Erschienen in: International Journal of Computer Assisted Radiology and Surgery 3/2014

01.05.2014 | Original Article

Ray-casting based evaluation framework for haptic force feedback during percutaneous transhepatic catheter drainage punctures

verfasst von: Andre Mastmeyer, Tobias Hecht, Dirk Fortmeier, Heinz Handels

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 3/2014

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Purpose

   Development of new needle insertion force feedback algorithms requires comparison with a gold standard method. A new evaluation framework was formulated and tested on needle punctures for percutaneous transhepatic catheter drainage (PTCD).

Methods

   Needle insertion is an established procedure for minimally invasive interventions in the liver. Up-to-date, needle insertions are precisely planned using 2D axial CT slices from 3D data sets. To provide a 3D virtual reality and haptic training and planning environment, the full segmentation of patient data is often a mandatory step. To lessen the time required for manual segmentation, we propose direct haptic volume-rendering based on CT gray values and partially segmented patient data. The core contribution is a new force output evaluation method driven by a ray-casting technique that defines paths from the skin to target structures, i.e., the right hepatic duct near the juncture with the common hepatic duct. A ray-casting method computes insertion trajectories from the skin to the duct considering no-go structures and plausibility criteria. A rating system scores each trajectory. Finally, the best insertion trajectories are selected that reach the target. Along the selected paths, force output comparison between a reference system and the new haptic force output algorithm is carried out, quantified and visualized.

Results

   The evaluation framework is presented along with an exemplary study of the liver using the atlas data set from a reference patient. In a comparison of our reference method to a newer algorithm, force outputs are found to be similar in 99 % of the paths.

Conclusion

   The proposed evaluation framework allows reliable detection of problematic PTCD trajectories and provides valuable hints to improve force feedback algorithm development.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Abolhassani N, Patel R, Moallem M (2007) Needle insertion into soft tissue: a survey. Med Eng Phys 29(4):413–431PubMedCrossRef Abolhassani N, Patel R, Moallem M (2007) Needle insertion into soft tissue: a survey. Med Eng Phys 29(4):413–431PubMedCrossRef
2.
Zurück zum Zitat Baegert C, Villard C, Schreck P, Soler L (2007) Multi-criteria trajectory planning for hepatic radiofrequency ablation. MICCAI Med Image Comput Comput Interv 4792:676–684 Baegert C, Villard C, Schreck P, Soler L (2007) Multi-criteria trajectory planning for hepatic radiofrequency ablation. MICCAI Med Image Comput Comput Interv 4792:676–684
3.
Zurück zum Zitat Basdogan C, Sedef M, Harders M, Wesarg S (2007) VR-based simulators for training in minimally invasive surgery. IEEE Comput Graph Appl 27(2):54–66PubMedCrossRef Basdogan C, Sedef M, Harders M, Wesarg S (2007) VR-based simulators for training in minimally invasive surgery. IEEE Comput Graph Appl 27(2):54–66PubMedCrossRef
4.
Zurück zum Zitat Bresenham JE (1965) Algorithm for computer control of a digital plotter. IBM Syst J 4(1):25–30CrossRef Bresenham JE (1965) Algorithm for computer control of a digital plotter. IBM Syst J 4(1):25–30CrossRef
5.
Zurück zum Zitat Campadelli P, Casiraghi E, Esposito A (2009) Liver segmentation from computed tomography scans: a survey and a new algorithm. Artif Intell Med 45(2–3):185–196PubMedCrossRef Campadelli P, Casiraghi E, Esposito A (2009) Liver segmentation from computed tomography scans: a survey and a new algorithm. Artif Intell Med 45(2–3):185–196PubMedCrossRef
6.
Zurück zum Zitat Dierckx P, Suetens P, Vandermeulen D (1988) An algorithm for surface reconstruction from planar contours using smoothing splines. J Comput Appl Math 23(3):367–388CrossRef Dierckx P, Suetens P, Vandermeulen D (1988) An algorithm for surface reconstruction from planar contours using smoothing splines. J Comput Appl Math 23(3):367–388CrossRef
7.
Zurück zum Zitat Engel K (2006) Real-time volume graphics. Ak Peters Series. AK Peters, Limited Engel K (2006) Real-time volume graphics. Ak Peters Series. AK Peters, Limited
8.
Zurück zum Zitat Färber M, Hoeborn E, Dalek D, Hummel F, Gerloff C, Bohn CA, Handels H (2008) Training and evaluation of lumbar punctures in a VR-environment using a 6DOF haptic device. MMVR16/Stud Health Technol. Inform 132:112–114 Färber M, Hoeborn E, Dalek D, Hummel F, Gerloff C, Bohn CA, Handels H (2008) Training and evaluation of lumbar punctures in a VR-environment using a 6DOF haptic device. MMVR16/Stud Health Technol. Inform 132:112–114
9.
Zurück zum Zitat Färber M, Hummel F, Gerloff C, Handels H (2009) Virtual reality simulator for the training of lumbar punctures. Methods Inf Med 48(5):493–501PubMedCrossRef Färber M, Hummel F, Gerloff C, Handels H (2009) Virtual reality simulator for the training of lumbar punctures. Methods Inf Med 48(5):493–501PubMedCrossRef
10.
Zurück zum Zitat Heimann T, van Ginneken B, Styner M, Arzhaeva Y, Aurich V, Bauer C, Beck A, Becker C, Beichel R, Bekes G, Bello F, Binnig G, Bischof H, Bornik A, Cashman P, Chi Y, Cordova A, Dawant B, Fidrich M, Furst J, Furukawa D, Grenacher L, Hornegger J, Kainmuller D, Kitney R, Kobatake H, Lamecker H, Lange T, Lee J, Lennon B, Li R, Li S, Meinzer HP, Nemeth G, Raicu D, Rau AM, van Rikxoort E, Rousson M, Rusko L, Saddi K, Schmidt G, Seghers D, Shimizu A, Slagmolen P, Sorantin E, Soza G, Susomboon R, Waite J, Wimmer A, Wolf I (2009) Comparison and evaluation of methods for liver segmentation from CT datasets. Trans Med Imaging 28(8):1251–1265 Heimann T, van Ginneken B, Styner M, Arzhaeva Y, Aurich V, Bauer C, Beck A, Becker C, Beichel R, Bekes G, Bello F, Binnig G, Bischof H, Bornik A, Cashman P, Chi Y, Cordova A, Dawant B, Fidrich M, Furst J, Furukawa D, Grenacher L, Hornegger J, Kainmuller D, Kitney R, Kobatake H, Lamecker H, Lange T, Lee J, Lennon B, Li R, Li S, Meinzer HP, Nemeth G, Raicu D, Rau AM, van Rikxoort E, Rousson M, Rusko L, Saddi K, Schmidt G, Seghers D, Shimizu A, Slagmolen P, Sorantin E, Soza G, Susomboon R, Waite J, Wimmer A, Wolf I (2009) Comparison and evaluation of methods for liver segmentation from CT datasets. Trans Med Imaging 28(8):1251–1265
11.
Zurück zum Zitat Liwu L (1997) Practical clinical ultrasound diagnosis. World Scientific Publishing Company Liwu L (1997) Practical clinical ultrasound diagnosis. World Scientific Publishing Company
12.
Zurück zum Zitat Lundin K, Ynnerman A, Gudmundsson B (2002) Proxy-based haptic feedback from volumetric density data. Eurohaptics Conference pp 104–109 Lundin K, Ynnerman A, Gudmundsson B (2002) Proxy-based haptic feedback from volumetric density data. Eurohaptics Conference pp 104–109
13.
Zurück zum Zitat Mastmeyer A, Fortmeier D, Handels H (2012) Direct haptic volume rendering in lumbar puncture simulation. Stud Health Technol Inform 173:280–286PubMed Mastmeyer A, Fortmeier D, Handels H (2012) Direct haptic volume rendering in lumbar puncture simulation. Stud Health Technol Inform 173:280–286PubMed
14.
Zurück zum Zitat Mastmeyer A, Fortmeier D, Handels H (2012) Anisotropic diffusion for direct haptic volume rendering in lumbar puncture simulation. In: Tolxdorff T, Deserno TM, Handels H, Meinzer HP (Hrsg.), Bildverarbeitung für die Medizin, (2012) Informatik aktuell. Springer Verlag, Berlin, pp 286–291 Mastmeyer A, Fortmeier D, Handels H (2012) Anisotropic diffusion for direct haptic volume rendering in lumbar puncture simulation. In: Tolxdorff T, Deserno TM, Handels H, Meinzer HP (Hrsg.), Bildverarbeitung für die Medizin, (2012) Informatik aktuell. Springer Verlag, Berlin, pp 286–291
15.
Zurück zum Zitat Mastmeyer A, Fortmeier D, Maghsoudi E, Simon M, Handels H (2013) Patch-based label fusion using local confidence-measures and weak segmentations. SPIE Medical Imaging 2013 Mastmeyer A, Fortmeier D, Maghsoudi E, Simon M, Handels H (2013) Patch-based label fusion using local confidence-measures and weak segmentations. SPIE Medical Imaging 2013
16.
Zurück zum Zitat Mastmeyer A, Hecht T, Fortmeier D, Handels H (2013) Raycasting based evaluation framework for needle insertion force feedback algorithms. In: Tolxdorff T, Deserno TM, Handels H, Meinzer HP (Hrsg.), Bildverarbeitung für die Medizin, (2013) Informatik aktuell. Springer, Berlin, pp 3–8 Mastmeyer A, Hecht T, Fortmeier D, Handels H (2013) Raycasting based evaluation framework for needle insertion force feedback algorithms. In: Tolxdorff T, Deserno TM, Handels H, Meinzer HP (Hrsg.), Bildverarbeitung für die Medizin, (2013) Informatik aktuell. Springer, Berlin, pp 3–8
17.
Zurück zum Zitat Mharib AM, Ramli AR, Mashohor S, Mahmood RB (2011) Survey on liver CT image segmentation methods. Artif Intell Rev 37(2):83–95CrossRef Mharib AM, Ramli AR, Mashohor S, Mahmood RB (2011) Survey on liver CT image segmentation methods. Artif Intell Rev 37(2):83–95CrossRef
18.
Zurück zum Zitat Murphy MJ (2004) Tracking moving organs in real time. Semin Radiat Oncol 14(1):91–100 Murphy MJ (2004) Tracking moving organs in real time. Semin Radiat Oncol 14(1):91–100
19.
Zurück zum Zitat Nath S, Chen Z, Yue N, Trumpore S, Peschel R (2000) Dosimetric effects of needle divergence in prostate seed implant using 125l and 103pd radioactive seeds. Med Phys 27(5):1058–1066PubMedCrossRef Nath S, Chen Z, Yue N, Trumpore S, Peschel R (2000) Dosimetric effects of needle divergence in prostate seed implant using 125l and 103pd radioactive seeds. Med Phys 27(5):1058–1066PubMedCrossRef
20.
Zurück zum Zitat Pereira PL (2007) Actual role of radiofrequency ablation of liver metastases. Eur Radiol 17(8):2062–2070PubMedCrossRef Pereira PL (2007) Actual role of radiofrequency ablation of liver metastases. Eur Radiol 17(8):2062–2070PubMedCrossRef
21.
Zurück zum Zitat Ruspini DC, Kolarov K, Khatib O (1997) The haptic display of complex graphical environments. In: Proceedings of the 24th annual conference on Computer graphics and interactive techniques SIGGRAPH vol 97, pp 345–352 Ruspini DC, Kolarov K, Khatib O (1997) The haptic display of complex graphical environments. In: Proceedings of the 24th annual conference on Computer graphics and interactive techniques SIGGRAPH vol 97, pp 345–352
22.
Zurück zum Zitat Seitel A, Engel M, Sommer CM, Radeleff BA, Caroline EV, Baegert C, Fangerau M, Fritzsche KH, Yung K, Meinzer HP, Maier-Hein L (2011) Computer-assisted trajectory planning for percutaneous needle insertions. Med Phys 38(6):3246–3259PubMedCrossRef Seitel A, Engel M, Sommer CM, Radeleff BA, Caroline EV, Baegert C, Fangerau M, Fritzsche KH, Yung K, Meinzer HP, Maier-Hein L (2011) Computer-assisted trajectory planning for percutaneous needle insertions. Med Phys 38(6):3246–3259PubMedCrossRef
23.
Zurück zum Zitat Ullrich S, Grottke O, Fried E, Frommen T, Liao W, Rossaint R, Kuhlen T, Deserno TM (2009) An intersubject variable regional anesthesia simulator with a virtual patient architecture. Int J Comput Assist Radiol Surg 4(6):561–570PubMedCrossRef Ullrich S, Grottke O, Fried E, Frommen T, Liao W, Rossaint R, Kuhlen T, Deserno TM (2009) An intersubject variable regional anesthesia simulator with a virtual patient architecture. Int J Comput Assist Radiol Surg 4(6):561–570PubMedCrossRef
24.
Zurück zum Zitat Ullrich S, Kuhlen T (2012) Haptic palpation for medical simulation in virtual environments. IEEE Trans Vis Comput Gr 18(4):617–625CrossRef Ullrich S, Kuhlen T (2012) Haptic palpation for medical simulation in virtual environments. IEEE Trans Vis Comput Gr 18(4):617–625CrossRef
Metadaten
Titel
Ray-casting based evaluation framework for haptic force feedback during percutaneous transhepatic catheter drainage punctures
verfasst von
Andre Mastmeyer
Tobias Hecht
Dirk Fortmeier
Heinz Handels
Publikationsdatum
01.05.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 3/2014
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-013-0959-7

Weitere Artikel der Ausgabe 3/2014

International Journal of Computer Assisted Radiology and Surgery 3/2014 Zur Ausgabe

Premium Partner