Abstract

Purpose

This research is situated in the context of breast cancer detection where the standard procedure is the succession of an initial mammography (MX) examination and a supplementary ultrasound (US) scan. One major difficulty of this procedure results from the fact that breast geometry changes between both examinations due to different patient’s positions. The proposed system facilitates this combined examination by keeping the breast geometry and by adding a US probe guidance robot to the mammography system.

Methods

A comanipulation system is set up where the robot and user simultaneously manipulate the probe toward the target previously localized in MX images. Calibration procedures and robot control are detailed.

Results

A test protocol was presented to conduct two tests that are both related to the medical application. The first tests aim at evaluating robot guidance for localizing a lesion which was previously defined in the X-ray images. The second tests aim at quantifying robot influence when scanning a target lesion. The studied task consists of a pointing/scanning exercise, where the US beam intersects a breast lesion.

Conclusions

The experiments show a significant increase in examination quality when using robot guidance as compared to the nonassisted examination.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Berg WA, Blume JD, Cormack JB, Mendelson EB, Lehrer D, Bhm-Vlez M, Pisano ED, Jong RA, Evans WP, Morton MJ, Mahoney MC, Hovanessian Larsen L, Barr RG, Farria DM, Marques HS, Boparai K (2008) Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer. J Am Med Assoc (JAMA) 299(18):2151–2163CrossRef Berg WA, Blume JD, Cormack JB, Mendelson EB, Lehrer D, Bhm-Vlez M, Pisano ED, Jong RA, Evans WP, Morton MJ, Mahoney MC, Hovanessian Larsen L, Barr RG, Farria DM, Marques HS, Boparai K (2008) Combined screening with ultrasound and mammography vs mammography alone in women at elevated risk of breast cancer. J Am Med Assoc (JAMA) 299(18):2151–2163CrossRef
2.
Zurück zum Zitat Besl PJ, McKay HD (1992) A method for registration of 3-d shapes. IEEE Trans Pattern Anal Mach 14:227–241CrossRef Besl PJ, McKay HD (1992) A method for registration of 3-d shapes. IEEE Trans Pattern Anal Mach 14:227–241CrossRef
3.
Zurück zum Zitat Bonneau E, Taha F, Gravez P, Lamy S (2004) Surgicobot: surgical gesture assistance cobot for maxillo-facial interventions. Perspect Image-Guided Surg 1:353–360CrossRef Bonneau E, Taha F, Gravez P, Lamy S (2004) Surgicobot: surgical gesture assistance cobot for maxillo-facial interventions. Perspect Image-Guided Surg 1:353–360CrossRef
4.
Zurück zum Zitat Booi RC, Kruecher JF, Goodsitt MM, O’Donnell M, Kapur A, LeCarpentier GL, Roubidoux MA, Fowlkes JB, Carson PL (2007) Evaluating thin compression paddles for mammographically compatible ultrasound. Ultrasound Med Biol 33(3):472–482PubMedCentralCrossRefPubMed Booi RC, Kruecher JF, Goodsitt MM, O’Donnell M, Kapur A, LeCarpentier GL, Roubidoux MA, Fowlkes JB, Carson PL (2007) Evaluating thin compression paddles for mammographically compatible ultrasound. Ultrasound Med Biol 33(3):472–482PubMedCentralCrossRefPubMed
5.
Zurück zum Zitat Buchberger W, Niehoff A, Obrist P, DeKoekkoek-Doll P, Duenser M (2000) Clinically and mammographically occult breast lesions: detection and classification with high-resolution sonography. Semin Ultrasound CT MRI 21(4):325–336CrossRef Buchberger W, Niehoff A, Obrist P, DeKoekkoek-Doll P, Duenser M (2000) Clinically and mammographically occult breast lesions: detection and classification with high-resolution sonography. Semin Ultrasound CT MRI 21(4):325–336CrossRef
6.
Zurück zum Zitat Conway W, Hayes C, Brewer W (1991) Occult breast masses: use of a mammographic localizing grid for us evaluation. Radiology 181(1):143–146CrossRefPubMed Conway W, Hayes C, Brewer W (1991) Occult breast masses: use of a mammographic localizing grid for us evaluation. Radiology 181(1):143–146CrossRefPubMed
7.
Zurück zum Zitat Davies B, Fan K, Hibberd R, Jakopec M, Harris S (1997) A mechatronic based robotic system for knee surgery. In: IASTED International Conference on Intelligent Information Systems, pp. 48–52 Davies B, Fan K, Hibberd R, Jakopec M, Harris S (1997) A mechatronic based robotic system for knee surgery. In: IASTED International Conference on Intelligent Information Systems, pp. 48–52
8.
Zurück zum Zitat Dombre E, Khalil W (2007) Robot Manipulators: Modeling, Performance Analysis and Control. Control Systems, Robotics and Manufacturing Series. Wiley-ISTE Dombre E, Khalil W (2007) Robot Manipulators: Modeling, Performance Analysis and Control. Control Systems, Robotics and Manufacturing Series. Wiley-ISTE
9.
Zurück zum Zitat D’Orsi C, Bassett L, Berg W (2003) Breast imaging reporting and data system: ACR BI-RADS-Mammography, 4th edn. American College of Radiology, Reston D’Orsi C, Bassett L, Berg W (2003) Breast imaging reporting and data system: ACR BI-RADS-Mammography, 4th edn. American College of Radiology, Reston
10.
Zurück zum Zitat Francoise V, Sahbani A, Morel G (2011) A comanipulation device for orthopedic surgery that generates geometrical constraints with real-time registration on moving bones. In: Robotics and Biomimetics (ROBIO), 2011 IEEE International Conference on, pp. 38–43 Francoise V, Sahbani A, Morel G (2011) A comanipulation device for orthopedic surgery that generates geometrical constraints with real-time registration on moving bones. In: Robotics and Biomimetics (ROBIO), 2011 IEEE International Conference on, pp. 38–43
11.
Zurück zum Zitat Gordon P, Goldenberg S (1995) Malignant breast masses detected only by ultrasound: a retrospective review. Cancer 76(4):626–630CrossRefPubMed Gordon P, Goldenberg S (1995) Malignant breast masses detected only by ultrasound: a retrospective review. Cancer 76(4):626–630CrossRefPubMed
12.
Zurück zum Zitat Harvey JA, Bovbjerg VE (2004) Quantitative assessment of mammographic breast density: relationship with breast cancer risk1. Radiology 230(1):29–41CrossRefPubMed Harvey JA, Bovbjerg VE (2004) Quantitative assessment of mammographic breast density: relationship with breast cancer risk1. Radiology 230(1):29–41CrossRefPubMed
13.
Zurück zum Zitat Kaplan S (2001) Clinical utility of bilateral whole breast us in the evaluation of women with dense breast tissue. Radiology 221(3):641–649 Kaplan S (2001) Clinical utility of bilateral whole breast us in the evaluation of women with dense breast tissue. Radiology 221(3):641–649
14.
Zurück zum Zitat Kapur A, Carson P, Eberhard J, Goodsitt M, Thomenius K, Lokhandwalla M, Buckley D, Roubidoux M, Helvie M, Booi R, LeCarpentier G, Erkamp R, Chan H, Fowlkes J, Thomas J, Landberg C (2004) Combination of digital mammography with semi-automated 3d breast ultrasound. Technol Cancer Res Treat 3(4):325–334PubMedCentralCrossRefPubMed Kapur A, Carson P, Eberhard J, Goodsitt M, Thomenius K, Lokhandwalla M, Buckley D, Roubidoux M, Helvie M, Booi R, LeCarpentier G, Erkamp R, Chan H, Fowlkes J, Thomas J, Landberg C (2004) Combination of digital mammography with semi-automated 3d breast ultrasound. Technol Cancer Res Treat 3(4):325–334PubMedCentralCrossRefPubMed
15.
Zurück zum Zitat Kolb TM, Lichy J, Newhouse JH (2002) Comparison of the performance of screening mammography, physical examination, and breast us and evaluation of factors that influence them: An analysis of 27,825 patient evaluations 1. Radiology 225(1):165–175CrossRefPubMed Kolb TM, Lichy J, Newhouse JH (2002) Comparison of the performance of screening mammography, physical examination, and breast us and evaluation of factors that influence them: An analysis of 27,825 patient evaluations 1. Radiology 225(1):165–175CrossRefPubMed
16.
Zurück zum Zitat Kragic D, Marayong P, Li M, Okamura AM, Hager GD (2005) Human-machine collaborative systems for microsurgical applications. Int J Robot Res 24(9):731–741CrossRef Kragic D, Marayong P, Li M, Okamura AM, Hager GD (2005) Human-machine collaborative systems for microsurgical applications. Int J Robot Res 24(9):731–741CrossRef
17.
Zurück zum Zitat Leconte I, Feger C, Galant C, Berlire M, Berg B, D’Hoore W, Maldague B (2003) Mammography and subsequent whole-breast sonography of nonpalpable breast cancers: the importance of radiologic breast density. Am J Roentgenol 180(6):1675–1679CrossRef Leconte I, Feger C, Galant C, Berlire M, Berg B, D’Hoore W, Maldague B (2003) Mammography and subsequent whole-breast sonography of nonpalpable breast cancers: the importance of radiologic breast density. Am J Roentgenol 180(6):1675–1679CrossRef
18.
Zurück zum Zitat Poquet C, Vitrani MA, Morel G (2014) Proximal comanipulation of a minimally invasive surgery instrument to emulate distal forces. In: CRAS 2014, 4th Joint Workshop on New Technologies for Computer/Robot Assisted Surgery, pp. 48–51 Poquet C, Vitrani MA, Morel G (2014) Proximal comanipulation of a minimally invasive surgery instrument to emulate distal forces. In: CRAS 2014, 4th Joint Workshop on New Technologies for Computer/Robot Assisted Surgery, pp. 48–51
19.
Zurück zum Zitat Schneider O, Troccaz J (2001) A six degree of freedom passive arm with dynamic constraints (padyc) for cardiac surgery application: preliminary experiments. Comput Aided Surg 6:340–351 (special issue on medical robotics)CrossRefPubMed Schneider O, Troccaz J (2001) A six degree of freedom passive arm with dynamic constraints (padyc) for cardiac surgery application: preliminary experiments. Comput Aided Surg 6:340–351 (special issue on medical robotics)CrossRefPubMed
20.
Zurück zum Zitat Schneider O, Troccaz J, Chavanon O, Blin D (2000) Padyc: a synergistic robot for cardiac puncturing. In: IEEE International Conference on Robotics and Automation (ICRA), pp. 2883–2888 Schneider O, Troccaz J, Chavanon O, Blin D (2000) Padyc: a synergistic robot for cardiac puncturing. In: IEEE International Conference on Robotics and Automation (ICRA), pp. 2883–2888
21.
Zurück zum Zitat Vitrani MA, Morel G (2008) Hand-eye self-calibration of an ultrasound image-based robotic system. In: IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 1179–1185 Vitrani MA, Morel G (2008) Hand-eye self-calibration of an ultrasound image-based robotic system. In: IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), pp. 1179–1185
Metadaten
Titel
Robot guidance of an ultrasound probe toward a 3D region of interest detected through X-ray mammography
verfasst von
Marie-Aude Vitrani
Anja Marx
Rǎzvan Iordache
Serge Muller
Guillaume Morel
Publikationsdatum
01.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 12/2015
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1244-8

Weitere Artikel der Ausgabe 12/2015

International Journal of Computer Assisted Radiology and Surgery 12/2015 Zur Ausgabe

Premium Partner