Skip to main content
Erschienen in: Health and Technology 6/2020

04.10.2020 | Original Paper

Performance evaluation of a new mobile air-treatment technology at-rest and under normal work conditions in a conventional hematology room

verfasst von: Anne Pouvaret, Emmanuelle Tavernier, Jérôme Cornillon, Elisabeth Daguenet, Hélène Raberin, Florence Grattard, Philippe Berthelot, Denis Guyotat

Erschienen in: Health and Technology | Ausgabe 6/2020

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Invasive fungal infections incidence in patients with hematological malignancies is increasing. Air treatment remains an essential preventive measure. Guidelines state that high-risk patients should be housed in units equipped with High-Efficiency Particulate Air filtration. Mobile air-treatment devices may be considered as alternatives or as a complement to the ventilation system. We assessed the decontamination performances of a new mobile air-treatment device in a conventional hematology room. This device connected or not to a plenum combining Ultra-Low Particulate Air filtration and non-thermal catalysis process has been evaluated with or without healthcare activities (one sampling at-rest and triplicate samplings in activity). Environmental particulate, airborne and surface fungal and total mesophilic flora (TMF) samplings were performed with a total of 1800 min of particles counting, 144 air and 240 surface samplings. At-rest, both devices achieved a 2-log decrease of airborne particles, ISO 4 being the maximal particle class reached under the plenum. Whatever the healthcare activities and the location in the room, ISO 7 was the maximal particle class reached. TMF and fungal air contamination were lower during healthcare activities when the air portable cleaners were running. The bed was the area the least contaminated in the room. No differences were observed for surface contamination. This work provides arguments of the efficacy of a new mobile air-treatment device to decrease particle counts and airborne bioburden in real-life conditions. Studies have yet to be conducted to document the impact of these devices on the risk of invasive aspergillosis in immunocompromised patients.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Spagnolo AM, Ottria G, Amicizia D, Perdelli F, Cristina ML. Operating theatre quality and prevention of surgical site infections. J Prev Med Hyg. 2013;54:131–7. Spagnolo AM, Ottria G, Amicizia D, Perdelli F, Cristina ML. Operating theatre quality and prevention of surgical site infections. J Prev Med Hyg. 2013;54:131–7.
3.
Zurück zum Zitat Bitar D, Lortholary O, Le Strat Y, Nicolau J, Coignard B, Tattevin P, et al. Population-based analysis of invasive fungal infections, France, 2001-2010. Emerg Infect Dis. 2014;20:1149–55.CrossRef Bitar D, Lortholary O, Le Strat Y, Nicolau J, Coignard B, Tattevin P, et al. Population-based analysis of invasive fungal infections, France, 2001-2010. Emerg Infect Dis. 2014;20:1149–55.CrossRef
4.
6.
Zurück zum Zitat Zahar J-R, Jolivet S, Adam H, Dananché C, Lizon J, Alfandari S, et al. French recommendations on control measures to reduce the infectious risk in immunocompromised patients. J Mycol Med. 2017;27:449–56.CrossRef Zahar J-R, Jolivet S, Adam H, Dananché C, Lizon J, Alfandari S, et al. French recommendations on control measures to reduce the infectious risk in immunocompromised patients. J Mycol Med. 2017;27:449–56.CrossRef
7.
Zurück zum Zitat Vonberg R-P, Gastmeier P. Nosocomial aspergillosis in outbreak settings. J Hosp Infect. 2006;63:246–54.CrossRef Vonberg R-P, Gastmeier P. Nosocomial aspergillosis in outbreak settings. J Hosp Infect. 2006;63:246–54.CrossRef
8.
Zurück zum Zitat Kanamori H, Rutala WA, Sickbert-Bennett EE, Weber DJ. Review of fungal outbreaks and infection prevention in healthcare settings during construction and renovation. Clin Infect Dis. 2015;61:433–44.CrossRef Kanamori H, Rutala WA, Sickbert-Bennett EE, Weber DJ. Review of fungal outbreaks and infection prevention in healthcare settings during construction and renovation. Clin Infect Dis. 2015;61:433–44.CrossRef
9.
Zurück zum Zitat Sixt N, Dalle F, Lafon I, Aho S, Couillault G, Valot S, et al. Reduced fungal contamination of the indoor environment with the Plasmair system (Airinspace). J Hosp Infect. 2007;65:156–62.CrossRef Sixt N, Dalle F, Lafon I, Aho S, Couillault G, Valot S, et al. Reduced fungal contamination of the indoor environment with the Plasmair system (Airinspace). J Hosp Infect. 2007;65:156–62.CrossRef
10.
Zurück zum Zitat Sautour M, Sixt N, Dalle F, L’ollivier C, Calinon C, Fourquenet V, et al. Prospective survey of indoor fungal contamination in hospital during a period of building construction. J Hosp Infect. 2007;67:367–73.CrossRef Sautour M, Sixt N, Dalle F, L’ollivier C, Calinon C, Fourquenet V, et al. Prospective survey of indoor fungal contamination in hospital during a period of building construction. J Hosp Infect. 2007;67:367–73.CrossRef
12.
Zurück zum Zitat Fournel I, Tiv M, Hua C, Soulias M, Astruc K, Aho LS. Randomisation and sample size for clinical audit on infection control. J Hosp Infect. 2010;76:292–5.CrossRef Fournel I, Tiv M, Hua C, Soulias M, Astruc K, Aho LS. Randomisation and sample size for clinical audit on infection control. J Hosp Infect. 2010;76:292–5.CrossRef
15.
Zurück zum Zitat Poirot J-L, Gangneux J-P, Fischer A, Malbernard M, Challier S, Laudinet N, et al. Evaluation of a new mobile system for protecting immune-suppressed patients against airborne contamination. Am J Infect Control. 2007;35:460–6.CrossRef Poirot J-L, Gangneux J-P, Fischer A, Malbernard M, Challier S, Laudinet N, et al. Evaluation of a new mobile system for protecting immune-suppressed patients against airborne contamination. Am J Infect Control. 2007;35:460–6.CrossRef
16.
Zurück zum Zitat Kiyosuke M, Morokuma Y, Kadowaki M, Kibe Y, Yamashita Y, Yamasaki M, et al. Particle monitoring and effectiveness of large-scale cleaning in a bone marrow transplantation unit. Japan J Infect Prev Control. 2013;28:334–41.CrossRef Kiyosuke M, Morokuma Y, Kadowaki M, Kibe Y, Yamashita Y, Yamasaki M, et al. Particle monitoring and effectiveness of large-scale cleaning in a bone marrow transplantation unit. Japan J Infect Prev Control. 2013;28:334–41.CrossRef
17.
Zurück zum Zitat Armadans-Gil L, Rodríguez-Garrido V, Campins-Martí M, Gil-Cuesta J, Vaqué-Rafart J. Particle counting and microbiological air sampling: results of the simultaneous use of both procedures in different types of hospital rooms. Enferm Infecc Microbiol Clin. 2013;31:217–21.CrossRef Armadans-Gil L, Rodríguez-Garrido V, Campins-Martí M, Gil-Cuesta J, Vaqué-Rafart J. Particle counting and microbiological air sampling: results of the simultaneous use of both procedures in different types of hospital rooms. Enferm Infecc Microbiol Clin. 2013;31:217–21.CrossRef
18.
Zurück zum Zitat Picot-Guéraud R, Khouri C, Brenier-Pinchart M-P, Saviuc P, Fares A, Sellon T, et al. En-suite bathrooms in protected haematology wards: a source of filamentous fungal contamination? J Hosp Infect. 2015;91:244–9.CrossRef Picot-Guéraud R, Khouri C, Brenier-Pinchart M-P, Saviuc P, Fares A, Sellon T, et al. En-suite bathrooms in protected haematology wards: a source of filamentous fungal contamination? J Hosp Infect. 2015;91:244–9.CrossRef
19.
Zurück zum Zitat Gordon O, Berchtold M, Staerk A, Roesti D. Comparison of different incubation conditions for microbiological environmental monitoring. PDA J Pharm Sci Technol. 2014;68:394–406.CrossRef Gordon O, Berchtold M, Staerk A, Roesti D. Comparison of different incubation conditions for microbiological environmental monitoring. PDA J Pharm Sci Technol. 2014;68:394–406.CrossRef
20.
Zurück zum Zitat Rhame FS, Streifel AJ, Kersey JH, McGlave PB. Extrinsic risk factors for pneumonia in the patient at high risk of infection. Am J Med. 1984;76:42–52.CrossRef Rhame FS, Streifel AJ, Kersey JH, McGlave PB. Extrinsic risk factors for pneumonia in the patient at high risk of infection. Am J Med. 1984;76:42–52.CrossRef
21.
Zurück zum Zitat Opal SM, Asp AA, Cannady PB, Morse PL, Burton LJ, Hammer PG. Efficacy of infection control measures during a nosocomial outbreak of disseminated aspergillosis associated with hospital construction. J Infect Dis. 1986;153:634–7.CrossRef Opal SM, Asp AA, Cannady PB, Morse PL, Burton LJ, Hammer PG. Efficacy of infection control measures during a nosocomial outbreak of disseminated aspergillosis associated with hospital construction. J Infect Dis. 1986;153:634–7.CrossRef
22.
Zurück zum Zitat Loo VG, Bertrand C, Dixon C, Vityé D, DeSalis B, McLean AP, et al. Control of construction-associated nosocomial aspergillosis in an antiquated hematology unit. Infect Control Hosp Epidemiol. 1996;17:360–4.CrossRef Loo VG, Bertrand C, Dixon C, Vityé D, DeSalis B, McLean AP, et al. Control of construction-associated nosocomial aspergillosis in an antiquated hematology unit. Infect Control Hosp Epidemiol. 1996;17:360–4.CrossRef
23.
Zurück zum Zitat Fournel I, Sautour M, Lafon I, Sixt N, L’Ollivier C, Dalle F, et al. Airborne Aspergillus contamination during hospital construction works: efficacy of protective measures. Am J Infect Control. 2010;38:189–94.CrossRef Fournel I, Sautour M, Lafon I, Sixt N, L’Ollivier C, Dalle F, et al. Airborne Aspergillus contamination during hospital construction works: efficacy of protective measures. Am J Infect Control. 2010;38:189–94.CrossRef
24.
Zurück zum Zitat Abdul Salam Z-H, Karlin RB, Ling ML, Yang KS. The impact of portable high-efficiency particulate air filters on the incidence of invasive aspergillosis in a large acute tertiary-care hospital. Am J Infect Control. 2010;38:e1–7.CrossRef Abdul Salam Z-H, Karlin RB, Ling ML, Yang KS. The impact of portable high-efficiency particulate air filters on the incidence of invasive aspergillosis in a large acute tertiary-care hospital. Am J Infect Control. 2010;38:e1–7.CrossRef
25.
Zurück zum Zitat Özen M, Yılmaz G, Coşkun B, Topçuoğlu P, Öztürk B, Gündüz M, et al. A quasi-experimental study analyzing the effectiveness of portable high-efficiency particulate absorption filters in preventing infections in hematology patients during construction. Turk J Haematol. 2016;33:41–7.CrossRef Özen M, Yılmaz G, Coşkun B, Topçuoğlu P, Öztürk B, Gündüz M, et al. A quasi-experimental study analyzing the effectiveness of portable high-efficiency particulate absorption filters in preventing infections in hematology patients during construction. Turk J Haematol. 2016;33:41–7.CrossRef
26.
Zurück zum Zitat Bellanger A-P, Reboux G, Demonmerot F, Gbaguidi-Haore H, Millon L. Fungal aerocontamination exposure risk for patients in 3 successive locations of a pediatric hematology unit department: influence of air equipment and building structure on air quality. Am J Infect Control. 2017;45:e109–13.CrossRef Bellanger A-P, Reboux G, Demonmerot F, Gbaguidi-Haore H, Millon L. Fungal aerocontamination exposure risk for patients in 3 successive locations of a pediatric hematology unit department: influence of air equipment and building structure on air quality. Am J Infect Control. 2017;45:e109–13.CrossRef
27.
Zurück zum Zitat Engelhart S, Hanfland J, Glasmacher A, Krizek L, Schmidt-Wolf IGH, Exner M. Impact of portable air filtration units on exposure of haematology-oncology patients to airborne Aspergillus fumigatus spores under field conditions. J Hosp Infect. 2003;54:300–4.CrossRef Engelhart S, Hanfland J, Glasmacher A, Krizek L, Schmidt-Wolf IGH, Exner M. Impact of portable air filtration units on exposure of haematology-oncology patients to airborne Aspergillus fumigatus spores under field conditions. J Hosp Infect. 2003;54:300–4.CrossRef
28.
Zurück zum Zitat Brenier-Pinchart M-P, Coussa-Rivière L, Lebeau B, Mallaret M-R, Bulabois C-E, Ducki S, et al. Mobile air-decontamination unit and filamentous fungal load in the hematology ward: how efficient at the low-activity mode? Am J Infect Control. 2009;37:680–2.CrossRef Brenier-Pinchart M-P, Coussa-Rivière L, Lebeau B, Mallaret M-R, Bulabois C-E, Ducki S, et al. Mobile air-decontamination unit and filamentous fungal load in the hematology ward: how efficient at the low-activity mode? Am J Infect Control. 2009;37:680–2.CrossRef
29.
Zurück zum Zitat Fréalle E, Lestrez C, Skierlak T, Melboucy D, Guery B, Durand-Joly I, et al. Fungal aero-decontamination efficacy of mobile air-treatment systems. Med Mycol. 2011;49:825–33. Fréalle E, Lestrez C, Skierlak T, Melboucy D, Guery B, Durand-Joly I, et al. Fungal aero-decontamination efficacy of mobile air-treatment systems. Med Mycol. 2011;49:825–33.
30.
Zurück zum Zitat Bergeron V, Reboux G, Poirot JL, Laudinet N. Decreasing airborne contamination levels in high-risk hospital areas using a novel mobile air-treatment unit. Infect Control Hosp Epidemiol. 2007;28:1181–6.CrossRef Bergeron V, Reboux G, Poirot JL, Laudinet N. Decreasing airborne contamination levels in high-risk hospital areas using a novel mobile air-treatment unit. Infect Control Hosp Epidemiol. 2007;28:1181–6.CrossRef
Metadaten
Titel
Performance evaluation of a new mobile air-treatment technology at-rest and under normal work conditions in a conventional hematology room
verfasst von
Anne Pouvaret
Emmanuelle Tavernier
Jérôme Cornillon
Elisabeth Daguenet
Hélène Raberin
Florence Grattard
Philippe Berthelot
Denis Guyotat
Publikationsdatum
04.10.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
Health and Technology / Ausgabe 6/2020
Print ISSN: 2190-7188
Elektronische ISSN: 2190-7196
DOI
https://doi.org/10.1007/s12553-020-00480-z

Weitere Artikel der Ausgabe 6/2020