Skip to main content
Erschienen in: Experiments in Fluids 3/2003

01.09.2003 | Original

Optimal subpixel interpolation in particle image velocimetry

verfasst von: T. Roesgen

Erschienen in: Experiments in Fluids | Ausgabe 3/2003

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

It is shown that among the different techniques for particle image velocimetry subpixel interpolation, only the "sinc"-kernel creates an optimal result in that it completely suppresses spurious spectral sidelobes. An efficient method is introduced for the computation of the subpixel-accurate correlation peak position without any systematic errors. A connection is made with the kernel-dependent observation of the peak-locking phenomenon.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Alexander BF, Ng KC (1991) Elimination of systematic error in subpixel accuracy centroid estimation. Opt. Eng 30:1320–1331 Alexander BF, Ng KC (1991) Elimination of systematic error in subpixel accuracy centroid estimation. Opt. Eng 30:1320–1331
Zurück zum Zitat Fincham A, Delerce G (2000) Advanced optimization of correlation imaging velocimetry algorithms. Exp Fluids 29:S13–S22CrossRef Fincham A, Delerce G (2000) Advanced optimization of correlation imaging velocimetry algorithms. Exp Fluids 29:S13–S22CrossRef
Zurück zum Zitat Forliti DJ, Strykowski PJ, Debatin K (2000) Bias and precision errors of digital particle image velocimetry. Exp Fluids 28:436–447CrossRef Forliti DJ, Strykowski PJ, Debatin K (2000) Bias and precision errors of digital particle image velocimetry. Exp Fluids 28:436–447CrossRef
Zurück zum Zitat Gui L, Wereley ST (2002) A correlation-based continuous window-shift technique to reduce the peak locking effect in digital PIV image evaluation. Exp Fluids 32:506–517CrossRef Gui L, Wereley ST (2002) A correlation-based continuous window-shift technique to reduce the peak locking effect in digital PIV image evaluation. Exp Fluids 32:506–517CrossRef
Zurück zum Zitat Keane RD, Adrian RJ (1992) Theory of cross correlation analysis of PIV images. J Appl Sci Res 49:191–215 Keane RD, Adrian RJ (1992) Theory of cross correlation analysis of PIV images. J Appl Sci Res 49:191–215
Zurück zum Zitat Lourenco I, Krothapalli A (1995) On the accuracy of velocity and vorticity measurements with PIV. Exp Fluids 18:421–428 Lourenco I, Krothapalli A (1995) On the accuracy of velocity and vorticity measurements with PIV. Exp Fluids 18:421–428
Zurück zum Zitat Meinhart CD, Wereley ST, Santiago JG (2000) A PIV algorithm for estimating time-averaged velocity fields. J Fluids Eng 122:285–289CrossRef Meinhart CD, Wereley ST, Santiago JG (2000) A PIV algorithm for estimating time-averaged velocity fields. J Fluids Eng 122:285–289CrossRef
Zurück zum Zitat Nogueira J, Lecuona A, Rodriguez PA (2001) Identification of a new source of peak locking, analysis and its removal in conventional and super-resolution PIV techniques. Exp Fluids 30:309–316CrossRef Nogueira J, Lecuona A, Rodriguez PA (2001) Identification of a new source of peak locking, analysis and its removal in conventional and super-resolution PIV techniques. Exp Fluids 30:309–316CrossRef
Zurück zum Zitat Scarano F (2002) Iterative image deformation methods in PIV. Meas Sci Technol 13:R1–R19 Scarano F (2002) Iterative image deformation methods in PIV. Meas Sci Technol 13:R1–R19
Zurück zum Zitat Sjödahl M (1994) Electronic speckle photography: increased accuracy by nonintegral pixel shifting. Appl Optics 33(28):6667–66673 Sjödahl M (1994) Electronic speckle photography: increased accuracy by nonintegral pixel shifting. Appl Optics 33(28):6667–66673
Zurück zum Zitat Westerweel J (1998) Effect of sensor geometry on the performance of PIV interrogation. In: Adrian RJ, Durao DFG, Durst F, Heitor MV,Maeda M,Whitelaw JH (eds) Laser techniques applied to fluid mechanics. Springer, Berlin Heidelberg New York Westerweel J (1998) Effect of sensor geometry on the performance of PIV interrogation. In: Adrian RJ, Durao DFG, Durst F, Heitor MV,Maeda M,Whitelaw JH (eds) Laser techniques applied to fluid mechanics. Springer, Berlin Heidelberg New York
Zurück zum Zitat Willert CE, Gharib M (1991) Digital particle image velocimetry. Exp Fluids 10:181–193 Willert CE, Gharib M (1991) Digital particle image velocimetry. Exp Fluids 10:181–193
Metadaten
Titel
Optimal subpixel interpolation in particle image velocimetry
verfasst von
T. Roesgen
Publikationsdatum
01.09.2003
Verlag
Springer-Verlag
Erschienen in
Experiments in Fluids / Ausgabe 3/2003
Print ISSN: 0723-4864
Elektronische ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-003-0627-8

Weitere Artikel der Ausgabe 3/2003

Experiments in Fluids 3/2003 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.