Impact of Switching Three-Phase Breaker at Different Period on Inter-turn Protection for High-Voltage Shunt Reactor

verfasst von : Sheng-Hong Lin, Shu-Yan Pan, Hua-Ren Wu

Erschienen in: Proceedings of the 5th International Conference on Electrical Engineering and Automatic Control

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In this paper, the simulation of inter-turn protection for high-voltage (HV) shunt reactors is studied by using Simulink. Expound that when the closing angles of the three-phase circuit breaker are different, the zero-sequence current and zero-sequence voltage will occur in the system. Demonstrated that during such time, the protection criterion of inter-turn protection will be satisfied in some cases, and thus, the false tripping will occur possibly. Finally, some suggestions are given to avoid the false tripping in the inter-turn protection.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Dvorak LL, Chalrman DC, Dawson RW, Dempsey H, Disante CM, Gadsden JD, Huddleston III, Schulze LJ (1991) Summary of the ‘Guide for the protection of shunt reactors’ ANSI C37.109. IEEE Trans Power Deliv 6(1):116–118 Dvorak LL, Chalrman DC, Dawson RW, Dempsey H, Disante CM, Gadsden JD, Huddleston III, Schulze LJ (1991) Summary of the ‘Guide for the protection of shunt reactors’ ANSI C37.109. IEEE Trans Power Deliv 6(1):116–118
2.
Zurück zum Zitat He J, Li Y, Guo Z, Li B, Dong X (2002) Relay protection for UHV transmission lines. Autom Electric Power Syst 26(2):1–6 He J, Li Y, Guo Z, Li B, Dong X (2002) Relay protection for UHV transmission lines. Autom Electric Power Syst 26(2):1–6
3.
Zurück zum Zitat Ban G, Prikler L, Banfai G (2003) 750 kV reactive power control automatic reclosing and overvoltage protection. IEEE Power Tech Conference, IEEE, Bologna, Italy Ban G, Prikler L, Banfai G (2003) 750 kV reactive power control automatic reclosing and overvoltage protection. IEEE Power Tech Conference, IEEE, Bologna, Italy
4.
Zurück zum Zitat Chen S, Wang Z (2003) Research and development of a new digital shunt reactor protection. Autom Electric Power Syst 27(24):70–73 Chen S, Wang Z (2003) Research and development of a new digital shunt reactor protection. Autom Electric Power Syst 27(24):70–73
5.
Zurück zum Zitat Sun Q, Li Q, Wang G (2010) Characteristic analysis of shunt reactor swtiching over-voltages interrupted by SF6 circuit breaker with chopping current. Trans China Electrotech Soc 25(2):170–176 Sun Q, Li Q, Wang G (2010) Characteristic analysis of shunt reactor swtiching over-voltages interrupted by SF6 circuit breaker with chopping current. Trans China Electrotech Soc 25(2):170–176
6.
Zurück zum Zitat Chang W, Huang M (2002) Modeling SF6 circuit breaker for characterizing shunt reactor switching transients. IEEE Trans Power Deliv 11(3):1533–1540 Chang W, Huang M (2002) Modeling SF6 circuit breaker for characterizing shunt reactor switching transients. IEEE Trans Power Deliv 11(3):1533–1540
7.
Zurück zum Zitat Prikler L, Ban G, Banfai G (1997) EMTP models for simulation of shunt reactor switching transients. Electr Power Energy Syst 19(4):235–240CrossRef Prikler L, Ban G, Banfai G (1997) EMTP models for simulation of shunt reactor switching transients. Electr Power Energy Syst 19(4):235–240CrossRef
8.
Zurück zum Zitat Yang D (1992) Test and research on disconnecting shunt reactors with SF6 breakers. High Volt Eng 22(2):50–55 Yang D (1992) Test and research on disconnecting shunt reactors with SF6 breakers. High Volt Eng 22(2):50–55
9.
Zurück zum Zitat Pan X, Wang X, Wang B (2000) Analysis and criterion of eliminating the need for closing resistors in 500 kV line circuit breaker. Electr Switch 4:24–30 Pan X, Wang X, Wang B (2000) Analysis and criterion of eliminating the need for closing resistors in 500 kV line circuit breaker. Electr Switch 4:24–30
10.
Zurück zum Zitat An Y, Wen X (2013) Overvoltage of shunt reactor by prebreakdown of SF6 breaker and protection measures. High Volt Eng 39(1):75–80 An Y, Wen X (2013) Overvoltage of shunt reactor by prebreakdown of SF6 breaker and protection measures. High Volt Eng 39(1):75–80
11.
Zurück zum Zitat Hu N (2011) Investigations on controlled switching of shunt reactor. Dalian University of Technology, Dalian Hu N (2011) Investigations on controlled switching of shunt reactor. Dalian University of Technology, Dalian
12.
Zurück zum Zitat Wang W, Huang R (1995) Operation analysis of the zero sequence directional power protection in 500 kV shunt reactor. Relay 4:3–6 Wang W, Huang R (1995) Operation analysis of the zero sequence directional power protection in 500 kV shunt reactor. Relay 4:3–6
Metadaten
Titel
Impact of Switching Three-Phase Breaker at Different Period on Inter-turn Protection for High-Voltage Shunt Reactor
verfasst von
Sheng-Hong Lin
Shu-Yan Pan
Hua-Ren Wu
Copyright-Jahr
2016
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-662-48768-6_109

Neuer Inhalt