Skip to main content
Erschienen in: Machine Vision and Applications 1/2014

01.01.2014 | Original Paper

Image-based magnification calibration for electron microscope

verfasst von: Koichi Ito, Ayako Suzuki, Takafumi Aoki, Ruriko Tsuneta

Erschienen in: Machine Vision and Applications | Ausgabe 1/2014

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Magnification calibration is a crucial task for the electron microscope to achieve accurate measurement of the target object. In general, magnification calibration is performed to obtain the correspondence between the scale of the electron microscope image and the actual size of the target object using the standard calibration samples. However, the current magnification calibration method mentioned above may include a maximum of 5 % scale error, since an alternative method has not yet been proposed. Addressing this problem, this paper proposes an image-based magnification calibration method for the electron microscope. The proposed method employs a multi-stage scale estimation approach using phase-based correspondence matching. Consider a sequence of microscope images of the same target object, where the image magnification is gradually increased so that the final image has a very large scale factor \(S\) (e.g., \(S=1\!,\!\!000\)) with respect to the initial image. The problem considered in this paper is to estimate the overall scale factor \(S\) of the given image sequence. The proposed scale estimation method provides a new methodology for high-accuracy magnification calibration of the electron microscope. This paper also proposes a quantitative performance evaluation method of scale estimation algorithms using Mandelbrot images which are precisely scale-controlled images. Experimental evaluation using Mandelbrot images shows that the proposed scale estimation algorithm can estimate the overall scale factor \(S=1\!,\!\!000\) with approximately 0.1 % scale error. Also, a set of experiments using image sequences taken by an actual scanning transmission electron microscope (STEM) demonstrates that the proposed method is more effective for magnification calibration of a STEM compared with a conventional method.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Backus, R., Williams, R.: Small spherical particles of exceptionally uniform size. J. Appl. Phys. 20, 224–225 (1949)CrossRef Backus, R., Williams, R.: Small spherical particles of exceptionally uniform size. J. Appl. Phys. 20, 224–225 (1949)CrossRef
2.
Zurück zum Zitat Chen, Q., Defrise, M., Deconinck, F.: Symmetric phase-only matched filtering of Fourier–Mellin transforms for image registration and recognition. IEEE Trans. Pattern Anal. Mach. Intell. 16(12), 1156–1168 (1994)CrossRef Chen, Q., Defrise, M., Deconinck, F.: Symmetric phase-only matched filtering of Fourier–Mellin transforms for image registration and recognition. IEEE Trans. Pattern Anal. Mach. Intell. 16(12), 1156–1168 (1994)CrossRef
3.
Zurück zum Zitat Devaney, R.L., Keen, L., Alligood, K.T.: Chaos and Fractals: The Mathematics Behind the Computer Graphics. AMS Bookstore, Providence (1989) Devaney, R.L., Keen, L., Alligood, K.T.: Chaos and Fractals: The Mathematics Behind the Computer Graphics. AMS Bookstore, Providence (1989)
4.
Zurück zum Zitat Fullam, E.: Magnification calibration of the electron microscope. J. Appl. Phys. 14, 677–683 (1943)CrossRef Fullam, E.: Magnification calibration of the electron microscope. J. Appl. Phys. 14, 677–683 (1943)CrossRef
5.
Zurück zum Zitat Kuglin, C.D., Hines, D.C.: The phase correlation image alignment method. In: Proceedings of International Conference Cybernetics and Society, pp. 163–165 (1975) Kuglin, C.D., Hines, D.C.: The phase correlation image alignment method. In: Proceedings of International Conference Cybernetics and Society, pp. 163–165 (1975)
6.
Zurück zum Zitat Lowe, D.: Distinctive image features from scale-invariant keypoints. Int. J. Comput. Vis. 60(2), 91–110 (2004)CrossRef Lowe, D.: Distinctive image features from scale-invariant keypoints. Int. J. Comput. Vis. 60(2), 91–110 (2004)CrossRef
7.
Zurück zum Zitat Olson, N., Baker, T.: Magnification calibration and the determination of spherical virus diameters using cryo-microscopy. Ultramicroscopy 30(3), 281–298 (1989)CrossRef Olson, N., Baker, T.: Magnification calibration and the determination of spherical virus diameters using cryo-microscopy. Ultramicroscopy 30(3), 281–298 (1989)CrossRef
8.
Zurück zum Zitat Szeliski, R.: Computer Vision: Algorithms and Applications. Springer, Berlin (2010) Szeliski, R.: Computer Vision: Algorithms and Applications. Springer, Berlin (2010)
9.
Zurück zum Zitat Takita, K., Aoki, T., Sasaki, Y., Higuchi, T., Kobayashi, K.: High-accuracy subpixel image registration based on phase-only correlation. IEICE Trans. Fundam. E86-A(8), 1925–1934 (2003) Takita, K., Aoki, T., Sasaki, Y., Higuchi, T., Kobayashi, K.: High-accuracy subpixel image registration based on phase-only correlation. IEICE Trans. Fundam. E86-A(8), 1925–1934 (2003)
10.
Zurück zum Zitat Takita, K., Muquit, M.A., Aoki, T., Higuchi, T.: A sub-pixel correspondence search technique for computer vision applications. IEICE Trans. Fundam. E87-A(8), 1913–1923 (2004) Takita, K., Muquit, M.A., Aoki, T., Higuchi, T.: A sub-pixel correspondence search technique for computer vision applications. IEICE Trans. Fundam. E87-A(8), 1913–1923 (2004)
11.
Zurück zum Zitat van der Laak, J.A.W.M., Dijkman, H.B.P.M., Pahlplatz, M.M.M.: Automated magnification calibration in transmission electron microscopy using Fourier analysis of replica images. Ultramicroscopy 106(4–5), 255–260 (2006)CrossRef van der Laak, J.A.W.M., Dijkman, H.B.P.M., Pahlplatz, M.M.M.: Automated magnification calibration in transmission electron microscopy using Fourier analysis of replica images. Ultramicroscopy 106(4–5), 255–260 (2006)CrossRef
12.
Zurück zum Zitat Wrigley, N.: The lattice spacing of crystalline catalase as an internal standard of length in electron microscopy. J. Ultrastruct. Res. 24, 454–464 (1968)CrossRef Wrigley, N.: The lattice spacing of crystalline catalase as an internal standard of length in electron microscopy. J. Ultrastruct. Res. 24, 454–464 (1968)CrossRef
13.
Zurück zum Zitat Zhao, F., Yang, Y.: Use of monodisperse gold nanoperticles for transmission electron microscope high magnification calibration. Colloid J. 72(3), 346–352 (2010)CrossRef Zhao, F., Yang, Y.: Use of monodisperse gold nanoperticles for transmission electron microscope high magnification calibration. Colloid J. 72(3), 346–352 (2010)CrossRef
Metadaten
Titel
Image-based magnification calibration for electron microscope
verfasst von
Koichi Ito
Ayako Suzuki
Takafumi Aoki
Ruriko Tsuneta
Publikationsdatum
01.01.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Machine Vision and Applications / Ausgabe 1/2014
Print ISSN: 0932-8092
Elektronische ISSN: 1432-1769
DOI
https://doi.org/10.1007/s00138-013-0511-3

Weitere Artikel der Ausgabe 1/2014

Machine Vision and Applications 1/2014 Zur Ausgabe