Abstract

Polysomnography is the main diagnostic instrument for sleep apnea, but it is not convenient for patient to take frequent measurements at home. An in-home sleep test is a solution to help physicians to collect more information. Sleep medicine societies suggest that a home sleep-apnea testing device should measure at least oxygen saturation and breathing signals. To reduce the discomfort of measurement during sleep, the device should be also as small as possible. One possible measuring site for both signals is at the nose. The accuracy of oxygen saturation measurement relies on the quality of photoplethysmographic signals (PPG). PPG signals of red and near-infrared light measured at the nasal septum and nasal wing were compared. PPG signals were also measured at different body postures includes standing, sitting and supine.
Although nasal septum and wing are both thin layer of tissue, the perfusion index is greater and has a larger variation at nasal septum than at nasal wing. Although the PPG at nasal wing is relatively stable and not greatly affected by the autonomic nervous regulation, the change in signals with oxygen saturation is also small. Therefore, the nasal septum is a better position for measuring oxygen saturation at the nose.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Comerota, A.J., Throm, R.C., Kelly, P., Jaff, M.: Tissue (muscle) oxygen saturation (StO2): a new measure of symptomatic lower-extremity arterial disease. J. Vasc. Surg. 38(4), 724–729 (2003)CrossRef Comerota, A.J., Throm, R.C., Kelly, P., Jaff, M.: Tissue (muscle) oxygen saturation (StO2): a new measure of symptomatic lower-extremity arterial disease. J. Vasc. Surg. 38(4), 724–729 (2003)CrossRef
2.
Zurück zum Zitat Giswold, M.E., Landry, G.J., Sexton, G.J., Yeager, R.A., Edwards, J.M., Taylor Jr., L.M., Moneta, G.L.: Modifiable patient factors are associated with reverse vein graft occlusion in the era of duplex scan surveillance. J. Vasc. Surg. 37, 47–53 (2003)CrossRef Giswold, M.E., Landry, G.J., Sexton, G.J., Yeager, R.A., Edwards, J.M., Taylor Jr., L.M., Moneta, G.L.: Modifiable patient factors are associated with reverse vein graft occlusion in the era of duplex scan surveillance. J. Vasc. Surg. 37, 47–53 (2003)CrossRef
3.
Zurück zum Zitat Yu, G., Durduran, T., Gwen, L., Zhou, C., Chance, B., Mohler, E.R., Yodh, A.G.: Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies. J. Biomed. Opt. 10(2), 024–027 (2005)CrossRef Yu, G., Durduran, T., Gwen, L., Zhou, C., Chance, B., Mohler, E.R., Yodh, A.G.: Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies. J. Biomed. Opt. 10(2), 024–027 (2005)CrossRef
4.
Zurück zum Zitat De Felice, C., Latini, G., Vacca, P.: The pulse oximeter perfusion index as a predictor for high illness severity in neonates. Eur. J. Pediatr. 161, 561–562 (2002)CrossRef De Felice, C., Latini, G., Vacca, P.: The pulse oximeter perfusion index as a predictor for high illness severity in neonates. Eur. J. Pediatr. 161, 561–562 (2002)CrossRef
5.
Zurück zum Zitat McCully, K.K., Hamaoka, T.: Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle? Exerc. Sport Sci. Rev. 28(3), 123–127 (2000) McCully, K.K., Hamaoka, T.: Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle? Exerc. Sport Sci. Rev. 28(3), 123–127 (2000)
Metadaten
Titel
Photoplethysmographic Signals Measured at the Nose
verfasst von
Pin-Lu Li
Shao-Hung Lu
Kang-Ping Lin
Cheng-Lun Tsai
Copyright-Jahr
2020
DOI
https://doi.org/10.1007/978-3-030-30636-6_29

Neuer Inhalt