Abstract

Dexterity is commonly defined by the quality of fine, voluntary movements used to manipulate objects during a specific task involving the movement of wrist, hands, arm, and fingers. Dexterity assessment kits are used to determine a person’s skilled task abilities through performance parameters such as speed, accuracy, and precision. This study proposes that one parameter that is as critical as the traditionally measured parameters is finger strength which could be measured as the amount of force or effort that a human hand exerts during object manipulation through fingers. In this paper, a detailed literature review was conducted of the traditional dexterity assessment methods and their kits used in the past. Thereafter, a novel dexterity kit has been proposed which incorporates measurement of finger strength data in addition to the traditional dexterity parameters during hand dexterity assessment. An experiment suggested that a significantly greater finger force is required for peg manipulation in the new test kit than in the traditional one.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Backman C, Gibson SCD, Parsons J (1992) Assessment of hand function: the relationship between pegboard dexterity and applied dexterity. Can J Occup Ther 59(4):208–213CrossRef Backman C, Gibson SCD, Parsons J (1992) Assessment of hand function: the relationship between pegboard dexterity and applied dexterity. Can J Occup Ther 59(4):208–213CrossRef
2.
Zurück zum Zitat Williams ME, Hadler NM, Earp JAL (1982) Manual ability as a marker of dependency in geriatric women. J Chronic Dis 35(2):115–122 Williams ME, Hadler NM, Earp JAL (1982) Manual ability as a marker of dependency in geriatric women. J Chronic Dis 35(2):115–122
3.
Zurück zum Zitat Gallus J, Mathiowetz Vl (2003) Test–retest reliability of the Purdue Pegboard for persons with multiple sclerosis. Am J Occupational Ther 57(1):108–111CrossRef Gallus J, Mathiowetz Vl (2003) Test–retest reliability of the Purdue Pegboard for persons with multiple sclerosis. Am J Occupational Ther 57(1):108–111CrossRef
4.
Zurück zum Zitat Merker B, Podell K (2011) Grooved pegboard test. In: Encyclopedia of clinical neuropsychology. Springer, New York, pp 1176–1178 Merker B, Podell K (2011) Grooved pegboard test. In: Encyclopedia of clinical neuropsychology. Springer, New York, pp 1176–1178
5.
Zurück zum Zitat Desrosiers J, Rochette A, Hébert R, Bravo G (1997) The Minnesota manual dexterity test: reliability, validity and reference values studies with healthy elderly people. Can J Occupational Ther 64(5):270–276CrossRef Desrosiers J, Rochette A, Hébert R, Bravo G (1997) The Minnesota manual dexterity test: reliability, validity and reference values studies with healthy elderly people. Can J Occupational Ther 64(5):270–276CrossRef
6.
Zurück zum Zitat Aaron DH, Jansen CWS (2003) Development of the Functional Dexterity Test (FDT): construction, validity, reliability, and normative data. J Hand Ther 16(1):12–21 Aaron DH, Jansen CWS (2003) Development of the Functional Dexterity Test (FDT): construction, validity, reliability, and normative data. J Hand Ther 16(1):12–21
7.
Zurück zum Zitat Mathiowetz V, Volland G, Kashman N, Weber K (1985) Adult norms for the box and block Test of manual dexterity. Am J Occupational Ther 39(6):386–391CrossRef Mathiowetz V, Volland G, Kashman N, Weber K (1985) Adult norms for the box and block Test of manual dexterity. Am J Occupational Ther 39(6):386–391CrossRef
8.
Zurück zum Zitat Berger MA, Krul AJ, Daanen HA (2009) Task specificity of finger dexterity tests. Appl Ergon 40(1):145–147 Berger MA, Krul AJ, Daanen HA (2009) Task specificity of finger dexterity tests. Appl Ergon 40(1):145–147
9.
Zurück zum Zitat Shimoyama I, Ninchoji T, Uemura K (1990) The finger-tapping test: a quantitative analysis. Arch Neurol 47(6):681–684CrossRef Shimoyama I, Ninchoji T, Uemura K (1990) The finger-tapping test: a quantitative analysis. Arch Neurol 47(6):681–684CrossRef
10.
Zurück zum Zitat Moberg E (1958) Objective methods for determining the functional value of sensibility in the hand. J bone Joint Surg. Br Volume 40(3):454–476 Moberg E (1958) Objective methods for determining the functional value of sensibility in the hand. J bone Joint Surg. Br Volume 40(3):454–476
11.
Zurück zum Zitat Jebsen RH, Taylor NEAL, Trieschmann RB, Trotter MJ, Howard LA (1969) An objective and standardized test of hand function. Arch Phys Med Rehabilitation 50(6):311–319 Jebsen RH, Taylor NEAL, Trieschmann RB, Trotter MJ, Howard LA (1969) An objective and standardized test of hand function. Arch Phys Med Rehabilitation 50(6):311–319
12.
Zurück zum Zitat Tiffin J (1968) Purdue Pegboard examiner manual. Science Research Associates Inc., Chicago, Illinois Tiffin J (1968) Purdue Pegboard examiner manual. Science Research Associates Inc., Chicago, Illinois
13.
Zurück zum Zitat Fleishman EA (1953) Testing for psychomotor abilities by means of apparatus tests. Psychol Bull 50(4):241 Fleishman EA (1953) Testing for psychomotor abilities by means of apparatus tests. Psychol Bull 50(4):241
14.
Zurück zum Zitat Duff SV, Aaron DH, Gogola GR, Valero-Cuevas FJ (2015) Innovative evaluation of dexterity in pediatrics. J Hand Ther 28(2):144–150CrossRef Duff SV, Aaron DH, Gogola GR, Valero-Cuevas FJ (2015) Innovative evaluation of dexterity in pediatrics. J Hand Ther 28(2):144–150CrossRef
15.
Zurück zum Zitat Lee-Valkov PM, Aaron DH, Eladoumikdachi F, Thornby J, Netscher DT (2003) Measuring normal hand dexterity values in normal 3-, 4-, and 5-year-old children and their relationship with grip and pinch strength. J Hand Ther 16(1):22–28CrossRef Lee-Valkov PM, Aaron DH, Eladoumikdachi F, Thornby J, Netscher DT (2003) Measuring normal hand dexterity values in normal 3-, 4-, and 5-year-old children and their relationship with grip and pinch strength. J Hand Ther 16(1):22–28CrossRef
16.
Zurück zum Zitat Manual, SolidWorks–Users (2009) Dassault Systems Solid Works Corporation. SolidWorks Corp,Concord Manual, SolidWorks–Users (2009) Dassault Systems Solid Works Corporation. SolidWorks Corp,Concord
17.
Zurück zum Zitat Sharp ED (1962) Maximum torque exertable on knobs of various sizes and rim surfaces. No. MRL-TDR-62-17. Air Force Aerospace Medical Research Lab Wright-Patterson AFB OH Sharp ED (1962) Maximum torque exertable on knobs of various sizes and rim surfaces. No. MRL-TDR-62-17. Air Force Aerospace Medical Research Lab Wright-Patterson AFB OH
18.
Zurück zum Zitat Amis AA (1987) Variation of finger forces in maximal isometric grasp tests on a range of cylinder diameters. J Biomed Eng 9(4):313–320CrossRef Amis AA (1987) Variation of finger forces in maximal isometric grasp tests on a range of cylinder diameters. J Biomed Eng 9(4):313–320CrossRef
19.
Zurück zum Zitat Kong Y-K, Lowe BD (2005) Optimal cylindrical handle diameter for grip force tasks. Int J Ind Ergon 35(6):495–507CrossRef Kong Y-K, Lowe BD (2005) Optimal cylindrical handle diameter for grip force tasks. Int J Ind Ergon 35(6):495–507CrossRef
20.
Zurück zum Zitat Bell A, Walton K, Yoxall A (2017) Measure for measure: pack performance versus human dexterity and grip strength. Packag Technol Sci 30(4):117–126CrossRef Bell A, Walton K, Yoxall A (2017) Measure for measure: pack performance versus human dexterity and grip strength. Packag Technol Sci 30(4):117–126CrossRef
21.
Zurück zum Zitat Mathiowetz V, Weber K, Kashman N, Volland G (2016) Adult norms for the Nine Hole Peg Test of finger dexterity. Occup Ther J Res 5(1):24–38CrossRef Mathiowetz V, Weber K, Kashman N, Volland G (2016) Adult norms for the Nine Hole Peg Test of finger dexterity. Occup Ther J Res 5(1):24–38CrossRef
Metadaten
Titel
Novel Dexterity Kit Concept Based on a Review of Hand Dexterity Literature
verfasst von
Gaurav Saraf
Dhananjay Singh Bisht
Copyright-Jahr
2020
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-15-2696-1_8

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.