier-fringe pattern recorded at the image plane of the interferometer. The phase distribution in the fringe images is reconstructed by filtering the individual images with a 2D Gabor filter pair tuned to the spatial frequencies of the basic carrier-fringe pattern. The post-processing is concluded with subsequent phase-unwrapping and subtraction of the carrier reference fringe phase. The method and the setup were demonstrated and calibrated experimentally on a rotating disc. The capability of the technique to operate in a real experimental environment was validated in a free subsonic jet and a tip vortex flow behind a wing section in a medium-sized wind tunnel facility. The measurements were found to be in generally good agreement with the theoretically predicted system characteristics and the reference measurements. As with other Doppler global techniques, the stability of the pulsed laser system and the secondary scattering in the test volume were identified as the main error sources.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Fischer A, Büttner L, Czarske J, Eggert M, Grosche G, Müller H (2007) Investigation of time-resolved single-detector Doppler global velocimetry using sinusoidal laser frequency modulation. Meas Sci Technol 18:2529–2545CrossRef Fischer A, Büttner L, Czarske J, Eggert M, Grosche G, Müller H (2007) Investigation of time-resolved single-detector Doppler global velocimetry using sinusoidal laser frequency modulation. Meas Sci Technol 18:2529–2545CrossRef
Zurück zum Zitat Ford HD, Nobes DS, Tatam RP (2001) Acousto-optic frequency switching for single-camera planar Doppler velocimetry. Proc Soc Photo Opt Instrum Eng 4448:272–282 Ford HD, Nobes DS, Tatam RP (2001) Acousto-optic frequency switching for single-camera planar Doppler velocimetry. Proc Soc Photo Opt Instrum Eng 4448:272–282
Zurück zum Zitat Forkey JN, Lempert WR, Miles RB (1997) Corrected and calibrated I2 absorption model at frequency-doubled Nd:YAG laser wavelengths. Appl Opt 36(27):6729–6738CrossRef Forkey JN, Lempert WR, Miles RB (1997) Corrected and calibrated I2 absorption model at frequency-doubled Nd:YAG laser wavelengths. Appl Opt 36(27):6729–6738CrossRef
Zurück zum Zitat Gerstenkorn S, Luc P (1978) Atlas du spectre d’Absorption de la Molecule d’Iode, 14,800–20,000 cm−1. Laboratoire Aimé-Cotton CNRS II, Orsay Gerstenkorn S, Luc P (1978) Atlas du spectre d’Absorption de la Molecule d’Iode, 14,800–20,000 cm−1. Laboratoire Aimé-Cotton CNRS II, Orsay
Zurück zum Zitat Ghiglia DC, Romero LA (1994) Robust two-dimensional weighted and unweighted phase unwrapping that uses fast transforms and iterative methods. J Opt Soc Am A 11(1):107–117CrossRef Ghiglia DC, Romero LA (1994) Robust two-dimensional weighted and unweighted phase unwrapping that uses fast transforms and iterative methods. J Opt Soc Am A 11(1):107–117CrossRef
Zurück zum Zitat Jähne B (2005) Digital image processing. 6 th rev. and extended edn. Springer, Heidelberg Jähne B (2005) Digital image processing. 6 th rev. and extended edn. Springer, Heidelberg
Zurück zum Zitat Komine H, Brosnan SJ, Litton AB, Stappaerts EA (1991) Real-time Doppler global velocimetry. In: AIAA 29th Aerospace Sciences Meeting, Reno, Nevada, paper 91-0337 Komine H, Brosnan SJ, Litton AB, Stappaerts EA (1991) Real-time Doppler global velocimetry. In: AIAA 29th Aerospace Sciences Meeting, Reno, Nevada, paper 91-0337
Zurück zum Zitat Landolt A, Roesgen T (2006) Global Doppler frequency shift detection with near-resonant interferometry. In: 13 th Int Symp. on applications of laser techniques to fluid mechanics, Lisbon, Portugal, p 21.7 Landolt A, Roesgen T (2006) Global Doppler frequency shift detection with near-resonant interferometry. In: 13 th Int Symp. on applications of laser techniques to fluid mechanics, Lisbon, Portugal, p 21.7
Zurück zum Zitat Lu Z-H, Charrett TOH, Ford HD, Tatam RP (2007) Mach–Zehnder interferometric filter based planar Doppler velocimetry (MZI-PDV). J Opt A Pure Appl Opt 9(11):1002–1013CrossRef Lu Z-H, Charrett TOH, Ford HD, Tatam RP (2007) Mach–Zehnder interferometric filter based planar Doppler velocimetry (MZI-PDV). J Opt A Pure Appl Opt 9(11):1002–1013CrossRef
Zurück zum Zitat Meier AH, Roesgen T (2009) Heterodyne Doppler global velocimetry. In: 14th international symposium on applications of laser techniques to fluid mechanics, Lisbon, Portugal, p 7.3.4. Exp Fluids. doi:10.1007/s00348-009-0647-0 Meier AH, Roesgen T (2009) Heterodyne Doppler global velocimetry. In: 14th international symposium on applications of laser techniques to fluid mechanics, Lisbon, Portugal, p 7.3.4. Exp Fluids. doi:10.​1007/​s00348-009-0647-0
Zurück zum Zitat Meyers JF (1995) Development of Doppler global velocimetry as a flow diagnostics tool. Meas Sci Technol 6:769–783CrossRef Meyers JF (1995) Development of Doppler global velocimetry as a flow diagnostics tool. Meas Sci Technol 6:769–783CrossRef
Zurück zum Zitat Meyers JF, Lee JW, Schwartz RJ (2001) Characterization of measurement error sources in Doppler global velocimetry. Meas Sci Technol 12:357–368CrossRef Meyers JF, Lee JW, Schwartz RJ (2001) Characterization of measurement error sources in Doppler global velocimetry. Meas Sci Technol 12:357–368CrossRef
Zurück zum Zitat Miles RB, Yalin AP, Tang Z, Zaidi SH, Forkey JN (2001) Flow field imaging through sharp-edged atomic and molecular ‘notch’ filters. Meas Sci Technol 12:442–451CrossRef Miles RB, Yalin AP, Tang Z, Zaidi SH, Forkey JN (2001) Flow field imaging through sharp-edged atomic and molecular ‘notch’ filters. Meas Sci Technol 12:442–451CrossRef
Zurück zum Zitat Peiponen KE, Vartiainen EM, Asakura (1998) Dispersion, complex analysis and optical spectroscopy. Springer, Peiponen KE, Vartiainen EM, Asakura (1998) Dispersion, complex analysis and optical spectroscopy. Springer,
Zurück zum Zitat Seiler F, Oertel H (1983) Visualization of velocity fields with Doppler-pictures. In: 3rd Int. Symp. on flow visualization, Ann Arbor Seiler F, Oertel H (1983) Visualization of velocity fields with Doppler-pictures. In: 3rd Int. Symp. on flow visualization, Ann Arbor
Zurück zum Zitat Seiler F, George A, Srulijes J, Havermann M (2008) Flow Progress in Doppler picture velocimetry (DPV). Exp Fluids 44:389–395CrossRef Seiler F, George A, Srulijes J, Havermann M (2008) Flow Progress in Doppler picture velocimetry (DPV). Exp Fluids 44:389–395CrossRef
Zurück zum Zitat Tellinghuisen J (1982) Transition strengths in the visible-infrared absorption spectrum of I2. J Chem Phys 76(10):4736–4744CrossRef Tellinghuisen J (1982) Transition strengths in the visible-infrared absorption spectrum of I2. J Chem Phys 76(10):4736–4744CrossRef
Zurück zum Zitat Willert C, Stockhausen G, Klinner J, Lempereur C, Barricau P, Loiret P, Raynal JC (2007) Performance and accuracy investigations of two Doppler global velocimetry systems in parallel. Meas Sci Technol 18:2504–2512CrossRef Willert C, Stockhausen G, Klinner J, Lempereur C, Barricau P, Loiret P, Raynal JC (2007) Performance and accuracy investigations of two Doppler global velocimetry systems in parallel. Meas Sci Technol 18:2504–2512CrossRef
Metadaten
Titel
Global Doppler frequency shift detection with near-resonant interferometry
verfasst von
Andrin Landolt
Thomas Roesgen
Publikationsdatum
01.10.2009
Verlag
Springer-Verlag
Erschienen in
Experiments in Fluids / Ausgabe 4-5/2009
Print ISSN: 0723-4864
Elektronische ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-009-0688-4

Weitere Artikel der Ausgabe 4-5/2009

Experiments in Fluids 4-5/2009 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.