Skip to main content

2018 | OriginalPaper | Buchkapitel

10. Surface Plasmon Resonance Sensors for Medical Diagnosis

verfasst von : Yeşeren Saylan, Fatma Yılmaz, Erdoğan Özgür, Ali Derazshamshir, Nilay Bereli, Handan Yavuz, Adil Denizli

Erschienen in: Nanotechnology Characterization Tools for Biosensing and Medical Diagnosis

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Surface plasmon resonance (SPR) sensors have fascinated impressive attention to detect clinically related analytes in recent years. SPR sensors have also multiple advantages over existing conventional diagnostic tools such as easy preparation, no requirement of labeling, and high specificity and sensitivity with low cost, and they provide real-time detection capability. There are some articles and reviews in literature focusing on the applications of SPR-based sensors for the diagnosis of medically important entities such as proteins, cells, viruses, disease biomarkers, etc. These articles generally give information on the determination of such structures merely, whereas this presented manuscript combines recent literature for most of the medically important structures together including proteins, hormones, nucleic acids, whole cells, and drugs that especially the latest applications of SPR sensors for medical diagnosis to follow up new strategies and discuss how SPR strategy is brought to solve the medical problems.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Labib M, Sargent EH, Kelley SO (2016) Electrochemical methods for the analysis of clinically relevant biomolecules. Chem Rev 116:9001–9090CrossRef Labib M, Sargent EH, Kelley SO (2016) Electrochemical methods for the analysis of clinically relevant biomolecules. Chem Rev 116:9001–9090CrossRef
2.
Zurück zum Zitat Stojanović I, Schasfoort RBM, Terstappen LWMM (2014) Analysis of cell surface antigens by surface plasmon resonance imaging. Biosens Bioelectron 52:36–43CrossRef Stojanović I, Schasfoort RBM, Terstappen LWMM (2014) Analysis of cell surface antigens by surface plasmon resonance imaging. Biosens Bioelectron 52:36–43CrossRef
3.
Zurück zum Zitat Saylan Y, Yılmaz F, Derazshamshir A, Yılmaz E, Denizli A (2017) Synthesis of hydrophobic nanoparticles for real-time lysozyme detection using surface plasmon resonance sensor. J Mol Recognit 30:e2631.1–7CrossRef Saylan Y, Yılmaz F, Derazshamshir A, Yılmaz E, Denizli A (2017) Synthesis of hydrophobic nanoparticles for real-time lysozyme detection using surface plasmon resonance sensor. J Mol Recognit 30:e2631.1–7CrossRef
4.
Zurück zum Zitat Saylan Y, Akgönüllü S, Çimen D, Derazshamshir A, Bereli N, Yılmaz F, Denizli A (2017) Surface plasmon resonance nanosensors based on molecularly imprinted nanofilm for detection of pesticides. Sensors Actuators B Chem 241:446–454CrossRef Saylan Y, Akgönüllü S, Çimen D, Derazshamshir A, Bereli N, Yılmaz F, Denizli A (2017) Surface plasmon resonance nanosensors based on molecularly imprinted nanofilm for detection of pesticides. Sensors Actuators B Chem 241:446–454CrossRef
5.
Zurück zum Zitat Ronkainen NJ, Halsall HB, Heineman WR (2010) Electrochemical biosensors. Chem Soc Rev 39:1747–1763CrossRef Ronkainen NJ, Halsall HB, Heineman WR (2010) Electrochemical biosensors. Chem Soc Rev 39:1747–1763CrossRef
6.
Zurück zum Zitat Guerreiro GV, Zaitouna AJ, Lai RY (2014) Characterization of an electrochemical mercury sensor using alternating current, cyclic, square wave and differential pulse voltammetry. Anal Chim Acta 810:79–85CrossRef Guerreiro GV, Zaitouna AJ, Lai RY (2014) Characterization of an electrochemical mercury sensor using alternating current, cyclic, square wave and differential pulse voltammetry. Anal Chim Acta 810:79–85CrossRef
7.
Zurück zum Zitat Campuzanoa S, Kuralay F, Lobo-Castañón MJ, Bartošík M, Vyavaharea K, Paleček E, Haake DA, Wang J (2011) Ternary monolayers as DNA recognition interfaces for direct and sensitive electrochemical detection in untreated clinical samples. Biosens Bioelectron 26(8):3577–3583CrossRef Campuzanoa S, Kuralay F, Lobo-Castañón MJ, Bartošík M, Vyavaharea K, Paleček E, Haake DA, Wang J (2011) Ternary monolayers as DNA recognition interfaces for direct and sensitive electrochemical detection in untreated clinical samples. Biosens Bioelectron 26(8):3577–3583CrossRef
8.
Zurück zum Zitat Atay S, Pişkin K, Yılmaz F, Çakır C, Yavuz H, Denizli A (2016) Quartz crystal microbalance based biosensors for detecting highly metastatic breast cancer cells via their transferrin receptors. Anal Methods 8:153–161CrossRef Atay S, Pişkin K, Yılmaz F, Çakır C, Yavuz H, Denizli A (2016) Quartz crystal microbalance based biosensors for detecting highly metastatic breast cancer cells via their transferrin receptors. Anal Methods 8:153–161CrossRef
9.
Zurück zum Zitat Çiçek Ç, Yılmaz F, Özgür E, Yavuz H, Denizli A (2016) Molecularly imprinted quartz crystal microbalance sensor (QCM) for bilirubin detection. Chemosensors 4(4):21–34CrossRef Çiçek Ç, Yılmaz F, Özgür E, Yavuz H, Denizli A (2016) Molecularly imprinted quartz crystal microbalance sensor (QCM) for bilirubin detection. Chemosensors 4(4):21–34CrossRef
10.
Zurück zum Zitat Sener G, Ozgur E, Yılmaz E, Uzun L, Say R, Denizli A (2010) Quartz crystal microbalance based nanosensor for lysozyme detection with lysozyme imprinted nanoparticles. Biosens Bioelectron 26:815–821CrossRef Sener G, Ozgur E, Yılmaz E, Uzun L, Say R, Denizli A (2010) Quartz crystal microbalance based nanosensor for lysozyme detection with lysozyme imprinted nanoparticles. Biosens Bioelectron 26:815–821CrossRef
11.
Zurück zum Zitat Wang Y, Li J, Viehland D (2014) Magnetoelectrics for magnetic sensor applications: status, challenges and perspectives. Mater Today 17(6):269–275CrossRef Wang Y, Li J, Viehland D (2014) Magnetoelectrics for magnetic sensor applications: status, challenges and perspectives. Mater Today 17(6):269–275CrossRef
12.
Zurück zum Zitat Melzer M, Karnaushenko D, Lin G, Baunack S, Makarov D, Schmidt OG (2015) Direct transfer of magnetic sensor devices to elastomeric supports for stretchable electronics. Adv Mater 27(8):1333–1338CrossRef Melzer M, Karnaushenko D, Lin G, Baunack S, Makarov D, Schmidt OG (2015) Direct transfer of magnetic sensor devices to elastomeric supports for stretchable electronics. Adv Mater 27(8):1333–1338CrossRef
13.
Zurück zum Zitat Zhang Y, Shen J, Yang H, Yang Y, Zhou Z, Yang S (2015) A highly selective magnetic sensor for Cd2+ in living cells with (Zn, Mn)-doped iron oxide nanoparticles. Sensors Actuators B Chem 207:887–892CrossRef Zhang Y, Shen J, Yang H, Yang Y, Zhou Z, Yang S (2015) A highly selective magnetic sensor for Cd2+ in living cells with (Zn, Mn)-doped iron oxide nanoparticles. Sensors Actuators B Chem 207:887–892CrossRef
14.
Zurück zum Zitat Peiker P, Oesterschulze E (2015) Geometrically tuned wettability of dynamic micromechanical sensors for an improved in-liquid operation. Appl Phys Lett 107(10):101903–101907CrossRef Peiker P, Oesterschulze E (2015) Geometrically tuned wettability of dynamic micromechanical sensors for an improved in-liquid operation. Appl Phys Lett 107(10):101903–101907CrossRef
15.
Zurück zum Zitat Borin D, Melli M, Zilio SD, Toffoli V, Scoles G, Toffoli G, Lazzarino M (2014) How to engineer superhydrophobic micromechanical sensors preserving mass resolution. Sensors Actuators B Chem 199:62–69CrossRef Borin D, Melli M, Zilio SD, Toffoli V, Scoles G, Toffoli G, Lazzarino M (2014) How to engineer superhydrophobic micromechanical sensors preserving mass resolution. Sensors Actuators B Chem 199:62–69CrossRef
16.
Zurück zum Zitat Hu KM, Zhang WM, Shi X, Yan H, Peng ZK, Meng G (2016) Adsorption-induced surface effects on the dynamical characteristics of micromechanical resonant sensors for in situ real-time detection. J Appl Mech 83(8):081009–081020CrossRef Hu KM, Zhang WM, Shi X, Yan H, Peng ZK, Meng G (2016) Adsorption-induced surface effects on the dynamical characteristics of micromechanical resonant sensors for in situ real-time detection. J Appl Mech 83(8):081009–081020CrossRef
17.
Zurück zum Zitat Guo X (2012) Surface plasmon resonance based biosensor technique: a review. J Biophotonics 5(7):483–501CrossRef Guo X (2012) Surface plasmon resonance based biosensor technique: a review. J Biophotonics 5(7):483–501CrossRef
18.
Zurück zum Zitat Fu E, Chinowsky T, Nelson K, Yager P (2008) Chapter 10: SPR imaging for clinical diagnostics. In: Handbook of surface plasmon resonance. Royal Society of Chemistry, Cambridge, pp 313–332CrossRef Fu E, Chinowsky T, Nelson K, Yager P (2008) Chapter 10: SPR imaging for clinical diagnostics. In: Handbook of surface plasmon resonance. Royal Society of Chemistry, Cambridge, pp 313–332CrossRef
19.
Zurück zum Zitat Caucheteur C, Guo T, Albert J (2015) Review of plasmonic fiber optic biochemical sensors: improving the limit of detection. Anal Bioanal Chem 407:3883–3897CrossRef Caucheteur C, Guo T, Albert J (2015) Review of plasmonic fiber optic biochemical sensors: improving the limit of detection. Anal Bioanal Chem 407:3883–3897CrossRef
20.
Zurück zum Zitat Wood RW (1902) On a remarkable case of uneven distribution of light in a diffraction grating spectrum. Philos Mag 4:396–402CrossRef Wood RW (1902) On a remarkable case of uneven distribution of light in a diffraction grating spectrum. Philos Mag 4:396–402CrossRef
21.
Zurück zum Zitat Cowan JJ (1972) The surface plasmon resonance effect in holography. Opt Commun 5:69–72CrossRef Cowan JJ (1972) The surface plasmon resonance effect in holography. Opt Commun 5:69–72CrossRef
22.
Zurück zum Zitat Schneider FW (1982) Non-linear Raman spectroscopy and its chemical applications. Biological applications of resonance CARS, Reidel Publishing Company Dordrecht: Holland/Boston: USA/London: England vol 93, pp 445–459CrossRef Schneider FW (1982) Non-linear Raman spectroscopy and its chemical applications. Biological applications of resonance CARS, Reidel Publishing Company Dordrecht: Holland/Boston: USA/London: England vol 93, pp 445–459CrossRef
23.
Zurück zum Zitat Rothenbausler B, Knoll W (1988) Surface–plasmon microscopy. Nature 332:615–617CrossRef Rothenbausler B, Knoll W (1988) Surface–plasmon microscopy. Nature 332:615–617CrossRef
24.
Zurück zum Zitat Hickel W, Knoll W (1989) Surface plasmon microscopic imaging of ultrathin metal coatings. Acta Metall 37:2141–2144CrossRef Hickel W, Knoll W (1989) Surface plasmon microscopic imaging of ultrathin metal coatings. Acta Metall 37:2141–2144CrossRef
25.
Zurück zum Zitat Otto A (1968) Excitation of nonradiative surface plasma waves in silver by the method of frustrated total reflection. Z Phys 16:398–410CrossRef Otto A (1968) Excitation of nonradiative surface plasma waves in silver by the method of frustrated total reflection. Z Phys 16:398–410CrossRef
26.
Zurück zum Zitat Buck RP (1990) Biosensor technology: fundamentals and applications. Marcel Dekker, New York Buck RP (1990) Biosensor technology: fundamentals and applications. Marcel Dekker, New York
27.
Zurück zum Zitat Szentirmay Z (1992) Surface plasmon spectroscopy of metal/dielectric structures. Spectrochim Acta 48:9–17CrossRef Szentirmay Z (1992) Surface plasmon spectroscopy of metal/dielectric structures. Spectrochim Acta 48:9–17CrossRef
28.
Zurück zum Zitat Welford K (1991) Surface plasmon-polaritons and their uses. Opt Quant Electron 23:1–27CrossRef Welford K (1991) Surface plasmon-polaritons and their uses. Opt Quant Electron 23:1–27CrossRef
29.
Zurück zum Zitat Gutiérrez-Gallego R, Llop E, Bosch J, Segura J (2011) Surface plasmon resonance in doping analysis. Anal Bioanal Chem 401:389–403CrossRef Gutiérrez-Gallego R, Llop E, Bosch J, Segura J (2011) Surface plasmon resonance in doping analysis. Anal Bioanal Chem 401:389–403CrossRef
30.
Zurück zum Zitat Masson JF (2017) Surface plasmon resonance clinical biosensors for medical diagnostics. ACS Sens 2(1):16–30CrossRef Masson JF (2017) Surface plasmon resonance clinical biosensors for medical diagnostics. ACS Sens 2(1):16–30CrossRef
31.
Zurück zum Zitat Situ C, Mooney MH, Elliott CT, Buijs J (2010) Advances in surface plasmon resonance biosensor technology towards high-throughput, food-safety analysis. TrAC Trends Anal Chem 29:1305–1315CrossRef Situ C, Mooney MH, Elliott CT, Buijs J (2010) Advances in surface plasmon resonance biosensor technology towards high-throughput, food-safety analysis. TrAC Trends Anal Chem 29:1305–1315CrossRef
32.
Zurück zum Zitat Helmerhorst E, Chandler DJ, Nussio M, Mamotte CD (2012) Real-time and label-free bio-sensing of molecular interactions by surface plasmon resonance: a laboratory medicine perspective. Clin Biochem Rev 33:161–173 Helmerhorst E, Chandler DJ, Nussio M, Mamotte CD (2012) Real-time and label-free bio-sensing of molecular interactions by surface plasmon resonance: a laboratory medicine perspective. Clin Biochem Rev 33:161–173
33.
Zurück zum Zitat Tokel O, Yildiz UH, Inci F, Durmus NG, Ekiz OO, Turker B, Cetin C, Rao S, Sridhar K, Natarajan N, Shafiee H, Dana A, Demirci U (2015) Portable microfluidic integrated plasmonic platform for pathogen detection. Sci Rep 5:9152–9161CrossRef Tokel O, Yildiz UH, Inci F, Durmus NG, Ekiz OO, Turker B, Cetin C, Rao S, Sridhar K, Natarajan N, Shafiee H, Dana A, Demirci U (2015) Portable microfluidic integrated plasmonic platform for pathogen detection. Sci Rep 5:9152–9161CrossRef
34.
Zurück zum Zitat Laocharoensuk R (2016) Development of electrochemical immunosensors towards point-of-care cancer diagnostics: clinically relevant studies. Electroanalysis 28:1716–1729CrossRef Laocharoensuk R (2016) Development of electrochemical immunosensors towards point-of-care cancer diagnostics: clinically relevant studies. Electroanalysis 28:1716–1729CrossRef
35.
Zurück zum Zitat Ouellet E, Lund L, Lagally E (2013) Chapter 30: Multiplexed surface plasmon resonance imaging for protein biomarker analysis. In: Microfluidic diagnostics. Methods in molecular biology, Springer Science+Business Media, LLC, Berlin/Heidelberg, Germany vol 949. pp 473–490 Ouellet E, Lund L, Lagally E (2013) Chapter 30: Multiplexed surface plasmon resonance imaging for protein biomarker analysis. In: Microfluidic diagnostics. Methods in molecular biology, Springer Science+Business Media, LLC, Berlin/Heidelberg, Germany vol 949. pp 473–490
36.
Zurück zum Zitat Kirsch J, Siltanen C, Zhou Q, Revzin A, Simonian A (2013) Biosensor technology: recent advances in threat agent detection and medicine. Chem Soc Rev 42:8733–8769CrossRef Kirsch J, Siltanen C, Zhou Q, Revzin A, Simonian A (2013) Biosensor technology: recent advances in threat agent detection and medicine. Chem Soc Rev 42:8733–8769CrossRef
37.
Zurück zum Zitat Ranjan R, Esimbekova EN, Kratasyuk VA (2017) Rapid biosensing tools for cancer biomarkers. Biosens Bioelectron 87:918–930CrossRef Ranjan R, Esimbekova EN, Kratasyuk VA (2017) Rapid biosensing tools for cancer biomarkers. Biosens Bioelectron 87:918–930CrossRef
38.
Zurück zum Zitat Aćimović SS, Ortega MA, Sanz V, Berthelot J, Garcia-Cordero JL, Renger J, Maerkl SJ, Kreuzer MP, Quidant R (2014) LSPR chip for parallel, rapid, and sensitive detection of cancer markers in serum. Nano Lett 14:2636–2641CrossRef Aćimović SS, Ortega MA, Sanz V, Berthelot J, Garcia-Cordero JL, Renger J, Maerkl SJ, Kreuzer MP, Quidant R (2014) LSPR chip for parallel, rapid, and sensitive detection of cancer markers in serum. Nano Lett 14:2636–2641CrossRef
39.
Zurück zum Zitat Ertürk G, Özen H, Tümer MA, Mattiasson B, Denizli A (2016) Microcontact imprinting based surface plasmon resonance (SPR) biosensor for real-time and ultrasensitive detection of prostate specific antigen (PSA) from clinical samples. Sensors Actuators B Chem 224:823–832CrossRef Ertürk G, Özen H, Tümer MA, Mattiasson B, Denizli A (2016) Microcontact imprinting based surface plasmon resonance (SPR) biosensor for real-time and ultrasensitive detection of prostate specific antigen (PSA) from clinical samples. Sensors Actuators B Chem 224:823–832CrossRef
40.
Zurück zum Zitat Uludag Y, Tothill IE (2012) Cancer biomarker detection in serum samples using surface plasmon resonance and quartz crystal microbalance sensors with nanoparticle signal amplification. Anal Chem 84:5898–5904CrossRef Uludag Y, Tothill IE (2012) Cancer biomarker detection in serum samples using surface plasmon resonance and quartz crystal microbalance sensors with nanoparticle signal amplification. Anal Chem 84:5898–5904CrossRef
41.
Zurück zum Zitat Türkoğlu EA, Yavuz H, Uzun L, Akgöl S, Denizli A (2013) The fabrication of nanosensor-based surface plasmon resonance for IgG detection. Artif Cells Nanomed Biotechnol 41:213–221CrossRef Türkoğlu EA, Yavuz H, Uzun L, Akgöl S, Denizli A (2013) The fabrication of nanosensor-based surface plasmon resonance for IgG detection. Artif Cells Nanomed Biotechnol 41:213–221CrossRef
42.
Zurück zum Zitat Ertürk G, Uzun L, Tümer MA, Say R, Denizli A (2011) Fab fragments imprinted SPR biosensor for real-time human immunoglobulin G detection. Biosens Bioelectron 28(1):97–104CrossRef Ertürk G, Uzun L, Tümer MA, Say R, Denizli A (2011) Fab fragments imprinted SPR biosensor for real-time human immunoglobulin G detection. Biosens Bioelectron 28(1):97–104CrossRef
43.
Zurück zum Zitat Dibekkaya H, Saylan Y, Yılmaz F, Derazshamshir A, Denizli A (2016) Surface plasmon resonance sensors for real-time detection of cyclic citrullinated peptide antibodies. J Macromol Sci, Part A: Pure Appl Chem 53:585–594CrossRef Dibekkaya H, Saylan Y, Yılmaz F, Derazshamshir A, Denizli A (2016) Surface plasmon resonance sensors for real-time detection of cyclic citrullinated peptide antibodies. J Macromol Sci, Part A: Pure Appl Chem 53:585–594CrossRef
44.
Zurück zum Zitat Chung JW, Kim SD, Bernhardt R, Pyun JC (2005) Application of SPR biosensor for medical diagnostics of human hepatitis B virus (hHBV). Sensors Actuators B Chem 111(112):416–422CrossRef Chung JW, Kim SD, Bernhardt R, Pyun JC (2005) Application of SPR biosensor for medical diagnostics of human hepatitis B virus (hHBV). Sensors Actuators B Chem 111(112):416–422CrossRef
45.
Zurück zum Zitat Uzun L, Say R, Ünal S, Denizli A (2009) Production of surface plasmon resonance based assay kit for hepatitis diagnosis. Biosens Bioelectron 24:2878–2884CrossRef Uzun L, Say R, Ünal S, Denizli A (2009) Production of surface plasmon resonance based assay kit for hepatitis diagnosis. Biosens Bioelectron 24:2878–2884CrossRef
46.
Zurück zum Zitat Lu J, Stappen TV, Spasic D, Delport F, Vermeire S, Gils A, Lammertyn J (2016) Fiber optic-SPR platform for fast and sensitive infliximab detection in serum of inflammatory bowel disease patients. Biosens Bioelectron 79:173–179CrossRef Lu J, Stappen TV, Spasic D, Delport F, Vermeire S, Gils A, Lammertyn J (2016) Fiber optic-SPR platform for fast and sensitive infliximab detection in serum of inflammatory bowel disease patients. Biosens Bioelectron 79:173–179CrossRef
47.
Zurück zum Zitat Ramanaviciene A, German N, Kausaite-Minkstimiene A, Voronovic J, Kirlyte J, Ramanavicius A (2012) Electrochemical and electroassisted chemiluminescence methods based immunosensor for the determination of antibodies against human growth hormone were performed as comparative studies by surface plasmon resonance. Biosens Bioelectron 36:48–55CrossRef Ramanaviciene A, German N, Kausaite-Minkstimiene A, Voronovic J, Kirlyte J, Ramanavicius A (2012) Electrochemical and electroassisted chemiluminescence methods based immunosensor for the determination of antibodies against human growth hormone were performed as comparative studies by surface plasmon resonance. Biosens Bioelectron 36:48–55CrossRef
48.
Zurück zum Zitat Im H, Shao H, Park YI, Peterson VM, Castro CM, Weissleder R, Lee H (2014) Label-free detection and molecular profiling of exosomes with a nanoplasmonic sensor. Nat Biotechnol 32(5):490–495CrossRef Im H, Shao H, Park YI, Peterson VM, Castro CM, Weissleder R, Lee H (2014) Label-free detection and molecular profiling of exosomes with a nanoplasmonic sensor. Nat Biotechnol 32(5):490–495CrossRef
49.
Zurück zum Zitat He L, Pagneux Q, Larroulet I, Serrano AY, Pesquera A, Zurutuza A, Mandler D, Boukherroub R, Szunerits S (2017) Label-free femtomolar cancer biomarker detection in human serum using graphene-coated surface plasmon resonance chips. Biosens Bioelectron 89:606–611CrossRef He L, Pagneux Q, Larroulet I, Serrano AY, Pesquera A, Zurutuza A, Mandler D, Boukherroub R, Szunerits S (2017) Label-free femtomolar cancer biomarker detection in human serum using graphene-coated surface plasmon resonance chips. Biosens Bioelectron 89:606–611CrossRef
50.
Zurück zum Zitat Liang RP, Yao GH, Fan LX, Qiu JD (2012) Magnetic Fe3O4@Au composite-enhanced surface plasmon resonance for ultrasensitive detection of magnetic nanoparticle-enriched α-fetoprotein. Anal Chim Acta 737:22–28CrossRef Liang RP, Yao GH, Fan LX, Qiu JD (2012) Magnetic Fe3O4@Au composite-enhanced surface plasmon resonance for ultrasensitive detection of magnetic nanoparticle-enriched α-fetoprotein. Anal Chim Acta 737:22–28CrossRef
51.
Zurück zum Zitat Osman B, Uzun L, Beşirli N, Denizli A (2013) Microcontact imprinted surface plasmon resonance sensor for myoglobin detection. Mater Sci Eng C 33:3609–3614CrossRef Osman B, Uzun L, Beşirli N, Denizli A (2013) Microcontact imprinted surface plasmon resonance sensor for myoglobin detection. Mater Sci Eng C 33:3609–3614CrossRef
52.
Zurück zum Zitat Sener G, Uzun L, Say R, Denizli A (2011) Use of molecular imprinted nanoparticles as biorecognition element on surface plasmon resonance sensor. Sensors Actuators B Chem 160:791–799CrossRef Sener G, Uzun L, Say R, Denizli A (2011) Use of molecular imprinted nanoparticles as biorecognition element on surface plasmon resonance sensor. Sensors Actuators B Chem 160:791–799CrossRef
53.
Zurück zum Zitat Bocková M, Song XC, Gedeonová E, Levová K, Kalousová M, Zima T, Homola J (2016) Surface plasmon resonance biosensor for detection of pregnancy associated plasma protein A2 in clinical samples. Anal Bioanal Chem 408(26):7265–7269CrossRef Bocková M, Song XC, Gedeonová E, Levová K, Kalousová M, Zima T, Homola J (2016) Surface plasmon resonance biosensor for detection of pregnancy associated plasma protein A2 in clinical samples. Anal Bioanal Chem 408(26):7265–7269CrossRef
54.
Zurück zum Zitat Murakami K, Tokuda M, Suzuki T, Irie Y, Hanaki M, Izuo N, Monobe Y, Akagi K-i, Ishii R, Tatebe H, Tokuda T, Maeda M, Kume T, Shimizu T, Irie K (2016) Monoclonal antibody with conformational specificity for a toxic conformer of amyloid β42 and its application toward the Alzheimer’s disease diagnosis. Sci Rep 6:29038–29050CrossRef Murakami K, Tokuda M, Suzuki T, Irie Y, Hanaki M, Izuo N, Monobe Y, Akagi K-i, Ishii R, Tatebe H, Tokuda T, Maeda M, Kume T, Shimizu T, Irie K (2016) Monoclonal antibody with conformational specificity for a toxic conformer of amyloid β42 and its application toward the Alzheimer’s disease diagnosis. Sci Rep 6:29038–29050CrossRef
55.
Zurück zum Zitat Sankiewicz A, Romanowicz L, Laudanski P, Zelazowska-Rutkowska B, Puzan B, Cylwik B, Gorodkiewicz E (2016) SPR imaging biosensor for determination of laminin-5 as a potential cancer marker in biological material. Anal Bioanal Chem 408:5269–5276CrossRef Sankiewicz A, Romanowicz L, Laudanski P, Zelazowska-Rutkowska B, Puzan B, Cylwik B, Gorodkiewicz E (2016) SPR imaging biosensor for determination of laminin-5 as a potential cancer marker in biological material. Anal Bioanal Chem 408:5269–5276CrossRef
56.
Zurück zum Zitat Brun APL, Soliakov A, Shah DSH, Holt SA, McGill A, Lakey JH (2015) Engineered self-assembling monolayers for label free detection of influenza nucleoprotein. Biomed Microdevices 17:49–59CrossRef Brun APL, Soliakov A, Shah DSH, Holt SA, McGill A, Lakey JH (2015) Engineered self-assembling monolayers for label free detection of influenza nucleoprotein. Biomed Microdevices 17:49–59CrossRef
57.
Zurück zum Zitat Liu Y, Liu Q, Chen S, Cheng F, Wang H, Peng W (2015) Surface plasmon resonance biosensor based on smart phone platforms. Sci Rep 5:12864–12873CrossRef Liu Y, Liu Q, Chen S, Cheng F, Wang H, Peng W (2015) Surface plasmon resonance biosensor based on smart phone platforms. Sci Rep 5:12864–12873CrossRef
58.
Zurück zum Zitat Sener G, Ozgur E, Rad AY, Uzun L, Say R, Denizli A (2013) Rapid real-time detection of procalcitonin using a microcontact imprinted surface plasmon resonance biosensor. Analyst 138:422–428CrossRef Sener G, Ozgur E, Rad AY, Uzun L, Say R, Denizli A (2013) Rapid real-time detection of procalcitonin using a microcontact imprinted surface plasmon resonance biosensor. Analyst 138:422–428CrossRef
59.
Zurück zum Zitat Mariani S, Minunni M (2014) Surface plasmon resonance applications in clinical analysis. Anal Bioanal Chem 406:2303–2323CrossRef Mariani S, Minunni M (2014) Surface plasmon resonance applications in clinical analysis. Anal Bioanal Chem 406:2303–2323CrossRef
60.
Zurück zum Zitat Cenci L, Andreetto E, Vestri A, Bovi M, Barozzi M, Iacob E, Busato M, Castagna A, Girelli D, Bossi AM (2015) Surface plasmon resonance based on molecularly imprinted nanoparticles for the picomolar detection of the iron regulating hormone Hepcidin-25. J Nanobiotechnol 13:51–66CrossRef Cenci L, Andreetto E, Vestri A, Bovi M, Barozzi M, Iacob E, Busato M, Castagna A, Girelli D, Bossi AM (2015) Surface plasmon resonance based on molecularly imprinted nanoparticles for the picomolar detection of the iron regulating hormone Hepcidin-25. J Nanobiotechnol 13:51–66CrossRef
61.
Zurück zum Zitat Zhang Q, Jing L, Zhang J, Ren Y, Wang Y, Wang Y, Wei T, Liedberg B (2014) Surface plasmon resonance sensor for femtomolar detection of testosterone with water-compatible macroporous molecularly imprinted film. Anal Biochem 463:7–14CrossRef Zhang Q, Jing L, Zhang J, Ren Y, Wang Y, Wang Y, Wei T, Liedberg B (2014) Surface plasmon resonance sensor for femtomolar detection of testosterone with water-compatible macroporous molecularly imprinted film. Anal Biochem 463:7–14CrossRef
62.
Zurück zum Zitat Vashist SK, Marion Schneider E, Barth E, Luong JHT (2016) Surface plasmon resonance-based immunoassay for procalcitonin. Anal Chim Acta 938:129–136CrossRef Vashist SK, Marion Schneider E, Barth E, Luong JHT (2016) Surface plasmon resonance-based immunoassay for procalcitonin. Anal Chim Acta 938:129–136CrossRef
63.
Zurück zum Zitat Treviño J, Calle A, Rodríguez-Frade JM, Mellado M, Lechuga LM (2009) Single- and multi-analyte determination of gonadotropic hormones in urine by surface plasmon resonance immunoassay. Anal Chim Acta 647:202–209CrossRef Treviño J, Calle A, Rodríguez-Frade JM, Mellado M, Lechuga LM (2009) Single- and multi-analyte determination of gonadotropic hormones in urine by surface plasmon resonance immunoassay. Anal Chim Acta 647:202–209CrossRef
64.
Zurück zum Zitat Treviño J, Calle A, Rodríguez-Frade JM, Mellado M, Lechuga LM (2009) Surface plasmon resonance immunoassay analysis of pituitary hormones in urine and serum samples. Clin Chim Acta 403:56–62CrossRef Treviño J, Calle A, Rodríguez-Frade JM, Mellado M, Lechuga LM (2009) Surface plasmon resonance immunoassay analysis of pituitary hormones in urine and serum samples. Clin Chim Acta 403:56–62CrossRef
65.
Zurück zum Zitat Srivastava SK, Verma R, Gupta BD, Khalaila I, Abdulhalim I (2015) SPR based fiber optic sensor for the detection of vitellogenin: an endocrine disruption biomarker in aquatic environments. Biosens J 4:1–5CrossRef Srivastava SK, Verma R, Gupta BD, Khalaila I, Abdulhalim I (2015) SPR based fiber optic sensor for the detection of vitellogenin: an endocrine disruption biomarker in aquatic environments. Biosens J 4:1–5CrossRef
66.
Zurück zum Zitat Yockell-Lelièvre H, Bukar N, McKeating KS, Arnaud M, Cosin P, Guo Y, Dupret-Carruel J, Mouginb B, Masson JF (2015) Plasmonic sensors for the competitive detection of testosterone. Analyst 140:5105–5112CrossRef Yockell-Lelièvre H, Bukar N, McKeating KS, Arnaud M, Cosin P, Guo Y, Dupret-Carruel J, Mouginb B, Masson JF (2015) Plasmonic sensors for the competitive detection of testosterone. Analyst 140:5105–5112CrossRef
67.
Zurück zum Zitat Sanghera N, Anderson A, Nuar N, Xie C, Mitchell D, Klein-Seetharaman J (2017) Insulin biosensor development: a case study. Int J Parallel Emergent Distrib Syst 32(1):119–138CrossRef Sanghera N, Anderson A, Nuar N, Xie C, Mitchell D, Klein-Seetharaman J (2017) Insulin biosensor development: a case study. Int J Parallel Emergent Distrib Syst 32(1):119–138CrossRef
68.
Zurück zum Zitat Sharon E, Freeman R, Riskin M, Gil N, Tzfati Y, Willner I (2010) Optical, electrical and surface plasmon resonance methods for detecting telomerase activity. Anal Chem 82:8390–8397CrossRef Sharon E, Freeman R, Riskin M, Gil N, Tzfati Y, Willner I (2010) Optical, electrical and surface plasmon resonance methods for detecting telomerase activity. Anal Chem 82:8390–8397CrossRef
69.
Zurück zum Zitat Diltemiz SE, Denizli A, Ersöz A, Say R (2008) Molecularly imprinted ligand-exchange recognition assay of DNA by SPR system using guanosine and guanine recognition sites of DNA. Sensors Actuators B Chem 133:484–488CrossRef Diltemiz SE, Denizli A, Ersöz A, Say R (2008) Molecularly imprinted ligand-exchange recognition assay of DNA by SPR system using guanosine and guanine recognition sites of DNA. Sensors Actuators B Chem 133:484–488CrossRef
70.
Zurück zum Zitat Bini A, Mascini M, Mascini M, Turner APF (2011) Selection of thrombin-binding aptamers by using computational approach for aptasensor application. Biosens Bioelectron 26:4411–4416CrossRef Bini A, Mascini M, Mascini M, Turner APF (2011) Selection of thrombin-binding aptamers by using computational approach for aptasensor application. Biosens Bioelectron 26:4411–4416CrossRef
71.
Zurück zum Zitat Kaur G, Paliwal A, Tomar M, Gupta V (2016) Detection of Neisseria meningitidis using surface plasmon resonance based DNA biosensor. Biosens Bioelectron 78:106–110CrossRef Kaur G, Paliwal A, Tomar M, Gupta V (2016) Detection of Neisseria meningitidis using surface plasmon resonance based DNA biosensor. Biosens Bioelectron 78:106–110CrossRef
72.
Zurück zum Zitat Gifford LK, Sendroiu IE, Corn RM, Luptak A (2010) Attomole detection of mesophilic DNA polymerase products by nanoparticle-enhanced surface plasmon resonance imaging on glassified gold surfaces. J Am Chem Soc 132:9265–9267CrossRef Gifford LK, Sendroiu IE, Corn RM, Luptak A (2010) Attomole detection of mesophilic DNA polymerase products by nanoparticle-enhanced surface plasmon resonance imaging on glassified gold surfaces. J Am Chem Soc 132:9265–9267CrossRef
73.
Zurück zum Zitat D’Agata R, Breveglieri G, Zanoli LM, Borgatti M, Spoto G, Gambari R (2011) Direct detection of point mutations in nonamplified human genomic DNA. Anal Chem 83:8711–8717CrossRef D’Agata R, Breveglieri G, Zanoli LM, Borgatti M, Spoto G, Gambari R (2011) Direct detection of point mutations in nonamplified human genomic DNA. Anal Chem 83:8711–8717CrossRef
74.
Zurück zum Zitat Cho H, Yeh EC, Sinha R, Laurence T, Bearinger J, Lee L (2012) Single-step nanoplasmonic VEGF165 aptasensor for early cancer diagnosis. ACS Nano 6:7607–7614CrossRef Cho H, Yeh EC, Sinha R, Laurence T, Bearinger J, Lee L (2012) Single-step nanoplasmonic VEGF165 aptasensor for early cancer diagnosis. ACS Nano 6:7607–7614CrossRef
75.
Zurück zum Zitat Jahanshahi P, Zalnezhad E, Sekaran SD, Adikan FRM (2014) Rapid immunoglobulin M-based dengue diagnostic test using surface plasmon resonance biosensor. Sci Rep 4:3851–3858CrossRef Jahanshahi P, Zalnezhad E, Sekaran SD, Adikan FRM (2014) Rapid immunoglobulin M-based dengue diagnostic test using surface plasmon resonance biosensor. Sci Rep 4:3851–3858CrossRef
76.
Zurück zum Zitat Altintas Z, Pocock J, Thompson KA, Tothill IE (2015) Comparative investigations for adenovirus recognition and quantification: plastic or natural antibodies? Biosens Bioelectron 74:996–1004CrossRef Altintas Z, Pocock J, Thompson KA, Tothill IE (2015) Comparative investigations for adenovirus recognition and quantification: plastic or natural antibodies? Biosens Bioelectron 74:996–1004CrossRef
77.
Zurück zum Zitat Basso CR, Tozato CC, Ribeiro MCM, Junior JPA, Pedros VA (2013) A immunosensor for the diagnosis of canine distemper virus infection using SPR and EIS. Anal Methods 5:5089–5096CrossRef Basso CR, Tozato CC, Ribeiro MCM, Junior JPA, Pedros VA (2013) A immunosensor for the diagnosis of canine distemper virus infection using SPR and EIS. Anal Methods 5:5089–5096CrossRef
78.
Zurück zum Zitat Bai H, Wang R, Hargis B, Lu H, Li Y (2012) A SPR aptasensor for detection of avian influenza virus H5N1. Sensors 12:12506–12518CrossRef Bai H, Wang R, Hargis B, Lu H, Li Y (2012) A SPR aptasensor for detection of avian influenza virus H5N1. Sensors 12:12506–12518CrossRef
79.
Zurück zum Zitat Diltemiz SE, Ersöz A, Hür D, Keçili R, Say R (2013) 4-Aminophenyl boronic acid modified gold platforms for influenza diagnosis. Mater Sci Eng C 33:824–830CrossRef Diltemiz SE, Ersöz A, Hür D, Keçili R, Say R (2013) 4-Aminophenyl boronic acid modified gold platforms for influenza diagnosis. Mater Sci Eng C 33:824–830CrossRef
80.
Zurück zum Zitat Altintas Z, Gittens M, Guerreiro A, Thompson KA, Walker J, Piletsky S, Tothill IE (2015) Detection of waterborne viruses using high affinity molecularly imprinted polymers. Anal Chem 87:6801–6807CrossRef Altintas Z, Gittens M, Guerreiro A, Thompson KA, Walker J, Piletsky S, Tothill IE (2015) Detection of waterborne viruses using high affinity molecularly imprinted polymers. Anal Chem 87:6801–6807CrossRef
81.
Zurück zum Zitat Riedel T, Rodriguez-Emmenegger C, Santos Pereira A, Bědajánková A, Jinoch P, Boltovets PM, Brynda E (2014) Diagnosis of Epstein–Barr virus infection in clinical serum samples by an SPR biosensor assay. Biosens Bioelectron 55:278–284CrossRef Riedel T, Rodriguez-Emmenegger C, Santos Pereira A, Bědajánková A, Jinoch P, Boltovets PM, Brynda E (2014) Diagnosis of Epstein–Barr virus infection in clinical serum samples by an SPR biosensor assay. Biosens Bioelectron 55:278–284CrossRef
82.
Zurück zum Zitat Yilmaz E, Majidi D, Ozgur E, Denizli A (2015) Whole cell imprinting based Escherichia Coli sensors: a study for SPR and QCM. Sensors Actuators B Chem 209:714–721CrossRef Yilmaz E, Majidi D, Ozgur E, Denizli A (2015) Whole cell imprinting based Escherichia Coli sensors: a study for SPR and QCM. Sensors Actuators B Chem 209:714–721CrossRef
83.
Zurück zum Zitat Wang Y, Ye Z, Si C, Ying Y (2011) Subtractive inhibition assay for the detection of E. coli O157:H7 using surface plasmon resonance. Sensors 11:2728–2739CrossRef Wang Y, Ye Z, Si C, Ying Y (2011) Subtractive inhibition assay for the detection of E. coli O157:H7 using surface plasmon resonance. Sensors 11:2728–2739CrossRef
84.
Zurück zum Zitat Karoonuthaisiri N, Charlermroj R, Morton MJ, Oplatowska-Stachowiak M, Grant IR, Elliott CT (2014) Development of a M13 bacteriophage-based SPR detection using Salmonella as a case study. Sensors Actuators B Chem 190:214–220CrossRef Karoonuthaisiri N, Charlermroj R, Morton MJ, Oplatowska-Stachowiak M, Grant IR, Elliott CT (2014) Development of a M13 bacteriophage-based SPR detection using Salmonella as a case study. Sensors Actuators B Chem 190:214–220CrossRef
85.
Zurück zum Zitat Arya SK, Singh A, Naidoo R, Wu P, McDermott MT, Evoy S (2011) Chemically immobilized T4-bacteriophage for specific Escherichia coli detection using surface plasmon resonance. Analyst 136:486–492CrossRef Arya SK, Singh A, Naidoo R, Wu P, McDermott MT, Evoy S (2011) Chemically immobilized T4-bacteriophage for specific Escherichia coli detection using surface plasmon resonance. Analyst 136:486–492CrossRef
86.
Zurück zum Zitat Kuo YC, Ho JH, Yen TJ, Chen HF, Lee OKS (2011) Development of a surface plasmon resonance biosensor for real-time detection of osteogenic differentiation in live mesenchymal stem cells. PLoS One 6(7):e22382–e22389CrossRef Kuo YC, Ho JH, Yen TJ, Chen HF, Lee OKS (2011) Development of a surface plasmon resonance biosensor for real-time detection of osteogenic differentiation in live mesenchymal stem cells. PLoS One 6(7):e22382–e22389CrossRef
87.
Zurück zum Zitat Yanase Y, Hiragun T, Yanase T, Kawaguchi T, Ishii K, Hide M (2013) Application of SPR imaging sensor for detection of individual living cell reactions and clinical diagnosis of type I allergy. Allergol Int 62:163–169CrossRef Yanase Y, Hiragun T, Yanase T, Kawaguchi T, Ishii K, Hide M (2013) Application of SPR imaging sensor for detection of individual living cell reactions and clinical diagnosis of type I allergy. Allergol Int 62:163–169CrossRef
88.
Zurück zum Zitat Yanase Y, Hiragun T, Yanase T, Kawaguchi T, Ishii K, Kumazaki N, Obara T, Hide M (2014) Clinical diagnosis of type I allergy by means of SPR imaging with less than a microliter of peripheral blood. Sens Bio-Sens Res 2:43–48CrossRef Yanase Y, Hiragun T, Yanase T, Kawaguchi T, Ishii K, Kumazaki N, Obara T, Hide M (2014) Clinical diagnosis of type I allergy by means of SPR imaging with less than a microliter of peripheral blood. Sens Bio-Sens Res 2:43–48CrossRef
89.
Zurück zum Zitat Altintas Z, France B, Ortiz JO, Tothill IE (2016) Computationally modelled receptors for drug monitoring using an optical based biomimetic SPR sensor. Sensors Actuators B Chem 224:726–737CrossRef Altintas Z, France B, Ortiz JO, Tothill IE (2016) Computationally modelled receptors for drug monitoring using an optical based biomimetic SPR sensor. Sensors Actuators B Chem 224:726–737CrossRef
90.
Zurück zum Zitat Altintas Z, Guerreiro A, Piletsky SA, Tothill IE (2015) NanoMIP based optical sensor for pharmaceuticals monitoring. Sensors Actuators B Chem 213:305–313CrossRef Altintas Z, Guerreiro A, Piletsky SA, Tothill IE (2015) NanoMIP based optical sensor for pharmaceuticals monitoring. Sensors Actuators B Chem 213:305–313CrossRef
91.
Zurück zum Zitat Yockell-Lelièvre H, Bukar N, Toulouse JL, Pelletiera JN, Masson JF (2016) Naked-eye nanobiosensor for therapeutic drug monitoring of methotrexate. Analyst 141:697–703CrossRef Yockell-Lelièvre H, Bukar N, Toulouse JL, Pelletiera JN, Masson JF (2016) Naked-eye nanobiosensor for therapeutic drug monitoring of methotrexate. Analyst 141:697–703CrossRef
92.
Zurück zum Zitat Pernites RB, Ponnapati RR, Felipe MJ, Advincula RC (2011) Electropolymerization molecularly imprinted polymer (E-MIP) SPR sensing of drug molecules: pre-polymerization complexed terthiophene and carbazole electroactive monomers. Biosens Bioelectron 26:2766–2771CrossRef Pernites RB, Ponnapati RR, Felipe MJ, Advincula RC (2011) Electropolymerization molecularly imprinted polymer (E-MIP) SPR sensing of drug molecules: pre-polymerization complexed terthiophene and carbazole electroactive monomers. Biosens Bioelectron 26:2766–2771CrossRef
93.
Zurück zum Zitat Pernites RB, Ponnapati RR, Advincula RC (2010) Surface plasmon resonance (SPR) detection of theophylline via electropolymerized molecularly imprinted polythiophenes. Macromolecules 43:9724–9735CrossRef Pernites RB, Ponnapati RR, Advincula RC (2010) Surface plasmon resonance (SPR) detection of theophylline via electropolymerized molecularly imprinted polythiophenes. Macromolecules 43:9724–9735CrossRef
94.
Zurück zum Zitat Golub E, Pelossof G, Freeman R, Zhang H, Willner I (2009) Electrochemical, photoelectrochemical, and surface plasmon resonance detection of cocaine using supramolecular aptamer complexes and metallic or semiconductor nanoparticles. Anal Chem 81:9291–9298CrossRef Golub E, Pelossof G, Freeman R, Zhang H, Willner I (2009) Electrochemical, photoelectrochemical, and surface plasmon resonance detection of cocaine using supramolecular aptamer complexes and metallic or semiconductor nanoparticles. Anal Chem 81:9291–9298CrossRef
95.
Zurück zum Zitat Wang Y, Zhang C, Zhang Y, Fang H, Min C, Zhu S, Yuan XC (2015) Investigation of phase SPR biosensor for efficient targeted drug screening with high sensitivity and stability. Sensors Actuators B Chem 209:313–322CrossRef Wang Y, Zhang C, Zhang Y, Fang H, Min C, Zhu S, Yuan XC (2015) Investigation of phase SPR biosensor for efficient targeted drug screening with high sensitivity and stability. Sensors Actuators B Chem 209:313–322CrossRef
96.
Zurück zum Zitat Wang Y, Zhang S, Zhang C, Zhao Z, Zheng X, Xue L, Liu J, Yuan XC (2016) Investigation of an SPR biosensor for determining the influence of connexin 43 expression on the cytotoxicity of cisplatin. Analyst 141:3411–3421CrossRef Wang Y, Zhang S, Zhang C, Zhao Z, Zheng X, Xue L, Liu J, Yuan XC (2016) Investigation of an SPR biosensor for determining the influence of connexin 43 expression on the cytotoxicity of cisplatin. Analyst 141:3411–3421CrossRef
97.
Zurück zum Zitat Sari E, Üzek R, Duman M, Denizli A (2016) Fabrication of surface plasmon resonance nanosensor for the selective determination of erythromycin via molecular imprinted nanoparticles. Talanta 150:607–614CrossRef Sari E, Üzek R, Duman M, Denizli A (2016) Fabrication of surface plasmon resonance nanosensor for the selective determination of erythromycin via molecular imprinted nanoparticles. Talanta 150:607–614CrossRef
Metadaten
Titel
Surface Plasmon Resonance Sensors for Medical Diagnosis
verfasst von
Yeşeren Saylan
Fatma Yılmaz
Erdoğan Özgür
Ali Derazshamshir
Nilay Bereli
Handan Yavuz
Adil Denizli
Copyright-Jahr
2018
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-662-56333-5_10

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.