Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 12/2007

01.12.2007 | Technical Note

Electrical characteristics of conductive yarns and textile electrodes for medical applications

verfasst von: Linda Rattfält, Maria Lindén, Peter Hult, Lena Berglin, Per Ask

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 12/2007

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Clothing with conductive textiles for health care applications has in the last decade been of an upcoming research interest. An advantage with the technique is its suitability in distributed and home health care. The present study investigates the electrical properties of conductive yarns and textile electrodes in contact with human skin, thus representing a real ECG-registration situation. The yarn measurements showed a pure resistive characteristic proportional to the length. The electrodes made of pure stainless steel (electrode A) and 20% stainless steel/80% polyester (electrode B) showed acceptable stability of electrode potentials, the stability of A was better than that of B. The electrode made of silver plated copper (electrode C) was less stable. The electrode impedance was lower for electrodes A and B than that for electrode C. From an electrical properties point of view we recommend to use electrodes of type A to be used in intelligent textile medical applications.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Ask P, Öberg PÅ, Ödman S, Tenland T, Skogh M (1979) ECG electrodes, a study of electrical and mechanical long-term properties. Acta Anaesth Scand 23:189–206CrossRef Ask P, Öberg PÅ, Ödman S, Tenland T, Skogh M (1979) ECG electrodes, a study of electrical and mechanical long-term properties. Acta Anaesth Scand 23:189–206CrossRef
2.
Zurück zum Zitat Axisa F, Schmitt PM, Gehin C, Delhomme G, McAdams E, Dittmar A (2005) Flexible technologies and smart clothing for citizen medicine, home healthcare, and disease prevention. IEEE Trans Inf Technol Biomed 9:325–336CrossRef Axisa F, Schmitt PM, Gehin C, Delhomme G, McAdams E, Dittmar A (2005) Flexible technologies and smart clothing for citizen medicine, home healthcare, and disease prevention. IEEE Trans Inf Technol Biomed 9:325–336CrossRef
3.
Zurück zum Zitat Berglin L (2006) Interactive textile structures in Department of Computer Science and Engineering, vol. Licenciate. Gothemburg: Chalmers University of Technology Berglin L (2006) Interactive textile structures in Department of Computer Science and Engineering, vol. Licenciate. Gothemburg: Chalmers University of Technology
4.
Zurück zum Zitat Bonfiglio A, De Rossi D, Kirstein T, Locher IR, Mameli F, Paradiso R, Vozzi G (2005) Organic field effect transistors for textile applications. IEEE Trans Inf Technol Biomed 9:319–324CrossRef Bonfiglio A, De Rossi D, Kirstein T, Locher IR, Mameli F, Paradiso R, Vozzi G (2005) Organic field effect transistors for textile applications. IEEE Trans Inf Technol Biomed 9:319–324CrossRef
5.
Zurück zum Zitat Catrysse M, Puers R, Hertleer C, Van Langenhove L, van Egmond H, Matthys D (2004) Towards the integration of textile sensors in a wireless monitoring suit. Sens Actuators A Phys 114:302–311CrossRef Catrysse M, Puers R, Hertleer C, Van Langenhove L, van Egmond H, Matthys D (2004) Towards the integration of textile sensors in a wireless monitoring suit. Sens Actuators A Phys 114:302–311CrossRef
6.
Zurück zum Zitat Cobbold RSC (1974) Transducers for biomedical measurements: principles and applications. Wiley, New York Cobbold RSC (1974) Transducers for biomedical measurements: principles and applications. Wiley, New York
7.
Zurück zum Zitat Cottet D, Grzyb J, Kirstein T, Troster G (2003) Electrical characterization of textile transmission lines. IEEE Trans Adv Packag 26:182–190CrossRef Cottet D, Grzyb J, Kirstein T, Troster G (2003) Electrical characterization of textile transmission lines. IEEE Trans Adv Packag 26:182–190CrossRef
8.
Zurück zum Zitat Geddes LA (1972) Electrodes and the measurement of bioelectric events. Wiley, New York Geddes LA (1972) Electrodes and the measurement of bioelectric events. Wiley, New York
9.
Zurück zum Zitat Grimnes S (1984) Pathways of ionic flow through human skin in vivo. Acta Derm Venereol 64:93–98 Grimnes S (1984) Pathways of ionic flow through human skin in vivo. Acta Derm Venereol 64:93–98
10.
Zurück zum Zitat Kligfield P, Gettes LS, Bailey JJ, Childers R, Deal BJ, Hancock EW, van Herpen G, Kors JA, Macfarlane P, Mirvis DM, Pahlm O, Rautaharju P, Wagner GS (2007) Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology: a scientific statement from the american heart association electrocardiography and arrhythmias committee, council on clinical cardiology; the american college of cardiology foundation; and the heart rhythm society endorsed by the international society for computerized electrocardiology. Circulation 115:1306–1324 Kligfield P, Gettes LS, Bailey JJ, Childers R, Deal BJ, Hancock EW, van Herpen G, Kors JA, Macfarlane P, Mirvis DM, Pahlm O, Rautaharju P, Wagner GS (2007) Recommendations for the standardization and interpretation of the electrocardiogram: part I: the electrocardiogram and its technology: a scientific statement from the american heart association electrocardiography and arrhythmias committee, council on clinical cardiology; the american college of cardiology foundation; and the heart rhythm society endorsed by the international society for computerized electrocardiology. Circulation 115:1306–1324
11.
Zurück zum Zitat Noury N, Dittmar A, Corroy C, Baghai R, Weber JL, Blanc D, Klefstat F, Blinovska A, Vaysse S, Comet B (2004) A smart cloth for ambulatory telemonitoring of physiological parameters and activity: the VTAMN project Noury N, Dittmar A, Corroy C, Baghai R, Weber JL, Blanc D, Klefstat F, Blinovska A, Vaysse S, Comet B (2004) A smart cloth for ambulatory telemonitoring of physiological parameters and activity: the VTAMN project
12.
Zurück zum Zitat Ottenbacher J, Römer S, Kunze C, Grossman U, Stork W (2004) Integration of a bluetooth based ECG system into clothing. Presented at international symposiom on wearable computers Ottenbacher J, Römer S, Kunze C, Grossman U, Stork W (2004) Integration of a bluetooth based ECG system into clothing. Presented at international symposiom on wearable computers
13.
Zurück zum Zitat Paradiso R, Loriga G, Taccini N (2005) A wearable health care system based on knitted integrated sensors. IEEE Trans Inf Technol Biomed 9:337–344CrossRef Paradiso R, Loriga G, Taccini N (2005) A wearable health care system based on knitted integrated sensors. IEEE Trans Inf Technol Biomed 9:337–344CrossRef
14.
Zurück zum Zitat Park S, Jayaraman S (2003) Enhancing the quality of life through wearable technology. IEEE Eng Med Biol Mag 22:41–8CrossRef Park S, Jayaraman S (2003) Enhancing the quality of life through wearable technology. IEEE Eng Med Biol Mag 22:41–8CrossRef
15.
Zurück zum Zitat Priniotakis G, Westbroek P, Van Langenhove L, Kiekens P (2005) An experimental simulation of human body behavior during sweat production measured at textile electrodes. Int J Cloth Sci Technol 17:232–241CrossRef Priniotakis G, Westbroek P, Van Langenhove L, Kiekens P (2005) An experimental simulation of human body behavior during sweat production measured at textile electrodes. Int J Cloth Sci Technol 17:232–241CrossRef
16.
Zurück zum Zitat Scilingo EP, Gemignani A, Paradiso R, Taccini N, Ghelarducci B, De Rossi D (2005) Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables. IEEE Trans Inf Technol Biomed 9:345–352CrossRef Scilingo EP, Gemignani A, Paradiso R, Taccini N, Ghelarducci B, De Rossi D (2005) Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables. IEEE Trans Inf Technol Biomed 9:345–352CrossRef
17.
Zurück zum Zitat Sergio M, Manaresi N, Tartagni M, Guerrieri R, Canegallo R (2002) A textile based capacitive pressure sensor. Sens Lett 2(2):153–160CrossRef Sergio M, Manaresi N, Tartagni M, Guerrieri R, Canegallo R (2002) A textile based capacitive pressure sensor. Sens Lett 2(2):153–160CrossRef
18.
Zurück zum Zitat Treager RT (1966) Physical functions of the skin. Academic, London Treager RT (1966) Physical functions of the skin. Academic, London
19.
Zurück zum Zitat Wijesiriwardana R, Mitcham K, Dias T (2004) Fiber-meshed transducers based real time wearable physiological information monitoring system. Presented at eighth international symposium on wearable computers Wijesiriwardana R, Mitcham K, Dias T (2004) Fiber-meshed transducers based real time wearable physiological information monitoring system. Presented at eighth international symposium on wearable computers
Metadaten
Titel
Electrical characteristics of conductive yarns and textile electrodes for medical applications
verfasst von
Linda Rattfält
Maria Lindén
Peter Hult
Lena Berglin
Per Ask
Publikationsdatum
01.12.2007
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 12/2007
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-007-0266-y

Weitere Artikel der Ausgabe 12/2007

Medical & Biological Engineering & Computing 12/2007 Zur Ausgabe