Skip to main content

2018 | OriginalPaper | Buchkapitel

Retina Tomography and Optical Coherence Tomography in Eye Diagnostic System

verfasst von : Maciej Szymkowski, Emil Saeed, Khalid Saeed

Erschienen in: Advanced Computing and Systems for Security

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Eye diagnostic, two-step method based on retina color image and Optical Coherence Tomography is presented in this paper. A new robust algorithm, by which various eye diseases can be diagnosed, was implemented as an essential part of the work. The approach comprises two steps. The first one deals with the analysis of retina color image. In this stage, an algorithm was implemented to especially search hard exudates. If the algorithm returns positive, it means at least one hard exudate was found. Moreover, it may return hesitant results in the case of changes that look like hard exudates. During the second step, additional analysis of Optical Coherence Tomography image is done. In this stage, the algorithm is looking for confirmation of hard exudates, which were found during the first step. The authors’ approach gives more confidence in the cases of small exudates or initial stages for eye diseases.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Eadgahi, M.G.F., Pourreza, H.: Localization of hard exudates in retinal fundus image by mathematical morphology operations. J. Theor. Phys. Cryptogr. 1 (2012) Eadgahi, M.G.F., Pourreza, H.: Localization of hard exudates in retinal fundus image by mathematical morphology operations. J. Theor. Phys. Cryptogr. 1 (2012)
2.
Zurück zum Zitat Jaafar, H.F., Nandi, A.K., Al-Nuaimy, W.: Automated detection and grading of hard exudates from retinal fundus images. In: 19th European Signal Processing Conference—EUSIPCO, pp. 66–70. (2011) Jaafar, H.F., Nandi, A.K., Al-Nuaimy, W.: Automated detection and grading of hard exudates from retinal fundus images. In: 19th European Signal Processing Conference—EUSIPCO, pp. 66–70. (2011)
3.
Zurück zum Zitat Jaya Kumari, C., Maruthi, R.: Detection of hard exudates in color fundus images of the human retina. In: International Conference on Communication Technology and System Design, Procedia Engineering, pp. 297–302. (2011) Jaya Kumari, C., Maruthi, R.: Detection of hard exudates in color fundus images of the human retina. In: International Conference on Communication Technology and System Design, Procedia Engineering, pp. 297–302. (2011)
4…..
Zurück zum Zitat Rokade, P., Manza, R.: Automatic detection of hard exudates in retinal images using haar wavelet transform. Int. J. Appl. Innov. Eng. Manag. 4(5) (2015) Rokade, P., Manza, R.: Automatic detection of hard exudates in retinal images using haar wavelet transform. Int. J. Appl. Innov. Eng. Manag. 4(5) (2015)
5.
Zurück zum Zitat Kekre, H., Sarode, T., Parkar, T.: Hybrid approach for detection of hard exudates. Int. J. Adv. Comput. Sci. Appl. 4 (2013) Kekre, H., Sarode, T., Parkar, T.: Hybrid approach for detection of hard exudates. Int. J. Adv. Comput. Sci. Appl. 4 (2013)
6.
Zurück zum Zitat Stankiewicz, A., Marciniak, T., Dąbrowski, A., Stopa, M., Rakowicz, P., Marciniak, E.: Denoising methods for improving automatic segmentation in OCT images of human eye. Bull. Pol. Acad. Sci. Tech. Sci. 1 (2017) Stankiewicz, A., Marciniak, T., Dąbrowski, A., Stopa, M., Rakowicz, P., Marciniak, E.: Denoising methods for improving automatic segmentation in OCT images of human eye. Bull. Pol. Acad. Sci. Tech. Sci. 1 (2017)
7.
Zurück zum Zitat Turchin, I., Sergeeva, E., Dolin, L., Kamensky, V., Shakhova, N., Richards-Kortum, R.: Novel algorithm of processing optical coherence tomography images for differentiation of biological tissue pathologies. J. Biomed. Opt. 10(6) (2005)CrossRef Turchin, I., Sergeeva, E., Dolin, L., Kamensky, V., Shakhova, N., Richards-Kortum, R.: Novel algorithm of processing optical coherence tomography images for differentiation of biological tissue pathologies. J. Biomed. Opt. 10(6) (2005)CrossRef
8.
Zurück zum Zitat Somfai, G., Tatrai, E., Laurik, L., Varga, B., Olvedy, V., Smiddy, W., Tchitnga, R., Somogyi, A., DeBuc, D.: Fractal-based analysis of optical coherence tomography data to quantify retinal tissue damage. BMC Bioinform. 15, 295 (2014)CrossRef Somfai, G., Tatrai, E., Laurik, L., Varga, B., Olvedy, V., Smiddy, W., Tchitnga, R., Somogyi, A., DeBuc, D.: Fractal-based analysis of optical coherence tomography data to quantify retinal tissue damage. BMC Bioinform. 15, 295 (2014)CrossRef
9.
Zurück zum Zitat Świebocka-Więk, J.: The detections of the retina’s lesions in Optical Coherence Tomography (OCT). In: CITCEP—Proceedings of the Congress on Information Technology, Computational and Experimental Physics, Kraków, Poland, 18–20 December. (2015) Świebocka-Więk, J.: The detections of the retina’s lesions in Optical Coherence Tomography (OCT). In: CITCEP—Proceedings of the Congress on Information Technology, Computational and Experimental Physics, Kraków, Poland, 18–20 December. (2015)
10.
Zurück zum Zitat Srinivasan, P., Kim, L., Mettu, P.S., Cousins, S.W., Comer, G.M., Izatt, J.A., Farsiu, S.: Fully automated detection of diabetic macular edema and dry age-related macular degeneration from optical coherence tomography images. Biomed. Opt. Express. 5 (2014)CrossRef Srinivasan, P., Kim, L., Mettu, P.S., Cousins, S.W., Comer, G.M., Izatt, J.A., Farsiu, S.: Fully automated detection of diabetic macular edema and dry age-related macular degeneration from optical coherence tomography images. Biomed. Opt. Express. 5 (2014)CrossRef
11.
Zurück zum Zitat Chaki, N., Hossain Shaikh, S., Saeed, K.: Studies in computational intelligence In: Exploring Image Binarization Techniques, vol. 560. Springer India, (2014). ISBN: 978-81322-1906-4CrossRef Chaki, N., Hossain Shaikh, S., Saeed, K.: Studies in computational intelligence In: Exploring Image Binarization Techniques, vol. 560. Springer India, (2014). ISBN: 978-81322-1906-4CrossRef
Metadaten
Titel
Retina Tomography and Optical Coherence Tomography in Eye Diagnostic System
verfasst von
Maciej Szymkowski
Emil Saeed
Khalid Saeed
Copyright-Jahr
2018
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-8180-4_3

Premium Partner