Abstract

The measurement of joint angles is an important indicator of its functional state and for clinical diagnoses. Joint angle assessment techniques can be applied to improve sports performance and provide treatment and rehabilitation information. Recently, several sensors have been designed to detect movements of the human body. In this sense, a systematic review was carried out based on studies from the period of 2014 to 2019. The sources of research were the following databases: Capes Journals, IEEE Xplore and PubMed, in which 44 publications related to technologies applied for elbow joint angle measurements were selected. Eleven measurement methods were identified, the most used was: IMU sensors, mobile apps and fiber optic sensors. The results show that it is an area in constant expansion, with most of the papers published in recent years and with great potential for development and applications. The benefits of research can go far beyond indicating the sensors most used in the literature, but provide the most suitable for each application. In addition to facilitating the standardization of assessment methods for use in clinical practice. It is worth mentioning that the literature review has identified the main gaps for the development of new research, in addition to direct the main publications related to the study.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Cheng P, Oelmann B (2010) Joint-angle measurement using accelerometers and gyroscopes—a survey. IEEE Trans Instrum Meas Cheng P, Oelmann B (2010) Joint-angle measurement using accelerometers and gyroscopes—a survey. IEEE Trans Instrum Meas
2.
Zurück zum Zitat Rezende A, Alves C, Marques I, Silva MA, Naves E (2018) Polymer optical fiber goniometer: a new portable, low cost and reliable sensor for joint analysis. Sensors 18(12):4293 Rezende A, Alves C, Marques I, Silva MA, Naves E (2018) Polymer optical fiber goniometer: a new portable, low cost and reliable sensor for joint analysis. Sensors 18(12):4293
3.
Zurück zum Zitat Bolus NB, Kogler GF, Inan OT (2016) A novel method to assess angle sensor performance for wearable exoskeletal joint kinematics. In: Proceedings of the annual international conference of the IEEE engineering in medicine and biology society, EMBS Bolus NB, Kogler GF, Inan OT (2016) A novel method to assess angle sensor performance for wearable exoskeletal joint kinematics. In: Proceedings of the annual international conference of the IEEE engineering in medicine and biology society, EMBS
4.
Zurück zum Zitat Barakat C et al (2019) The effects of varying glenohumeral joint angle on acute volume load, muscle activation, swelling, and echo-intensity on the biceps brachii in resistance-trained individuals. Sports Barakat C et al (2019) The effects of varying glenohumeral joint angle on acute volume load, muscle activation, swelling, and echo-intensity on the biceps brachii in resistance-trained individuals. Sports
5.
Zurück zum Zitat Umesh S, Padma S, Srinivas T, Asokan S (2018) Fiber bragg grating goniometer for joint angle measurement. IEEE Sens J Umesh S, Padma S, Srinivas T, Asokan S (2018) Fiber bragg grating goniometer for joint angle measurement. IEEE Sens J
6.
Zurück zum Zitat Du YC, Shih CB, Fan SC, Lin HT, Chen PJ (2018) An IMU-compensated skeletal tracking system using Kinect for the upper limb. Microsyst Technol Du YC, Shih CB, Fan SC, Lin HT, Chen PJ (2018) An IMU-compensated skeletal tracking system using Kinect for the upper limb. Microsyst Technol
7.
Zurück zum Zitat Wang W, Wang D, Wesseling M, Xue B, Li F (2019) Comparison of modelling and tracking methods for analysing elbow and forearm kinematics. Proc Inst Mech Eng Part H J Eng Med Wang W, Wang D, Wesseling M, Xue B, Li F (2019) Comparison of modelling and tracking methods for analysing elbow and forearm kinematics. Proc Inst Mech Eng Part H J Eng Med
8.
Zurück zum Zitat Vauclair F et al (2018) The smartphone inclinometer: a new tool to determine elbow range of motion? Eur J Orthop Surg Traumatol Vauclair F et al (2018) The smartphone inclinometer: a new tool to determine elbow range of motion? Eur J Orthop Surg Traumatol
9.
Zurück zum Zitat Öhberg F, Bäcklund T, Sundström N, Grip H (2019) Portable sensors add reliable kinematic measures to the assessment of upper extremity function. Sensors (Switzerland) Öhberg F, Bäcklund T, Sundström N, Grip H (2019) Portable sensors add reliable kinematic measures to the assessment of upper extremity function. Sensors (Switzerland)
10.
Zurück zum Zitat Callejas-Cuervo M, Gutierrez RM, Hernandez AI (2017) Joint amplitude MEMS based measurement platform for low cost and high accessibility telerehabilitation: elbow case study. J Bodywork Mov Ther Callejas-Cuervo M, Gutierrez RM, Hernandez AI (2017) Joint amplitude MEMS based measurement platform for low cost and high accessibility telerehabilitation: elbow case study. J Bodywork Mov Ther
11.
Zurück zum Zitat Santospagnuolo A et al (2019) Validity and reliability of the GYKO inertial sensor system for the assessment of the elbow range of motion. J Sports Med Phys Fitness 59(9):1466–1471 Santospagnuolo A et al (2019) Validity and reliability of the GYKO inertial sensor system for the assessment of the elbow range of motion. J Sports Med Phys Fitness 59(9):1466–1471
12.
Zurück zum Zitat Morrow MMB, Lowndes B, Fortune E, Kaufman KR, Hallbeck MS (2017) Validation of inertial measurement units for upper body kinematics. J Appl Biomech Morrow MMB, Lowndes B, Fortune E, Kaufman KR, Hallbeck MS (2017) Validation of inertial measurement units for upper body kinematics. J Appl Biomech
13.
Zurück zum Zitat Schiefer C, Kraus T, Ellegast RP, Ochsmann E (2015) A technical support tool for joint range of motion determination in functional diagnostics—an inter-rater study. J Occup Med Toxicol Schiefer C, Kraus T, Ellegast RP, Ochsmann E (2015) A technical support tool for joint range of motion determination in functional diagnostics—an inter-rater study. J Occup Med Toxicol
14.
Zurück zum Zitat Sacco G et al (2015) Inertial sensors as measurement tools of elbow range of motion in gerontology. Clin Interv Aging Sacco G et al (2015) Inertial sensors as measurement tools of elbow range of motion in gerontology. Clin Interv Aging
15.
Zurück zum Zitat Álvarez D, Alvarez JC, González RC, López AM (2016) Upper limb joint angle measurement in occupational health. Comput Methods Biomech Biomed Eng Álvarez D, Alvarez JC, González RC, López AM (2016) Upper limb joint angle measurement in occupational health. Comput Methods Biomech Biomed Eng
16.
Zurück zum Zitat Bouvier B, Duprey S, Claudon L, Dumas R, Savescu A (2015) Upper limb kinematics using inertial and magnetic sensors: comparison of sensor-to-segment calibrations. Sensors (Switzerland) Bouvier B, Duprey S, Claudon L, Dumas R, Savescu A (2015) Upper limb kinematics using inertial and magnetic sensors: comparison of sensor-to-segment calibrations. Sensors (Switzerland)
17.
Zurück zum Zitat Zabat M, Ababou A, Ababou N, Dumas R (2019) IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement—a proof of concept. Med Biol Eng Comput Zabat M, Ababou A, Ababou N, Dumas R (2019) IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement—a proof of concept. Med Biol Eng Comput
18.
Zurück zum Zitat Atrsaei A, Salarieh H, Alasty A, Abediny M (2018) Human arm motion tracking by inertial/magnetic sensors using unscented Kalman filter and relative motion constraint. J Intell Robot Syst Theory Appl Atrsaei A, Salarieh H, Alasty A, Abediny M (2018) Human arm motion tracking by inertial/magnetic sensors using unscented Kalman filter and relative motion constraint. J Intell Robot Syst Theory Appl
19.
Zurück zum Zitat Ruiz-Olaya AF, Callejas-Cuervo M, Lara-Herrera CN (2017) Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion DYNA Ruiz-Olaya AF, Callejas-Cuervo M, Lara-Herrera CN (2017) Wearable low-cost inertial sensor-based electrogoniometer for measuring joint range of motion DYNA
20.
Zurück zum Zitat Laidig D, Müller P, Seel T (2017) Automatic anatomical calibration for IMU-based elbow angle measurement in disturbed magnetic fields. Curr Dir Biomed Eng Laidig D, Müller P, Seel T (2017) Automatic anatomical calibration for IMU-based elbow angle measurement in disturbed magnetic fields. Curr Dir Biomed Eng
21.
Zurück zum Zitat Muller P, Begin MA, Schauer T, Seel T (2017) Alignment-free, self-calibrating elbow angles measurement using inertial sensors. IEEE J Biomed Heal Inform Muller P, Begin MA, Schauer T, Seel T (2017) Alignment-free, self-calibrating elbow angles measurement using inertial sensors. IEEE J Biomed Heal Inform
22.
Zurück zum Zitat Joukov V, Cesic J, Westermann K, Markovic I, Kulic D, Petrovic I (2017) Human motion estimation on Lie groups using IMU measurements. In: IEEE international conference on intelligent robots and systems Joukov V, Cesic J, Westermann K, Markovic I, Kulic D, Petrovic I (2017) Human motion estimation on Lie groups using IMU measurements. In: IEEE international conference on intelligent robots and systems
23.
Zurück zum Zitat Jacob A, Wan Zakaria WN, Bin Md Tomari MR (2017) Implementation of IMU sensor for elbow movement measurement of Badminton players. In: 2016 2nd IEEE international symposium on robotics and manufacturing automation, ROMA 2016 Jacob A, Wan Zakaria WN, Bin Md Tomari MR (2017) Implementation of IMU sensor for elbow movement measurement of Badminton players. In: 2016 2nd IEEE international symposium on robotics and manufacturing automation, ROMA 2016
24.
Zurück zum Zitat Doğan M et al (2019) Functional range of motion in the upper extremity and trunk joints: nine functional everyday tasks with inertial sensors. Gait Posture Doğan M et al (2019) Functional range of motion in the upper extremity and trunk joints: nine functional everyday tasks with inertial sensors. Gait Posture
25.
Zurück zum Zitat Little K et al (2019) IMU-based assistance modulation in upper limb soft wearable exosuits. In: IEEE international conference on rehabilitation robotics Little K et al (2019) IMU-based assistance modulation in upper limb soft wearable exosuits. In: IEEE international conference on rehabilitation robotics
26.
Zurück zum Zitat Ramos MM, Carnaz L, Mattiello SM, Karduna AR, Zanca GG (2019) Shoulder and elbow joint position sense assessment using a mobile app in subjects with and without shoulder pain—between-days reliability. Phys Ther Sport Ramos MM, Carnaz L, Mattiello SM, Karduna AR, Zanca GG (2019) Shoulder and elbow joint position sense assessment using a mobile app in subjects with and without shoulder pain—between-days reliability. Phys Ther Sport
27.
Zurück zum Zitat Keijsers R et al (2018) Validity and reliability of elbow range of motion measurements using digital photographs, movies, and a goniometry smartphone application. J Sports Med Keijsers R et al (2018) Validity and reliability of elbow range of motion measurements using digital photographs, movies, and a goniometry smartphone application. J Sports Med
28.
Zurück zum Zitat Meislin MA, Wagner ER, Shin AY (2016) A comparison of elbow range of motion measurements: smartphone-based digital photography versus goniometric measurements. J Hand Surg Am Meislin MA, Wagner ER, Shin AY (2016) A comparison of elbow range of motion measurements: smartphone-based digital photography versus goniometric measurements. J Hand Surg Am
29.
Zurück zum Zitat Cruz J, Morais N (2016) Intrarater agreement of elbow extension range of motion in the upper limb neurodynamic test 1 using a smartphone application. Arch Phys Med Rehabil Cruz J, Morais N (2016) Intrarater agreement of elbow extension range of motion in the upper limb neurodynamic test 1 using a smartphone application. Arch Phys Med Rehabil
30.
Zurück zum Zitat Leal-Junior AG, Frizera A, Avellar LM, Pontes MJ (2018) Design considerations, analysis, and application of a low-cost, fully portable, wearable polymer optical fiber curvature sensor. Appl Opt Leal-Junior AG, Frizera A, Avellar LM, Pontes MJ (2018) Design considerations, analysis, and application of a low-cost, fully portable, wearable polymer optical fiber curvature sensor. Appl Opt
31.
Zurück zum Zitat Jang M, Kim JS, Kang K, Um SH, Yang S, Kim J (2019) Development of wearable motion capture system using fiber bragg grating sensors for measuring arm motion. In: 26th IEEE conference on virtual reality and 3D user interfaces, VR 2019—proceedings Jang M, Kim JS, Kang K, Um SH, Yang S, Kim J (2019) Development of wearable motion capture system using fiber bragg grating sensors for measuring arm motion. In: 26th IEEE conference on virtual reality and 3D user interfaces, VR 2019—proceedings
32.
Zurück zum Zitat D’Mello Y, Skoric J, Moukarzel L, Hakim S, Plant DV (2019) Wearable fiber optic sensors for biomechanical sensing via joint angle detection. In: Proceedings of the annual international conference of the IEEE engineering in medicine and biology society, EMBS D’Mello Y, Skoric J, Moukarzel L, Hakim S, Plant DV (2019) Wearable fiber optic sensors for biomechanical sensing via joint angle detection. In: Proceedings of the annual international conference of the IEEE engineering in medicine and biology society, EMBS
33.
Zurück zum Zitat Ştefan AM, Popescu D, Ichim L (2019) Upper limb orthosis—image analysis for elbow range of motion. In: 2019 11th International symposium on advanced topics in electrical engineering, ATEE 2019 Ştefan AM, Popescu D, Ichim L (2019) Upper limb orthosis—image analysis for elbow range of motion. In: 2019 11th International symposium on advanced topics in electrical engineering, ATEE 2019
34.
Zurück zum Zitat Russo RR et al (2018) Is digital photography an accurate and precise method for measuring range of motion of the shoulder and elbow? J Orthop Sci Russo RR et al (2018) Is digital photography an accurate and precise method for measuring range of motion of the shoulder and elbow? J Orthop Sci
35.
Zurück zum Zitat Mateo F et al (2019) Assessment of Kinect V2 for elbow range of motion estimation in people with haemophilia using an angle correction model. Haemophilia Mateo F et al (2019) Assessment of Kinect V2 for elbow range of motion estimation in people with haemophilia using an angle correction model. Haemophilia
36.
Zurück zum Zitat Hawi N et al (2014) Range of motion assessment of the shoulder and elbow joints using a motion sensing input device: a pilot study. Technol Heal Care Hawi N et al (2014) Range of motion assessment of the shoulder and elbow joints using a motion sensing input device: a pilot study. Technol Heal Care
37.
Zurück zum Zitat Schlagenhauf F, Sreeram S, Singhose W (2018) Comparison of Kinect and Vicon motion capture of upper-body joint angle tracking. In: IEEE international conference on control and automation, ICCA Schlagenhauf F, Sreeram S, Singhose W (2018) Comparison of Kinect and Vicon motion capture of upper-body joint angle tracking. In: IEEE international conference on control and automation, ICCA
38.
Zurück zum Zitat RenHe L, Wongkittisuksa B (2017) The evaluation of elbow joint motion using bio-impedance signal. In: ECTI-CON 2017–2017 14th International conference on electrical engineering/electronics, computer, telecommunications and information technology RenHe L, Wongkittisuksa B (2017) The evaluation of elbow joint motion using bio-impedance signal. In: ECTI-CON 2017–2017 14th International conference on electrical engineering/electronics, computer, telecommunications and information technology
39.
Zurück zum Zitat Mamikoglu U, Nikolakopoulos G, Pauelsen M, Varagnolo D, Röijezon U, Gustafsson T (2016) Elbow joint angle estimation by using integrated surface electromyography. In: 24th Mediterranean conference on control and automation, MED 2016 Mamikoglu U, Nikolakopoulos G, Pauelsen M, Varagnolo D, Röijezon U, Gustafsson T (2016) Elbow joint angle estimation by using integrated surface electromyography. In: 24th Mediterranean conference on control and automation, MED 2016
40.
Zurück zum Zitat Triwiyanto, Wahyunggoro O, Nugroho HA, Herianto (2018) Upper limb elbow joint angle estimation based on electromyography using artificial neural network. In: Proceedings—12th SEATUC symposium, SEATUC 2018 Triwiyanto, Wahyunggoro O, Nugroho HA, Herianto (2018) Upper limb elbow joint angle estimation based on electromyography using artificial neural network. In: Proceedings—12th SEATUC symposium, SEATUC 2018
41.
Zurück zum Zitat Fieseler G et al (2015) Intrarater reliability of goniometry and hand-held dynamometry for shoulder and elbow examinations in female team handball athletes and asymptomatic volunteers. Arch Orthop Trauma Surg Fieseler G et al (2015) Intrarater reliability of goniometry and hand-held dynamometry for shoulder and elbow examinations in female team handball athletes and asymptomatic volunteers. Arch Orthop Trauma Surg
42.
Zurück zum Zitat Resende T et al (2017) Universal goniometer and smartphone app for evaluation of elbow joint motion: reproducibility analysis. In: International conference on virtual rehabilitation, ICVR Resende T et al (2017) Universal goniometer and smartphone app for evaluation of elbow joint motion: reproducibility analysis. In: International conference on virtual rehabilitation, ICVR
43.
Zurück zum Zitat Behnoush B et al (2016) Smartphone and universal goniometer for measurement of elbow joint motions: a comparative study. Asian J Sports Med Behnoush B et al (2016) Smartphone and universal goniometer for measurement of elbow joint motions: a comparative study. Asian J Sports Med
44.
Zurück zum Zitat Chen XM, Barma S, Pun SH, Vai MI, Mak PU (2017) Direct measurement of elbow joint angle using galvanic couple system. IEEE Trans Instrum Meas Chen XM, Barma S, Pun SH, Vai MI, Mak PU (2017) Direct measurement of elbow joint angle using galvanic couple system. IEEE Trans Instrum Meas
45.
Zurück zum Zitat Wu JF et al (2018) Human limb motion detection with novel flexible capacitive angle sensor based on conductive textile. Electron Wu JF et al (2018) Human limb motion detection with novel flexible capacitive angle sensor based on conductive textile. Electron
46.
Zurück zum Zitat Qi Y, Soh CB, Gunawan E, Low KS, Maskooki A (2014) A novel approach to joint flexion/extension angles measurement based on wearable UWB radios. IEEE J Biomed Heal Inform Qi Y, Soh CB, Gunawan E, Low KS, Maskooki A (2014) A novel approach to joint flexion/extension angles measurement based on wearable UWB radios. IEEE J Biomed Heal Inform
47.
Zurück zum Zitat Qi Y, Soh CB, Gunawan E, Low KS (2014) A wearable wireless ultrasonic sensor network for human arm motion tracking. In: 2014 36th Annual international conference of the IEEE engineering in medicine and biology society, EMBC 2014 Qi Y, Soh CB, Gunawan E, Low KS (2014) A wearable wireless ultrasonic sensor network for human arm motion tracking. In: 2014 36th Annual international conference of the IEEE engineering in medicine and biology society, EMBC 2014
48.
Zurück zum Zitat Chan M, Estève D, Fourniols JY, Escriba C, Campo E (2012) Smart wearable systems: current status and future challenges. Artif Intell Med Chan M, Estève D, Fourniols JY, Escriba C, Campo E (2012) Smart wearable systems: current status and future challenges. Artif Intell Med
Metadaten
Titel
Technologies Applied for Elbow Joint Angle Measurements: A Systematic Review
verfasst von
A. R. Rezende
C. M. Alves
I. A. Marques
D. C. Silva
T. S. Paiva
E. L. M. Naves
Copyright-Jahr
2022
DOI
https://doi.org/10.1007/978-3-030-70601-2_39

Neuer Inhalt