Skip to main content
Erschienen in: Journal of Nondestructive Evaluation 4/2017

01.12.2017

Application of Different X-ray Techniques to Improve In-Service Carbon Fiber Reinforced Rope Inspection

verfasst von: David Schumacher, Kim-Niklas Antin, Uwe Zscherpel, Pedro Vilaça

Erschienen in: Journal of Nondestructive Evaluation | Ausgabe 4/2017

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Carbon fiber reinforced polymer ropes are gaining in significance in the fields of civil engineering and hoisting applications. Thus, methods of non-destructive testing (NDT) need to be developed and evaluated with respect to new challenges and types of defects. Particularly important is the development of in-service testing solutions which allow the integration in global online monitoring systems. Conventional methods like electrical resistivity or strain measurements using optical fibers are already in use. This study investigates the possibility of using various X-ray techniques to increase the reliability and significance of NDT and their applicability to in-service testing. Conventional film radiography is the most common technique; however, even after image enhancement of the digitized film, this technique lacks contrast sensitivity and dynamic range compared to digital detector array (DDA) radiography. The DDA radiography is a highly sensitive method; yet, the limitation is that it delivers 2D images of 3D objects. By the use of co-planar translational laminography the detectability of planar defects is superior to 2D methods due to multiple projection angles. Apart from this, it can be used on-site due to a rather simple setup and robust equipment. In this work two photon counting detectors (PCD) with different sensor materials (Si and CdTe) were used. The results show that the resolution and defect recognition is lower in case of DDA radiography and laminography using PCDs compared to high-resolution computed tomography. However, the DDA radiography and laminography are sensitive enough to both fiber breakage and delaminations and can be significantly advantageous in terms of measurement time and adaptability for on-site monitoring.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
2.
Zurück zum Zitat Rebel, G., Verreet, R., Ridge, I.M.L.: Lightweight ropes for lifting applications. In: OIPEEC Conference (2006) Rebel, G., Verreet, R., Ridge, I.M.L.: Lightweight ropes for lifting applications. In: OIPEEC Conference (2006)
3.
Zurück zum Zitat Mironenko, A., Sukhorukov, V.: Non-destructive testing of steel wire ropes in Russia. Insight Non-Destr. Test. Cond. Monit. 40, 395–397 (1998) Mironenko, A., Sukhorukov, V.: Non-destructive testing of steel wire ropes in Russia. Insight Non-Destr. Test. Cond. Monit. 40, 395–397 (1998)
5.
Zurück zum Zitat Antin, K.-N., Harhanen, L., Bossuyt, S. Damage detection in CFRP components using DIC. In: Adv. Opt. Methods Exp. Mech. vol. 3, pp. 57–62. Springer, New York (2016) Antin, K.-N., Harhanen, L., Bossuyt, S. Damage detection in CFRP components using DIC. In: Adv. Opt. Methods Exp. Mech. vol. 3, pp. 57–62. Springer, New York (2016)
6.
Zurück zum Zitat Otis Elevator Company: Method and apparatus to inspect hoisting ropes. Patent No. US5992574A (1999) Otis Elevator Company: Method and apparatus to inspect hoisting ropes. Patent No. US5992574A (1999)
8.
Zurück zum Zitat Rebel, G., Chaplin, C.R., Groves-Kirkby, C., Ridge, I.M.L.: Condition monitoring techniques for fibre mooring ropes. Insight J. Br. Inst. Non-Destr. Test. 42, 36 (2000) Rebel, G., Chaplin, C.R., Groves-Kirkby, C., Ridge, I.M.L.: Condition monitoring techniques for fibre mooring ropes. Insight J. Br. Inst. Non-Destr. Test. 42, 36 (2000)
9.
Zurück zum Zitat Benmokrane, B., Ali, A.H., Mohamed, H.M., et al.: Durability performance and service life of CFCC tendons exposed to elevated temperature and alkaline environment. J. Compos. Constr. 20, 1–13 (2015). doi:10.1061/(ASCE)CC.1943-5614.0000606 Benmokrane, B., Ali, A.H., Mohamed, H.M., et al.: Durability performance and service life of CFCC tendons exposed to elevated temperature and alkaline environment. J. Compos. Constr. 20, 1–13 (2015). doi:10.​1061/​(ASCE)CC.​1943-5614.​0000606
10.
Zurück zum Zitat ISO 14125:1998 Fibre-reinforced plastic composites—determination of flexural properties ISO 14125:1998 Fibre-reinforced plastic composites—determination of flexural properties
11.
Zurück zum Zitat Pärnänen, T., Vänttinen, A., Kanerva, M., et al.: The effects of debonding on the low-velocity impact response of steel-CFRP fibre metal laminates. Appl. Compos. Mater. 23, 1151–1166 (2016). doi:10.1007/s10443-016-9505-4 CrossRef Pärnänen, T., Vänttinen, A., Kanerva, M., et al.: The effects of debonding on the low-velocity impact response of steel-CFRP fibre metal laminates. Appl. Compos. Mater. 23, 1151–1166 (2016). doi:10.​1007/​s10443-016-9505-4 CrossRef
12.
Zurück zum Zitat Bossi, R.H., Iddings, F.A., Wheeler, G.C.: Radiographic Testing. American Society for Nondestructive Testing, Columbus (2002) Bossi, R.H., Iddings, F.A., Wheeler, G.C.: Radiographic Testing. American Society for Nondestructive Testing, Columbus (2002)
13.
Zurück zum Zitat ISO 5579:2013: Non-destructive testing—radiographic testing of metallic materials using film and X- or gamma rays—basic rules ISO 5579:2013: Non-destructive testing—radiographic testing of metallic materials using film and X- or gamma rays—basic rules
14.
Zurück zum Zitat ISO 11699-1:2008: Non-destructive testing—industrial radiographic film—Part 1: classification of film systems for industrial radiography ISO 11699-1:2008: Non-destructive testing—industrial radiographic film—Part 1: classification of film systems for industrial radiography
15.
Zurück zum Zitat ISO 14096-2:2005: Non-destructive testing—qualification of radiographic film digitisation systems—Part 2: minimum requirements ISO 14096-2:2005: Non-destructive testing—qualification of radiographic film digitisation systems—Part 2: minimum requirements
16.
Zurück zum Zitat Taguchi, K., Iwanczyk, J.S.: Vision 20/20: single photon counting X-ray detectors in medical imaging. Med. Phys. doi:10.1118/1.4820371 (2013) Taguchi, K., Iwanczyk, J.S.: Vision 20/20: single photon counting X-ray detectors in medical imaging. Med. Phys. doi:10.​1118/​1.​4820371 (2013)
17.
Zurück zum Zitat Ullberg, C., Urech, M., Weber, N., et al.: Measurements of a dual-energy fast photon counting CdTe detector with integrated charge sharing correction. Phys Med Imaging (2013). doi:10.1117/12.2007892 Ullberg, C., Urech, M., Weber, N., et al.: Measurements of a dual-energy fast photon counting CdTe detector with integrated charge sharing correction. Phys Med Imaging (2013). doi:10.​1117/​12.​2007892
18.
Zurück zum Zitat Jandejsek, I., Jakubek, J., Jakubek, M., et al.: X-ray inspection of composite materials for aircraft structures using detectors of Medipix type. J. Instrum. 9, C05062 (2014)CrossRef Jandejsek, I., Jakubek, J., Jakubek, M., et al.: X-ray inspection of composite materials for aircraft structures using detectors of Medipix type. J. Instrum. 9, C05062 (2014)CrossRef
19.
Zurück zum Zitat Walter, D., Zscherpel, U., Ewert, U.: Photon counting and energy discriminating X-ray detectors—benefits and applications. In: Proceedings of the 19th World Conference on Non-Destructive Testing Walter, D., Zscherpel, U., Ewert, U.: Photon counting and energy discriminating X-ray detectors—benefits and applications. In: Proceedings of the 19th World Conference on Non-Destructive Testing
20.
Zurück zum Zitat Ewert, U., Redmer, B., Walter, D., et al.: X-ray tomographic in-service inspection of girth welds—the European project TomoWELD. QNDE Proc. doi: 10.1063/1.4914650 (2015) Ewert, U., Redmer, B., Walter, D., et al.: X-ray tomographic in-service inspection of girth welds—the European project TomoWELD. QNDE Proc. doi: 10.​1063/​1.​4914650 (2015)
21.
Zurück zum Zitat Redmer, B., Ewert, U.: TomoCAR—tomographical computer-aided radiology—a new testing method for the visualisation and sizing of defects in circumferential seams. In: Proceedings of the 6th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurized Components Redmer, B., Ewert, U.: TomoCAR—tomographical computer-aided radiology—a new testing method for the visualisation and sizing of defects in circumferential seams. In: Proceedings of the 6th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurized Components
22.
Zurück zum Zitat Bullinger, O., Schnars, U., Schulting, D., et al.: Laminographic inspection of large carbon fibre composite aircraft-structures at airbus. In: Proceedings of the 19th World Conference on Non-Destructive Testing Bullinger, O., Schnars, U., Schulting, D., et al.: Laminographic inspection of large carbon fibre composite aircraft-structures at airbus. In: Proceedings of the 19th World Conference on Non-Destructive Testing
25.
Zurück zum Zitat Rytter, A.: Vibrational based inspection of civil engineering structures. Fract. Dynam. No. 44, vol. R9314 (1993) Rytter, A.: Vibrational based inspection of civil engineering structures. Fract. Dynam. No. 44, vol. R9314 (1993)
Metadaten
Titel
Application of Different X-ray Techniques to Improve In-Service Carbon Fiber Reinforced Rope Inspection
verfasst von
David Schumacher
Kim-Niklas Antin
Uwe Zscherpel
Pedro Vilaça
Publikationsdatum
01.12.2017
Verlag
Springer US
Erschienen in
Journal of Nondestructive Evaluation / Ausgabe 4/2017
Print ISSN: 0195-9298
Elektronische ISSN: 1573-4862
DOI
https://doi.org/10.1007/s10921-017-0441-5

Weitere Artikel der Ausgabe 4/2017

Journal of Nondestructive Evaluation 4/2017 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.