Performance of Combustible Facade Systems with Glass, ACP and Firestops in Full-Scale, Real Fire Experiments

verfasst von: Gaurav Srivastava, Dharmit Nakrani, Chinmay Ghoroi

Erschienen in: Fire Technology | Ausgabe 4/2020

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Combustible facade systems used in modern buildings envelops have received much attention in recent times due to their involvement in propagation of accidental fires in such buildings. This study presents findings from four full-scale real fire experiments performed on a three-story structure (each room being of plan dimensions \(10'\times 20'\) and story height \(10'\)) with combustible facade systems involving firestops, aluminum composite panels and glass. Two experiments simulated external fire-spread mechanism through the leap-frog effect (one with external fire source and one with internal fire source). The other two experiments were designed to study internal fire spread mechanism due to failure of firestops, a crucial design component of facade systems which is overlooked by most standardized facade fire tests. The experiments indicated that a facade fire can reach from one story to the next in about 3 min and hence, can severely limit the response and egress time for higher floors of a building. Further, the experiments showed that the facade system was exposed to heat flux levels in excess of \(100\,\mathrm{kW}/\mathrm{m}^{2}\) with maximum temperatures reaching \(1000^{\circ }\mathrm{C}\). The existing testing standards consider lower incident flux levels and the gas burners used in most existing test methods can reach maximum temperatures of around \(700^{\circ }\mathrm{C}\) only. These findings indicate a significant gap between current testing standards and real fire performance of facade systems. A study of failure mechanisms of individual components during the experiments showed the need of considering the system in its entirety rather than performing component level testing. The importance of firestops also became evident through these experiments. Properly designed firestop system ensured good compartmentation and prevented spread of fire to the upper floors, whereas improper firestop allowed fire to spread easily to upper floors. It is expected that the insights presented in this study will be useful to improve facade designs as well as to develop more robust testing procedures.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Andresen I, Haghighat F, Heiselberg P, Li Y, Olesen BW, Perino M, Principi P, da Silva FM, Yoshie R, Zhang J (2008) State-of-the-art review: vol. 1. State-of-the-art report: NNEX 44: integrating environmentally responsive elements in buildings, vol 1. Department of Civil Engineering, Aalborg University, Denmark. Annex 44 Website: www.civil.aau.dk/Annex44 Andresen I, Haghighat F, Heiselberg P, Li Y, Olesen BW, Perino M, Principi P, da Silva FM, Yoshie R, Zhang J (2008) State-of-the-art review: vol. 1. State-of-the-art report: NNEX 44: integrating environmentally responsive elements in buildings, vol 1. Department of Civil Engineering, Aalborg University, Denmark. Annex 44 Website: www.​civil.​aau.​dk/​Annex44
2.
Zurück zum Zitat Peng L, Ni Z, Huang X (2013) Review on the fire safety of exterior wall claddings in high-rise buildings in China. Procedia Eng 62:663–670.CrossRef Peng L, Ni Z, Huang X (2013) Review on the fire safety of exterior wall claddings in high-rise buildings in China. Procedia Eng 62:663–670.CrossRef
3.
Zurück zum Zitat Gandhi P, Jagdish V, Karthikeyan G, Chakravarthy A, Nakrani D, Ghoroi C, Srivastava G (2017) Performance of glass-ACP façade system in a full-scale real fire test in a \(\text{ G }+2\) structure. Procedia Eng 210:512–519.CrossRef Gandhi P, Jagdish V, Karthikeyan G, Chakravarthy A, Nakrani D, Ghoroi C, Srivastava G (2017) Performance of glass-ACP façade system in a full-scale real fire test in a \(\text{ G }+2\) structure. Procedia Eng 210:512–519.CrossRef
4.
Zurück zum Zitat The Rt Hon Sir Martin Moore-Bick (2019) Grenfell tower inquiry: phase 1 report. Technical report, United Kingdom The Rt Hon Sir Martin Moore-Bick (2019) Grenfell tower inquiry: phase 1 report. Technical report, United Kingdom
5.
Zurück zum Zitat Nguyen KTQ, Weerasinghe P, Mendis P, Ngo T, Barnett J (2016) Performance of modern building façades in fire: a comprehensive review. Electron J Struct Eng 16:1. Nguyen KTQ, Weerasinghe P, Mendis P, Ngo T, Barnett J (2016) Performance of modern building façades in fire: a comprehensive review. Electron J Struct Eng 16:1.
6.
Zurück zum Zitat White N, Delichatsios M (2015) Fire hazards of exterior wall assemblies containing combustible components. Springer, Berlin.CrossRef White N, Delichatsios M (2015) Fire hazards of exterior wall assemblies containing combustible components. Springer, Berlin.CrossRef
7.
Zurück zum Zitat White N, Delichatsios M, Ahrens M, Kimball A (2013) Fire hazards of exterior wall assemblies containing combustible components. In: MATEC Web of conferences, vol 9, p 02005. EDP Sciences White N, Delichatsios M, Ahrens M, Kimball A (2013) Fire hazards of exterior wall assemblies containing combustible components. In: MATEC Web of conferences, vol 9, p 02005. EDP Sciences
8.
Zurück zum Zitat White N, Delichatsios M (2014) Fire hazards of exterior wall assemblies containing combustible components. The Fire Protection Research Foundation, National Fire Protection Association (NFPA), Quincy, MA White N, Delichatsios M (2014) Fire hazards of exterior wall assemblies containing combustible components. The Fire Protection Research Foundation, National Fire Protection Association (NFPA), Quincy, MA
9.
Zurück zum Zitat Nishio Y, Yoshioka H, Noguchi T, Kanematsu M, Ando T, Hase Y, Hayakawa T (2016) Fire spread caused by combustible facades in Japan. Fire Technol 52(4), 1081–1106.CrossRef Nishio Y, Yoshioka H, Noguchi T, Kanematsu M, Ando T, Hase Y, Hayakawa T (2016) Fire spread caused by combustible facades in Japan. Fire Technol 52(4), 1081–1106.CrossRef
10.
Zurück zum Zitat Bisby L (2018) Grenfell tower inquiry: phase 1 final expert report. Technical report, The University of Edinburgh, United Kingdom Bisby L (2018) Grenfell tower inquiry: phase 1 final expert report. Technical report, The University of Edinburgh, United Kingdom
11.
Zurück zum Zitat Kolaitis DI, Asimakopoulou EK, Founti MA (2016) A full-scale fire test to investigate the fire behaviour of the ventilated facade system. In: Proceedings of 14th international fire and engineering conference Interflam, vol 2, pp 1127–1138 Kolaitis DI, Asimakopoulou EK, Founti MA (2016) A full-scale fire test to investigate the fire behaviour of the ventilated facade system. In: Proceedings of 14th international fire and engineering conference Interflam, vol 2, pp 1127–1138
12.
Zurück zum Zitat Bjegović D, Pečur IB, Milovanović B, Rukavina MJ, Bagarić M (2016) Comparative full-scale fire performance testing of ETICS systems. Gradevinar 68(05), 357–369. Bjegović D, Pečur IB, Milovanović B, Rukavina MJ, Bagarić M (2016) Comparative full-scale fire performance testing of ETICS systems. Gradevinar 68(05), 357–369.
13.
Zurück zum Zitat Östman B, Tsantaridis L (2015) Fire scenarios for multi-storey facades with emphasis on full-scale testing of wooden facades. Fire Technol 51(6), 1495–1510.CrossRef Östman B, Tsantaridis L (2015) Fire scenarios for multi-storey facades with emphasis on full-scale testing of wooden facades. Fire Technol 51(6), 1495–1510.CrossRef
14.
Zurück zum Zitat Kotthoff I, Riemesch-Speer J (2013) Mechanism of fire spread on facades and the new technical report of EOTA “large-scale fire performance testing of external wall cladding systems”. In: MATEC Web of conferences, vol 9, p 02010. EDP Sciences Kotthoff I, Riemesch-Speer J (2013) Mechanism of fire spread on facades and the new technical report of EOTA “large-scale fire performance testing of external wall cladding systems”. In: MATEC Web of conferences, vol 9, p 02010. EDP Sciences
15.
Zurück zum Zitat Srivastava G, Ghoroi C, Gandhi P, Jagdish V, Karthikeyan G, Chakravarthy A, Nakrani D (2018) Development of a unique full-scale real-fire façade testing facility at IIT Gandhinagar. Curr Sci 115(9):1782.CrossRef Srivastava G, Ghoroi C, Gandhi P, Jagdish V, Karthikeyan G, Chakravarthy A, Nakrani D (2018) Development of a unique full-scale real-fire façade testing facility at IIT Gandhinagar. Curr Sci 115(9):1782.CrossRef
16.
Zurück zum Zitat Kayacan I, Doğan ÖM (2008) Pyrolysis of low and high density polyethylene. part I: non-isothermal pyrolysis kinetics. Energy Sources Part A 30(5):385–391CrossRef Kayacan I, Doğan ÖM (2008) Pyrolysis of low and high density polyethylene. part I: non-isothermal pyrolysis kinetics. Energy Sources Part A 30(5):385–391CrossRef
17.
Zurück zum Zitat Shah J, Jan MR, Mabood F, Jabeen F (2010) Catalytic pyrolysis of ldpe leads to valuable resource recovery and reduction of waste problems. Energy Convers Manag 51(12), 2791–2801.CrossRef Shah J, Jan MR, Mabood F, Jabeen F (2010) Catalytic pyrolysis of ldpe leads to valuable resource recovery and reduction of waste problems. Energy Convers Manag 51(12), 2791–2801.CrossRef
18.
Zurück zum Zitat Bystritskaya EV, Karpukhin ON, Tsverava VG, Nepovinnykh VI, Rusin MY (2011) Thermal degradation of silicone sealant. Int Polym Sci Technol 38:47–51. Bystritskaya EV, Karpukhin ON, Tsverava VG, Nepovinnykh VI, Rusin MY (2011) Thermal degradation of silicone sealant. Int Polym Sci Technol 38:47–51.
19.
Zurück zum Zitat National Building Code of India Part 4 Fire and Life Safety (2005) Standard, Bureau of Indian Standards, New Delhi, India National Building Code of India Part 4 Fire and Life Safety (2005) Standard, Bureau of Indian Standards, New Delhi, India
20.
Zurück zum Zitat Zalok E, Eng P (2011) Validation of methodologies to determine fire load for use in structural fire protection. The Fire Protection Research Foundation, National Fire Protection Association (NFPA), Quincy, MA Zalok E, Eng P (2011) Validation of methodologies to determine fire load for use in structural fire protection. The Fire Protection Research Foundation, National Fire Protection Association (NFPA), Quincy, MA
21.
Zurück zum Zitat EN 1991-1-2 Eurocode 1: action on structures—part 1-2: general actions–actions on structures exposed to fire. Standard, European Committee for Standardization, Brussels (2002) EN 1991-1-2 Eurocode 1: action on structures—part 1-2: general actions–actions on structures exposed to fire. Standard, European Committee for Standardization, Brussels (2002)
Metadaten
Titel
Performance of Combustible Facade Systems with Glass, ACP and Firestops in Full-Scale, Real Fire Experiments
verfasst von
Gaurav Srivastava
Dharmit Nakrani
Chinmay Ghoroi
Publikationsdatum
18.01.2020
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 4/2020
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-019-00943-4

Weitere Artikel der Ausgabe 4/2020

Fire Technology 4/2020 Zur Ausgabe