Skip to main content
Erschienen in: Experimental Mechanics 4/2007

01.08.2007

Full 3D Measurement of Strain Field by Scattered Light for Analysis of Structures

verfasst von: A. Germaneau, P. Doumalin, J. C. Dupré

Erschienen in: Experimental Mechanics | Ausgabe 4/2007

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The studies of structures with complex geometry or non-plane loading impose generally taking into account the mechanical volume effects. Mechanical data at the core of materials can be obtained by using special devices, generally from X-ray tomography. In this paper, we present an original volume investigation technique for transparent materials. This technique, easier to implement, does not require any complex device. It is based on scattered light by randomly distributed marks and provides three-dimensional images allowing the use of correlation technique, extended to three dimensions. The accuracy of measurement is evaluated for an imposed rigid body translation and a mechanical homogeneous loading in small and large strains. In conclusion, an example of application is presented concerning a local mechanical loading of compression in which we make a comparison with a finite element simulation.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Chu TC, Ranson WF, Sutton MA, Peters WH (1985) Applications of digital image correlation techniques to experimental mechanics. Exp Mech 25(3):232–244.CrossRef Chu TC, Ranson WF, Sutton MA, Peters WH (1985) Applications of digital image correlation techniques to experimental mechanics. Exp Mech 25(3):232–244.CrossRef
2.
Zurück zum Zitat Bruck HA, McNeill SR, Sutton MA, Peters WH (1989) Digital image correlation using Newton–Raphson method of partial differential correction. Exp Mech 29(2):261–267.CrossRef Bruck HA, McNeill SR, Sutton MA, Peters WH (1989) Digital image correlation using Newton–Raphson method of partial differential correction. Exp Mech 29(2):261–267.CrossRef
3.
Zurück zum Zitat Vendroux G, Knauss WG (1998) Submicron deformation field measurements: Part 2. Improved digital image correlation. Exp Mech 38(2):86–92.CrossRef Vendroux G, Knauss WG (1998) Submicron deformation field measurements: Part 2. Improved digital image correlation. Exp Mech 38(2):86–92.CrossRef
4.
Zurück zum Zitat Bornert M, Doumalin P (2000) Micromechanical applications of digital image correlation techniques. In: Jacquot P, Fournier J (eds) Interferometry in speckle light, theory and applications. Springer, Berlin Heidelberg New York, pp 67–74. Bornert M, Doumalin P (2000) Micromechanical applications of digital image correlation techniques. In: Jacquot P, Fournier J (eds) Interferometry in speckle light, theory and applications. Springer, Berlin Heidelberg New York, pp 67–74.
5.
Zurück zum Zitat Rotinat R, Tié R, Valle V, Dupré JC (2001) Three optical procedures for local large-strain measurement. Strain 37(3):89–98. Rotinat R, Tié R, Valle V, Dupré JC (2001) Three optical procedures for local large-strain measurement. Strain 37(3):89–98.
6.
Zurück zum Zitat Périé J-N, Calloch S, Cluzel C, Hild F (2002) Analysis of a multiaxial test on a C/C composite by using digital image correlation and a damage model. Exp Mech 42(3):318–328. Périé J-N, Calloch S, Cluzel C, Hild F (2002) Analysis of a multiaxial test on a C/C composite by using digital image correlation and a damage model. Exp Mech 42(3):318–328.
7.
Zurück zum Zitat Parsons E, Boyce MC, Parks DM (2004) An experimental investigation of the large-strain tensile behavior of neat and rubber-toughened polycarbonate. Polymer 45:2665–2684.CrossRef Parsons E, Boyce MC, Parks DM (2004) An experimental investigation of the large-strain tensile behavior of neat and rubber-toughened polycarbonate. Polymer 45:2665–2684.CrossRef
8.
Zurück zum Zitat Bretagne N, Valle V, Dupré JC (2005) Developpement of marks tracking technique for strain field and volume variation measurements. NDT E Int 38:290–298.CrossRef Bretagne N, Valle V, Dupré JC (2005) Developpement of marks tracking technique for strain field and volume variation measurements. NDT E Int 38:290–298.CrossRef
9.
Zurück zum Zitat Hild F, Roux S (2006) Digital image correlation: from displacement measurement to identification of elastic properties—a review. Strain 42:69–80.CrossRef Hild F, Roux S (2006) Digital image correlation: from displacement measurement to identification of elastic properties—a review. Strain 42:69–80.CrossRef
10.
Zurück zum Zitat Garcia D, Orteu JJ, Penazzi L (2002) A combined temporal tracking and stereocorrelation technique for accurate measurement of 3D displacements. J Mater Process Technol 125–126:736–742.CrossRef Garcia D, Orteu JJ, Penazzi L (2002) A combined temporal tracking and stereocorrelation technique for accurate measurement of 3D displacements. J Mater Process Technol 125–126:736–742.CrossRef
11.
Zurück zum Zitat Schreier HW, Garcia D, Sutton MA (2004) Advances in light microscope stereo vision. Exp Mech 44(3):278–288.CrossRef Schreier HW, Garcia D, Sutton MA (2004) Advances in light microscope stereo vision. Exp Mech 44(3):278–288.CrossRef
12.
Zurück zum Zitat Feldkamp LA, Goldstein SA, Jesion G, Kleevekoper M (1989) The direct examination of three-dimensional bone architecture in vitro by computed tomography. J Bone Miner Res 4(1):3–11.CrossRef Feldkamp LA, Goldstein SA, Jesion G, Kleevekoper M (1989) The direct examination of three-dimensional bone architecture in vitro by computed tomography. J Bone Miner Res 4(1):3–11.CrossRef
13.
Zurück zum Zitat Phillips DH, Lannutti JJ (1997) Measuring physical density with X-ray computed tomography. NDT E Int 30:339–350.CrossRef Phillips DH, Lannutti JJ (1997) Measuring physical density with X-ray computed tomography. NDT E Int 30:339–350.CrossRef
14.
Zurück zum Zitat Burch SF, Lawrence PF (1992) Recent advances in computerized X-ray tomography using real-time radiography equipment. Br J Non-Destr Test 34(3):125–133. Burch SF, Lawrence PF (1992) Recent advances in computerized X-ray tomography using real-time radiography equipment. Br J Non-Destr Test 34(3):125–133.
15.
Zurück zum Zitat Benouali AH, Froyen L, Delerue JF, Wevers M (2002) Mechanical analysis and microstructural characterization of metal foams. Mater Sci Technol 18(5):489–494.CrossRef Benouali AH, Froyen L, Delerue JF, Wevers M (2002) Mechanical analysis and microstructural characterization of metal foams. Mater Sci Technol 18(5):489–494.CrossRef
16.
Zurück zum Zitat Lambrineas P, Davis JR, Suendermann B, Wells P, Thomson KR, Woodward RL, Egglestone GT, Challis K (1991) X-ray computed tomography examination of inshore mine-hunter hull composite material. NDT E Int 24:207–213.CrossRef Lambrineas P, Davis JR, Suendermann B, Wells P, Thomson KR, Woodward RL, Egglestone GT, Challis K (1991) X-ray computed tomography examination of inshore mine-hunter hull composite material. NDT E Int 24:207–213.CrossRef
17.
Zurück zum Zitat Maire E, Buffière JY, Salvo L, Blandin JJ, Ludwig W, Letang JM (2001) On the application of X-ray microtomography in the field of materials science. Adv Eng Mater 3(8):539–546.CrossRef Maire E, Buffière JY, Salvo L, Blandin JJ, Ludwig W, Letang JM (2001) On the application of X-ray microtomography in the field of materials science. Adv Eng Mater 3(8):539–546.CrossRef
18.
Zurück zum Zitat Babout L, Maire E, Buffière JY, Fougères R (2001) Characterisation by X-ray computed tomography of decohesion, porosity growth and coalescence in model matrix composites. Acta Mater 49:2055–2063.CrossRef Babout L, Maire E, Buffière JY, Fougères R (2001) Characterisation by X-ray computed tomography of decohesion, porosity growth and coalescence in model matrix composites. Acta Mater 49:2055–2063.CrossRef
19.
Zurück zum Zitat Bornert M, Doumalin P, Maire E, Moulinec H (2004) Full 3D investigation of the local strain field in particulate metal matrix composites. Proceedings of 12th international conference on experimental mechanics Bari, Italy, pp 445–446. Bornert M, Doumalin P, Maire E, Moulinec H (2004) Full 3D investigation of the local strain field in particulate metal matrix composites. Proceedings of 12th international conference on experimental mechanics Bari, Italy, pp 445–446.
20.
Zurück zum Zitat Weller R (1941) Three dimensional photoelasticity using scattered light. J Appl Physi 12(8):610–616.CrossRef Weller R (1941) Three dimensional photoelasticity using scattered light. J Appl Physi 12(8):610–616.CrossRef
21.
Zurück zum Zitat Srinath LS (1993) Scattered light photoelasticity. Tata McGraw-Hill, New Delhi. Srinath LS (1993) Scattered light photoelasticity. Tata McGraw-Hill, New Delhi.
22.
Zurück zum Zitat Kihara T, Kubo H, Nagata R (1979) Measurement of 3-D stress distribution by scattered-light method using depolarized incident light. Appl Opt 18(3):321–327.CrossRef Kihara T, Kubo H, Nagata R (1979) Measurement of 3-D stress distribution by scattered-light method using depolarized incident light. Appl Opt 18(3):321–327.CrossRef
23.
Zurück zum Zitat Dupré JC, Lagarde A (1997) Photoelastic analysis of a three-dimensional specimen by optical slicing and digital image processing. Exp Mech 37(4):393–397.CrossRef Dupré JC, Lagarde A (1997) Photoelastic analysis of a three-dimensional specimen by optical slicing and digital image processing. Exp Mech 37(4):393–397.CrossRef
24.
Zurück zum Zitat Zenina A, Dupré JC, Lagarde A (1999) Separation of isochromatic and isoclinic patterns of a slice optically isolated in a 3-D photoelastic medium. Eur J Mech A Solids 18:633–640.MATHCrossRef Zenina A, Dupré JC, Lagarde A (1999) Separation of isochromatic and isoclinic patterns of a slice optically isolated in a 3-D photoelastic medium. Eur J Mech A Solids 18:633–640.MATHCrossRef
25.
Zurück zum Zitat Oi T, Takashi M (2000) An approach to general 3-D stress analysis by multidirectional scattered light technique. In: Lagarde A (ed) IUTAM Symposium on advanced optical methods and applications in solid mechanics. Kluwer, Dordrecht, pp 57–64. Oi T, Takashi M (2000) An approach to general 3-D stress analysis by multidirectional scattered light technique. In: Lagarde A (ed) IUTAM Symposium on advanced optical methods and applications in solid mechanics. Kluwer, Dordrecht, pp 57–64.
26.
Zurück zum Zitat Aben H (1979) Integrated photoelasticity. McGraw-Hill, New York. Aben H (1979) Integrated photoelasticity. McGraw-Hill, New York.
27.
Zurück zum Zitat Bay BK, Smith TS, Fyrhie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39(3):217–226.CrossRef Bay BK, Smith TS, Fyrhie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39(3):217–226.CrossRef
28.
Zurück zum Zitat Smith TS, Bay BK, Rashid MM (2002) Digital volume correlation including rotational degrees of freedom during minimization. Exp Mech 42(3):272–278.CrossRef Smith TS, Bay BK, Rashid MM (2002) Digital volume correlation including rotational degrees of freedom during minimization. Exp Mech 42(3):272–278.CrossRef
29.
Zurück zum Zitat Verhulp E, Rietbergen B, Huiskes R (2004) A three-dimensional digital image correlation technique for strain measurements in microstructures. J Biomech 37:1313–1320.CrossRef Verhulp E, Rietbergen B, Huiskes R (2004) A three-dimensional digital image correlation technique for strain measurements in microstructures. J Biomech 37:1313–1320.CrossRef
30.
Zurück zum Zitat Sutton MA, Mc Neill SR, Jang J, Babai M 1998 Effects of subpixel image restoration on digital correlation error estimates. Opt Eng 27:870–877. Sutton MA, Mc Neill SR, Jang J, Babai M 1998 Effects of subpixel image restoration on digital correlation error estimates. Opt Eng 27:870–877.
31.
Zurück zum Zitat Choi S, Shah SP (1997) Measurement of deformations on concrete subjected to compression using image correlation. Exp Mech 37(3):307–313.CrossRef Choi S, Shah SP (1997) Measurement of deformations on concrete subjected to compression using image correlation. Exp Mech 37(3):307–313.CrossRef
32.
Zurück zum Zitat Horn BKP, Schunck BG (1981) Determining optical flow. Artif Intell 17:185–203.CrossRef Horn BKP, Schunck BG (1981) Determining optical flow. Artif Intell 17:185–203.CrossRef
Metadaten
Titel
Full 3D Measurement of Strain Field by Scattered Light for Analysis of Structures
verfasst von
A. Germaneau
P. Doumalin
J. C. Dupré
Publikationsdatum
01.08.2007
Erschienen in
Experimental Mechanics / Ausgabe 4/2007
Print ISSN: 0014-4851
Elektronische ISSN: 1741-2765
DOI
https://doi.org/10.1007/s11340-006-9029-1

Weitere Artikel der Ausgabe 4/2007

Experimental Mechanics 4/2007 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.