Skip to main content

2020 | OriginalPaper | Buchkapitel

ID-Fit: Intra-Saccular Device Adjustment for Personalized Cerebral Aneurysm Treatment

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Intrasaccular devices, like Woven EndoBridge (WEB), are novel braided devices employed for the treatment of aneurysms with a complex shape and location, mostly terminal aneurysms. Such aneurysms are often challenging or impossible to treat with other endovascular techniques such as coils, stents, flow diverter stents. The selection of an appropriate endosaccular device size is crucial for a successful treatment and strongly depends of the final configuration that the device adopts when it adapts to the aneurysm sac morphology. This is frequently a problem during the intervention, leading to replacement of the device, reopening of the aneurysm or a need for re-treatment. A technique that allows predicting the released WEB configuration before intervention will provide a powerful computational tool to aid the interventionist during device selection. We propose a technique based on device design and aneurysm morphology that, by virtually deploying a WEB, will enable the assessment of different device sizes before the device implantation. This technique was tested on 6 MCA aneurysm cases and the simulation results were compared to the size of the deployed device on the patient, using post-treatment images.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Pierot, L., Wakhloo, A.K.: Endovascular treatment of intracranial aneurysms - current status. Stroke 44, 2046–2054 (2013)CrossRef Pierot, L., Wakhloo, A.K.: Endovascular treatment of intracranial aneurysms - current status. Stroke 44, 2046–2054 (2013)CrossRef
2.
Zurück zum Zitat Cebral, J.R., Chung, B.J., Mut, F., Chudyk, J., Bleise, C., Scrivano, E., Lylyk, P., Kadirvel, R., Kallmes, D.: Analysis of flow dynamics and outcomes of cerebral aneurysms treated with intrasaccular flow-diverting devices. Am. J. Neuroradiol. 40(9), 1511–1516 (2019) Cebral, J.R., Chung, B.J., Mut, F., Chudyk, J., Bleise, C., Scrivano, E., Lylyk, P., Kadirvel, R., Kallmes, D.: Analysis of flow dynamics and outcomes of cerebral aneurysms treated with intrasaccular flow-diverting devices. Am. J. Neuroradiol. 40(9), 1511–1516 (2019)
3.
Zurück zum Zitat König, I., Weber, A., Weber, W., Fischer, S.: Dislocation of a WEB device into the middle cerebral artery - removal with the alligator retrieval device. Clin Neuroradiol. 29, 361–364 (2019)CrossRef König, I., Weber, A., Weber, W., Fischer, S.: Dislocation of a WEB device into the middle cerebral artery - removal with the alligator retrieval device. Clin Neuroradiol. 29, 361–364 (2019)CrossRef
4.
Zurück zum Zitat Pierot, L., Liebig, T., Sychra, V., Kadziolka, K., Dorn, F., Strasilla, C., Kabbasch, C., Klisch, J.: Intrasaccular flow-disruption treatment of intracranial aneurysms: preliminary results of a multicenter clinical study. Am. J. Neuroradiol. 33(7), 1232–1238 (2012)CrossRef Pierot, L., Liebig, T., Sychra, V., Kadziolka, K., Dorn, F., Strasilla, C., Kabbasch, C., Klisch, J.: Intrasaccular flow-disruption treatment of intracranial aneurysms: preliminary results of a multicenter clinical study. Am. J. Neuroradiol. 33(7), 1232–1238 (2012)CrossRef
5.
Zurück zum Zitat Mut, F., et al.: Image-based modeling of blood flow in cerebral aneurysms treated with intrasaccular flow diverting devices. Numer. Methods Biomed. Eng. 35(6), e3202 (2019)CrossRef Mut, F., et al.: Image-based modeling of blood flow in cerebral aneurysms treated with intrasaccular flow diverting devices. Numer. Methods Biomed. Eng. 35(6), e3202 (2019)CrossRef
6.
Zurück zum Zitat Asnafi, S., Rouchaud, A., Pierot, L., Brinjikji, W., Murad, M.H., Kallmes, D.F.: Efficacy and safety of the Woven Endobridge (WEB) device for the treatment of inracranial aneurysms: a systematic review and meta-analysis. Am J Neuroradiol. 37, 2287–2292 (2016)CrossRef Asnafi, S., Rouchaud, A., Pierot, L., Brinjikji, W., Murad, M.H., Kallmes, D.F.: Efficacy and safety of the Woven Endobridge (WEB) device for the treatment of inracranial aneurysms: a systematic review and meta-analysis. Am J Neuroradiol. 37, 2287–2292 (2016)CrossRef
7.
Zurück zum Zitat Larrabide, I.: Method for determining the final length of stents before the positioning thereof. US Patent App. 14/911,938, August 11 2016 Larrabide, I.: Method for determining the final length of stents before the positioning thereof. US Patent App. 14/911,938, August 11 2016
8.
Zurück zum Zitat Piccinelli, M., Veneziani, A., Steinman, D.A., Remuzzi, A., Antiga, L.: A framework for geometric analysis of vascular structures: application to cerebral aneurysms. IEEE Trans. Med. Imaging 28(8), 1141–1155 (2009)CrossRef Piccinelli, M., Veneziani, A., Steinman, D.A., Remuzzi, A., Antiga, L.: A framework for geometric analysis of vascular structures: application to cerebral aneurysms. IEEE Trans. Med. Imaging 28(8), 1141–1155 (2009)CrossRef
9.
Zurück zum Zitat Fernandez, Hector., Macho, Juan M., Blasco, Jordi., Roman, Luis San., Mailaender, Werner., Serra, Luis, Larrabide, Ignacio: Computation of the change in length of a braided device when deployed in realistic vessel models. Int. J. Comput. Assist. Radiol. Surg. 10(10), 1659–1665 (2015). https://doi.org/10.1007/s11548-015-1230-1CrossRef Fernandez, Hector., Macho, Juan M., Blasco, Jordi., Roman, Luis San., Mailaender, Werner., Serra, Luis, Larrabide, Ignacio: Computation of the change in length of a braided device when deployed in realistic vessel models. Int. J. Comput. Assist. Radiol. Surg. 10(10), 1659–1665 (2015). https://​doi.​org/​10.​1007/​s11548-015-1230-1CrossRef
10.
Zurück zum Zitat Larrabide, I., Villa-Uriol, M.C., Cárdenes, R., Barbarito, V., Carotenuto, L., Geers, A.J., Omedas, P., et al.: Angiolab-a software tool for morphological analysis and endovascular treatment planning of intracranial aneurysms. Comput. Methods Programs Biomed. 108(2), 806–819 (2012)CrossRef Larrabide, I., Villa-Uriol, M.C., Cárdenes, R., Barbarito, V., Carotenuto, L., Geers, A.J., Omedas, P., et al.: Angiolab-a software tool for morphological analysis and endovascular treatment planning of intracranial aneurysms. Comput. Methods Programs Biomed. 108(2), 806–819 (2012)CrossRef
11.
Zurück zum Zitat Popielski, J., Berlis, A., Weber, W., Fisher, S.: Two-Center experience in the endovascular treatment of ruptured and unruptured intracranial aneurysms using the WEB device: a retrospective analysis. Am. J. Neuroradiol. 39(1), 111–117 (2018)CrossRef Popielski, J., Berlis, A., Weber, W., Fisher, S.: Two-Center experience in the endovascular treatment of ruptured and unruptured intracranial aneurysms using the WEB device: a retrospective analysis. Am. J. Neuroradiol. 39(1), 111–117 (2018)CrossRef
Metadaten
Titel
ID-Fit: Intra-Saccular Device Adjustment for Personalized Cerebral Aneurysm Treatment
Copyright-Jahr
2020
DOI
https://doi.org/10.1007/978-3-030-59725-2_10

Premium Partner