Abstract

We propose a radiation-free three dimensional (3D) navigation and vasculature reconstruction method to reduce aortic stent graft deployment time and repeated exposures to high doses of X-ray radiation. 2D intraoperative US images are fused with 3D preoperative magnetic resonance (MR) image to provide intuitive 3D navigation for deployment of the stent-graft in the proposed system. On the other hand, calibrated 2D US images track catheter’s tip and construct intraoperative 3D aortic model by combining segmented intravascular ultrasound (IVUS) images. The constructed 3D aortic models can quantitatively assess morphological characteristics of aortic to assist deployment of stent graft. This system was validated by using in vitro cardiac and aorta phantom. The mean target registration error of 2D US-3D MR registration was 2.70 mm and the average tracking error of position of IVUS catheter’s tip was 1.12 mm. Accurate contours detection results in IVUS images were acquired. Meanwhile, Hausdorff distances are 0.78 mm and 0.59 mm for outer and inner contours, respectively; Dice coefficients are 90.21 % and 89.96 %. Experiment results demonstrate that our radiation-free navigation and 3D vasculature reconstruction method is promising for deployment of stent graft in vivo studies.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Dake, M.D., Kato, N., Mitchell, R.S., et al.: Endovascular stent–graft placement for the treatment of acute aortic dissection. New. Engl. J. Med. 340(20), 1546–1552 (1999)CrossRef Dake, M.D., Kato, N., Mitchell, R.S., et al.: Endovascular stent–graft placement for the treatment of acute aortic dissection. New. Engl. J. Med. 340(20), 1546–1552 (1999)CrossRef
2.
Zurück zum Zitat Timmins, L.H., Meyer, C.A., Moreno, M.R., et al.: Effects of stent design and atherosclerotic plaque composition on arterial wall biomechanics. J. Endovasc. Ther. 15(6), 643–654 (2008)CrossRef Timmins, L.H., Meyer, C.A., Moreno, M.R., et al.: Effects of stent design and atherosclerotic plaque composition on arterial wall biomechanics. J. Endovasc. Ther. 15(6), 643–654 (2008)CrossRef
3.
Zurück zum Zitat Vykoukal, D., Chinnadurai, P., Davies, M.G.: Cardiovascular imaging, navigation and intervention: hybrid imaging and therapeutics. In: Garbey, M., Bass, B.L., Berceli, S., Collet, C., Cerveri, P. (eds.) Computational Surgery and Dual Training, pp. 125–148. Springer, New York (2014)CrossRef Vykoukal, D., Chinnadurai, P., Davies, M.G.: Cardiovascular imaging, navigation and intervention: hybrid imaging and therapeutics. In: Garbey, M., Bass, B.L., Berceli, S., Collet, C., Cerveri, P. (eds.) Computational Surgery and Dual Training, pp. 125–148. Springer, New York (2014)CrossRef
4.
Zurück zum Zitat Fagan, T., Kay, J., Carroll, J., et al.: 3-D guidance of complex pulmonary artery stent placement using reconstructed rotational angiography with live overlay. Cathet. Cardio. Interv. 79(3), 414–421 (2012)CrossRef Fagan, T., Kay, J., Carroll, J., et al.: 3-D guidance of complex pulmonary artery stent placement using reconstructed rotational angiography with live overlay. Cathet. Cardio. Interv. 79(3), 414–421 (2012)CrossRef
5.
Zurück zum Zitat Rhode, K.S., Sermesant, M., Brogan, D., et al.: A system for real-time XMR guided cardiovascular intervention. IEEE Trans. Med. Imaging 24(11), 1428–1440 (2005)CrossRef Rhode, K.S., Sermesant, M., Brogan, D., et al.: A system for real-time XMR guided cardiovascular intervention. IEEE Trans. Med. Imaging 24(11), 1428–1440 (2005)CrossRef
6.
Zurück zum Zitat Abi-Jaoudeh, N., Glossop, N., Dake, M., et al.: Electromagnetic navigation for thoracic aortic stent-graft deployment: a pilot study in swine. J. Vasc. Interv. Radiol. 21(6), 888–895 (2010)CrossRef Abi-Jaoudeh, N., Glossop, N., Dake, M., et al.: Electromagnetic navigation for thoracic aortic stent-graft deployment: a pilot study in swine. J. Vasc. Interv. Radiol. 21(6), 888–895 (2010)CrossRef
7.
Zurück zum Zitat De Lambert, A., Esneault, S., Lucas, A., et al.: Electromagnetic tracking for registration and navigation in endovascular aneurysm repair: a phantom study. Eur. J. Vasc. Endovasc. 43(6), 684–689 (2012)CrossRef De Lambert, A., Esneault, S., Lucas, A., et al.: Electromagnetic tracking for registration and navigation in endovascular aneurysm repair: a phantom study. Eur. J. Vasc. Endovasc. 43(6), 684–689 (2012)CrossRef
8.
Zurück zum Zitat Nishimura, R.A., Edwards, W.D., et al.: Intravascular ultrasound imaging: in vitro validation and pathologic correlation. Am. Coil. Cardiol. 16, 145–154 (1990)CrossRef Nishimura, R.A., Edwards, W.D., et al.: Intravascular ultrasound imaging: in vitro validation and pathologic correlation. Am. Coil. Cardiol. 16, 145–154 (1990)CrossRef
9.
Zurück zum Zitat Brodoefel, H., Burgstahler, C., et al.: Accuracy of dual-source CT in the characterisation of non-calcified plaque: use of a colour-coded analysis compared with virtual histology intravascular ultrasound. Br. J. Radiol. 82, 805–812 (2009)CrossRef Brodoefel, H., Burgstahler, C., et al.: Accuracy of dual-source CT in the characterisation of non-calcified plaque: use of a colour-coded analysis compared with virtual histology intravascular ultrasound. Br. J. Radiol. 82, 805–812 (2009)CrossRef
10.
Zurück zum Zitat Sanz-Requena, R., Moratal, D., García-Sánchez, D.R., et al.: Automatic segmentation and 3D reconstruction of intravascular ultrasound images for a fast preliminar evaluation of vessel pathologies. Comput. Med. Imag. Graph 31(2), 71–80 (2007)CrossRef Sanz-Requena, R., Moratal, D., García-Sánchez, D.R., et al.: Automatic segmentation and 3D reconstruction of intravascular ultrasound images for a fast preliminar evaluation of vessel pathologies. Comput. Med. Imag. Graph 31(2), 71–80 (2007)CrossRef
11.
Zurück zum Zitat Shi, C., Kojima, M., Tercero, C., et al.: Intravascular modeling and navigation for stent graft installation based on data fusion between intravascular ultrasound and electromagnetic tracking sensor. In: 2012 IEEE International Symposium on Micro-NanoMechatronics and Human Science (MHS), pp. 229–234 (2012) Shi, C., Kojima, M., Tercero, C., et al.: Intravascular modeling and navigation for stent graft installation based on data fusion between intravascular ultrasound and electromagnetic tracking sensor. In: 2012 IEEE International Symposium on Micro-NanoMechatronics and Human Science (MHS), pp. 229–234 (2012)
12.
Zurück zum Zitat Franke, A., Kuhl, H.P., et al.: Quantitative analysis of the morphology of secundum-type atrial septal defects and their dynamic change using transesophageal three-dimensional echocardiography. Circulation 96, II323–II327 (1997) Franke, A., Kuhl, H.P., et al.: Quantitative analysis of the morphology of secundum-type atrial septal defects and their dynamic change using transesophageal three-dimensional echocardiography. Circulation 96, II323–II327 (1997)
13.
Zurück zum Zitat Finn, J.P., Nael, K., Deshpande, V., et al.: Cardiac MR imaging: state of the technology 1. Radiology 241(2), 338–354 (2006)CrossRef Finn, J.P., Nael, K., Deshpande, V., et al.: Cardiac MR imaging: state of the technology 1. Radiology 241(2), 338–354 (2006)CrossRef
14.
Zurück zum Zitat Lindseth, F., Tangen, G.A., Langø, T., et al.: Probe calibration for freehand 3-D ultrasound. Ultrasound Med. Biol. 29(11), 1607–1623 (2003)CrossRef Lindseth, F., Tangen, G.A., Langø, T., et al.: Probe calibration for freehand 3-D ultrasound. Ultrasound Med. Biol. 29(11), 1607–1623 (2003)CrossRef
15.
Zurück zum Zitat Bergmeir, C., Seitel, M., Frank, C., et al.: Comparing calibration approaches for 3D ultrasound probes. Int. J. Comput. Assist. Radiol. Surg. 4(2), 203–213 (2009)CrossRef Bergmeir, C., Seitel, M., Frank, C., et al.: Comparing calibration approaches for 3D ultrasound probes. Int. J. Comput. Assist. Radiol. Surg. 4(2), 203–213 (2009)CrossRef
16.
Zurück zum Zitat Chen, F., Liao, R., Liao, H.: Fast registration of intraoperative ultrasound and preoperative MR images based on calibrations of 2D and 3D ultrasound probes. In: Jaffray, D.A. (ed.) World Congress on Medical Physics and Biomedical Engineering, pp. 220–223. Springer, Toronto (2015) Chen, F., Liao, R., Liao, H.: Fast registration of intraoperative ultrasound and preoperative MR images based on calibrations of 2D and 3D ultrasound probes. In: Jaffray, D.A. (ed.) World Congress on Medical Physics and Biomedical Engineering, pp. 220–223. Springer, Toronto (2015)
17.
Zurück zum Zitat Lewis, J.P.: Fast template matching. In: Vision Interface, pp. 15–19 (1995) Lewis, J.P.: Fast template matching. In: Vision Interface, pp. 15–19 (1995)
18.
Zurück zum Zitat Kass, M., Witkin, A., Terzopoulos, D.: Snakes: active contour models. Int. J. Comput. Vis. 1(4), 321–331 (1988)CrossRefMATH Kass, M., Witkin, A., Terzopoulos, D.: Snakes: active contour models. Int. J. Comput. Vis. 1(4), 321–331 (1988)CrossRefMATH
19.
Zurück zum Zitat Plissiti, M.E., Fotiadis, D.I., Michalis, L.K., et al.: An automated method for lumen and media-adventitia border detection in a sequence of IVUS frames. IEEE Trans. Inf. Technol. Biomed. 8(2), 131–141 (2004)CrossRef Plissiti, M.E., Fotiadis, D.I., Michalis, L.K., et al.: An automated method for lumen and media-adventitia border detection in a sequence of IVUS frames. IEEE Trans. Inf. Technol. Biomed. 8(2), 131–141 (2004)CrossRef
20.
Zurück zum Zitat Dice, L.R.: Measures of the amount of ecologic association between species. Ecology 26(3), 297–302 (1945)CrossRef Dice, L.R.: Measures of the amount of ecologic association between species. Ecology 26(3), 297–302 (1945)CrossRef
21.
Zurück zum Zitat Huttenlocher, D.P., Klanderman, G.A., Rucklidge, W.J.: Comparing images using the Hausdorff distance. IEEE Trans. Pattern. Anal. Mach. Intell. 15(9), 850–863 (1993)CrossRef Huttenlocher, D.P., Klanderman, G.A., Rucklidge, W.J.: Comparing images using the Hausdorff distance. IEEE Trans. Pattern. Anal. Mach. Intell. 15(9), 850–863 (1993)CrossRef
Metadaten
Titel
Radiation-Free 3D Navigation and Vascular Reconstruction for Aortic Stent Graft Deployment
verfasst von
Fang Chen
Jia Liu
Hongen Liao
Copyright-Jahr
2016
DOI
https://doi.org/10.1007/978-3-319-43775-0_6