Skip to main content
Erschienen in: Fire Technology 4/2015

01.07.2015

Fire Whirl Experimental Facility with No Enclosure of Solid Walls: Design and Validation

verfasst von: Pengfei Wang, Naian Liu, Linhe Zhang, Yueling Bai, Kohyu Satoh

Erschienen in: Fire Technology | Ausgabe 4/2015

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In this work, a fire whirl facility with no enclosure of solid walls was designed, for experimental simulation of fire whirls in open field. Air curtains were used to produce the generating eddy of fire whirl. Tests were conducted to evaluate the capability of the new facility. It was found that there was an optimal tilt angle for the air curtains to produce stable fire whirls. Experiments of fire whirls under different pool diameters showed that the mass loss rate \( \dot{m} \) depended on the circulation \( \varGamma \) by \( \dot{m}\sim \varGamma^{1.18} \) and the dimensionless flame height satisfied \( H^{*} \sim \varGamma^{*0.71} \) (where the asterisks denote dimensionless variables). It was also found that the ratio of the continuous flame height to the whole flame height for different pool diameters was 0.67. The centerline temperatures varied with the normalized height \( Z \) by \( Z^{0.08} \), \( Z^{ - 1.30} \) and \( Z^{ - 2.18} \), respectively in the regions of the continuous flame, intermittent flame and plume. The radiative fraction was calculated to be close to 44%. All these results fit well with literature data, thereby the capability of the new facility for producing stable fire whirls was fully validated. Some potential applications of the new facility were discussed in detail. Especially, instruments such as infrared camera can be used to investigate the flame radiation of fire whirls by the new facility.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Cohen JD (2008) The Wildland-Urban Interface Fire Problem: a consequence of the fire exclusion paradigm. Forest History Today (Fall 2008), pp 20–26 Cohen JD (2008) The Wildland-Urban Interface Fire Problem: a consequence of the fire exclusion paradigm. Forest History Today (Fall 2008), pp 20–26
3.
4.
Zurück zum Zitat Byram GM, Martin RE (1970) The modeling of fire whirlwinds. For Sci 16(4):386–399 Byram GM, Martin RE (1970) The modeling of fire whirlwinds. For Sci 16(4):386–399
5.
Zurück zum Zitat Byram GM, Martin RE (1962) Fire whirlwinds in the laboratory. Fire Control Notes 23(1):13–17 Byram GM, Martin RE (1962) Fire whirlwinds in the laboratory. Fire Control Notes 23(1):13–17
7.
Zurück zum Zitat Satoh K, Yang KT (1996) Experimental observations of swirling fires. ASME Heat Trans Div 335:393–400 Satoh K, Yang KT (1996) Experimental observations of swirling fires. ASME Heat Trans Div 335:393–400
15.
Zurück zum Zitat Zhou R (2014) Applications of the equivalent gap fraction criterion method for fire whirl risk evaluation and prevention in a real fire disaster. Fire Technol 50(1):143–159. doi:10.1007/s10694-012-0277-6 CrossRef Zhou R (2014) Applications of the equivalent gap fraction criterion method for fire whirl risk evaluation and prevention in a real fire disaster. Fire Technol 50(1):143–159. doi:10.​1007/​s10694-012-0277-6 CrossRef
16.
Zurück zum Zitat Zhao CQ, Jiang Y (1998) Dynamics of gas jet. Beijing Institute of Technology Press, Beijing, pp 74–83 (in Chinese) Zhao CQ, Jiang Y (1998) Dynamics of gas jet. Beijing Institute of Technology Press, Beijing, pp 74–83 (in Chinese)
17.
Zurück zum Zitat Liu PQ (2008) The free turbulent jet theory. Beijing University of Aeronautics and Astronautics Press, Beijing, pp 70–88 (in Chinese) Liu PQ (2008) The free turbulent jet theory. Beijing University of Aeronautics and Astronautics Press, Beijing, pp 70–88 (in Chinese)
20.
Zurück zum Zitat Hamins A, Kashiwagi T, Buch RR (1996) Characteristics of pool fire burning. American Society for Testing and Materials Report ASTM STP1284, Indianapolis, p 30 Hamins A, Kashiwagi T, Buch RR (1996) Characteristics of pool fire burning. American Society for Testing and Materials Report ASTM STP1284, Indianapolis, p 30
21.
Zurück zum Zitat Planas-Cuchi E, Chatris JM, Lopez C, Arnaldos J (2003) Determination of flame emissivity in hydrocarbon pool fires using infrared thermography. Fire Technol 39(3):261–273. doi:10.1023/a:1024193515227 CrossRef Planas-Cuchi E, Chatris JM, Lopez C, Arnaldos J (2003) Determination of flame emissivity in hydrocarbon pool fires using infrared thermography. Fire Technol 39(3):261–273. doi:10.​1023/​a:​1024193515227 CrossRef
Metadaten
Titel
Fire Whirl Experimental Facility with No Enclosure of Solid Walls: Design and Validation
verfasst von
Pengfei Wang
Naian Liu
Linhe Zhang
Yueling Bai
Kohyu Satoh
Publikationsdatum
01.07.2015
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 4/2015
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-014-0435-0

Weitere Artikel der Ausgabe 4/2015

Fire Technology 4/2015 Zur Ausgabe