Skip to main content

2016 | OriginalPaper | Buchkapitel

LUT-QNE: Look-Up-Table Quantum Noise Equalization in Digital Mammograms

verfasst von : Alessandro Bria, Claudio Marrocco, Jan-Jurre Mordang, Nico Karssemeijer, Mario Molinara, Francesco Tortorella

Erschienen in: Breast Imaging

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Quantum noise is a signal-dependent, Poisson-distributed noise and the dominant noise source in digital mammography. Quantum noise removal or equalization has been shown to be an important step in the automatic detection of microcalcifications. However, it is often limited by the difficulty of robustly estimating the noise parameters on the images. In this study, a nonparametric image intensity transformation method that equalizes quantum noise in digital mammograms is described. A simple Look-Up-Table for Quantum Noise Equalization (LUT-QNE) is determined based on the assumption that noise properties do not vary significantly across the images. This method was evaluated on a dataset of 252 raw digital mammograms by comparing noise statistics before and after applying LUT-QNE. Performance was also tested as a preprocessing step in two microcalcification detection schemes. Results show that the proposed method statistically significantly improves microcalcification detection performance.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Ekpo, E.U., Egbe, N.O., Egom, A.E., McEntee, M.F.: Mammographic breast density: comparison across women with conclusive and inconclusive mammography reports. J. Med. Imaging Radiat. Sci. 1, 55–59 (2015) Ekpo, E.U., Egbe, N.O., Egom, A.E., McEntee, M.F.: Mammographic breast density: comparison across women with conclusive and inconclusive mammography reports. J. Med. Imaging Radiat. Sci. 1, 55–59 (2015)
2.
Zurück zum Zitat Eadie, L.H., Taylor, P., Gibson, A.P.: A systematic review of computer-assisted diagnosis in diagnostic cancer imaging. Eur. J. Radiol. 81(1), e70–e76 (2012)CrossRef Eadie, L.H., Taylor, P., Gibson, A.P.: A systematic review of computer-assisted diagnosis in diagnostic cancer imaging. Eur. J. Radiol. 81(1), e70–e76 (2012)CrossRef
3.
Zurück zum Zitat Romualdo, L., Vieira, M., Schiabel, H., Mascarenhas, N., Borges, L.: Mammographic image denoising and enhancement using the anscombe transformation, adaptive wiener filtering, and the modulation transfer function. J. Digit. Imaging 26(2), 183–197 (2013)CrossRef Romualdo, L., Vieira, M., Schiabel, H., Mascarenhas, N., Borges, L.: Mammographic image denoising and enhancement using the anscombe transformation, adaptive wiener filtering, and the modulation transfer function. J. Digit. Imaging 26(2), 183–197 (2013)CrossRef
4.
Zurück zum Zitat McLoughlin, K.J., Bones, P.J., Karssemeijer, N.: Noise equalization for detection of microcalcification clusters in direct digital mammogram images. IEEE Trans. Med. Imaging 23(3), 313–320 (2004)CrossRef McLoughlin, K.J., Bones, P.J., Karssemeijer, N.: Noise equalization for detection of microcalcification clusters in direct digital mammogram images. IEEE Trans. Med. Imaging 23(3), 313–320 (2004)CrossRef
5.
Zurück zum Zitat Veldkamp, W.J.H., Karssemeijer, N.: Normalization of local contrast in mammograms. IEEE Trans. Med. Imaging 19(7), 731–738 (2000)CrossRef Veldkamp, W.J.H., Karssemeijer, N.: Normalization of local contrast in mammograms. IEEE Trans. Med. Imaging 19(7), 731–738 (2000)CrossRef
6.
Zurück zum Zitat van Schie, G., Karssemeijer, N.: Detection of microcalcifications using a nonuniform noise model. In: Krupinski, E.A. (ed.) IWDM 2008. LNCS, vol. 5116, pp. 378–384. Springer, Heidelberg (2008)CrossRef van Schie, G., Karssemeijer, N.: Detection of microcalcifications using a nonuniform noise model. In: Krupinski, E.A. (ed.) IWDM 2008. LNCS, vol. 5116, pp. 378–384. Springer, Heidelberg (2008)CrossRef
7.
Zurück zum Zitat Tromans, C.E., Cocker, M.R., Brady, S.M.: Quantification and normalization of x-ray mammograms. Phys. Med. Biol. 57(20), 6519 (2012)CrossRef Tromans, C.E., Cocker, M.R., Brady, S.M.: Quantification and normalization of x-ray mammograms. Phys. Med. Biol. 57(20), 6519 (2012)CrossRef
8.
Zurück zum Zitat Bria, A., Marrocco, C., Molinara, M., Tortorella, F.: Detecting clusters of microcalcifications with a cascade-based approach. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds.) IWDM 2012. LNCS, vol. 7361, pp. 111–118. Springer, Heidelberg (2012)CrossRef Bria, A., Marrocco, C., Molinara, M., Tortorella, F.: Detecting clusters of microcalcifications with a cascade-based approach. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds.) IWDM 2012. LNCS, vol. 7361, pp. 111–118. Springer, Heidelberg (2012)CrossRef
9.
Zurück zum Zitat Dengler, J., Behrens, S., Desaga, J.: Segmentation of microcalcifications in mammograms. IEEE Trans. Med. Imaging 12, 634–642 (1993)CrossRef Dengler, J., Behrens, S., Desaga, J.: Segmentation of microcalcifications in mammograms. IEEE Trans. Med. Imaging 12, 634–642 (1993)CrossRef
10.
Zurück zum Zitat El Naqa, I., Yang, W.M.N., Galatsanos, Y.N.P., Nishikawa, R.M.: A support vector machine approach for detection of microcalcifications. IEEE Trans. Med. Imaging 21(12), 1552–1563 (2002)CrossRef El Naqa, I., Yang, W.M.N., Galatsanos, Y.N.P., Nishikawa, R.M.: A support vector machine approach for detection of microcalcifications. IEEE Trans. Med. Imaging 21(12), 1552–1563 (2002)CrossRef
11.
Zurück zum Zitat Yousef, W.A.: Assessing classifiers in terms of the partial area under the ROC curve. Comput. Stat. Data Anal. 64, 51–70 (2013)MathSciNetCrossRef Yousef, W.A.: Assessing classifiers in terms of the partial area under the ROC curve. Comput. Stat. Data Anal. 64, 51–70 (2013)MathSciNetCrossRef
12.
Zurück zum Zitat Bria, A., Karssemeijer, N., Tortorella, F.: Learning from unbalanced data: a cascade-based approach for detecting clustered microcalcifications. Med. Image Anal. 18(2), 241–252 (2014)CrossRef Bria, A., Karssemeijer, N., Tortorella, F.: Learning from unbalanced data: a cascade-based approach for detecting clustered microcalcifications. Med. Image Anal. 18(2), 241–252 (2014)CrossRef
Metadaten
Titel
LUT-QNE: Look-Up-Table Quantum Noise Equalization in Digital Mammograms
verfasst von
Alessandro Bria
Claudio Marrocco
Jan-Jurre Mordang
Nico Karssemeijer
Mario Molinara
Francesco Tortorella
Copyright-Jahr
2016
DOI
https://doi.org/10.1007/978-3-319-41546-8_4

Premium Partner