Skip to main content

2018 | OriginalPaper | Buchkapitel

Polyethylene Based Polymer for Joint Replacement

verfasst von : Saverio Affatato, Sami Abdel Jaber, Paola Taddei

Erschienen in: Biomaterials in Clinical Practice

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

It is well known that the debris generated from the Ultra-High molecular weight polyethylene socket may cause adverse tissue biological reactions leading to bone loss or osteolysis. A major consequence of the debris-induced osteolysis is the loosening of the implant inside the femur or acetabular cup, which often necessitates a revision surgery. Throughout the years several materials have been used in total hip replacement surgery. In particular, metals, ceramics and polymers are used nowadays for acetabular cup components. High molecular weight polyethylene is widely used and represents the principal polymeric material used in artificial replacement of hip and knee joints. High molecular weight polyethylene is known to have superior resistance to wear compared to other polymers. Actually, in order to increase long-term performance of Ultra-High molecular weight polyethylene acetabular cups, reinforcement as carbon fibres has been added in the polymeric matrix. The leading opinion is to develop a high strength reinforced polymeric matrix such as self-reinforced Ultra-High molecular weight polyethylene. With increasing patient longevity and activity levels, a search for the ultimate polymer is important.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Affatato S et al (2008) Comparative study on the wear behaviour of different conventional and cross-linked polyethylenes for total hip replacement. Tribol Int 41:813–822 Affatato S et al (2008) Comparative study on the wear behaviour of different conventional and cross-linked polyethylenes for total hip replacement. Tribol Int 41:813–822
Zurück zum Zitat Battaglia S et al (2014) A new protocol from real joint motion data for wear simulation in total knee arthroplasty: stair climbing. Med Eng Phys 36:1605–1610 Battaglia S et al (2014) A new protocol from real joint motion data for wear simulation in total knee arthroplasty: stair climbing. Med Eng Phys 36:1605–1610
Zurück zum Zitat Brach del Prever et al (1996) Unacceptable biodegradation of polyethylene in vivo. Biomaterials 17(9):873–878 Brach del Prever et al (1996) Unacceptable biodegradation of polyethylene in vivo. Biomaterials 17(9):873–878
Zurück zum Zitat Blunn G, Brach del Prever EM, Costa L, Fisher J, Freeman MAR (2002) Ultra high molecular-weight polyethylene (uhmwpe) in total knee replacement: fabrication, sterilisation and wear. J Bone Joint Surg [Br] 84(B):946–949 Blunn G, Brach del Prever EM, Costa L, Fisher J, Freeman MAR (2002) Ultra high molecular-weight polyethylene (uhmwpe) in total knee replacement: fabrication, sterilisation and wear. J Bone Joint Surg [Br] 84(B):946–949
Zurück zum Zitat Bostrom MP, Bennett AP, Rimnac CM, Wright TM (1994) The natural history of UHMWPE. Clin Orthop Rel Res 309:11–19 Bostrom MP, Bennett AP, Rimnac CM, Wright TM (1994) The natural history of UHMWPE. Clin Orthop Rel Res 309:11–19
Zurück zum Zitat Chenery DH (1997) Detection of peroxy species in ultra-high-molecular-weight polyethylene by Raman spectroscopy. Biomaterials 18(5):415–419 Chenery DH (1997) Detection of peroxy species in ultra-high-molecular-weight polyethylene by Raman spectroscopy. Biomaterials 18(5):415–419
Zurück zum Zitat Costa L, Luda MP, Trossarelli L, Brach del Prever EM, Crova M, Gallinaro P (1998) Oxidation in orthopaedic UHMWPE sterilized by gamma-radiation and ethylene oxide. Biomaterials 19:659–668 Costa L, Luda MP, Trossarelli L, Brach del Prever EM, Crova M, Gallinaro P (1998) Oxidation in orthopaedic UHMWPE sterilized by gamma-radiation and ethylene oxide. Biomaterials 19:659–668
Zurück zum Zitat Currier BH, Currier JH, Collier JP, Mayor MB, Scott RD (1997) Shelf life and in vivo duration. Impacts on performance of tibial bearings. Clin Orthop Rel Res 342:111–122CrossRef Currier BH, Currier JH, Collier JP, Mayor MB, Scott RD (1997) Shelf life and in vivo duration. Impacts on performance of tibial bearings. Clin Orthop Rel Res 342:111–122CrossRef
Zurück zum Zitat Edidin AA, Villarraga ML, Herr MP, Muth J, Yau SS, Kurtz SM (2002) Accelerated aging studies of UHMWPE. II. Virgin UHMWPE is not immune to oxidative degradation. J Biomed Mater Res 61:323–329CrossRef Edidin AA, Villarraga ML, Herr MP, Muth J, Yau SS, Kurtz SM (2002) Accelerated aging studies of UHMWPE. II. Virgin UHMWPE is not immune to oxidative degradation. J Biomed Mater Res 61:323–329CrossRef
Zurück zum Zitat Goldman M, Lee M, Gronsky R (1997) Oxidation of UHMWPE characterized by fourier transform infrared spectometry. J Biomed Mater Res 37:43–50CrossRef Goldman M, Lee M, Gronsky R (1997) Oxidation of UHMWPE characterized by fourier transform infrared spectometry. J Biomed Mater Res 37:43–50CrossRef
Zurück zum Zitat Hahn D et al (1997) Analysis of polyethylene wear debris using micro-Raman spectroscopy: a report on the presence of beta-carotene. J Biomed Mater Res 35:31–37 Hahn D et al (1997) Analysis of polyethylene wear debris using micro-Raman spectroscopy: a report on the presence of beta-carotene. J Biomed Mater Res 35:31–37
Zurück zum Zitat Heisel C, Silva M, Schmalzried P (2003) Bearing surface options for total hip replacement in young patients. J Bone Jt Surg Am 85:1367–1369 Heisel C, Silva M, Schmalzried P (2003) Bearing surface options for total hip replacement in young patients. J Bone Jt Surg Am 85:1367–1369
Zurück zum Zitat Jaber SA et al (2014) In vitro effects on mobile polyethylene insert under highly demanding daily activities: stair climbing. Int Orthop (SICOT). doi:10.1007/s00264-014-2622-5 Jaber SA et al (2014) In vitro effects on mobile polyethylene insert under highly demanding daily activities: stair climbing. Int Orthop (SICOT). doi:10.​1007/​s00264-014-2622-5
Zurück zum Zitat Jacob RJ, Pienkowski D, Lee KY, Hamilton DM, Schroeder D, Higgins J (2001) Time and depth dependent changes in cross-linking and oxidation of shelf-aged polyethylene acetabular liners. J Biomed Mater Res 56:168–176 Jacob RJ, Pienkowski D, Lee KY, Hamilton DM, Schroeder D, Higgins J (2001) Time and depth dependent changes in cross-linking and oxidation of shelf-aged polyethylene acetabular liners. J Biomed Mater Res 56:168–176
Zurück zum Zitat James SP, Oldinski RK, Zhang M, Schwartz H (2009) UHMWPE biomaterials handbook James SP, Oldinski RK, Zhang M, Schwartz H (2009) UHMWPE biomaterials handbook
Zurück zum Zitat Kurtz SM, Muratoglu OK, Evans M, Edidin AA (1999) Advances in the processing sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 20:1659–1688CrossRef Kurtz SM, Muratoglu OK, Evans M, Edidin AA (1999) Advances in the processing sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 20:1659–1688CrossRef
Zurück zum Zitat Kurtz SM, Muratoglu OK, Buchanan F, Currier B, Gsell R, Greer K, Gualtieri G, Johnson R, Schaffner S, Sevo K, Spiegelberg S, Shen FW, Yau SS (2001) Interlaboratory reproducibility of standard accelerated aging methods for oxidation of UHMWPE. Biomaterials 22:1731–1737CrossRef Kurtz SM, Muratoglu OK, Buchanan F, Currier B, Gsell R, Greer K, Gualtieri G, Johnson R, Schaffner S, Sevo K, Spiegelberg S, Shen FW, Yau SS (2001) Interlaboratory reproducibility of standard accelerated aging methods for oxidation of UHMWPE. Biomaterials 22:1731–1737CrossRef
Zurück zum Zitat Li S, Burstein AH (1994) Ultra-high molecular weight polyethylene: the material and its use in total joint implants. J Bone Joint Surg [Am] 76(A):1080–1089 Li S, Burstein AH (1994) Ultra-high molecular weight polyethylene: the material and its use in total joint implants. J Bone Joint Surg [Am] 76(A):1080–1089
Zurück zum Zitat McGloughlin TM, Kavanagh AG (2000) Wear of ultra-high molecular weight polyethylene (UHMWPE) in total knee prostheses: a review of key influences. Proc Inst Mech Eng [H] 214:349–359CrossRef McGloughlin TM, Kavanagh AG (2000) Wear of ultra-high molecular weight polyethylene (UHMWPE) in total knee prostheses: a review of key influences. Proc Inst Mech Eng [H] 214:349–359CrossRef
Zurück zum Zitat McKellop H (1996) Does gamma irradiation speed or slow wear?. AAOS, The American Academy of Orthopaedic Surgeons, USA McKellop H (1996) Does gamma irradiation speed or slow wear?. AAOS, The American Academy of Orthopaedic Surgeons, USA
Zurück zum Zitat McKellop HA, Shen FW, Campbell P, Ota T (1999) Effect of molecular weight, calcium stearate, and sterilization methods on the wear of uhmwpe acetabular cups in a hip joint simulator. J Orthop Res 17:329–339CrossRef McKellop HA, Shen FW, Campbell P, Ota T (1999) Effect of molecular weight, calcium stearate, and sterilization methods on the wear of uhmwpe acetabular cups in a hip joint simulator. J Orthop Res 17:329–339CrossRef
Zurück zum Zitat Mckellop H, Shen FW, Lu B, Campbell P, Salovey R (2000) Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. J Bone Jt Surg Am 82(A):1708–1725 Mckellop H, Shen FW, Lu B, Campbell P, Salovey R (2000) Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. J Bone Jt Surg Am 82(A):1708–1725
Zurück zum Zitat Muratoglu OK, Bragdon CR, O’Connor DO, Jasty M, Harris WH (2001) A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. J Artroplasty 16:149–160CrossRef Muratoglu OK, Bragdon CR, O’Connor DO, Jasty M, Harris WH (2001) A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. J Artroplasty 16:149–160CrossRef
Zurück zum Zitat Oonishi H (1995) Long term clinical results of THR: clinical results of THR of an alumina head with a cross-linked UHMWPE cup. Orthop Surg Traumatol 38(11):1255 Oonishi H (1995) Long term clinical results of THR: clinical results of THR of an alumina head with a cross-linked UHMWPE cup. Orthop Surg Traumatol 38(11):1255
Zurück zum Zitat Rimnac CM, Klein RW, Betts F, Wright TM (1994) Post-iIrradiation aging of ultra-high molecular weight polyethylene. J Bone Jt Surg Am 76(7):1052–1056CrossRef Rimnac CM, Klein RW, Betts F, Wright TM (1994) Post-iIrradiation aging of ultra-high molecular weight polyethylene. J Bone Jt Surg Am 76(7):1052–1056CrossRef
Zurück zum Zitat Ruan SL, Gao P, Yang XG, Yu TX (2003) Toughening high performance ultrahigh molecular weight polyethylene using multiwalled carbon nanotubes. China, Hong Kong Ruan SL, Gao P, Yang XG, Yu TX (2003) Toughening high performance ultrahigh molecular weight polyethylene using multiwalled carbon nanotubes. China, Hong Kong
Zurück zum Zitat Salernitano E, Migliaresi C (2003) Composite materials for biomedical application: a review. J of Appl Biomater Biomech 1:3–18 Salernitano E, Migliaresi C (2003) Composite materials for biomedical application: a review. J of Appl Biomater Biomech 1:3–18
Zurück zum Zitat Sanford WM, Saum KA (1995) Accelerated oxidative aging testing of UHMWPE. ORS 20:119 Sanford WM, Saum KA (1995) Accelerated oxidative aging testing of UHMWPE. ORS 20:119
Zurück zum Zitat Schmidt MB, Hamilton JV (1996) Calcium stearate-free UHMWPE therefore appears to be a superior choice for use in total joint replacement applications. In: 42nd ORS. Atlanta, USA Schmidt MB, Hamilton JV (1996) Calcium stearate-free UHMWPE therefore appears to be a superior choice for use in total joint replacement applications. In: 42nd ORS. Atlanta, USA
Zurück zum Zitat Shaw JH (1997) The effect of gamma irradiation on ultra high molecular weight polyethylene. Medical Devices Agency Shaw JH (1997) The effect of gamma irradiation on ultra high molecular weight polyethylene. Medical Devices Agency
Zurück zum Zitat Sobieraj MC, Rimnac CM (2009) Ultra high molecular weight polyethylene: Mechanics, morphology, and clinical behavior. J Mech Behav Biomed Mater 433–443 Sobieraj MC, Rimnac CM (2009) Ultra high molecular weight polyethylene: Mechanics, morphology, and clinical behavior. J Mech Behav Biomed Mater 433–443
Zurück zum Zitat Sun DC, Scmidig G, Stark C, Dumbleton JH (1996) A simple accelerated aging method for simulations of long-term oxidative aging ejects in UHMWPE implants. In: 42th ORS. Atlanta, USA Sun DC, Scmidig G, Stark C, Dumbleton JH (1996) A simple accelerated aging method for simulations of long-term oxidative aging ejects in UHMWPE implants. In: 42th ORS. Atlanta, USA
Zurück zum Zitat Sutula LC, Collier JP, Saum KA, Currier BH, Currier JH, Sandorf WM, Mayor MB, Wooding RE, Sperling DK, Williams IR, Kasprzak DJ, Surprenant VA (1995) Impact of gamma sterilization on clinical performance of polyethylene in the hip. Clin Orthop Rel Res 319:28–40 Sutula LC, Collier JP, Saum KA, Currier BH, Currier JH, Sandorf WM, Mayor MB, Wooding RE, Sperling DK, Williams IR, Kasprzak DJ, Surprenant VA (1995) Impact of gamma sterilization on clinical performance of polyethylene in the hip. Clin Orthop Rel Res 319:28–40
Zurück zum Zitat Taddei P et al (2006) Oxidation in ultrahigh molecular weight polyethylene and cross-linked polyethylene acetabular cups tested against roughened femoral heads in a hip joint simulator. Biomacromolecules 7:1912–1920 Taddei P et al (2006) Oxidation in ultrahigh molecular weight polyethylene and cross-linked polyethylene acetabular cups tested against roughened femoral heads in a hip joint simulator. Biomacromolecules 7:1912–1920
Zurück zum Zitat Wang A, Lin R, Polineni VK, Essner A, Stark C, Dumbleton JH (1998) Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement. Tribol Int 11:661–666CrossRef Wang A, Lin R, Polineni VK, Essner A, Stark C, Dumbleton JH (1998) Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement. Tribol Int 11:661–666CrossRef
Zurück zum Zitat Zhang YD, Wang YL, Huang Y, Wan YZ (2003) Preparation and properties of three-dimensional braided UHMWPE fiber reinfoced PMMA composites. Hong Kong, China Zhang YD, Wang YL, Huang Y, Wan YZ (2003) Preparation and properties of three-dimensional braided UHMWPE fiber reinfoced PMMA composites. Hong Kong, China
Metadaten
Titel
Polyethylene Based Polymer for Joint Replacement
verfasst von
Saverio Affatato
Sami Abdel Jaber
Paola Taddei
Copyright-Jahr
2018
DOI
https://doi.org/10.1007/978-3-319-68025-5_6

Neuer Inhalt