Abstract

Purpose

Unfortunately, the current re-excision rates for breast conserving surgeries due to positive margins average 20–40 %. The high re-excision rates arise from difficulty in localizing tumor boundaries intraoperatively and lack of real-time information on the presence of residual disease. The work presented here introduces the use of supine magnetic resonance (MR) images, digitization technology, and biomechanical models to investigate the capability of using an image guidance system to localize tumors intraoperatively.

Methods

Preoperative supine MR images were used to create patient-specific biomechanical models of the breast tissue, chest wall, and tumor. In a mock intraoperative setup, a laser range scanner was used to digitize the breast surface and tracked ultrasound was used to digitize the chest wall and tumor. Rigid registration combined with a novel nonrigid registration routine was used to align the preoperative and intraoperative patient breast and tumor. The registration framework is driven by breast surface data (laser range scan of visible surface), ultrasound chest wall surface, and MR-visible fiducials. Tumor localizations by tracked ultrasound were only used to evaluate the fidelity of aligning preoperative MR tumor contours to physical patient space. The use of tracked ultrasound to digitize subsurface features to constrain our nonrigid registration approach and to assess the fidelity of our framework makes this work unique. Two patient subjects were analyzed as a preliminary investigation toward the realization of this supine image-guided approach.

Results

An initial rigid registration was performed using adhesive MR-visible fiducial markers for two patients scheduled for a lumpectomy. For patient 1, the rigid registration resulted in a root-mean-square fiducial registration error (FRE) of 7.5 mm and the difference between the intraoperative tumor centroid as visualized with tracked ultrasound imaging and the registered preoperative MR counterpart was 6.5 mm. Nonrigid correction resulted in a decrease in FRE to 2.9 mm and tumor centroid difference to 5.5 mm. For patient 2, rigid registration resulted in a FRE of 8.8 mm and a 3D tumor centroid difference of 12.5 mm. Following nonrigid correction for patient 2, the FRE was reduced to 7.4 mm and the 3D tumor centroid difference was reduced to 5.3 mm.

Conclusion

Using our prototype image-guided surgery platform, we were able to align intraoperative data with preoperative patient-specific models with clinically relevant accuracy; i.e., tumor centroid localizations of approximately 5.3–5.5 mm.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Adkisson CD, Bagaria SP, Parker AS, Bray JM, Gibson T, Thomas CS, Heckman MG, McLaughlin SA (2012) Which eligible breast conservation patients choose mastectomy in the setting of newly diagnosed breast cancer? Ann Surg Oncol 19(4):1129–1136CrossRefPubMed Adkisson CD, Bagaria SP, Parker AS, Bray JM, Gibson T, Thomas CS, Heckman MG, McLaughlin SA (2012) Which eligible breast conservation patients choose mastectomy in the setting of newly diagnosed breast cancer? Ann Surg Oncol 19(4):1129–1136CrossRefPubMed
2.
Zurück zum Zitat Alderliesten T, Loo C, Paape A, Muller S, Rutgers E, Peeters MJV, Gilhuijs K (2010) On the feasibility of mri-guided navigation to demarcate breast cancer for breast-conserving surgery. Med Phys 37(6):2617–2626CrossRefPubMed Alderliesten T, Loo C, Paape A, Muller S, Rutgers E, Peeters MJV, Gilhuijs K (2010) On the feasibility of mri-guided navigation to demarcate breast cancer for breast-conserving surgery. Med Phys 37(6):2617–2626CrossRefPubMed
3.
Zurück zum Zitat Allweis TM, Kaufman Z, Lelcuk S, Pappo I, Karni T, Schneebaum S, Spector R, Schindel A, Hershko D, Zilberman M, Sayfan J, Berlin Y, Hadary A, Olsha O, Paran H, Gutman M, Carmon M (2008) A prospective, randomized, controlled, multicenter study of a real-time, intraoperative probe for positive margin detection in breast-conserving surgery. Am J Surg 196(4):483–489CrossRefPubMed Allweis TM, Kaufman Z, Lelcuk S, Pappo I, Karni T, Schneebaum S, Spector R, Schindel A, Hershko D, Zilberman M, Sayfan J, Berlin Y, Hadary A, Olsha O, Paran H, Gutman M, Carmon M (2008) A prospective, randomized, controlled, multicenter study of a real-time, intraoperative probe for positive margin detection in breast-conserving surgery. Am J Surg 196(4):483–489CrossRefPubMed
4.
Zurück zum Zitat Besl PJ, McKay ND (1992) Method for registration of 3-d shapes. In: Robotics-DL tentative. International Society for Optics and Photonics, pp 586–606 Besl PJ, McKay ND (1992) Method for registration of 3-d shapes. In: Robotics-DL tentative. International Society for Optics and Photonics, pp 586–606
5.
Zurück zum Zitat Braun M, Pölcher M, Schrading S, Zivanovic O, Kowalski T, Flucke U, Leutner C, Park-Simon TW, Rudlowski C, Kuhn W, Kuhl CK (2008) Influence of preoperative mri on the surgical management of patients with operable breast cancer. Breast Cancer Res Treat 111(1):179–187CrossRefPubMed Braun M, Pölcher M, Schrading S, Zivanovic O, Kowalski T, Flucke U, Leutner C, Park-Simon TW, Rudlowski C, Kuhn W, Kuhl CK (2008) Influence of preoperative mri on the surgical management of patients with operable breast cancer. Breast Cancer Res Treat 111(1):179–187CrossRefPubMed
6.
Zurück zum Zitat Buxant F, Scuotto F, Hottat N, Noël JC, Simon P (2007) Does preoperative magnetic resonance imaging modify breast cancer surgery? Acta chirurgica Belgica 107(3):288PubMed Buxant F, Scuotto F, Hottat N, Noël JC, Simon P (2007) Does preoperative magnetic resonance imaging modify breast cancer surgery? Acta chirurgica Belgica 107(3):288PubMed
7.
Zurück zum Zitat Carter T, Tanner C, Beechey-Newman N, Barratt D, Hawkes D (2008) Mr navigated breast surgery: method and initial clinical experience. In: Medical image computing and computer-assisted intervention-MICCAI 2008. Springer, pp 356–363 Carter T, Tanner C, Beechey-Newman N, Barratt D, Hawkes D (2008) Mr navigated breast surgery: method and initial clinical experience. In: Medical image computing and computer-assisted intervention-MICCAI 2008. Springer, pp 356–363
8.
Zurück zum Zitat Conley RH, Meszoely IM, Pheiffer TS, Weis JA, Yankeelov TE, Miga MI (2014) Image to physical space registration of supine breast mri for image guided breast surgery. In: SPIE Medical Imaging. International Society for Optics and Photonics, p 90362N Conley RH, Meszoely IM, Pheiffer TS, Weis JA, Yankeelov TE, Miga MI (2014) Image to physical space registration of supine breast mri for image guided breast surgery. In: SPIE Medical Imaging. International Society for Optics and Photonics, p 90362N
9.
Zurück zum Zitat Davis KM, Hsu CH, Bouton ME, Wilhelmson KL, Komenaka IK (2011) Intraoperative ultrasound can decrease the re-excision lumpectomy rate in patients with palpable breast cancers. Am Surg 77(6):720–725PubMed Davis KM, Hsu CH, Bouton ME, Wilhelmson KL, Komenaka IK (2011) Intraoperative ultrasound can decrease the re-excision lumpectomy rate in patients with palpable breast cancers. Am Surg 77(6):720–725PubMed
10.
Zurück zum Zitat Ebrahimi M, Siegler P, Modhafar A, Holloway CM, Plewes DB, Martel AL (2014) Using surface markers for mri guided breast conserving surgery: a feasibility survey. Phys Med Biol 59(7):1589CrossRefPubMed Ebrahimi M, Siegler P, Modhafar A, Holloway CM, Plewes DB, Martel AL (2014) Using surface markers for mri guided breast conserving surgery: a feasibility survey. Phys Med Biol 59(7):1589CrossRefPubMed
11.
Zurück zum Zitat Fancher TT, Palesty JA, Thomas R, Healy T, Fancher JM, Ng C, Dudrick SJ (2009) A woman’s influence to choose mastectomy as treatment for breast cancer. J Surg Res 153(1):128–131CrossRefPubMed Fancher TT, Palesty JA, Thomas R, Healy T, Fancher JM, Ng C, Dudrick SJ (2009) A woman’s influence to choose mastectomy as treatment for breast cancer. J Surg Res 153(1):128–131CrossRefPubMed
12.
Zurück zum Zitat Fisher B, Bauer M, Margolese R, Poisson R, Pilch Y, Redmond C, Fisher E, Wolmark N, Deutsch M, Montague E, Saffer E, Wickerham L, Lerner H, Glass A, Shibata H, Deckers P, Ketcham A, Oishi R, Russel I (1985) Five-year results of a randomized clinical trial comparing total mastectomy and segmental mastectomy with or without radiation in the treatment of breast cancer. N Engl J Med 312(11):665–673CrossRefPubMed Fisher B, Bauer M, Margolese R, Poisson R, Pilch Y, Redmond C, Fisher E, Wolmark N, Deutsch M, Montague E, Saffer E, Wickerham L, Lerner H, Glass A, Shibata H, Deckers P, Ketcham A, Oishi R, Russel I (1985) Five-year results of a randomized clinical trial comparing total mastectomy and segmental mastectomy with or without radiation in the treatment of breast cancer. N Engl J Med 312(11):665–673CrossRefPubMed
13.
Zurück zum Zitat Glossop ND (2009) Advantages of optical compared with electromagnetic tracking. J Bone Jt Surg 91(Supplement 1):23–28CrossRef Glossop ND (2009) Advantages of optical compared with electromagnetic tracking. J Bone Jt Surg 91(Supplement 1):23–28CrossRef
14.
Zurück zum Zitat Han L, Hipwell J, Eiben B, Barratt D, Modat M, Ourselin S, Hawkes D (2014) A nonlinear biomechanical model based registration method for aligning prone and supine mr breast images. Med Imaging IEEE Trans 33(3):682–694CrossRef Han L, Hipwell J, Eiben B, Barratt D, Modat M, Ourselin S, Hawkes D (2014) A nonlinear biomechanical model based registration method for aligning prone and supine mr breast images. Med Imaging IEEE Trans 33(3):682–694CrossRef
15.
Zurück zum Zitat Jemal A, Bray F, Center MM, Ferlay J, Ward E, Forman D (2011) Global cancer statistics. CA: Cancer J Clinicians 61(2):69–90 Jemal A, Bray F, Center MM, Ferlay J, Ward E, Forman D (2011) Global cancer statistics. CA: Cancer J Clinicians 61(2):69–90
16.
Zurück zum Zitat Landercasper J, Whitacre E, Degnim AC, Al-Hamadani M (2014) Reasons for re-excision after lumpectomy for breast cancer: insight from the american society of breast surgeons masterysm database. Ann Surg Oncol 21(10):3185–3191CrossRefPubMed Landercasper J, Whitacre E, Degnim AC, Al-Hamadani M (2014) Reasons for re-excision after lumpectomy for breast cancer: insight from the american society of breast surgeons masterysm database. Ann Surg Oncol 21(10):3185–3191CrossRefPubMed
17.
Zurück zum Zitat Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3d surface construction algorithm. In: ACM siggraph computer graphics, vol 21. ACM, pp 163–169 Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3d surface construction algorithm. In: ACM siggraph computer graphics, vol 21. ACM, pp 163–169
18.
Zurück zum Zitat Mortensen EN, Barrett WA (1995) Intelligent scissors for image composition. In: Proceedings of the 22nd annual conference on computer graphics and interactive techniques, pp 191–198 Mortensen EN, Barrett WA (1995) Intelligent scissors for image composition. In: Proceedings of the 22nd annual conference on computer graphics and interactive techniques, pp 191–198
19.
Zurück zum Zitat Muratore DM, Galloway RL Jr (2001) Beam calibration without a phantom for creating a 3-d freehand ultrasound system. Ultrasound Med Biol 27(11):1557–1566CrossRefPubMed Muratore DM, Galloway RL Jr (2001) Beam calibration without a phantom for creating a 3-d freehand ultrasound system. Ultrasound Med Biol 27(11):1557–1566CrossRefPubMed
20.
Zurück zum Zitat Pallone MJ, Poplack SP, Avutu HBR, Paulsen KD, Barth Jr RJ (2014) Supine breast mri and 3d optical scanning: a novel approach to improve tumor localization for breast conserving surgery. Ann Surg Oncol 21(7):2203–2208 Pallone MJ, Poplack SP, Avutu HBR, Paulsen KD, Barth Jr RJ (2014) Supine breast mri and 3d optical scanning: a novel approach to improve tumor localization for breast conserving surgery. Ann Surg Oncol 21(7):2203–2208
21.
Zurück zum Zitat Pheiffer TS, Simpson AL, Lennon B, Thompson RC, Miga MI (2012) Design and evaluation of an optically-tracked single-ccd laser range scanner. Med Phys 39(2):636–642PubMedCentralCrossRefPubMed Pheiffer TS, Simpson AL, Lennon B, Thompson RC, Miga MI (2012) Design and evaluation of an optically-tracked single-ccd laser range scanner. Med Phys 39(2):636–642PubMedCentralCrossRefPubMed
22.
Zurück zum Zitat Pheiffer TS, Thompson RC, Rucker DC, Simpson AL, Miga MI (2014) Model-based correction of tissue compression for tracked ultrasound in soft tissue image-guided surgery. Ultrasound Med Biol 40(4):788–803PubMedCentralCrossRefPubMed Pheiffer TS, Thompson RC, Rucker DC, Simpson AL, Miga MI (2014) Model-based correction of tissue compression for tracked ultrasound in soft tissue image-guided surgery. Ultrasound Med Biol 40(4):788–803PubMedCentralCrossRefPubMed
23.
Zurück zum Zitat Pleijhuis RG, Graafland M, de Vries J, Bart J, de Jong JS, van Dam GM (2009) Obtaining adequate surgical margins in breast-conserving therapy for patients with early-stage breast cancer: current modalities and future directions. Ann Surg Oncol 16(10):2717–2730PubMedCentralCrossRefPubMed Pleijhuis RG, Graafland M, de Vries J, Bart J, de Jong JS, van Dam GM (2009) Obtaining adequate surgical margins in breast-conserving therapy for patients with early-stage breast cancer: current modalities and future directions. Ann Surg Oncol 16(10):2717–2730PubMedCentralCrossRefPubMed
24.
Zurück zum Zitat Rucker D, Wu Y, Clements L, Ondrake J, Pheiffer T, Simpson A, Jarnagin W, Miga M (2014) A mechanics-based nonrigid registration method for liver surgery using sparse intraoperative data. Med Imaging IEEE Trans 33(1):147–158CrossRef Rucker D, Wu Y, Clements L, Ondrake J, Pheiffer T, Simpson A, Jarnagin W, Miga M (2014) A mechanics-based nonrigid registration method for liver surgery using sparse intraoperative data. Med Imaging IEEE Trans 33(1):147–158CrossRef
25.
Zurück zum Zitat Siegler P, Holloway C, Causer P, Thevathasan G, Plewes DB (2011) Supine breast mri. J Magn Reson Imaging 34(5):1212–1217CrossRefPubMed Siegler P, Holloway C, Causer P, Thevathasan G, Plewes DB (2011) Supine breast mri. J Magn Reson Imaging 34(5):1212–1217CrossRefPubMed
26.
Zurück zum Zitat Sonka M, Fitzpatrick JM (2000) Handbook of medical imaging(volume 2, medical image processing and analysis). SPIE- The International Society for Optical Engineering Sonka M, Fitzpatrick JM (2000) Handbook of medical imaging(volume 2, medical image processing and analysis). SPIE- The International Society for Optical Engineering
27.
Zurück zum Zitat Sullivan JM Jr, Charron G, Paulsen KD (1997) A three-dimensional mesh generator for arbitrary multiple material domains. Finite Elem Anal Des 25(3):219–241CrossRef Sullivan JM Jr, Charron G, Paulsen KD (1997) A three-dimensional mesh generator for arbitrary multiple material domains. Finite Elem Anal Des 25(3):219–241CrossRef
28.
Zurück zum Zitat Tafra L, Fine R, Whitworth P, Berry M, Woods J, Ekbom G, Gass J, Beitsch P, Dodge D, Han L, Potruch T, Francescatti D, Oetting L, Smith JS, Snider H, Kleban D, Chagpar A, Akbari S (2006) Prospective randomized study comparing cryo-assisted and needle-wire localization of ultrasound-visible breast tumors. Am J Surg 192(4):462–470CrossRefPubMed Tafra L, Fine R, Whitworth P, Berry M, Woods J, Ekbom G, Gass J, Beitsch P, Dodge D, Han L, Potruch T, Francescatti D, Oetting L, Smith JS, Snider H, Kleban D, Chagpar A, Akbari S (2006) Prospective randomized study comparing cryo-assisted and needle-wire localization of ultrasound-visible breast tumors. Am J Surg 192(4):462–470CrossRefPubMed
29.
Zurück zum Zitat Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G (2006) User-guided 3d active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31(3):1116–1128CrossRefPubMed Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G (2006) User-guided 3d active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31(3):1116–1128CrossRefPubMed
Metadaten
Titel
Realization of a biomechanical model-assisted image guidance system for breast cancer surgery using supine MRI
verfasst von
Rebekah H. Conley
Ingrid M. Meszoely
Jared A. Weis
Thomas S. Pheiffer
Lori R. Arlinghaus
Thomas E. Yankeelov
Michael I. Miga
Publikationsdatum
01.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 12/2015
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1235-9

Weitere Artikel der Ausgabe 12/2015

International Journal of Computer Assisted Radiology and Surgery 12/2015 Zur Ausgabe

Premium Partner