Skip to main content

2019 | OriginalPaper | Buchkapitel

Sophisticated Hydrodynamic Simulation of Pulmonary Circulation for the Preclinical Examination of Right Heart Circulatory Assist Device

verfasst von : Yusuke Tsuboko, Yasuyuki Shiraishi, Akihiro Yamada, Kiyotaka Iwasaki, Mitsuo Umezu, Tomoyuki Yambe

Erschienen in: World Congress on Medical Physics and Biomedical Engineering 2018

Verlag: Springer Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

To evaluate systemic circulatory support devices such as left ventricular assist system, surgical heart valve prosthesis, and transcatheter aortic valve, various in vitro hydrodynamic tests have been performed. As these devices are being applied to the pulmonary circulatory support in recent years, novel evaluation platform for right heart support is increasingly demanded. This study aims to develop a pulmonary mechanical circulatory simulation system to assess the hydrodynamic performance of newly designed artificial cardiovascular devices. For the construction of the system, we developed the pneumatically-driven polymer right atrial and ventricular models with the pulmonary arterial valve chamber, silicone-made peripheral pulmonary artery model, and a venous reservoir. A woven polyester vascular graft and commercially available mechanical bileaflet valve were installed into the valve chamber. Then, the right ventricular pressure and pulmonary arterial pressure were regulated by the peripheral resistive unit. As a result, we successfully obtained the standard conditions of our mechanical circulatory system to be 28/3 (systolic/diastolic) mmHg of right ventricular pressure, 29/7 mmHg of pulmonary arterial pressure, 6 mmHg of mean right atrial pressure, and 3.0 L/min of pulmonary flow rate. To carry out the sophisticated assessment for the support of the pulmonary surgical and percutaneous treatments, we are preparing the next step with the reproduction of respiratory changes in pulmonary peripheral resistance, and the patient-specific shape vascular model including catheter access vessels. Under the highly simulated both pulmonary anatomical morphology and hemodynamic function conditions, effective preclinical examination of newly designed surgical or percutaneous pulmonary circulatory support devices can be performed.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Smith, J.J., Kampine, J.P.: Circulatory Physiology: The Essentials. 2nd Japanese edn. Igaku-Shoin, Tokyo (1989). Smith, J.J., Kampine, J.P.: Circulatory Physiology: The Essentials. 2nd Japanese edn. Igaku-Shoin, Tokyo (1989).
2.
Zurück zum Zitat Suzuki, I., Shiraishi, Y., Yabe, S., Tsuboko, Y., Sugai, T.K., Matsue, K., Kameyama, T., Saijo, Y., Tanaka, T., Okamoto, Y., Feng, Z., Miyazaki, T., Yamagishi, M., Yoshizawa, M., Umezu, M., Yambe, T.: Engineering analysis of the effects of bulging sinuses in a newly designed pediatric pulmonary heart valve on hemodynamic function. Journal of Artificial Organs 15(1), 49–56 (2012). Suzuki, I., Shiraishi, Y., Yabe, S., Tsuboko, Y., Sugai, T.K., Matsue, K., Kameyama, T., Saijo, Y., Tanaka, T., Okamoto, Y., Feng, Z., Miyazaki, T., Yamagishi, M., Yoshizawa, M., Umezu, M., Yambe, T.: Engineering analysis of the effects of bulging sinuses in a newly designed pediatric pulmonary heart valve on hemodynamic function. Journal of Artificial Organs 15(1), 49–56 (2012).
3.
Zurück zum Zitat Tsuboko, T., Shiraishi, Y., Matsuo, S., Yamada, A., Miura, H., Shiga, T., Hashem, M.O., Yambe, T.: Effect of right atrial contraction on prosthetic valve function in a mechanical pulmonary circulatory system. Journal of Biomechanical Science and Engineering 11(6) 15-00356 (2016). Tsuboko, T., Shiraishi, Y., Matsuo, S., Yamada, A., Miura, H., Shiga, T., Hashem, M.O., Yambe, T.: Effect of right atrial contraction on prosthetic valve function in a mechanical pulmonary circulatory system. Journal of Biomechanical Science and Engineering 11(6) 15-00356 (2016).
4.
Zurück zum Zitat Badesch, D.B., Champion, H.C., Sanchez, M.A.G., Hoeper, M.M., Loyd, J.E., Manes, A., McGoon, M., Naeije, R., Olschewski, H., Oudiz, R.J., Torbicki, A.: Diagnosis and assessment of pulmonary arterial hypertension. Journal of American College of Cardiology 54(1), 55–66 (2009). Badesch, D.B., Champion, H.C., Sanchez, M.A.G., Hoeper, M.M., Loyd, J.E., Manes, A., McGoon, M., Naeije, R., Olschewski, H., Oudiz, R.J., Torbicki, A.: Diagnosis and assessment of pulmonary arterial hypertension. Journal of American College of Cardiology 54(1), 55–66 (2009).
5.
Zurück zum Zitat Nichols, W.W., O’Rourke, M.F., Vlachopoulos, C.: McDonald’s Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles. 6th edn. CRC Press, Boca Raton/FL (2011). Nichols, W.W., O’Rourke, M.F., Vlachopoulos, C.: McDonald’s Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles. 6th edn. CRC Press, Boca Raton/FL (2011).
6.
Zurück zum Zitat Murgo, J.P. and Westerhof, N.: Input impedance of the pulmonary arterial system in normal man. Effect of respiration and comparison to systemic impedance. Circulation. 54, 666–73 (1984). Murgo, J.P. and Westerhof, N.: Input impedance of the pulmonary arterial system in normal man. Effect of respiration and comparison to systemic impedance. Circulation. 54, 666–73 (1984).
7.
Zurück zum Zitat Lucas, C.L., Radke, N.F., Wilcox, B.R., Henry, G.W., Keagy B.A.: Maturation of Pulmonary Input Impedance Spectrum in Infants and Children with Ventricular Septal Defect. American Journal of Cardiology 57, 821–827 (1986). Lucas, C.L., Radke, N.F., Wilcox, B.R., Henry, G.W., Keagy B.A.: Maturation of Pulmonary Input Impedance Spectrum in Infants and Children with Ventricular Septal Defect. American Journal of Cardiology 57, 821–827 (1986).
8.
Zurück zum Zitat Weinberg, C.E., Hertzberg, J.R., Ivy, D.D., Kirby, K.S., Chan, K.C., Valdes-Cruz, L., Shandas, R.: Extraction of Pulmonary Vascular Compliance, Pulmonary Vascular Resistance, and Right Ventricular Work from Single-Pressure and Doppler Flow Measurements in Children with Pulmonary Hypertension: a New Method for Evaluating Reactivity. Circulation 110, 2609–2617 (2004). Weinberg, C.E., Hertzberg, J.R., Ivy, D.D., Kirby, K.S., Chan, K.C., Valdes-Cruz, L., Shandas, R.: Extraction of Pulmonary Vascular Compliance, Pulmonary Vascular Resistance, and Right Ventricular Work from Single-Pressure and Doppler Flow Measurements in Children with Pulmonary Hypertension: a New Method for Evaluating Reactivity. Circulation 110, 2609–2617 (2004).
9.
Zurück zum Zitat Hunter, K.S., Lee, P.F., Lanning, C.J., Ivy, D.D., Kirby, K.S., Claussen, L.R., Chan, K.C., Shandas, R.: Pulmonary vascular input impedance is a combined measure of pulmonary vascular resistance and stiffness and predicts clinical outcomes better than pulmonary vascular resistance alone in pediatric patients with pulmonary hypertension. American Heart Journal 155(1), 166–174 (2008). Hunter, K.S., Lee, P.F., Lanning, C.J., Ivy, D.D., Kirby, K.S., Claussen, L.R., Chan, K.C., Shandas, R.: Pulmonary vascular input impedance is a combined measure of pulmonary vascular resistance and stiffness and predicts clinical outcomes better than pulmonary vascular resistance alone in pediatric patients with pulmonary hypertension. American Heart Journal 155(1), 166–174 (2008).
Metadaten
Titel
Sophisticated Hydrodynamic Simulation of Pulmonary Circulation for the Preclinical Examination of Right Heart Circulatory Assist Device
verfasst von
Yusuke Tsuboko
Yasuyuki Shiraishi
Akihiro Yamada
Kiyotaka Iwasaki
Mitsuo Umezu
Tomoyuki Yambe
Copyright-Jahr
2019
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-10-9023-3_130

Neuer Inhalt