Abstract

Purpose

Quantitative description of hepatic microvascular bed could contribute to understanding perfusion CT imaging. Micro-CT is a useful method for the visualization and quantification of capillary-passable vascular corrosion casts. Our aim was to develop and validate open-source software for the statistical description of the vascular networks in micro-CT scans.

Methods

Porcine hepatic microvessels were injected with Biodur E20 resin, and the resulting corrosion casts were scanned with 1.9–4.7 \(\upmu \hbox {m}\) resolution. The microvascular network was quantified using newly developed QuantAn software both in randomly selected volume probes (n = 10) and in arbitrarily outlined hepatic lobules (n = 4). The volumes, surfaces, lengths, and numbers of microvessel segments were estimated and validated in the same data sets with manual stereological counting. Calculations of tortuosity, radius histograms, length histograms, exports of the skeletonized vascular network into open formats, and an assessment of the degree of their anisotropy were performed.

Results

Within hepatic lobules, the microvessels had a volume fraction of 0.13 \(\pm \) 0.05, surface density of 21.0 \(\pm \) 2.0 \(\hbox {mm}^{-1}\), length density of 169.0 \(\pm \) 40.2 \(\hbox {mm}^{-2}\), and numerical density of 588.5 \(\pm \) 283.1 \(\hbox {mm}^{-3}\). Sensitivity analysis of the automatic analysis to binary opening, closing, threshold offset, and aggregation radius of branching nodes was performed.

Conclusion

The software QuantAn and its source code are openly available to researchers working in the field of stochastic geometry of microvessels in micro-CT scans or other three-dimensional imaging methods. The implemented methods comply with reproducible stereological techniques, and they were highly consistent with manual counting. Preliminary morphometrics of the classical hepatic lobules in pig were provided.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Markert M, Koschany A, Lueth T (2010) Tracking of the liver for navigation in open surgery. Int J Comput Assist Radiol Surg 5:229–235CrossRefPubMed Markert M, Koschany A, Lueth T (2010) Tracking of the liver for navigation in open surgery. Int J Comput Assist Radiol Surg 5:229–235CrossRefPubMed
2.
Zurück zum Zitat Ribes D, Peterhans M, Anderegg S, Wallach D, Banz V, Kim-Fuchs C, Candinas D, Weber S (2012) Towards higher precision in instrument guided liver surgery: automatic registration of 3D ultrasound with pre-operative MeVis-CT. Int J Comput Assist Radiol Surg 7(Suppl 1):S141–S142 Ribes D, Peterhans M, Anderegg S, Wallach D, Banz V, Kim-Fuchs C, Candinas D, Weber S (2012) Towards higher precision in instrument guided liver surgery: automatic registration of 3D ultrasound with pre-operative MeVis-CT. Int J Comput Assist Radiol Surg 7(Suppl 1):S141–S142
3.
Zurück zum Zitat Schwier M, Moltz JH, Peitgen HO (2011) Object-based analysis of CT images for automatic detection and segmentation of hypodense liver lesions. Int J Comput Assist Radiol Surg 6:737–747CrossRefPubMed Schwier M, Moltz JH, Peitgen HO (2011) Object-based analysis of CT images for automatic detection and segmentation of hypodense liver lesions. Int J Comput Assist Radiol Surg 6:737–747CrossRefPubMed
4.
Zurück zum Zitat Wallach D, Peterhans M, Brun B, Banz V, Candinas D, Weber S (2012) Development of a surgical template system for application in image guided liver surgery. Int J Comput Assist Radiol Surg 7(Suppl 1):S142–S143 Wallach D, Peterhans M, Brun B, Banz V, Candinas D, Weber S (2012) Development of a surgical template system for application in image guided liver surgery. Int J Comput Assist Radiol Surg 7(Suppl 1):S142–S143
5.
Zurück zum Zitat Hansen C, Zidowitz S, Preim B, Stavrou G, Oldhafer KJ, Hahn HK (2014) Impact of model-based risk analysis for liver surgery planning. Int J Comput Assist Radiol Surg 9:473–480CrossRefPubMed Hansen C, Zidowitz S, Preim B, Stavrou G, Oldhafer KJ, Hahn HK (2014) Impact of model-based risk analysis for liver surgery planning. Int J Comput Assist Radiol Surg 9:473–480CrossRefPubMed
6.
Zurück zum Zitat Hansen C, Zidowitz S, Ritter F, Lange C, Oldhafer K, Hahn HK (2012) Risk maps for liver surgery. Int J Comput Assist Radiol Surg 7(Suppl 1):S144–S145 Hansen C, Zidowitz S, Ritter F, Lange C, Oldhafer K, Hahn HK (2012) Risk maps for liver surgery. Int J Comput Assist Radiol Surg 7(Suppl 1):S144–S145
7.
Zurück zum Zitat Pichon E, Bekes G, Deschamps F, Solomon SB (2008) Development and preliminary evaluation of software for planning selective liver embolizations from three-dimensional rotational fluoroscopy imaging. Int J Comput Assist Radiol Surg 3:405–412CrossRef Pichon E, Bekes G, Deschamps F, Solomon SB (2008) Development and preliminary evaluation of software for planning selective liver embolizations from three-dimensional rotational fluoroscopy imaging. Int J Comput Assist Radiol Surg 3:405–412CrossRef
8.
Zurück zum Zitat Tonar Z, Eberlová L, Polívka J, Daum O, Witter K, Králíčková A, Gregor T, Nedorost L, Kochová P, Rohan E, Kalusová K, Pálek R, Skála M, Glanc D, Králíčková M, Liška V (2012) Stereological methods for quantitative assessment of hepatic microcirculation. In: Méndez-Villas A (ed) Current microscopy contributions to advances in science and technology., Microscopy book series 2012 editionFormatex Research Center, Badajoz, pp 737–748 Tonar Z, Eberlová L, Polívka J, Daum O, Witter K, Králíčková A, Gregor T, Nedorost L, Kochová P, Rohan E, Kalusová K, Pálek R, Skála M, Glanc D, Králíčková M, Liška V (2012) Stereological methods for quantitative assessment of hepatic microcirculation. In: Méndez-Villas A (ed) Current microscopy contributions to advances in science and technology., Microscopy book series 2012 editionFormatex Research Center, Badajoz, pp 737–748
9.
Zurück zum Zitat Hammad S, Hoehme S, Friebel A, von Recklinghausen I, Othman A, Begher-Tibbe B, Reif R, Godoy P, Johann T, Vartak A, Golka K, Bucur PO, Vibert E, Marchan R, Christ B, Dooley S, Meyer C, Ilkavets I, Dahmen U, Dirsch O, Böttger J, Gebhardt R, Drasdo D, Hengstler JG (2014) Protocols for staining of bile canalicular and sinusoidal networks of human, mouse and pig livers, three-dimensional reconstruction and quantification of tissue microarchitecture by image processing and analysis. Arch Toxicol 88:1161–1183CrossRefPubMedPubMedCentral Hammad S, Hoehme S, Friebel A, von Recklinghausen I, Othman A, Begher-Tibbe B, Reif R, Godoy P, Johann T, Vartak A, Golka K, Bucur PO, Vibert E, Marchan R, Christ B, Dooley S, Meyer C, Ilkavets I, Dahmen U, Dirsch O, Böttger J, Gebhardt R, Drasdo D, Hengstler JG (2014) Protocols for staining of bile canalicular and sinusoidal networks of human, mouse and pig livers, three-dimensional reconstruction and quantification of tissue microarchitecture by image processing and analysis. Arch Toxicol 88:1161–1183CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Schwier M, Böhler T, Hahn HK, Dahmen U, Dirsch O (2013) Registration of histological whole slide images guided by vessel structures. J Pathol Inform 4(Suppl):S10CrossRefPubMedPubMedCentral Schwier M, Böhler T, Hahn HK, Dahmen U, Dirsch O (2013) Registration of histological whole slide images guided by vessel structures. J Pathol Inform 4(Suppl):S10CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Wei W, Dirsch O, Mclean AL, Zafarnia S, Schwier M, Dahmen U (2015) Rodent models and imaging techniques to study liver regeneration. Eur Surg Res 54:97–113CrossRefPubMed Wei W, Dirsch O, Mclean AL, Zafarnia S, Schwier M, Dahmen U (2015) Rodent models and imaging techniques to study liver regeneration. Eur Surg Res 54:97–113CrossRefPubMed
13.
Zurück zum Zitat Lang S, Müller B, Dominietto MD, Cattin PC, Zanette I, Weitkamp T, Hieber SE (2012) Three-dimensional quantification of capillary networks in healthy and cancerous tissues of two mice. Microvasc Res 84:314–322CrossRefPubMed Lang S, Müller B, Dominietto MD, Cattin PC, Zanette I, Weitkamp T, Hieber SE (2012) Three-dimensional quantification of capillary networks in healthy and cancerous tissues of two mice. Microvasc Res 84:314–322CrossRefPubMed
14.
Zurück zum Zitat Foruzan AH, Chen YW, Hori M, Sato Y, Tomiyama N (2014) Capturing large shape variations of liver using population-based statistical shape models. Int J Comput Assist Radiol Surg 9:967–977CrossRefPubMed Foruzan AH, Chen YW, Hori M, Sato Y, Tomiyama N (2014) Capturing large shape variations of liver using population-based statistical shape models. Int J Comput Assist Radiol Surg 9:967–977CrossRefPubMed
15.
Zurück zum Zitat Stoyan D, Kendall WS, Mecke J (1995) Stochastic geometry and its applications. Wiley, New York Stoyan D, Kendall WS, Mecke J (1995) Stochastic geometry and its applications. Wiley, New York
16.
Zurück zum Zitat Baddeley A, Jensen EB (2004) Stereology for statisticians. CRC, Boca RatonCrossRef Baddeley A, Jensen EB (2004) Stereology for statisticians. CRC, Boca RatonCrossRef
17.
Zurück zum Zitat Králíčková A, Eberlová L, Kalusová K, Gregor T, Kochová P, Liška V, Králíčková M, Tonar Z (2014) Quantification of liver microcirculation using X-ray microtomography of vascular corrosion casts. Key Eng Mat 592–593:505–508 Králíčková A, Eberlová L, Kalusová K, Gregor T, Kochová P, Liška V, Králíčková M, Tonar Z (2014) Quantification of liver microcirculation using X-ray microtomography of vascular corrosion casts. Key Eng Mat 592–593:505–508
18.
Zurück zum Zitat Bruha J, Vycital O, Tonar Z, Mirka H, Haidingerova L, Benes J, Palek R, Skala M, Treska V, Liska V (2015) Monoclonal antibody against transforming growth factor Beta 1 does not influence liver regeneration after resection in large animal experiments. In Vivo 29:327–340PubMed Bruha J, Vycital O, Tonar Z, Mirka H, Haidingerova L, Benes J, Palek R, Skala M, Treska V, Liska V (2015) Monoclonal antibody against transforming growth factor Beta 1 does not influence liver regeneration after resection in large animal experiments. In Vivo 29:327–340PubMed
19.
Zurück zum Zitat Freiman M, Eliassaf O, Taieb Y, Joskowicz L, Azraq Y, Sosna J (2008) An iterative Bayesian approach for nearly automatic liver segmentation: algorithm and validation. Int J Comput Assist Radiol Surg 3:439–446CrossRef Freiman M, Eliassaf O, Taieb Y, Joskowicz L, Azraq Y, Sosna J (2008) An iterative Bayesian approach for nearly automatic liver segmentation: algorithm and validation. Int J Comput Assist Radiol Surg 3:439–446CrossRef
20.
Zurück zum Zitat Mühlfeld C (2014) Quantitative morphology of the vascularisation of organs: a stereological approach illustrated using the cardiac circulation. Ann Anat 196:12–19CrossRefPubMed Mühlfeld C (2014) Quantitative morphology of the vascularisation of organs: a stereological approach illustrated using the cardiac circulation. Ann Anat 196:12–19CrossRefPubMed
21.
Zurück zum Zitat Eberlova L, Liska V, Mirka H, Gregor T, Tonar Z, Palek R, Skala M, Bruha J, Vycital O, Kalusova K, Haviar S, Kralickova M, Lametschwandtner A (2015) Porcine liver vascular bed in Biodur E20 corrosion casts. In Press. Folia Morphol (Warsz). In press Eberlova L, Liska V, Mirka H, Gregor T, Tonar Z, Palek R, Skala M, Bruha J, Vycital O, Kalusova K, Haviar S, Kralickova M, Lametschwandtner A (2015) Porcine liver vascular bed in Biodur E20 corrosion casts. In Press. Folia Morphol (Warsz). In press
22.
Zurück zum Zitat Lametschwandtner A, Miodonski A, Simonsberger P (1980) On the prevention of specimen charging in scanning electron microscopy of vascular corrosion casts by attaching conductive bridges. Mikroskopie 36:270–3PubMed Lametschwandtner A, Miodonski A, Simonsberger P (1980) On the prevention of specimen charging in scanning electron microscopy of vascular corrosion casts by attaching conductive bridges. Mikroskopie 36:270–3PubMed
23.
Zurück zum Zitat Howard CV, Reed MG (1998) Unbiased stereology: three-dimensional measurement in microscopy. Springer, New York Howard CV, Reed MG (1998) Unbiased stereology: three-dimensional measurement in microscopy. Springer, New York
24.
Zurück zum Zitat Mouton PR (2002) Principles and practices of unbiased stereology: an introduction for bioscientists. The Johns Hopkins University Press, Baltimore Mouton PR (2002) Principles and practices of unbiased stereology: an introduction for bioscientists. The Johns Hopkins University Press, Baltimore
25.
Zurück zum Zitat Kubínová L, Janáček J (1998) Estimating surface area by the isotropic fakir method from thick slices cut in an arbitrary direction. J Microsc 191:201–211CrossRefPubMed Kubínová L, Janáček J (1998) Estimating surface area by the isotropic fakir method from thick slices cut in an arbitrary direction. J Microsc 191:201–211CrossRefPubMed
26.
Zurück zum Zitat Gundersen HJ, Bagger P, Bendtsen TF, Evans SM, Korbo L, Marcussen N, Moller A, Nielsen K, Nyengaard JR, Pakkenberg B (1988) The new stereological tools: disector, fractionator, nucleator and point sampled intercepts and their use in pathological research and diagnosis. APMIS 96:857–881CrossRefPubMed Gundersen HJ, Bagger P, Bendtsen TF, Evans SM, Korbo L, Marcussen N, Moller A, Nielsen K, Nyengaard JR, Pakkenberg B (1988) The new stereological tools: disector, fractionator, nucleator and point sampled intercepts and their use in pathological research and diagnosis. APMIS 96:857–881CrossRefPubMed
27.
Zurück zum Zitat Lokkegaard A, Nyengaard JR, West MJ (2001) Stereological estimates of number and length of capillaries in subdivisions of the hippocampal region. Hippocampus 11:726–740CrossRefPubMed Lokkegaard A, Nyengaard JR, West MJ (2001) Stereological estimates of number and length of capillaries in subdivisions of the hippocampal region. Hippocampus 11:726–740CrossRefPubMed
28.
Zurück zum Zitat Jirik M, Kunes J, Zelezny M (2015) Semiautomatic Quantitative Evaluation of Micro-CT Data. Lect Notes Comput Sc. Accepted manuscript in Press Jirik M, Kunes J, Zelezny M (2015) Semiautomatic Quantitative Evaluation of Micro-CT Data. Lect Notes Comput Sc. Accepted manuscript in Press
30.
Zurück zum Zitat Otsu N (1979) A threshold selection method from gray-level histograms. IEEE Trans Sys Man Cyber 9:62–66CrossRef Otsu N (1979) A threshold selection method from gray-level histograms. IEEE Trans Sys Man Cyber 9:62–66CrossRef
31.
Zurück zum Zitat Dryden IL, Koloydenko A, Zhou D (2009) Non-Euclidean statistics for covariance matrices, with applications to diffusion tensor imaging. Ann Appl Stat 3:1102–1123CrossRef Dryden IL, Koloydenko A, Zhou D (2009) Non-Euclidean statistics for covariance matrices, with applications to diffusion tensor imaging. Ann Appl Stat 3:1102–1123CrossRef
33.
Zurück zum Zitat Kochová P, Cimrman R, Janáček J, Witter K, Tonar Z (2011) How to asses, visualize and compare the anisotropy of linear structures reconstructed from optical sections—A study based on histopathological quantification of human brain microvessels. J Theor Biol 286:67–78CrossRefPubMed Kochová P, Cimrman R, Janáček J, Witter K, Tonar Z (2011) How to asses, visualize and compare the anisotropy of linear structures reconstructed from optical sections—A study based on histopathological quantification of human brain microvessels. J Theor Biol 286:67–78CrossRefPubMed
34.
Zurück zum Zitat Lin LK (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268CrossRefPubMed Lin LK (1989) A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255–268CrossRefPubMed
35.
Zurück zum Zitat Lin LK (2000) A note on the concordance correlation coefficient. Biometrics 56:324–325CrossRef Lin LK (2000) A note on the concordance correlation coefficient. Biometrics 56:324–325CrossRef
38.
Zurück zum Zitat Yousefi S, Liu T, Wang RK (2015) Segmentation and quantification of blood vessels for OCT-based micro-angiograms using hybrid shape/intensity compounding. Microvasc Res 97:37–46CrossRefPubMed Yousefi S, Liu T, Wang RK (2015) Segmentation and quantification of blood vessels for OCT-based micro-angiograms using hybrid shape/intensity compounding. Microvasc Res 97:37–46CrossRefPubMed
39.
Zurück zum Zitat Hoehme S, Brulport M, Bauer A, Bedawy E, Schormann W, Hermes M, Puppe V, Gebhardt R, Zellmer S, Schwarz M, Bockamp E, Timmel T, Hengstler JG, Drasdo D (2010) Prediction and validation of cell alignment along microvessels as order principle to restore tissue architecture in liver regeneration. Proc Natl Acad Sci USA 107:10371–10376CrossRefPubMedPubMedCentral Hoehme S, Brulport M, Bauer A, Bedawy E, Schormann W, Hermes M, Puppe V, Gebhardt R, Zellmer S, Schwarz M, Bockamp E, Timmel T, Hengstler JG, Drasdo D (2010) Prediction and validation of cell alignment along microvessels as order principle to restore tissue architecture in liver regeneration. Proc Natl Acad Sci USA 107:10371–10376CrossRefPubMedPubMedCentral
40.
Zurück zum Zitat Miles KA, Griffiths MR (2003) Perfusion CT: a worthwhile enhancement? Brit J Radiol 76:220–231CrossRefPubMed Miles KA, Griffiths MR (2003) Perfusion CT: a worthwhile enhancement? Brit J Radiol 76:220–231CrossRefPubMed
41.
Zurück zum Zitat Pandharipande PV, Krinsky GA, Rusinek H, Lee VS (2005) Perfusion imaging of the liver: current challenges and future goals. Radiology 234:661–673CrossRefPubMed Pandharipande PV, Krinsky GA, Rusinek H, Lee VS (2005) Perfusion imaging of the liver: current challenges and future goals. Radiology 234:661–673CrossRefPubMed
42.
Zurück zum Zitat Tofts PS, Brix G, Buckley DL, Evelhoch JL, Henderson E, Knopp MV, Larsson HBW, Lee TY, Mayr NA, Parker GJM, Port Ruediger E, Taylor J, Weisskoff RM (1999) Estimating kinetic parameters from dynamic contrast-enhanced t1-weighted mri of a diffusable tracer: standardized quantities and symbols. J Magn Reson Im 10:223–232CrossRef Tofts PS, Brix G, Buckley DL, Evelhoch JL, Henderson E, Knopp MV, Larsson HBW, Lee TY, Mayr NA, Parker GJM, Port Ruediger E, Taylor J, Weisskoff RM (1999) Estimating kinetic parameters from dynamic contrast-enhanced t1-weighted mri of a diffusable tracer: standardized quantities and symbols. J Magn Reson Im 10:223–232CrossRef
44.
Zurück zum Zitat Van Beers BE, Leconte I, Materne R, Smith AM, Jamart J, Horsmans Y (2001) Hepatic perfusion parameters in chronic liver disease: dynamic CT measurements correlated with disease severity. Am J Roentgenol 176:667–673CrossRef Van Beers BE, Leconte I, Materne R, Smith AM, Jamart J, Horsmans Y (2001) Hepatic perfusion parameters in chronic liver disease: dynamic CT measurements correlated with disease severity. Am J Roentgenol 176:667–673CrossRef
45.
Zurück zum Zitat Cuenod C, Leconte I, Siauve N, Resten A, Dromain C, Poulet B, Frouin F, Clément O, Frija G (2001) Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT 1. Radiology 218:556–561CrossRefPubMed Cuenod C, Leconte I, Siauve N, Resten A, Dromain C, Poulet B, Frouin F, Clément O, Frija G (2001) Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT 1. Radiology 218:556–561CrossRefPubMed
46.
Zurück zum Zitat Goh V, Gourtsoyianni S, Koh DM (2013) Functional imaging of the liver. Semin Ultrasound CT MR 34:54–65CrossRefPubMed Goh V, Gourtsoyianni S, Koh DM (2013) Functional imaging of the liver. Semin Ultrasound CT MR 34:54–65CrossRefPubMed
47.
Zurück zum Zitat Chen G, Ma DO, He W, Zhang BF, Zhao LQ (2008) Computed tomography perfusion in evaluating the therapeutic effect of transarterial chemoembolization for hepatocellular carcinoma. World J Gastroenterol 14:5738–5743CrossRefPubMedPubMedCentral Chen G, Ma DO, He W, Zhang BF, Zhao LQ (2008) Computed tomography perfusion in evaluating the therapeutic effect of transarterial chemoembolization for hepatocellular carcinoma. World J Gastroenterol 14:5738–5743CrossRefPubMedPubMedCentral
48.
Zurück zum Zitat Tang Y, Nyengaard JR, Andersen JB, Baandrup U, Gundersen HJ (2009) The application of stereological methods for estimating structural parameters in the human heart. Anat Rec (Hoboken) 292:1630–1647CrossRef Tang Y, Nyengaard JR, Andersen JB, Baandrup U, Gundersen HJ (2009) The application of stereological methods for estimating structural parameters in the human heart. Anat Rec (Hoboken) 292:1630–1647CrossRef
49.
Zurück zum Zitat Tonar Z, Egger GF, Witter K, Wolfesberger B (2008) Quantification of microvessels in canine lymph nodes. Microsc Res Tech 71:760–772CrossRefPubMed Tonar Z, Egger GF, Witter K, Wolfesberger B (2008) Quantification of microvessels in canine lymph nodes. Microsc Res Tech 71:760–772CrossRefPubMed
50.
Zurück zum Zitat Tonar Z, Khadang I, Fiala P, Nedorost L, Kochová P (2011) Quantification of compact bone microporosities in the basal and alveolar portions of the human mandible using osteocyte lacunar density and area fraction of vascular canals. Ann Anat 193:211–219CrossRefPubMed Tonar Z, Khadang I, Fiala P, Nedorost L, Kochová P (2011) Quantification of compact bone microporosities in the basal and alveolar portions of the human mandible using osteocyte lacunar density and area fraction of vascular canals. Ann Anat 193:211–219CrossRefPubMed
51.
Zurück zum Zitat Tonar Z, Kural T Jr, Kochová P, Nedorost L, Witter K (2012) Vasa vasorum quantification in human varicose great and small saphenous veins. Ann Anat 194:473–481CrossRefPubMed Tonar Z, Kural T Jr, Kochová P, Nedorost L, Witter K (2012) Vasa vasorum quantification in human varicose great and small saphenous veins. Ann Anat 194:473–481CrossRefPubMed
53.
Zurück zum Zitat Coussy O (2004) Poromechanics. Wiley, Chichester Coussy O (2004) Poromechanics. Wiley, Chichester
54.
Zurück zum Zitat Moreno R, Borga M, Smedby O (2014) Techniques for computing fabric tensors: a review. In: Westin CF, Vilanova A, Burgeth B (eds) Visualization and processing of tensors and higher order descriptors for multi-valued data. Springer, Berlin, pp 271–292 Moreno R, Borga M, Smedby O (2014) Techniques for computing fabric tensors: a review. In: Westin CF, Vilanova A, Burgeth B (eds) Visualization and processing of tensors and higher order descriptors for multi-valued data. Springer, Berlin, pp 271–292
55.
Zurück zum Zitat Debbaut C, Vierendeels J, Casteleyn C, Cornillie P, Van Loo D, Simoens P, Van Hoorebeke L, Monbaliu D, Segers P (2012) Perfusion characteristics of the human hepatic microcirculation based on three-dimensional reconstructions and computational fluid dynamic analysis. J Biomech Eng 134:011003CrossRefPubMed Debbaut C, Vierendeels J, Casteleyn C, Cornillie P, Van Loo D, Simoens P, Van Hoorebeke L, Monbaliu D, Segers P (2012) Perfusion characteristics of the human hepatic microcirculation based on three-dimensional reconstructions and computational fluid dynamic analysis. J Biomech Eng 134:011003CrossRefPubMed
56.
Zurück zum Zitat Kalitzeos AA, Lip GY, Heitmar R (2013) Retinal vessel tortuosity measures and their applications. Exp Eye Res 106:40–46CrossRefPubMed Kalitzeos AA, Lip GY, Heitmar R (2013) Retinal vessel tortuosity measures and their applications. Exp Eye Res 106:40–46CrossRefPubMed
Metadaten
Titel
Stereological quantification of microvessels using semiautomated evaluation of X-ray microtomography of hepatic vascular corrosion casts
verfasst von
Miroslav Jiřík
Zbyněk Tonar
Anna Králíčková
Lada Eberlová
Hynek Mírka
Petra Kochová
Tomáš Gregor
Petr Hošek
Miroslava Svobodová
Eduard Rohan
Milena Králíčková
Václav Liška
Publikationsdatum
01.10.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 10/2016
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-016-1378-3

Weitere Artikel der Ausgabe 10/2016

International Journal of Computer Assisted Radiology and Surgery 10/2016 Zur Ausgabe

Premium Partner