Skip to main content
Erschienen in: Fire Technology 1/2021

19.05.2020

The Ceiling Height Limits for Water Mist Protection of Two Solid Combustible Fire Hazards in Open Environment

verfasst von: Hong-Zeng Yu

Erschienen in: Fire Technology | Ausgabe 1/2021

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

CEN and NFPA have expanded the application of water mist in open environments from light solid combustible fire hazards to several in the higher hazard categories. A previous analysis and test evaluation showed that such application expansion is feasible, provided that the water mist spray meets droplet size and application density requirements for the intended fire challenge. However, this evaluation was performed exclusively for water mist sprays discharging at 1.65 m above the burning combustibles. This led to the question of whether the water mist protection could still be effective for larger clearances of nozzle discharge above the combustibles. Therefore, a series of fire tests was conducted subsequently to determine the ceiling height limits for both deluge and automatic nozzle protections. As for the previous evaluation, the two tested fire challenges were a 2-tier (2.74 m) high rack-storage of corrugated cardboard cartons on wood pallets, and a palletized storage of cartoned expanded polystyrene up to 1.68 m high. Both fire challenges were in the CEN OH-3 category, and respectively represented fire hazards in the FM Global HC-2 and HC-3 categories, which in turn corresponded to the NFPA OH-1 and OH-2 fire hazards. Each water mist spray discharged 76 l/min at 16.5 bar, with a volume median droplet diameter of around 220 µm. The nozzles were spaced 3.05 × 3.05 m to provide a designated application density of 8.1 mm/min. Quick-response thermal sensors, with an activation temperature of 74°C and a response index of 27.6 (m s)1/2, were employed to initiate the nozzle discharge. The tests showed that the deluge protection is applicable to both fire challenges for ceiling heights up to 9.1 m. However, for the automatic nozzle protection, the ceiling height limit is reduced to 6.1 m, with a water supply requirement of providing 17 nozzle operations for a safety factor of about 50% over the maximum number of nozzle operations observed in the tests.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat CEN/TS 14972 (2011) Fixed firefighting systems—water mist systems—design and installation. European Committee for Standardization, Brussels CEN/TS 14972 (2011) Fixed firefighting systems—water mist systems—design and installation. European Committee for Standardization, Brussels
2.
Zurück zum Zitat EN 14972-2 (2017) Fixed firefighting systems—water mist systems—part 2: test protocol for shopping areas for automatic nozzle systems. European Committee for Standardization, Brussels EN 14972-2 (2017) Fixed firefighting systems—water mist systems—part 2: test protocol for shopping areas for automatic nozzle systems. European Committee for Standardization, Brussels
3.
Zurück zum Zitat EN 14972-4 (2017) Fixed firefighting systems—water mist systems—part 4: test protocol for non-storage occupancies for automatic nozzle systems. European Committee for Standardization, Brussels EN 14972-4 (2017) Fixed firefighting systems—water mist systems—part 4: test protocol for non-storage occupancies for automatic nozzle systems. European Committee for Standardization, Brussels
4.
Zurück zum Zitat DFL Nr. 61204-03 (2014) Rack storage with in rack protection. Fire test method for water mist systems. Danish Fire Laboratories, Svendborg DFL Nr. 61204-03 (2014) Rack storage with in rack protection. Fire test method for water mist systems. Danish Fire Laboratories, Svendborg
5.
Zurück zum Zitat NFPA 750 (2015) Standard on water mist fire protection systems. National Fire Protection Association, Quincy NFPA 750 (2015) Standard on water mist fire protection systems. National Fire Protection Association, Quincy
6.
Zurück zum Zitat UL 2167 (2011) Water mist nozzles for fire protection service. Underwriters Laboratories, Northbrook UL 2167 (2011) Water mist nozzles for fire protection service. Underwriters Laboratories, Northbrook
7.
Zurück zum Zitat NFPA 13 (2019) Standard for the installation of sprinkler systems. National Fire Protection Association, Quincy NFPA 13 (2019) Standard for the installation of sprinkler systems. National Fire Protection Association, Quincy
8.
Zurück zum Zitat Yu H-Z, Liu X (2019) An efficacy evaluation of water mist protection against solid combustible fires in open environment. Fire Technol 55:343–361CrossRef Yu H-Z, Liu X (2019) An efficacy evaluation of water mist protection against solid combustible fires in open environment. Fire Technol 55:343–361CrossRef
9.
Zurück zum Zitat DS 3-26 (2019) Fire protection for nonstorage occupancies. FM Global, Norwood DS 3-26 (2019) Fire protection for nonstorage occupancies. FM Global, Norwood
10.
Zurück zum Zitat ASME Boiler and Pressure Vessel Code (2010) Section II part D: properties (metric) materials. The American Society of Mechanical Engineers, New York ASME Boiler and Pressure Vessel Code (2010) Section II part D: properties (metric) materials. The American Society of Mechanical Engineers, New York
11.
Zurück zum Zitat Nam S, Braga A, Kung H-C, Troup JMA (2002) Fire protection for non-storage occupancies with high clearance clearances. In: Proceedings of the 7th international symposium on fire safety science, pp 493–504 Nam S, Braga A, Kung H-C, Troup JMA (2002) Fire protection for non-storage occupancies with high clearance clearances. In: Proceedings of the 7th international symposium on fire safety science, pp 493–504
Metadaten
Titel
The Ceiling Height Limits for Water Mist Protection of Two Solid Combustible Fire Hazards in Open Environment
verfasst von
Hong-Zeng Yu
Publikationsdatum
19.05.2020
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 1/2021
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-020-00992-0

Weitere Artikel der Ausgabe 1/2021

Fire Technology 1/2021 Zur Ausgabe