Skip to main content
Erschienen in: Measurement Techniques 5/2020

15.09.2020

Pre-Calibration of the Phase Interpolator of a Precision Time Interval Meter

verfasst von: D. G. Kalinov, V. I. Rimlyand

Erschienen in: Measurement Techniques | Ausgabe 5/2020

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The issues of precision determinations of time intervals for which results are essential, such as to estimate the metrological characteristics of structural systems of space navigational systems, are considered. A precision time-interval measurement unit has been designed. The dependence between observations of the measurement unit and the value under test has been established. A procedure for pre-calibration of a phase interpolator with nonuniform step size of quantization from the composition of the precision time-interval measurement unit has been developed and tested. In the course of creating the procedure, an optimal value was selected for the reference frequency, and the optimal size for the measuring matrix, consisting of sequentially connected logic gates, was studied. The extent of the effect of FPGA crystal temperature (integrated circuit) on the operation of a phase interpolator was determined. Requirements for test signals were developed, and the possibility of applying the reference signals of secondary standards for time and frequency (for example, the State Secondary Standard of units of time and frequency VET 1-7) was evaluated in the process of pre-calibration of the phase interpolator. Special software for determining the subquanta boundaries of the phase interpolator with a resolution of units of picoseconds was developed, and probability density functions of the transient process from one subquantum to the subsequent one were calculated. Requirements for the spectral composition of the frequency of the reference signal were provided, and the frequency detuning of a test signal relative to reference was determined. Verification of the a developed methodology for pre-calibration of the temporal position of the interpolator phase transitions was accomplished by repeated recalibrations and comparison of the obtained results.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat T. A. Lepyokhin and V. I. Nikolaev, Proc. 26th Int. Crimea Conf. Microwave Engineering and Telecommunication Technologies, KRYMIKO 2016, Sevastopol, Sept. 4–10, 2016, Sevastopol State University, Sevastopol (2016), pp. 2711–2715. T. A. Lepyokhin and V. I. Nikolaev, Proc. 26th Int. Crimea Conf. Microwave Engineering and Telecommunication Technologies, KRYMIKO 2016, Sevastopol, Sept. 4–10, 2016, Sevastopol State University, Sevastopol (2016), pp. 2711–2715.
2.
Zurück zum Zitat U. Yusupaliev, N. V. Radomskii, S. A. Shuteev, et al., “Measuring an interval of time with picosecond resolution for a system of laser–time position-sensing radiation detector,” Prikl. Fiz., No. 5, 113–118 (2009). U. Yusupaliev, N. V. Radomskii, S. A. Shuteev, et al., “Measuring an interval of time with picosecond resolution for a system of laser–time position-sensing radiation detector,” Prikl. Fiz., No. 5, 113–118 (2009).
3.
Zurück zum Zitat D. G. Kalinov, V. I. Rimlyand, G. A. Kalinov, et al., “Evaluation of the effect of key FGPA parameters of the CYCLONE series V for project design of digital VREMYa-KOD transformers,” Uchen. Zam. TOGU, 8, No. 3, 372–377 (2017). D. G. Kalinov, V. I. Rimlyand, G. A. Kalinov, et al., “Evaluation of the effect of key FGPA parameters of the CYCLONE series V for project design of digital VREMYa-KOD transformers,” Uchen. Zam. TOGU, 8, No. 3, 372–377 (2017).
4.
Zurück zum Zitat I. V. Bezmenov and I. Yu. Blinov, Theoretical Foundations for Construction of Models to Describe Current Time Scales and Frequency Standards: Monograph, VNIIFTRI, Mendeleevo (2015). I. V. Bezmenov and I. Yu. Blinov, Theoretical Foundations for Construction of Models to Describe Current Time Scales and Frequency Standards: Monograph, VNIIFTRI, Mendeleevo (2015).
7.
Zurück zum Zitat J. Wang, S. Liu, Q. Shen, et al., IEEE T. Nucl. Sci., April 2010, 57, No. 2, 446–450 (2010), DOI: 10.1109jam3.2009.2037958. J. Wang, S. Liu, Q. Shen, et al., IEEE T. Nucl. Sci., April 2010, 57, No. 2, 446–450 (2010), DOI: 10.1109jam3.2009.2037958.
11.
Zurück zum Zitat V. A. Chulkov, Interpolating Synchronization Devices and Information Transformers, Fizmalit, Moscow (2010). V. A. Chulkov, Interpolating Synchronization Devices and Information Transformers, Fizmalit, Moscow (2010).
Metadaten
Titel
Pre-Calibration of the Phase Interpolator of a Precision Time Interval Meter
verfasst von
D. G. Kalinov
V. I. Rimlyand
Publikationsdatum
15.09.2020
Verlag
Springer US
Erschienen in
Measurement Techniques / Ausgabe 5/2020
Print ISSN: 0543-1972
Elektronische ISSN: 1573-8906
DOI
https://doi.org/10.1007/s11018-020-01795-z

Weitere Artikel der Ausgabe 5/2020

Measurement Techniques 5/2020 Zur Ausgabe