Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 6/2018

10.04.2018 | Original Article

A photon recycling approach to the denoising of ultra-low dose X-ray sequences

verfasst von: Sai Gokul Hariharan, Norbert Strobel, Christian Kaethner, Markus Kowarschik, Stefanie Demirci, Shadi Albarqouni, Rebecca Fahrig, Nassir Navab

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 6/2018

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Purpose

Clinical procedures that make use of fluoroscopy may expose patients as well as the clinical staff (throughout their career) to non-negligible doses of radiation. The potential consequences of such exposures fall under two categories, namely stochastic (mostly cancer) and deterministic risks (skin injury). According to the “as low as reasonably achievable” principle, the radiation dose can be lowered only if the necessary image quality can be maintained.

Methods

Our work improves upon the existing patch-based denoising algorithms by utilizing a more sophisticated noise model to exploit non-local self-similarity better and this in turn improves the performance of low-rank approximation. The novelty of the proposed approach lies in its properly designed and parameterized noise model and the elimination of initial estimates. This reduces the computational cost significantly.

Results

The algorithm has been evaluated on 500 clinical images (7 patients, 20 sequences, 3 clinical sites), taken at ultra-low dose levels, i.e. 50% of the standard low dose level, during electrophysiology procedures. An average improvement in the contrast-to-noise ratio (CNR) by a factor of around 3.5 has been found. This is associated with an image quality achieved at around 12 (square of 3.5) times the ultra-low dose level. Qualitative evaluation by X-ray image quality experts suggests that the method produces denoised images that comply with the required image quality criteria.

Conclusion

The results are consistent with the number of patches used, and they demonstrate that it is possible to use motion estimation techniques and “recycle” photons from previous frames to improve the image quality of the current frame. Our results are comparable in terms of CNR to Video Block Matching 3D—a state-of-the-art denoising method. But qualitative analysis by experts confirms that the denoised ultra-low dose X-ray images obtained using our method are more realistic with respect to appearance.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Albarqouni S, Baust M, Conjeti S, Al-Amoudi A, Navab N (2015) Multi-scale graph-based guided filter for de-noising cryo-electron tomographic data. In: BMVC, p 17-1 Albarqouni S, Baust M, Conjeti S, Al-Amoudi A, Navab N (2015) Multi-scale graph-based guided filter for de-noising cryo-electron tomographic data. In: BMVC, p 17-1
2.
Zurück zum Zitat Amiot C, Girard C, Chanussot J, Pescatore J, Desvignes M (2016) Spatio-temporal multiscale denoising of fluoroscopic sequence. IEEE Trans Med Imaging 35(6):1565–1574CrossRefPubMed Amiot C, Girard C, Chanussot J, Pescatore J, Desvignes M (2016) Spatio-temporal multiscale denoising of fluoroscopic sequence. IEEE Trans Med Imaging 35(6):1565–1574CrossRefPubMed
3.
Zurück zum Zitat Boracchi G, Foi A (2008) Multiframe raw-data denoising based on block-matching and 3-d filtering for low-light imaging and stabilization. In: Proceedings of international workshop on local and non-local approximation in image processing, vol 1, pp 277–284 Boracchi G, Foi A (2008) Multiframe raw-data denoising based on block-matching and 3-d filtering for low-light imaging and stabilization. In: Proceedings of international workshop on local and non-local approximation in image processing, vol 1, pp 277–284
4.
Zurück zum Zitat Buades A, Coll B, Morel JM (2005) A non-local algorithm for image denoising. In: Proceedings of IEEE computer society conference on computer vision and pattern recognition, vol 2, pp 60–65. IEEE Buades A, Coll B, Morel JM (2005) A non-local algorithm for image denoising. In: Proceedings of IEEE computer society conference on computer vision and pattern recognition, vol 2, pp 60–65. IEEE
5.
Zurück zum Zitat Cerciello T, Bifulco P, Cesarelli M, Fratini A (2012) A comparison of denoising methods for X-ray fluoroscopic images. Biomed Signal Process Control 7(6):550–559CrossRef Cerciello T, Bifulco P, Cesarelli M, Fratini A (2012) A comparison of denoising methods for X-ray fluoroscopic images. Biomed Signal Process Control 7(6):550–559CrossRef
7.
Zurück zum Zitat Chen Y, Pock T (2017) Trainable nonlinear reaction diffusion: a flexible framework for fast and effective image restoration. IEEE Trans Pattern Anal Mach Intell 39(6):1256–1272CrossRefPubMed Chen Y, Pock T (2017) Trainable nonlinear reaction diffusion: a flexible framework for fast and effective image restoration. IEEE Trans Pattern Anal Mach Intell 39(6):1256–1272CrossRefPubMed
8.
Zurück zum Zitat Coupé P, Hellier P, Kervrann C, Barillot C (2009) Nonlocal means-based speckle filtering for ultrasound images. IEEE Trans Image Process 18(10):2221–2229CrossRefPubMedPubMedCentral Coupé P, Hellier P, Kervrann C, Barillot C (2009) Nonlocal means-based speckle filtering for ultrasound images. IEEE Trans Image Process 18(10):2221–2229CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Dabov K, Foi A, Katkovnik V, Egiazarian K (2009) Bm3d image denoising with shape-adaptive principal component analysis. In: Signal processing with adaptive sparse structured representations Dabov K, Foi A, Katkovnik V, Egiazarian K (2009) Bm3d image denoising with shape-adaptive principal component analysis. In: Signal processing with adaptive sparse structured representations
10.
Zurück zum Zitat Fritz SL, Mirvis SE, Osher Pais S, Roys S (1988) Phantom evaluation of angiographer performance using low frame rate acquisition fluoroscopy. Med Phys 15(4):600–603CrossRefPubMed Fritz SL, Mirvis SE, Osher Pais S, Roys S (1988) Phantom evaluation of angiographer performance using low frame rate acquisition fluoroscopy. Med Phys 15(4):600–603CrossRefPubMed
11.
Zurück zum Zitat Goceri E, Goksel B, Elder JB, Puduvalli VK, Otero JJ, Gurcan MN (2017) Quantitative validation of anti-ptbp1 antibody for diagnostic neuropathology use: image analysis approach. Int J Numer Method Biomed Eng 33:e2862CrossRef Goceri E, Goksel B, Elder JB, Puduvalli VK, Otero JJ, Gurcan MN (2017) Quantitative validation of anti-ptbp1 antibody for diagnostic neuropathology use: image analysis approach. Int J Numer Method Biomed Eng 33:e2862CrossRef
12.
Zurück zum Zitat Goodman T (2010) Ionizing radiation effects and their risk to humans. Image wisely radiation safety in adult medical imaging. Disponível na internet a 22 Goodman T (2010) Ionizing radiation effects and their risk to humans. Image wisely radiation safety in adult medical imaging. Disponível na internet a 22
13.
Zurück zum Zitat Guo Q, Zhang C, Zhang Y, Liu H (2016) An efficient SVD-based method for image denoising. IEEE Trans Circuits Syst Video Technol 26(5):868–880CrossRef Guo Q, Zhang C, Zhang Y, Liu H (2016) An efficient SVD-based method for image denoising. IEEE Trans Circuits Syst Video Technol 26(5):868–880CrossRef
14.
Zurück zum Zitat Kostadin D, Alessandro F, KAREN E (2007) Video denoising by sparse 3d transform-domain collaborative filtering. In: European signal processing conference, vol 149 Kostadin D, Alessandro F, KAREN E (2007) Video denoising by sparse 3d transform-domain collaborative filtering. In: European signal processing conference, vol 149
15.
Zurück zum Zitat Lebrun M, Leclaire A (2012) An implementation and detailed analysis of the K-SVD image denoising algorithm. Image Process On Line 2:96–133CrossRef Lebrun M, Leclaire A (2012) An implementation and detailed analysis of the K-SVD image denoising algorithm. Image Process On Line 2:96–133CrossRef
16.
Zurück zum Zitat Lee MS, Park SW, Lee SY, Kang MG (2017) Motion-adaptive 3d nonlocal means filter based on stochastic distance for low-dose x-ray fluoroscopy. Biomed Signal Process Control 38:74–85CrossRef Lee MS, Park SW, Lee SY, Kang MG (2017) Motion-adaptive 3d nonlocal means filter based on stochastic distance for low-dose x-ray fluoroscopy. Biomed Signal Process Control 38:74–85CrossRef
17.
Zurück zum Zitat Lefkimmiatis S, Papandreou G, Maragos P (2008) Photon-limited image denoising by inference on multiscale models. In: Proceedings international conference on image processing, pp 2332–2335. IEEE Lefkimmiatis S, Papandreou G, Maragos P (2008) Photon-limited image denoising by inference on multiscale models. In: Proceedings international conference on image processing, pp 2332–2335. IEEE
18.
Zurück zum Zitat Luisier F, Blu T, Unser M (2010) Sure-let for orthonormal wavelet-domain video denoising. IEEE Trans Circuits Syst Video Technol 20(6):913–919CrossRef Luisier F, Blu T, Unser M (2010) Sure-let for orthonormal wavelet-domain video denoising. IEEE Trans Circuits Syst Video Technol 20(6):913–919CrossRef
19.
Zurück zum Zitat Makitalo M, Foi A (2013) Optimal inversion of the generalized Anscombe transformation for Poisson-Gaussian noise. IEEE Trans Image Process 22(1):91–103CrossRefPubMed Makitalo M, Foi A (2013) Optimal inversion of the generalized Anscombe transformation for Poisson-Gaussian noise. IEEE Trans Image Process 22(1):91–103CrossRefPubMed
20.
Zurück zum Zitat Parker DL, Clayton PD, Tarbox LR, Von Behren PL (1983) Optimal dose utilization with variable X-ray intensity in digital radiography. In: Application of optical instrumentation in medicine XI, pp 102–110. International Society for Optics and Photonics Parker DL, Clayton PD, Tarbox LR, Von Behren PL (1983) Optimal dose utilization with variable X-ray intensity in digital radiography. In: Application of optical instrumentation in medicine XI, pp 102–110. International Society for Optics and Photonics
21.
Zurück zum Zitat Schmidt U, Roth S (2014) Shrinkage fields for effective image restoration. In: Proceedings of IEEE computer society conference on computer vision and pattern recognition, pp 2774–2781 Schmidt U, Roth S (2014) Shrinkage fields for effective image restoration. In: Proceedings of IEEE computer society conference on computer vision and pattern recognition, pp 2774–2781
22.
Zurück zum Zitat Wagner M, Yang P, Schafer S, Strother C, Mistretta C (2015) Noise reduction for curve-linear structures in real time fluoroscopy applications using directional binary masks. Med Phys 42(8):4645–4653CrossRefPubMedPubMedCentral Wagner M, Yang P, Schafer S, Strother C, Mistretta C (2015) Noise reduction for curve-linear structures in real time fluoroscopy applications using directional binary masks. Med Phys 42(8):4645–4653CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Weickert J, Scharr H (2002) A scheme for coherence-enhancing diffusion filtering with optimized rotation invariance. J Vis Commun Image Represent 13(1–2):103–118CrossRef Weickert J, Scharr H (2002) A scheme for coherence-enhancing diffusion filtering with optimized rotation invariance. J Vis Commun Image Represent 13(1–2):103–118CrossRef
24.
Zurück zum Zitat Yang K, Huang SY, Packard NJ, Boone JM (2010) Noise variance analysis using a flat panel X-ray detector: a method for additive noise assessment with application to breast ct applications. Med Phys 37(7):3527–3537CrossRefPubMedPubMedCentral Yang K, Huang SY, Packard NJ, Boone JM (2010) Noise variance analysis using a flat panel X-ray detector: a method for additive noise assessment with application to breast ct applications. Med Phys 37(7):3527–3537CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Zhang K, Zuo W, Chen Y, Meng D, Zhang L (2017) Beyond a Gaussian denoiser: residual learning of deep cnn for image denoising. IEEE Trans Image Process 26:3142–3155CrossRefPubMed Zhang K, Zuo W, Chen Y, Meng D, Zhang L (2017) Beyond a Gaussian denoiser: residual learning of deep cnn for image denoising. IEEE Trans Image Process 26:3142–3155CrossRefPubMed
Metadaten
Titel
A photon recycling approach to the denoising of ultra-low dose X-ray sequences
verfasst von
Sai Gokul Hariharan
Norbert Strobel
Christian Kaethner
Markus Kowarschik
Stefanie Demirci
Shadi Albarqouni
Rebecca Fahrig
Nassir Navab
Publikationsdatum
10.04.2018
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 6/2018
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-018-1746-2

Weitere Artikel der Ausgabe 6/2018

International Journal of Computer Assisted Radiology and Surgery 6/2018 Zur Ausgabe