This paper reviews the literature concerning the energy savings that can be achieved through optimized building shape and form, improved building envelopes, improved efficiencies of individual energy-using devices, alternative energy using systems in buildings, and through enlightened occupant behavior and operation of building systems. Cost information is also provided. Both new buildings and retrofits are discussed. Energy-relevant characteristics of the building envelope include window-to-wall ratios, insulation levels of the walls and roof, thermal resistance and solar heat gain coefficient of windows, degree of air tightness to prevent unwanted exchange of air between the inside and outside, and presence or absence of operable windows that connect to pathways for passive ventilation. Provision of a high-performance envelope is the single most important factor in the design of low-energy buildings, not only because it reduces the heating and cooling loads that the mechanical system must satisfy but also because it permits alternative (and low-energy) systems for meeting the reduced loads. In many cases, equipment with significantly greater efficiency than is currently used is available. However, the savings available through better and alternative energy-using systems (such as alternative heating, ventilation, cooling, and lighting systems) are generally much larger than the savings that can be achieved by using more efficient devices (such as boilers, fans, chillers, and lamps). Because improved building envelopes and improved building systems reduce the need for mechanical heating and cooling equipment, buildings with dramatically lower energy use (50–75% savings) often entail no greater construction cost than conventional design while yielding significant annual energy-cost savings.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Fußnoten
1
Primary energy in the case of electricity is the energy used by the power plant and is about three times the energy content of the electricity used by the building.
 
Literatur
Zurück zum Zitat Anderson, R., Christensen, C., & Horowitz, S. (2006). Analysis of residential system strategies targeting least-cost solutions leading to net zero energy homes. ASHRAE Transactions, 112(Part 2), 330–341. Anderson, R., Christensen, C., & Horowitz, S. (2006). Analysis of residential system strategies targeting least-cost solutions leading to net zero energy homes. ASHRAE Transactions, 112(Part 2), 330–341.
Zurück zum Zitat Armstrong, P. R., Leeb, S. B., & Norford, L. K. (2006). Control with building mass—Part II, Simulation. ASHRAE Transactions, 112(Part 1), 462–473. Armstrong, P. R., Leeb, S. B., & Norford, L. K. (2006). Control with building mass—Part II, Simulation. ASHRAE Transactions, 112(Part 1), 462–473.
Zurück zum Zitat Audenaert, A., De Cleyn, S. H., & Vankerckhove, B. (2008). Economic analysis of passive houses and low-energy houses compared with standard houses. Energy Policy, 36, 47–55.CrossRef Audenaert, A., De Cleyn, S. H., & Vankerckhove, B. (2008). Economic analysis of passive houses and low-energy houses compared with standard houses. Energy Policy, 36, 47–55.CrossRef
Zurück zum Zitat Badescu, V., & Sicre, B. (2003). Renewable energy for passive house heating Part 1. Building description. Energy and Buildings, 35, 1077–1084.CrossRef Badescu, V., & Sicre, B. (2003). Renewable energy for passive house heating Part 1. Building description. Energy and Buildings, 35, 1077–1084.CrossRef
Zurück zum Zitat Baird, G. (2001). The Architectural Expression of Environmental Control Systems p. 264. London: Spon Press. Baird, G. (2001). The Architectural Expression of Environmental Control Systems p. 264. London: Spon Press.
Zurück zum Zitat Balaras, C. A. (2001). Energy retrofit of a neoclassic office building—Social aspects and lessons learned. ASHRAE Transactions, 107(Part 1), 191–197. Balaras, C. A. (2001). Energy retrofit of a neoclassic office building—Social aspects and lessons learned. ASHRAE Transactions, 107(Part 1), 191–197.
Zurück zum Zitat Beeler, A. G. (1998). Integrated design team management within the context of environmental systems theory. Proceedings of the 1998 ACEEE Summer Study on Energy Efficiency in Buildings, 10, 19–30 American Council for an Energy Efficient Economy, Washington. Beeler, A. G. (1998). Integrated design team management within the context of environmental systems theory. Proceedings of the 1998 ACEEE Summer Study on Energy Efficiency in Buildings, 10, 19–30 American Council for an Energy Efficient Economy, Washington.
Zurück zum Zitat Bell, M., & Lowe, R. (2000). Energy efficient modernisation of housing, a UK case study. Energy and Buildings, 32, 267–280.CrossRef Bell, M., & Lowe, R. (2000). Energy efficient modernisation of housing, a UK case study. Energy and Buildings, 32, 267–280.CrossRef
Zurück zum Zitat Boonstra, C., Thijssen, I., & Vollebregt, R. (1997). Glazed Balconies in Building Renovation p. 16. London: James & James. Boonstra, C., Thijssen, I., & Vollebregt, R. (1997). Glazed Balconies in Building Renovation p. 16. London: James & James.
Zurück zum Zitat Bourassa, N., Haves, P., & Huang, J. (2002). A computer simulation appraisal of non-residential low energy cooling systems in California. Proceedings of the 2002 ACEEE Summer Study on Energy Efficiency in Buildings, 3, 41–53 American Council for an Energy Efficient Economy, Washington. Bourassa, N., Haves, P., & Huang, J. (2002). A computer simulation appraisal of non-residential low energy cooling systems in California. Proceedings of the 2002 ACEEE Summer Study on Energy Efficiency in Buildings, 3, 41–53 American Council for an Energy Efficient Economy, Washington.
Zurück zum Zitat Çakmanus, I. (2007). Renovation of existing office buildings in regard to energy economy, An example from Ankara, Turkey. Building and Environment, 42, 1348–1357.CrossRef Çakmanus, I. (2007). Renovation of existing office buildings in regard to energy economy, An example from Ankara, Turkey. Building and Environment, 42, 1348–1357.CrossRef
Zurück zum Zitat Claridge, D. E., Liu, M., Deng, S., Turner, W. D., Haberl, J. S., Lee, S. U., et al. (2001). Cutting heating and cooling use almost in half without capital expenditure in a previously retrofit building. European Council for an Energy Efficient Economy, 2001 Summer Proceedings, 4, 74–85. Claridge, D. E., Liu, M., Deng, S., Turner, W. D., Haberl, J. S., Lee, S. U., et al. (2001). Cutting heating and cooling use almost in half without capital expenditure in a previously retrofit building. European Council for an Energy Efficient Economy, 2001 Summer Proceedings, 4, 74–85.
Zurück zum Zitat Cohen, R., Bordass, W., & Leaman, A. (2007). Evaluations and comparisons of the achieved energy and environmental performance of two library buildings in England and Sweden. ASHRAE Transactions, 113(Part 2), 14–26. Cohen, R., Bordass, W., & Leaman, A. (2007). Evaluations and comparisons of the achieved energy and environmental performance of two library buildings in England and Sweden. ASHRAE Transactions, 113(Part 2), 14–26.
Zurück zum Zitat Dascalaki, E., & Santamouris, M. (2002). On the potential of retrofitting scenarios for offices. Building and Environment, 37, 557–567.CrossRef Dascalaki, E., & Santamouris, M. (2002). On the potential of retrofitting scenarios for offices. Building and Environment, 37, 557–567.CrossRef
Zurück zum Zitat de Dear, R. J., & Brager, G. S. (1998). Developing an adaptive model of thermal comfort and preference. ASHRAE Transactions, 104(Part 1A), 145–167. de Dear, R. J., & Brager, G. S. (1998). Developing an adaptive model of thermal comfort and preference. ASHRAE Transactions, 104(Part 1A), 145–167.
Zurück zum Zitat de Dear, R. J., & Brager, G. S. (2002). Thermal comfort in naturally ventilated buildings, revisions to ASHRAE Standard 55. Energy and Buildings, 34, 549–561.CrossRef de Dear, R. J., & Brager, G. S. (2002). Thermal comfort in naturally ventilated buildings, revisions to ASHRAE Standard 55. Energy and Buildings, 34, 549–561.CrossRef
Zurück zum Zitat Demirbilek, F. N., Yalçiner, U. G., Inanici, M. N., Ecevit, A., & Demirbilek, O. S. (2000). Energy conscious dwelling design for Ankara. Building and Environment, 35, 33–40.CrossRef Demirbilek, F. N., Yalçiner, U. G., Inanici, M. N., Ecevit, A., & Demirbilek, O. S. (2000). Energy conscious dwelling design for Ankara. Building and Environment, 35, 33–40.CrossRef
Zurück zum Zitat Durkin, T. H. (2006). Boiler system efficiency. ASHRAE Journal, 48(7), 51–57. Durkin, T. H. (2006). Boiler system efficiency. ASHRAE Journal, 48(7), 51–57.
Zurück zum Zitat Eicker, U., Huber, M., Seeberger, P., & Vorschulze, C. (2006). Limits and potentials of office building climatisation with ambient air. Energy and Buildings, 38, 574–581.CrossRef Eicker, U., Huber, M., Seeberger, P., & Vorschulze, C. (2006). Limits and potentials of office building climatisation with ambient air. Energy and Buildings, 38, 574–581.CrossRef
Zurück zum Zitat Feist, W., Schnieders, J., Dorer, V., & Haas, A. (2005). Re-inventing air heating: Convenient and comfortable within the frame of the Passive House concept. Energy and Buildings, 37, 1186–1203.CrossRef Feist, W., Schnieders, J., Dorer, V., & Haas, A. (2005). Re-inventing air heating: Convenient and comfortable within the frame of the Passive House concept. Energy and Buildings, 37, 1186–1203.CrossRef
Zurück zum Zitat Fisher, D., Schmid, F., & Spata, A. J. (1999). Estimating the energy-saving benefit of reduced-flow and/or multi-speed commercial kitchen ventilation systems. ASHRAE Transactions, 105(Part 1), 1138–1151. Fisher, D., Schmid, F., & Spata, A. J. (1999). Estimating the energy-saving benefit of reduced-flow and/or multi-speed commercial kitchen ventilation systems. ASHRAE Transactions, 105(Part 1), 1138–1151.
Zurück zum Zitat Florides, G. A., Tassou, S. A., Kalogirou, S. A., & Wrobel, L. C. (2002). Measures used to lower building energy consumption and their cost effectiveness. Applied Energy, 73, 299–328.CrossRef Florides, G. A., Tassou, S. A., Kalogirou, S. A., & Wrobel, L. C. (2002). Measures used to lower building energy consumption and their cost effectiveness. Applied Energy, 73, 299–328.CrossRef
Zurück zum Zitat Ford, B., Patel, N., Zaveri, P., & Hewitt, M. (1998). Cooling without air conditioning: The Torrent Research Centre, Ahmedabad, India. Renewable Energy, 15, 177–182.CrossRef Ford, B., Patel, N., Zaveri, P., & Hewitt, M. (1998). Cooling without air conditioning: The Torrent Research Centre, Ahmedabad, India. Renewable Energy, 15, 177–182.CrossRef
Zurück zum Zitat Fountain, M. E., Arens, E., Xu, T., Bauman, F. S., & Oguru, M. (1999). An investigation of thermal comfort at high humidities. ASHRAE Transactions, 105, 94–103. Fountain, M. E., Arens, E., Xu, T., Bauman, F. S., & Oguru, M. (1999). An investigation of thermal comfort at high humidities. ASHRAE Transactions, 105, 94–103.
Zurück zum Zitat Francisco, P. W., Palmiter, L., & Davis, B. (1998). Modeling the thermal distribution efficiency of ducts, comparisons to measured results. Energy and Buildings, 28, 287–297.CrossRef Francisco, P. W., Palmiter, L., & Davis, B. (1998). Modeling the thermal distribution efficiency of ducts, comparisons to measured results. Energy and Buildings, 28, 287–297.CrossRef
Zurück zum Zitat Gamble, D., Dean, B., Meisegeier, D., & Hall, J. (2004). Building a path towards zero energy homes with energy efficient upgrades. Proceedings of the 2004 ACEEE Summer Study on Energy Efficiency in Buildings, 1, 95–106 American Council for an Energy Efficient Economy, Washington. Gamble, D., Dean, B., Meisegeier, D., & Hall, J. (2004). Building a path towards zero energy homes with energy efficient upgrades. Proceedings of the 2004 ACEEE Summer Study on Energy Efficiency in Buildings, 1, 95–106 American Council for an Energy Efficient Economy, Washington.
Zurück zum Zitat Gauzin-Müller, D. (2002). Sustainable Architecture and Urbanism p. 255. Basel: Birkhäuser. Gauzin-Müller, D. (2002). Sustainable Architecture and Urbanism p. 255. Basel: Birkhäuser.
Zurück zum Zitat Genest, F., & Minea, V. (2006). High-performance retail store with integrated HVAC systems. ASHRAE Transactions, 112(Part 2), 342–348. Genest, F., & Minea, V. (2006). High-performance retail store with integrated HVAC systems. ASHRAE Transactions, 112(Part 2), 342–348.
Zurück zum Zitat Grut, L. (2003). Daimler Chrysler Building, Berlin. In B. Edwards (Ed.), Green Buildings Pay (pp. 86–93). London: Spon Press. Grut, L. (2003). Daimler Chrysler Building, Berlin. In B. Edwards (Ed.), Green Buildings Pay (pp. 86–93). London: Spon Press.
Zurück zum Zitat Haller, A., Schweizer, E., Braun, P. O., & Voss, K. (1997). Transparent Insulation in Building Renovation p. 16. London: James & James. Haller, A., Schweizer, E., Braun, P. O., & Voss, K. (1997). Transparent Insulation in Building Renovation p. 16. London: James & James.
Zurück zum Zitat Hamada, Y., Nakamura, M., Ochifuji, K., Yokoyama, S., & Nagano, K. (2003). Development of a database of low energy homes around the world and analysis of their trends. Renewable Energy, 28, 321–328.CrossRef Hamada, Y., Nakamura, M., Ochifuji, K., Yokoyama, S., & Nagano, K. (2003). Development of a database of low energy homes around the world and analysis of their trends. Renewable Energy, 28, 321–328.CrossRef
Zurück zum Zitat Harvey, L. D. D. (2006). A Handbook on Low-Energy Buildings and District-Energy Systems p. 701. London: Earthscan. Harvey, L. D. D. (2006). A Handbook on Low-Energy Buildings and District-Energy Systems p. 701. London: Earthscan.
Zurück zum Zitat Harvey, L. D. D. (2007a). Dangerous anthropogenic interference, dangerous climatic change, and harmful climatic change, non-trivial distinctions with significant policy implications. Climatic Change, 82, 1–25.CrossRef Harvey, L. D. D. (2007a). Dangerous anthropogenic interference, dangerous climatic change, and harmful climatic change, non-trivial distinctions with significant policy implications. Climatic Change, 82, 1–25.CrossRef
Zurück zum Zitat Harvey, L. D. D. (2007b). Allowable CO2 Concentrations under the United Nations framework convention on climate change as a function of the climate sensitivity PDF. Environmental Research Letters, 2, 014001. doi:10.1088/1748-9326/2/1/014001.CrossRef Harvey, L. D. D. (2007b). Allowable CO2 Concentrations under the United Nations framework convention on climate change as a function of the climate sensitivity PDF. Environmental Research Letters, 2, 014001. doi:10.​1088/​1748-9326/​2/​1/​014001.CrossRef
Zurück zum Zitat Harvey, L. D. D. (2008). Energy savings by treating buildings as systems. In D. Hafemeister, B. Levi, M.D. Levine, & P. Schwartz (Eds.), Physics of Sustainable Energy, Using Energy Efficiently and Producing it Renewably, American Institute of Physics Conference Series (pp. 67–87). College Park: American Physics Society. Harvey, L. D. D. (2008). Energy savings by treating buildings as systems. In D. Hafemeister, B. Levi, M.D. Levine, & P. Schwartz (Eds.), Physics of Sustainable Energy, Using Energy Efficiently and Producing it Renewably, American Institute of Physics Conference Series (pp. 67–87). College Park: American Physics Society.
Zurück zum Zitat Harvey, L. D. D., & Siddall, M. (2008). Advanced glazing systems and the economics of comfort. Green Building Magazine, Spring 08, 30–35. Harvey, L. D. D., & Siddall, M. (2008). Advanced glazing systems and the economics of comfort. Green Building Magazine, Spring 08, 30–35.
Zurück zum Zitat Hastings, S. R. (2004). Breaking the. heating barrier’ Learning from the first houses without conventional heating. Energy and Buildings, 36, 373–380.CrossRef Hastings, S. R. (2004). Breaking the. heating barrier’ Learning from the first houses without conventional heating. Energy and Buildings, 36, 373–380.CrossRef
Zurück zum Zitat Hastings, R., & Wall, M. (2007a). Sustainable Solar Housing, Volume 1, Strategies and Solutions p. 292. London: Earthscan. Hastings, R., & Wall, M. (2007a). Sustainable Solar Housing, Volume 1, Strategies and Solutions p. 292. London: Earthscan.
Zurück zum Zitat Hastings, R., & Wall, M. (2007b). Sustainable Solar Housing, Volume2, Exemplary Buildings and Technologies p. 262. London: Earthscan. Hastings, R., & Wall, M. (2007b). Sustainable Solar Housing, Volume2, Exemplary Buildings and Technologies p. 262. London: Earthscan.
Zurück zum Zitat Hawkes, D., & Forster, W. (2002). Energy Efficient Buildings, Architecture, Engineering, and Environment p. 240. New York: Norton. Hawkes, D., & Forster, W. (2002). Energy Efficient Buildings, Architecture, Engineering, and Environment p. 240. New York: Norton.
Zurück zum Zitat Hestnes, A. G., & Kofoed, N. U. (1997). OFFICE, Passive Retrofitting of Office Buildings to Improve their Energy Performance and Indoor Environment, Final Report of the Design and Evaluation Subgroup. European Commission Directorate General for Science Research and Development, JOULE Programme, JOR3-CT96-0034. Hestnes, A. G., & Kofoed, N. U. (1997). OFFICE, Passive Retrofitting of Office Buildings to Improve their Energy Performance and Indoor Environment, Final Report of the Design and Evaluation Subgroup. European Commission Directorate General for Science Research and Development, JOULE Programme, JOR3-CT96-0034.
Zurück zum Zitat Hestnes, A. G., & Kofoed, N. U. (2002). Effective retrofitting scenarios for energy efficiency and comfort, results of the design and evaluation activities within the OFFICE project. Building and Environment, 37, 569–574.CrossRef Hestnes, A. G., & Kofoed, N. U. (2002). Effective retrofitting scenarios for energy efficiency and comfort, results of the design and evaluation activities within the OFFICE project. Building and Environment, 37, 569–574.CrossRef
Zurück zum Zitat Holford, J. M., & Hunt, G. R. (2003). Fundamental atrium design for natural ventilation. Building and Environment, 38, 409–426.CrossRef Holford, J. M., & Hunt, G. R. (2003). Fundamental atrium design for natural ventilation. Building and Environment, 38, 409–426.CrossRef
Zurück zum Zitat Holton, J. K. (2002). Base loads (lighting, appliances, DHW) and the high performance house. ASHRAE Transactions, 108(Part 1), 232–242. Holton, J. K. (2002). Base loads (lighting, appliances, DHW) and the high performance house. ASHRAE Transactions, 108(Part 1), 232–242.
Zurück zum Zitat Howe, M., Holland, D., & Livchak, A. (2003). Displacement ventilation—Smart way to deal with increased heat gains in the telecommunication equipment room. ASHRAE Transactions, 109(Part 1), 323–327. Howe, M., Holland, D., & Livchak, A. (2003). Displacement ventilation—Smart way to deal with increased heat gains in the telecommunication equipment room. ASHRAE Transactions, 109(Part 1), 323–327.
Zurück zum Zitat Hughes, P. J., & Shonder, J. A. (1998). The Evaluation of a 4000-Home geothermal heat pump retrofit at Fort Polk, Louisiana, Final Report, Oak Ridge National Laboratory, ORNL/CON-460. Hughes, P. J., & Shonder, J. A. (1998). The Evaluation of a 4000-Home geothermal heat pump retrofit at Fort Polk, Louisiana, Final Report, Oak Ridge National Laboratory, ORNL/CON-460.
Zurück zum Zitat Humm, O. (2000). Ecology and economy when retrofitting apartment buildings. IEA Heat Pump Centre Newsletter, 15(4), 17–18. Humm, O. (2000). Ecology and economy when retrofitting apartment buildings. IEA Heat Pump Centre Newsletter, 15(4), 17–18.
Zurück zum Zitat IEA (International Energy Agency) (2004). Oil Crises & Climate Challenges: 30 Years of Energy Use in IEA Countries, International Energy Agency, Paris, 211 pp. IEA (International Energy Agency) (2004). Oil Crises & Climate Challenges: 30 Years of Energy Use in IEA Countries, International Energy Agency, Paris, 211 pp.
Zurück zum Zitat Interface Engineering, (2005). Engineering a Sustainable World, Design Process and Engineering Innovations for the Center for Health and Healing at the Oregan Health and Science University, River Campus. Available through www.interface-engineering.com. Interface Engineering, (2005). Engineering a Sustainable World, Design Process and Engineering Innovations for the Center for Health and Healing at the Oregan Health and Science University, River Campus. Available through www.​interface-engineering.​com.
Zurück zum Zitat Kats, G., Alevantis, L., Berman, A., Mills, E., & Perlman, J. (2003). The Costs and Financial Benefits of Green Buildings, A Report to California’s Sustainable Building Task Force. Sustainable Building Task Force, 120 pages. Kats, G., Alevantis, L., Berman, A., Mills, E., & Perlman, J. (2003). The Costs and Financial Benefits of Green Buildings, A Report to California’s Sustainable Building Task Force. Sustainable Building Task Force, 120 pages.
Zurück zum Zitat Krapmeier, H., & Drössler, E. (2001). CEPHEUS, Living Comfort Without Heating p. 139. Vienna: Springer. Krapmeier, H., & Drössler, E. (2001). CEPHEUS, Living Comfort Without Heating p. 139. Vienna: Springer.
Zurück zum Zitat Larsson, N. (2001). Canadian green building strategies. In The 18th International Conference on Passive and Low Energy Architecture, Brazil, 7–9 November 2001, pp 17–25. Larsson, N. (2001). Canadian green building strategies. In The 18th International Conference on Passive and Low Energy Architecture, Brazil, 7–9 November 2001, pp 17–25.
Zurück zum Zitat Lee, K. H., & Strand, R. K. (2008). The cooling and heating potential of an earth tube system in buildings. Energy and Buildings, 40, 486–494.CrossRef Lee, K. H., & Strand, R. K. (2008). The cooling and heating potential of an earth tube system in buildings. Energy and Buildings, 40, 486–494.CrossRef
Zurück zum Zitat Lemire, N., & Charneux, R. (2005). Energy-efficiency laboratory design. ASHRAE Journal, 47(5), 58–64. Lemire, N., & Charneux, R. (2005). Energy-efficiency laboratory design. ASHRAE Journal, 47(5), 58–64.
Zurück zum Zitat Levermore, G. J. (2000). Building Energy Management Systems, Applications to Low-Energy HVAC and Natural Ventilation Control p. 519. London: Spon. Levermore, G. J. (2000). Building Energy Management Systems, Applications to Low-Energy HVAC and Natural Ventilation Control p. 519. London: Spon.
Zurück zum Zitat Levine, M., Ürge-Vorsatz, D., Blok, K., Geng, L., Harvey, D., Lang, S., et al. (2007). Residential and commercial buildings. In B. Metz, O.R. Davidson, P.R. Bosch, R. Dave, & L.A. Meyer (Eds.), Climate Change 2007, Mitigation. Cambridge: Cambridge University Press Contribution of Working Group III to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change. Levine, M., Ürge-Vorsatz, D., Blok, K., Geng, L., Harvey, D., Lang, S., et al. (2007). Residential and commercial buildings. In B. Metz, O.R. Davidson, P.R. Bosch, R. Dave, & L.A. Meyer (Eds.), Climate Change 2007, Mitigation. Cambridge: Cambridge University Press Contribution of Working Group III to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change.
Zurück zum Zitat Lewis, M. (2004). Integrated design for sustainable buildings. Building for the Future, A Supplement to ASHRAE Journals, 46(9), 22–30. Lewis, M. (2004). Integrated design for sustainable buildings. Building for the Future, A Supplement to ASHRAE Journals, 46(9), 22–30.
Zurück zum Zitat Liu, M., & Claridge, D. E. (1999). Converting dual-duct constant-volume systems to variable-volume systems without retrofitting the terminal boxes. ASHRAE Transactions, 105(Part 1), 66–70. Liu, M., & Claridge, D. E. (1999). Converting dual-duct constant-volume systems to variable-volume systems without retrofitting the terminal boxes. ASHRAE Transactions, 105(Part 1), 66–70.
Zurück zum Zitat Liu, M., Claridge, D. E., & Turner, W. D. (2003). Continuous commissioningSM of building energy systems. Journal of Solar Energy Engineering, 125, 275–281.CrossRef Liu, M., Claridge, D. E., & Turner, W. D. (2003). Continuous commissioningSM of building energy systems. Journal of Solar Energy Engineering, 125, 275–281.CrossRef
Zurück zum Zitat Long, N., Torcellini, P. A., Pless, S. D., & Judkoff, R. (2006). Evaluation of the low-energy design process and energy performance of the Zion National Park Visitor Center. ASHRAE Transactions, 112(Part 1), 321–340. Long, N., Torcellini, P. A., Pless, S. D., & Judkoff, R. (2006). Evaluation of the low-energy design process and energy performance of the Zion National Park Visitor Center. ASHRAE Transactions, 112(Part 1), 321–340.
Zurück zum Zitat McDonell, G. (2003). Displacement ventilation. The Canadian Architect, 48(4), 32–33. McDonell, G. (2003). Displacement ventilation. The Canadian Architect, 48(4), 32–33.
Zurück zum Zitat McDougall, T., Nordmeyer, K., & Klaassen, C. J. (2006). Low-energy building case study: IAMU office and training headquarters. ASHRAE Transactions, 112(Part 1), 312–320. McDougall, T., Nordmeyer, K., & Klaassen, C. J. (2006). Low-energy building case study: IAMU office and training headquarters. ASHRAE Transactions, 112(Part 1), 312–320.
Zurück zum Zitat Mendler, S., & Odell, W. (2000). The HOK Guidebook to Sustainable Design p. 412. New York: Wiley. Mendler, S., & Odell, W. (2000). The HOK Guidebook to Sustainable Design p. 412. New York: Wiley.
Zurück zum Zitat Mumma, S. A. (2001). Ceiling panel cooling system. ASHRAE Journal, 43(11), 28–32. Mumma, S. A. (2001). Ceiling panel cooling system. ASHRAE Journal, 43(11), 28–32.
Zurück zum Zitat Murphy, P. (ed) (2002). Solar Energy Activities in IEA Countries, International Energy Agency, Solar Heating and Cooling Programme, Paris. Available from www.iea-shc.org. Murphy, P. (ed) (2002). Solar Energy Activities in IEA Countries, International Energy Agency, Solar Heating and Cooling Programme, Paris. Available from www.​iea-shc.​org.
Zurück zum Zitat Parker, D. S., Sherwin, J. R., Sonne, J. K., Barkaszi, S. F., Floyd, D. B. & Withers, C. R. (1998). Measured energy savings of a comprehensive retrofit in an existing Florida residence. In Proceedings of the 1998 ACEEE Summer Study on Energy Efficiency in Buildings, 1, 235–251, American Council for an Energy Efficient Economy, Washington. Parker, D. S., Sherwin, J. R., Sonne, J. K., Barkaszi, S. F., Floyd, D. B. & Withers, C. R. (1998). Measured energy savings of a comprehensive retrofit in an existing Florida residence. In Proceedings of the 1998 ACEEE Summer Study on Energy Efficiency in Buildings, 1, 235–251, American Council for an Energy Efficient Economy, Washington.
Zurück zum Zitat Parry, M., Canziani, O., Palutikof, J., van der Linden, P., & Hanson, C. (eds.) (2007). Climate Change 2007, Impacts, Adaptation and Vulnerabilty. Cambridge: Cambridge University Press, Contribution of Working Group II to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change. Parry, M., Canziani, O., Palutikof, J., van der Linden, P., & Hanson, C. (eds.) (2007). Climate Change 2007, Impacts, Adaptation and Vulnerabilty. Cambridge: Cambridge University Press, Contribution of Working Group II to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change.
Zurück zum Zitat Parry, M., Palutikof, J., Hanson, C., & Lowe, J. (2008). Squaring up to reality. Nature Reports Climate Change, 2, 68–70.CrossRef Parry, M., Palutikof, J., Hanson, C., & Lowe, J. (2008). Squaring up to reality. Nature Reports Climate Change, 2, 68–70.CrossRef
Zurück zum Zitat Petersdorff, C., Boermans, T., Joosen, S., Kalacz, I., Jakubowska, B., Scharte, M., et al. (2005a). Cost-effective Climate Protection in the EU Building Stock, Report established by Ecofys for EURIMA, 68 pages. Available from www.eurima.org. Petersdorff, C., Boermans, T., Joosen, S., Kalacz, I., Jakubowska, B., Scharte, M., et al. (2005a). Cost-effective Climate Protection in the EU Building Stock, Report established by Ecofys for EURIMA, 68 pages. Available from www.​eurima.​org.
Zurück zum Zitat Petersdorff, C., Boermans, T., Harnisch, J., Stobbe, O., Ullrich, S., & Wortmann, S. (2005b). Cost-effective Climate Protection in the Building Stock of the New EU Members: Beyond the EU Energy Performance of Buildings Directive, Report established by Ecofys for EURIMA, 78 pages. Available from www.eurima.org. Petersdorff, C., Boermans, T., Harnisch, J., Stobbe, O., Ullrich, S., & Wortmann, S. (2005b). Cost-effective Climate Protection in the Building Stock of the New EU Members: Beyond the EU Energy Performance of Buildings Directive, Report established by Ecofys for EURIMA, 78 pages. Available from www.​eurima.​org.
Zurück zum Zitat Pless, S. D., Torcellini, P. A., & Petersen, J. E. (2006). Energy performance evaluation of a low-energy academic building. ASHRAE Transactions, 112(Part 1), 295–311. Pless, S. D., Torcellini, P. A., & Petersen, J. E. (2006). Energy performance evaluation of a low-energy academic building. ASHRAE Transactions, 112(Part 1), 295–311.
Zurück zum Zitat Poulos, J. (2007). Existing building commissioning. ASHRAE Journal, 49(9), 66–78. Poulos, J. (2007). Existing building commissioning. ASHRAE Journal, 49(9), 66–78.
Zurück zum Zitat Prasad, D., & Snow, M. (2005). Designing with Solar Power: A Source Book for Building Integrated Photovoltaics (BiPV) p. 256. London: James & James. Prasad, D., & Snow, M. (2005). Designing with Solar Power: A Source Book for Building Integrated Photovoltaics (BiPV) p. 256. London: James & James.
Zurück zum Zitat Risbey, J. S. (2008). The new climate discourse, Alarmist or alarming. Global Environmental Change, 18, 26–37.CrossRef Risbey, J. S. (2008). The new climate discourse, Alarmist or alarming. Global Environmental Change, 18, 26–37.CrossRef
Zurück zum Zitat Roth, K. W., Westphalen, D., & Brodrick, J. (2003). Saving energy with building commissioning. ASHRAE Journal, 45(11), 65–66. Roth, K. W., Westphalen, D., & Brodrick, J. (2003). Saving energy with building commissioning. ASHRAE Journal, 45(11), 65–66.
Zurück zum Zitat Roy, A. N., Mahmood, A. R., Baslev-Olesen, O., Lojuntin, S., Tang, C. K., & Kannan, K. S. (2005). Low energy office building in Putrajaya, Malaysia. Case studies and innovations. In Proceedings of Conference on Sustainable Building South Asia, 11–13 April 2005, Malaysia, pp. 223–230. Roy, A. N., Mahmood, A. R., Baslev-Olesen, O., Lojuntin, S., Tang, C. K., & Kannan, K. S. (2005). Low energy office building in Putrajaya, Malaysia. Case studies and innovations. In Proceedings of Conference on Sustainable Building South Asia, 1113 April 2005, Malaysia, pp. 223–230.
Zurück zum Zitat Rudd, A., Kerrigan Jr., P., & Ueno, K. (2004). What will it take to reduce total residential source energy use by up to 60%. Proceedings of the 2004 ACEEE Summer Study on Energy Efficiency in Buildings, 1, 293–305 American Council for an Energy Efficient Economy, Washington. Rudd, A., Kerrigan Jr., P., & Ueno, K. (2004). What will it take to reduce total residential source energy use by up to 60%. Proceedings of the 2004 ACEEE Summer Study on Energy Efficiency in Buildings, 1, 293–305 American Council for an Energy Efficient Economy, Washington.
Zurück zum Zitat Safarzadeh, H., & Bahadori, M. N. (2005). Passive cooling effects of courtyards. Building and Environment, 40, 89–104.CrossRef Safarzadeh, H., & Bahadori, M. N. (2005). Passive cooling effects of courtyards. Building and Environment, 40, 89–104.CrossRef
Zurück zum Zitat Schild, P., & Blom, P. (2002). Pilot Study Report: Jaer School, Nesodden Municipality, Norway, International Energy Agency, Energy Conservation in Buildings and Community Systems, Annex 35. Available from hybvent.civil.auc.dk. Schild, P., & Blom, P. (2002). Pilot Study Report: Jaer School, Nesodden Municipality, Norway, International Energy Agency, Energy Conservation in Buildings and Community Systems, Annex 35. Available from hybvent.civil.auc.dk.
Zurück zum Zitat Schmidt, D. (2002). The Centre for Sustainable Building (ZUB), A Case Study. presented at Sustainable Buildings 2002, Oslo, Norway, International Initiative for a Sustainable Built Environment (www.iisbe.org). Schmidt, D. (2002). The Centre for Sustainable Building (ZUB), A Case Study. presented at Sustainable Buildings 2002, Oslo, Norway, International Initiative for a Sustainable Built Environment (www.​iisbe.​org).
Zurück zum Zitat Schnieders, J., & Hermelink, A. (2006). CEPHEUS results: measurements and occupants’ satisfaction provide evidence for Passive Houses being an option for sustainable building. Energy Policy, 34, 151–171.CrossRef Schnieders, J., & Hermelink, A. (2006). CEPHEUS results: measurements and occupants’ satisfaction provide evidence for Passive Houses being an option for sustainable building. Energy Policy, 34, 151–171.CrossRef
Zurück zum Zitat Sekhar, S. C., & Phua, K. J. (2003). Integrated retrofitting strategy for enhanced energy efficiency in a tropical building. ASHRAE Transactions, 109(Part 1), 202–214. Sekhar, S. C., & Phua, K. J. (2003). Integrated retrofitting strategy for enhanced energy efficiency in a tropical building. ASHRAE Transactions, 109(Part 1), 202–214.
Zurück zum Zitat Short, C. A., & Lomas, K. J. (2007). Exploiting a hybrid environmental design strategy in a US continental climate. Building Research and Information, 35, 119–143.CrossRef Short, C. A., & Lomas, K. J. (2007). Exploiting a hybrid environmental design strategy in a US continental climate. Building Research and Information, 35, 119–143.CrossRef
Zurück zum Zitat Sodec, F. (1999). Economic viability of cooling ceiling systems. Energy and Buildings, 30, 195–201.CrossRef Sodec, F. (1999). Economic viability of cooling ceiling systems. Energy and Buildings, 30, 195–201.CrossRef
Zurück zum Zitat Solaini, G., Dall’o’, G., & Scansani, S. (1998). Simultaneous application of different natural cooling technologies to an experimental building. Renewable Energy, 15, 277–282.CrossRef Solaini, G., Dall’o’, G., & Scansani, S. (1998). Simultaneous application of different natural cooling technologies to an experimental building. Renewable Energy, 15, 277–282.CrossRef
Zurück zum Zitat Solomon, S. et al. (eds.) (2007). Climate Change 2007, The Physical Science Basis. Cambridge: Cambridge University Press, Contribution of Working Group I to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change. Solomon, S. et al. (eds.) (2007). Climate Change 2007, The Physical Science Basis. Cambridge: Cambridge University Press, Contribution of Working Group I to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change.
Zurück zum Zitat Steinbock, J., Eijadi, D., & McDougall, T. (2007). Net zero energy building case study, science house. ASHRAE Transactions, 113(Part 1), 26–35. Steinbock, J., Eijadi, D., & McDougall, T. (2007). Net zero energy building case study, science house. ASHRAE Transactions, 113(Part 1), 26–35.
Zurück zum Zitat Stetiu, C., & Feustel, H. E. (1999). Energy and peak power savings potential of radiant cooling systems in US commercial buildings. Energy and Buildings, 30, 127–138.CrossRef Stetiu, C., & Feustel, H. E. (1999). Energy and peak power savings potential of radiant cooling systems in US commercial buildings. Energy and Buildings, 30, 127–138.CrossRef
Zurück zum Zitat Taylor, P. B., Mathews, E. H., Kleingeld, M., & Taljaard, G. W. (2000). The effect of ceiling insulation on indoor comfort. Building and Environment, 35, 339–346.CrossRef Taylor, P. B., Mathews, E. H., Kleingeld, M., & Taljaard, G. W. (2000). The effect of ceiling insulation on indoor comfort. Building and Environment, 35, 339–346.CrossRef
Zurück zum Zitat Tenorio, R. (2007). Enabling the hybrid use of air conditioning: A prototype on sustainable housing in tropical regions. Building and Environment, 42, 605–613.CrossRef Tenorio, R. (2007). Enabling the hybrid use of air conditioning: A prototype on sustainable housing in tropical regions. Building and Environment, 42, 605–613.CrossRef
Zurück zum Zitat Thanu, N. M., Sawhney, R. L., Khare, R. N., & Buddhi, D. (2001). An experimental study of the thermal performance of an earth-air-pipe system in single pass mode. Solar Energy, 71, 353–364.CrossRef Thanu, N. M., Sawhney, R. L., Khare, R. N., & Buddhi, D. (2001). An experimental study of the thermal performance of an earth-air-pipe system in single pass mode. Solar Energy, 71, 353–364.CrossRef
Zurück zum Zitat Torcellini, P. A., & Crawley, D. B. (2006). Understanding zero-energy buildings. ASHRAE Journal, 48, 62–69. Torcellini, P. A., & Crawley, D. B. (2006). Understanding zero-energy buildings. ASHRAE Journal, 48, 62–69.
Zurück zum Zitat Torcellini, P. A., Deru, M., Griffith, B., Long, N., Pless, S., Judkoff, R., et al. (2004a). Lessons learned from field evaluation of six high-performance buildings. Proceedings of the 2004 ACEEE Summer Study on Energy Efficiency in Buildings, 3, 325–337 American Council for an Energy Efficient Economy, Washington. Torcellini, P. A., Deru, M., Griffith, B., Long, N., Pless, S., Judkoff, R., et al. (2004a). Lessons learned from field evaluation of six high-performance buildings. Proceedings of the 2004 ACEEE Summer Study on Energy Efficiency in Buildings, 3, 325–337 American Council for an Energy Efficient Economy, Washington.
Zurück zum Zitat Torcellini, P. A., Judkoff, R., & Crawley, D. B. (2004b). High-performance buildings: Lessons learned. Buildings for the future (supplement). ASHRAE Journal, 46(9), S4–S11. Torcellini, P. A., Judkoff, R., & Crawley, D. B. (2004b). High-performance buildings: Lessons learned. Buildings for the future (supplement). ASHRAE Journal, 46(9), S4–S11.
Zurück zum Zitat Turner, C. H., & Tovey, N. K. (2006). Case study on the energy performance of the Zuckerman Institute for Connective Environmental Research (ZICER) building. ASHRAE Transactions, 113(Part 2), 320–329. Turner, C. H., & Tovey, N. K. (2006). Case study on the energy performance of the Zuckerman Institute for Connective Environmental Research (ZICER) building. ASHRAE Transactions, 113(Part 2), 320–329.
Zurück zum Zitat Ürge-Vorsatz, D., Novikova, A., Koeppel, S., & Boza-Kiss, B. (2009). Assessment of potentials and costs of carbon dioxide emission mitigation in the buildings sector: insights into the missing elements (in press). Ürge-Vorsatz, D., Novikova, A., Koeppel, S., & Boza-Kiss, B. (2009). Assessment of potentials and costs of carbon dioxide emission mitigation in the buildings sector: insights into the missing elements (in press).
Zurück zum Zitat Voss, K. (2000). Solar Renovation Demonstration Projects, Results and Experience p. 24. London: James & James. Voss, K. (2000). Solar Renovation Demonstration Projects, Results and Experience p. 24. London: James & James.
Zurück zum Zitat Voss, K., Herkel, S., Pfafferott, J., Löhnert, G., & Wagner, A. (2007). Energy efficient office buildings with passive cooling—results and experiences from a research and demonstration programme. Solar Energy, 81, 424–434.CrossRef Voss, K., Herkel, S., Pfafferott, J., Löhnert, G., & Wagner, A. (2007). Energy efficient office buildings with passive cooling—results and experiences from a research and demonstration programme. Solar Energy, 81, 424–434.CrossRef
Zurück zum Zitat Wagner, A., Herkel, S., Löhnert, G., & Voss, K. (2004). Energy efficiency in commercial buildings, Experiences and results from the German funding program SolarBau’. Presented at EuroSolar 2004, Freiburg, and available from www.solarbau.de. Wagner, A., Herkel, S., Löhnert, G., & Voss, K. (2004). Energy efficiency in commercial buildings, Experiences and results from the German funding program SolarBau’. Presented at EuroSolar 2004, Freiburg, and available from www.​solarbau.​de.
Zurück zum Zitat Walker, C. E., Glicksman, L. R., & Norford, L. K. (2007). Tale of two low-energy designs, Comparison of mechanically and naturally ventilated office buildings in temperature climates. ASHRAE Transactions, 113(Part 1), 36–50. Walker, C. E., Glicksman, L. R., & Norford, L. K. (2007). Tale of two low-energy designs, Comparison of mechanically and naturally ventilated office buildings in temperature climates. ASHRAE Transactions, 113(Part 1), 36–50.
Zurück zum Zitat Withers, C. R., & Cummings, J. B. (1998). Ventilation, humidity, and energy impacts of uncontrolled airflow in a light commercial building. ASHRAE Transactions, 104(Part 2), 733–742. Withers, C. R., & Cummings, J. B. (1998). Ventilation, humidity, and energy impacts of uncontrolled airflow in a light commercial building. ASHRAE Transactions, 104(Part 2), 733–742.
Zurück zum Zitat Xu, P., Huang, J., Jin, R., & Yang, G. (2007). Measured energy performance of a US-China demonstration energy-efficient office building. ASHRAE Transactions, 113(Part 1), 56–64. Xu, P., Huang, J., Jin, R., & Yang, G. (2007). Measured energy performance of a US-China demonstration energy-efficient office building. ASHRAE Transactions, 113(Part 1), 56–64.
Zurück zum Zitat Zhen, B., Shanhou, L., & Weifeng, Z. (2005). Energy efficient techniques and simulation of energy consumption for the Shanghai ecological building. In Proceedings 2005 World Sustainable Building Conference, Tokyo, 27–29 September 2005 (SB05Tokyo), pp. 1073–1078. Zhen, B., Shanhou, L., & Weifeng, Z. (2005). Energy efficient techniques and simulation of energy consumption for the Shanghai ecological building. In Proceedings 2005 World Sustainable Building Conference, Tokyo, 2729 September 2005 (SB05Tokyo), pp. 1073–1078.
Metadaten
Titel
Reducing energy use in the buildings sector: measures, costs, and examples
verfasst von
L. D. Danny Harvey
Publikationsdatum
01.05.2009
Verlag
Springer Netherlands
Erschienen in
Energy Efficiency / Ausgabe 2/2009
Print ISSN: 1570-646X
Elektronische ISSN: 1570-6478
DOI
https://doi.org/10.1007/s12053-009-9041-2

Weitere Artikel der Ausgabe 2/2009

Energy Efficiency 2/2009 Zur Ausgabe