Skip to main content

2021 | OriginalPaper | Buchkapitel

Seismic Response Reduction of RC Frame Staging in Elevated Water Tank

verfasst von : Sakshi A. Manchalwar, V. Verghese

Erschienen in: Advances in Civil Engineering and Infrastructural Development

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Elevated water tank with frame staging is mostly used in India and due to its requirement after earthquake, it is considered as an important structure. Thus, it is required to control the seismic response of tank staging to minimize damages. In this work, the effectiveness of lead rubber bearing (LRB) and X-plate damper (XPD) in seismic response control of staging is investigated. Initially, two types of frame staging are considered for the same capacity of the tank and from nonlinear static analysis, best-suited staging is identified. After this, LRB and XPD are installed separately and to check the effectiveness of these devices, nonlinear time history analysis has been performed for four different earthquake records. It is observed that due to these control devices, seismic responses are significantly reduced.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Shenton HW, Hampton FP (1999) Seismic response of isolated elevated water tanks. J Struct Eng 125(9):965–976CrossRef Shenton HW, Hampton FP (1999) Seismic response of isolated elevated water tanks. J Struct Eng 125(9):965–976CrossRef
2.
Zurück zum Zitat Panchal VR, Jangid RS (2008) Variable friction pendulum system for seismic isolation of liquid storage tanks. Nuclear Eng Des 238:1304–1315CrossRef Panchal VR, Jangid RS (2008) Variable friction pendulum system for seismic isolation of liquid storage tanks. Nuclear Eng Des 238:1304–1315CrossRef
3.
Zurück zum Zitat Shekari MR, Khaji N, Ahmadi MT (2010) On the seismic behavior of cylindrical base-isolated liquid storage tanks excited by long-period ground motions. Soil Dyn Earthquake Eng 30:968–980CrossRef Shekari MR, Khaji N, Ahmadi MT (2010) On the seismic behavior of cylindrical base-isolated liquid storage tanks excited by long-period ground motions. Soil Dyn Earthquake Eng 30:968–980CrossRef
4.
Zurück zum Zitat Abal E, Uckan E (2010) Parametric analysis of liquid storage tanks base isolated by curved surface sliding bearings. Soil Dyn Earthquake Eng 30:21–31CrossRef Abal E, Uckan E (2010) Parametric analysis of liquid storage tanks base isolated by curved surface sliding bearings. Soil Dyn Earthquake Eng 30:21–31CrossRef
5.
Zurück zum Zitat Soni DP, Mistry BB, Panchal VR (2011) Double variable frequency pendulum isolator for seismic isolation of liquid storage tanks. Nuclear Eng Des 241:700–713CrossRef Soni DP, Mistry BB, Panchal VR (2011) Double variable frequency pendulum isolator for seismic isolation of liquid storage tanks. Nuclear Eng Des 241:700–713CrossRef
6.
Zurück zum Zitat Seleemah AA, Sharkawy ME (2011) Seismic response of base isolated liquid storage ground tanks. Ain Shams Eng J 2:33–42CrossRef Seleemah AA, Sharkawy ME (2011) Seismic response of base isolated liquid storage ground tanks. Ain Shams Eng J 2:33–42CrossRef
7.
Zurück zum Zitat Panchal VR, Jangid RS (2011) Seismic response of liquid storage steel tanks with variable frequency pendulum isolator. KSCE J Civil Eng 15(6):1041–1055CrossRef Panchal VR, Jangid RS (2011) Seismic response of liquid storage steel tanks with variable frequency pendulum isolator. KSCE J Civil Eng 15(6):1041–1055CrossRef
8.
Zurück zum Zitat SAP (2000) Integrated software for structural analysis and design, technical reference manual. Computers and Structures, Inc SAP (2000) Integrated software for structural analysis and design, technical reference manual. Computers and Structures, Inc
9.
Zurück zum Zitat Kelly JM, Skinner RI, Heine AJ (1972) Mechanisms of energy absorption in special devices for use in earthquake resistant structures. Bull NZ Soc Earthquake Eng 5(3):63–88 Kelly JM, Skinner RI, Heine AJ (1972) Mechanisms of energy absorption in special devices for use in earthquake resistant structures. Bull NZ Soc Earthquake Eng 5(3):63–88
10.
Zurück zum Zitat Skinner RI, Kelly JM, Heine AJ (1974) Hysteretic dampers for earthquake resistant structures. Earthquake Eng Struct Dyn 3(3):287–296CrossRef Skinner RI, Kelly JM, Heine AJ (1974) Hysteretic dampers for earthquake resistant structures. Earthquake Eng Struct Dyn 3(3):287–296CrossRef
11.
Zurück zum Zitat Tyler RG (1978) Tapered steel energy dissipators for earthquake resistant structures. Bull NZ Nat Soc Earthquake Eng 11(4):282–294 Tyler RG (1978) Tapered steel energy dissipators for earthquake resistant structures. Bull NZ Nat Soc Earthquake Eng 11(4):282–294
12.
Zurück zum Zitat Bergman S, Goel S (1987) Evaluation of cyclic testing of steel-plate devices for added damping and stiffness. Report UMCE 87–10, Department of Civil Engineering, University of Michigan Bergman S, Goel S (1987) Evaluation of cyclic testing of steel-plate devices for added damping and stiffness. Report UMCE 87–10, Department of Civil Engineering, University of Michigan
13.
Zurück zum Zitat Whittaker AS, Bertero VV, Alonso LJ, Thompson CL (1989) Earthquake simulator testing of steel plate added damping and stiffness elements. Report UCB/EERC-89/02, Earthquake Engineering Research Center, University of California at Berkeley Whittaker AS, Bertero VV, Alonso LJ, Thompson CL (1989) Earthquake simulator testing of steel plate added damping and stiffness elements. Report UCB/EERC-89/02, Earthquake Engineering Research Center, University of California at Berkeley
14.
Zurück zum Zitat Whittaker AS, Bertero VV, Thompson CL, Aionso LJ (1991) Seismic testing of steel plate energy dissipation devices. Earthquake Spectra 7(4):563–606CrossRef Whittaker AS, Bertero VV, Thompson CL, Aionso LJ (1991) Seismic testing of steel plate energy dissipation devices. Earthquake Spectra 7(4):563–606CrossRef
15.
Zurück zum Zitat Martinez-Romero E (1993) Experiences on the use of supplementary energy dissipators on building structures. Earthquake Spectra 9(3):581–626CrossRef Martinez-Romero E (1993) Experiences on the use of supplementary energy dissipators on building structures. Earthquake Spectra 9(3):581–626CrossRef
16.
Zurück zum Zitat Perry CL, Fierro EA, Sedarat H, Scholl RE (1993) Seismic upgrade in San Francisco using energy dissipation devices. Earthquake Spectra 9(3):559–579CrossRef Perry CL, Fierro EA, Sedarat H, Scholl RE (1993) Seismic upgrade in San Francisco using energy dissipation devices. Earthquake Spectra 9(3):559–579CrossRef
17.
Zurück zum Zitat Manchalwar AA, Bakre SV (2016) Performance of RC structures equipped with steel and aluminium X-plate dampers. J Inst Eng India Ser A 97(4):415–425CrossRef Manchalwar AA, Bakre SV (2016) Performance of RC structures equipped with steel and aluminium X-plate dampers. J Inst Eng India Ser A 97(4):415–425CrossRef
18.
Zurück zum Zitat Komur MA (2015) Soft-story effects on the behavior of fixed-base and LRB base-isolated reinforced concrete buildings. Arab J Sci Eng 41(2):381–391CrossRef Komur MA (2015) Soft-story effects on the behavior of fixed-base and LRB base-isolated reinforced concrete buildings. Arab J Sci Eng 41(2):381–391CrossRef
19.
Zurück zum Zitat IS 1893 Part 2 (2014) Criteria for earthquake resistant design of structures part 2 liquid retaining tanks. Bureau of Indian Standard, New Delhi, India IS 1893 Part 2 (2014) Criteria for earthquake resistant design of structures part 2 liquid retaining tanks. Bureau of Indian Standard, New Delhi, India
20.
Zurück zum Zitat IS 456 (2000) Plain and reinforced concrete-code of practice (fourth revision). BIS, New Delhi, India IS 456 (2000) Plain and reinforced concrete-code of practice (fourth revision). BIS, New Delhi, India
21.
Zurück zum Zitat Mukherjee S, Gupta VK (2002) Wavelet-based generation of spectrum-compatible time histories. Soil Dyn Earthquake Eng 22:799–804CrossRef Mukherjee S, Gupta VK (2002) Wavelet-based generation of spectrum-compatible time histories. Soil Dyn Earthquake Eng 22:799–804CrossRef
22.
Zurück zum Zitat IS 1893 Part 1 (2016) Criteria for earthquake resistant design of structures part 1 general provisions and buildings. Bureau of Indian Standard, New Delhi, India IS 1893 Part 1 (2016) Criteria for earthquake resistant design of structures part 1 general provisions and buildings. Bureau of Indian Standard, New Delhi, India
Metadaten
Titel
Seismic Response Reduction of RC Frame Staging in Elevated Water Tank
verfasst von
Sakshi A. Manchalwar
V. Verghese
Copyright-Jahr
2021
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-15-6463-5_7

    Premium Partner