Abstract

The operating principle of immunochromatographic test systems is considered. It is noted that with the use of such tests an immunoassay is implemented as a sandwich method in the form of a direct dependence of the luminescence of test stripes on the concentration of the test substance or as a competitive method with an inverse dependence. An experimental procedure of obtaining such dependences, which is necessary for the construction of calibration curves, is set forth. Exponential expressions for arriving at an analytic description of the associated curves are proposed; moreover, the coefficients in these expressions are determined by the method of least squares. An analysis of the error of the method of calibration curves that may be used to obtain quantitative results of the analysis is presented.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Fußnoten
1
See Fig. 1 of the article “Metrological assurance of systems of rapid medical diagnosis” by S. S. Golubev et al., Metrologiya, No. 10, 8 (2012).
 
Literatur
1.
Zurück zum Zitat B. B. Dzantiev and A. V. Zherdev, Immunoassay Methods. Problems of Analytic Chemistry, Vol. 12, Biochemical Methods of Assay [in Russian], B. B. Dzantiev (ed.), Nauka, Moscow (2010). B. B. Dzantiev and A. V. Zherdev, Immunoassay Methods. Problems of Analytic Chemistry, Vol. 12, Biochemical Methods of Assay [in Russian], B. B. Dzantiev (ed.), Nauka, Moscow (2010).
2.
Zurück zum Zitat R. Wong and H. Tse (eds.), Lateral Flow Immunoassay, Humana Press, New York (2009). R. Wong and H. Tse (eds.), Lateral Flow Immunoassay, Humana Press, New York (2009).
3.
Zurück zum Zitat T. A. Starovoytova et al., “An analytic platform for conducting biochemical and immunological studies in a micro-matrix format with digital camera recording,” Biomed. Zh. Medline.ru, 11, 44– 62 (2010). T. A. Starovoytova et al., “An analytic platform for conducting biochemical and immunological studies in a micro-matrix format with digital camera recording,” Biomed. Zh. Medline.ru, 11, 44– 62 (2010).
4.
Zurück zum Zitat FR.1.39.2011.11003, Measurement Technique. Determination of Calibration Curves of Immunochromatographic Test Systems, Comprising Test Systems with Direct and Inverse Dependence of the Detected Signal on the Concentration of the Test Compound. FR.1.39.2011.11003, Measurement Technique. Determination of Calibration Curves of Immunochromatographic Test Systems, Comprising Test Systems with Direct and Inverse Dependence of the Detected Signal on the Concentration of the Test Compound.
5.
Zurück zum Zitat GOST 8.207–76, GSI. Direct Measurements with Multiple Observations. Methods of Processing Results of Observations. Basic Assumptions. GOST 8.207–76, GSI. Direct Measurements with Multiple Observations. Methods of Processing Results of Observations. Basic Assumptions.
6.
Zurück zum Zitat L. A. Semenov and T. N. Siraya, Methods for the Construction of Calibration Characteristics of Measuring Instruments [in Russian], Izd. Standartov, Moscow (1986). L. A. Semenov and T. N. Siraya, Methods for the Construction of Calibration Characteristics of Measuring Instruments [in Russian], Izd. Standartov, Moscow (1986).
7.
Zurück zum Zitat R 50.2.028–2003, GSI. Algorithms for the Construction of Calibration Characteristics of Instruments Used for the Measurement of the Composition of Substances and Synthetic Materials and Estimation of Their Errors (uncertainties). Estimation of the Error (uncertainty) of Linear Calibration Characteristics with the Use of the Method of Least Squares. R 50.2.028–2003, GSI. Algorithms for the Construction of Calibration Characteristics of Instruments Used for the Measurement of the Composition of Substances and Synthetic Materials and Estimation of Their Errors (uncertainties). Estimation of the Error (uncertainty) of Linear Calibration Characteristics with the Use of the Method of Least Squares.
8.
Zurück zum Zitat GOST R 8.563–2009. GSI. Measurement Techniques (methods). GOST R 8.563–2009. GSI. Measurement Techniques (methods).
9.
Zurück zum Zitat N. V. Svezhova et al., “Methods of mathematical processing of data in immunoenzymatic assay. Part 1. Theoretical foundations,” Klin. Lab. Diagn., No. 1, 13–22 (2008). N. V. Svezhova et al., “Methods of mathematical processing of data in immunoenzymatic assay. Part 1. Theoretical foundations,” Klin. Lab. Diagn., No. 1, 13–22 (2008).
10.
Zurück zum Zitat N. V. Svezhova et al., “Methods of mathematical processing of data in immunoenzymatic assay. Part II. Comparative estimation of mathematical methods of processing the data of immunoenzymatic assay,” Klin. Lab. Diagn., No. 1, 23–36 (2008). N. V. Svezhova et al., “Methods of mathematical processing of data in immunoenzymatic assay. Part II. Comparative estimation of mathematical methods of processing the data of immunoenzymatic assay,” Klin. Lab. Diagn., No. 1, 23–36 (2008).
11.
Zurück zum Zitat D. S. Hage et al., “Development of a theoretical model for chromatographic-based competitive binding immunoassays with simultaneous injection of sample and lable,” Anal. Chem., No. 71 (15), 2965–2975 (1999). D. S. Hage et al., “Development of a theoretical model for chromatographic-based competitive binding immunoassays with simultaneous injection of sample and lable,” Anal. Chem., No. 71 (15), 2965–2975 (1999).
12.
Zurück zum Zitat J. W. Findlay and R. F. Dillard, “Appropriate calibration curve fitting in ligand binding assays,” J. AAPS, No. 9 (2), Art. 29, E260–E267 (2007). J. W. Findlay and R. F. Dillard, “Appropriate calibration curve fitting in ligand binding assays,” J. AAPS, No. 9 (2), Art. 29, E260–E267 (2007).
13.
Zurück zum Zitat G. I. Bell and C. P. DeLisi, “Antigen binding to receptors on immunocompetent cells: I. Simple models and interpretation of experiments,” Cell. Immunology, No. 10 (3), 415–431 (1974). G. I. Bell and C. P. DeLisi, “Antigen binding to receptors on immunocompetent cells: I. Simple models and interpretation of experiments,” Cell. Immunology, No. 10 (3), 415–431 (1974).
14.
Zurück zum Zitat B. Goldstein and M. Dembo, “Approximating the effects of diffusion on reversible reactions at the cell surface: ligandreceptor kinetics,” Biophys. J., No. 68 (4), 1222–1230 (1995). B. Goldstein and M. Dembo, “Approximating the effects of diffusion on reversible reactions at the cell surface: ligandreceptor kinetics,” Biophys. J., No. 68 (4), 1222–1230 (1995).
15.
Zurück zum Zitat V. A. Kuznetsov, L. K. Isaev, and I. A. Shaiko, Metrology [in Russian], STANDART-INFORM (2005). V. A. Kuznetsov, L. K. Isaev, and I. A. Shaiko, Metrology [in Russian], STANDART-INFORM (2005).
Metadaten
Titel
The Method of Calibration Curves for Immunochromatographic Express Tests. Part 1. Immunochromatographic Express Tests with Colloidal Gold
verfasst von
S. S. Golubev
B. B. Dzantiev
A. V. Zherdev
Yu. V. Kiseleva
Ya. A. Korolenko
Yu. A. Kudeyarov
V. M. Malyuchenko
N. I. Smirnova
D. V. Sotnikov
Publikationsdatum
01.03.2013
Verlag
Springer US
Erschienen in
Measurement Techniques / Ausgabe 12/2013
Print ISSN: 0543-1972
Elektronische ISSN: 1573-8906
DOI
https://doi.org/10.1007/s11018-013-0144-y

Weitere Artikel der Ausgabe 12/2013

Measurement Techniques 12/2013 Zur Ausgabe