Skip to main content

2013 | OriginalPaper | Buchkapitel

5. Time Domain Dielectric Response Measurements

verfasst von : Sivaji Chakravorti, Debangshu Dey, Biswendu Chatterjee

Erschienen in: Recent Trends in the Condition Monitoring of Transformers

Verlag: Springer London

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In the past, conventional methods for condition monitoring (discussed in the previous chapter) have enabled power utilities to anticipate developing problems and plan maintenance activities accordingly. In recent past, new non-invasive diagnostic methods have been proposed which are complimentary to classical electrical measurements. These methods are based on measurement of dielectric response of transformer insulation in time domain, viz. measurement of polarization and depolarization currents (PDC) and recovery voltage measurement (RVM), or in frequency domain, i.e., frequency domain spectroscopy. This chapter elaborates the two methods of time domain dielectric response measurement—namely PDC and RVM.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Zaengl WS (2003) Dielectric spectroscopy in time and frequency domain for HV power equipment, part i: theoritical considerations. IEEE Electr Insul Mag 19(5):6–19CrossRef Zaengl WS (2003) Dielectric spectroscopy in time and frequency domain for HV power equipment, part i: theoritical considerations. IEEE Electr Insul Mag 19(5):6–19CrossRef
2.
Zurück zum Zitat Yao ZT, Saha TK, Darveniza M (1999) Effects of moisture on the recovery voltage measurement for aged transformer. In Proceedings of International Conference on Power Engineering, vol 1. pp. 349–353 Yao ZT, Saha TK, Darveniza M (1999) Effects of moisture on the recovery voltage measurement for aged transformer. In Proceedings of International Conference on Power Engineering, vol 1. pp. 349–353
3.
Zurück zum Zitat Gafvert U, Frimpong G, Fuhr J (1998) Modeling of dielectric measurements on power transformers. In Proceedings of CIGRE, Paris. Paper no. 15/103 Gafvert U, Frimpong G, Fuhr J (1998) Modeling of dielectric measurements on power transformers. In Proceedings of CIGRE, Paris. Paper no. 15/103
4.
Zurück zum Zitat Griffin PJ, SSokolov V, Vanin B (1999) Moisture equilibrium and moisture migration within transformer insulation system, CIGRE SC12 transformer colloquium, Budapeste. (Julho) Griffin PJ, SSokolov V, Vanin B (1999) Moisture equilibrium and moisture migration within transformer insulation system, CIGRE SC12 transformer colloquium, Budapeste. (Julho)
5.
Zurück zum Zitat Saha TK (2003) Review of time-domain polarization measurements for assessing insulation condition in aged transformers. IEEE Trans Power Delivery 18(4):1293–1301CrossRef Saha TK (2003) Review of time-domain polarization measurements for assessing insulation condition in aged transformers. IEEE Trans Power Delivery 18(4):1293–1301CrossRef
6.
Zurück zum Zitat Saha TK, Purkait P (2008) Investigations of temperature effects on the dielectric response measurements of transformer oil-paper insulation system. IEEE Trans Power Delivery 23(1):252–260CrossRef Saha TK, Purkait P (2008) Investigations of temperature effects on the dielectric response measurements of transformer oil-paper insulation system. IEEE Trans Power Delivery 23(1):252–260CrossRef
7.
Zurück zum Zitat Frimpong G, Gafvert U, Fuhr J (1997) Measurement and modeling of dielectric response of composite oil/paper insulation. In proceedings of 5th international conference of properties and applications of dielectric materials. Seoul, Korea, pp 86–89 Frimpong G, Gafvert U, Fuhr J (1997) Measurement and modeling of dielectric response of composite oil/paper insulation. In proceedings of 5th international conference of properties and applications of dielectric materials. Seoul, Korea, pp 86–89
8.
Zurück zum Zitat Koch M (2008) Reliable moisture determination in power transformers. Ph.D. thesis, Institute of energy transmission and high voltage engineering. University of Stuttgart, Sierke Verlag Göttingen, Germany Koch M (2008) Reliable moisture determination in power transformers. Ph.D. thesis, Institute of energy transmission and high voltage engineering. University of Stuttgart, Sierke Verlag Göttingen, Germany
9.
Zurück zum Zitat Kheng TC (2000) Impact of moisture on the strength of paper-insulated conductor. B.E Thesis, University of Queensland, Australia Kheng TC (2000) Impact of moisture on the strength of paper-insulated conductor. B.E Thesis, University of Queensland, Australia
10.
Zurück zum Zitat Gfiert U, Ildstad E (1994) Modelling return voltage measurements of multi-layer insulation systems, ICPADM 94. Brisbane Gfiert U, Ildstad E (1994) Modelling return voltage measurements of multi-layer insulation systems, ICPADM 94. Brisbane
11.
Zurück zum Zitat Leibfried T, Kachler AJ (2002) Insulation diagnostics on power transformers using the polarization and depolarization current (PDC) analysis. IEEE international symposium on electrical insulation, Boston, pp 170–173 Leibfried T, Kachler AJ (2002) Insulation diagnostics on power transformers using the polarization and depolarization current (PDC) analysis. IEEE international symposium on electrical insulation, Boston, pp 170–173
12.
Zurück zum Zitat Saha TK, Purkait P (2004) Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers. IEEE Trans Dielectr Electr Insul 11:144–154CrossRef Saha TK, Purkait P (2004) Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers. IEEE Trans Dielectr Electr Insul 11:144–154CrossRef
13.
Zurück zum Zitat Osvath P, Csepes G, Webb M (1992) Polarisation spectrum analysis for diagnosis of insulation systems. Sixth international conference on dielectric materials, measurements and applications, Manchester, pp 270–273 Osvath P, Csepes G, Webb M (1992) Polarisation spectrum analysis for diagnosis of insulation systems. Sixth international conference on dielectric materials, measurements and applications, Manchester, pp 270–273
14.
Zurück zum Zitat Dielectric response methods for diagnosis of power transformers. In Electra no. 202, 2002, CIGRE Task Force 15.01.09 Dielectric response methods for diagnosis of power transformers. In Electra no. 202, 2002, CIGRE Task Force 15.01.09
15.
Zurück zum Zitat Wei JL et al (2011) Novel characteristic parameters for oil-paper insulation assessment from differential time-domain spectroscopy based on polarization and depolarization current measurement. IEEE Trans Dielectr Electr Insul 18(6):1918–1928CrossRef Wei JL et al (2011) Novel characteristic parameters for oil-paper insulation assessment from differential time-domain spectroscopy based on polarization and depolarization current measurement. IEEE Trans Dielectr Electr Insul 18(6):1918–1928CrossRef
16.
Zurück zum Zitat Dey D, Chatterjee B, Chakravorti S, Munshi S (2007) A hybrid filtering scheme for proper denoising of real-time data in dielectric spectroscopy. IEEE Trans Dielectr Electr Insul 14(5):1323–1331 Dey D, Chatterjee B, Chakravorti S, Munshi S (2007) A hybrid filtering scheme for proper denoising of real-time data in dielectric spectroscopy. IEEE Trans Dielectr Electr Insul 14(5):1323–1331
17.
Zurück zum Zitat Yin L, Yang R, Gabbouj M, Neuvo Y (1996) Weighted Median Filters: A Tutorial. IEEE Trans Circuits Syst II Analog Digital Signal Process 43:157–192CrossRef Yin L, Yang R, Gabbouj M, Neuvo Y (1996) Weighted Median Filters: A Tutorial. IEEE Trans Circuits Syst II Analog Digital Signal Process 43:157–192CrossRef
18.
Zurück zum Zitat Arce GR (1998) A general weighted median filter structure admitting negative weights. IEEE Trans Signal Processing 46:3195–3205CrossRef Arce GR (1998) A general weighted median filter structure admitting negative weights. IEEE Trans Signal Processing 46:3195–3205CrossRef
19.
Zurück zum Zitat Arce GR, Paredes JL (2000) Recursive weighted median filters admitting negative weights and their optimization. IEEE Trans Signal Process 48:768–779CrossRef Arce GR, Paredes JL (2000) Recursive weighted median filters admitting negative weights and their optimization. IEEE Trans Signal Process 48:768–779CrossRef
20.
Zurück zum Zitat Proakis JG, Manolakis DG (1998) Digital signal processing: principles, algorithms, and applications. Prentice-Hall, New Jersey Proakis JG, Manolakis DG (1998) Digital signal processing: principles, algorithms, and applications. Prentice-Hall, New Jersey
21.
Zurück zum Zitat Bognar A, Kalocsai L, Csepes G, Nemeth E, Schmidt J (1990) Dielectric tests of high voltage oil paper insulating systems (in particular transformer Insulation) using DC dielectrometrics. In Proceedings of CIGRE, 33rd Session, Paris vol 2. pp 15/33–08 Bognar A, Kalocsai L, Csepes G, Nemeth E, Schmidt J (1990) Dielectric tests of high voltage oil paper insulating systems (in particular transformer Insulation) using DC dielectrometrics. In Proceedings of CIGRE, 33rd Session, Paris vol 2. pp 15/33–08
22.
Zurück zum Zitat Saha TK, Purkait P, Muller F (2005) Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements. IEEE Trans Power Del 20(1):149–157CrossRef Saha TK, Purkait P, Muller F (2005) Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements. IEEE Trans Power Del 20(1):149–157CrossRef
23.
Zurück zum Zitat Mohamed G, Németh E (1991) Computer simulation of dielectric processes. In Proceedings of 7th international symposium on high voltage engineering, Dresden. pp 309–331 Mohamed G, Németh E (1991) Computer simulation of dielectric processes. In Proceedings of 7th international symposium on high voltage engineering, Dresden. pp 309–331
24.
Zurück zum Zitat Jota PRS, Islam SM, Jota FG (1999) Modelling the polarisation in composite oil/paper insulation systems. IEEE Trans Dielectr Electr Insul 6(2):145–151CrossRef Jota PRS, Islam SM, Jota FG (1999) Modelling the polarisation in composite oil/paper insulation systems. IEEE Trans Dielectr Electr Insul 6(2):145–151CrossRef
25.
Zurück zum Zitat Urbani GM, Brooks RS (1998) Using the recovery voltage method to evaluate aging in oil-paper insulation. In Proceedings of IEEE international conference conduction breakdown in solid dielectrics, Vasteras. pp 93–97 Urbani GM, Brooks RS (1998) Using the recovery voltage method to evaluate aging in oil-paper insulation. In Proceedings of IEEE international conference conduction breakdown in solid dielectrics, Vasteras. pp 93–97
26.
Zurück zum Zitat Saha TK, Purkait P (2004) Investigation of an expert system for the condition assessment of transformer insulation based on dielectric response measurements. IEEE Trans Power Delivery 19(3):1127–1134CrossRef Saha TK, Purkait P (2004) Investigation of an expert system for the condition assessment of transformer insulation based on dielectric response measurements. IEEE Trans Power Delivery 19(3):1127–1134CrossRef
27.
Zurück zum Zitat Zaengl WS (2003) Dielectric spectroscopy in time and frequency domain for HV power equipment part I: theoretical considerations. IEEE Electr Insul Mag 19(5):5–19CrossRef Zaengl WS (2003) Dielectric spectroscopy in time and frequency domain for HV power equipment part I: theoretical considerations. IEEE Electr Insul Mag 19(5):5–19CrossRef
28.
Zurück zum Zitat Xu S, Middleton R, Fetherston F, Pantalone D (2003) A comparison of return voltage measurement and frequency domain spectroscopy test on high voltage insulation. In Proceedings of the 7th international conference on properties and applications of dielectric materials, Nagoya. 1-5 June 2003 Xu S, Middleton R, Fetherston F, Pantalone D (2003) A comparison of return voltage measurement and frequency domain spectroscopy test on high voltage insulation. In Proceedings of the 7th international conference on properties and applications of dielectric materials, Nagoya. 1-5 June 2003
29.
Zurück zum Zitat Csepes G, Hamos I, Brooks I, Karius V (1998) Practical foundations of the RVM (Recovery voltage method for oil/paper insulation diagnosis). In proceedings of IEEE conference on electrical insulation dielectric phenomena. pp 345–355 Csepes G, Hamos I, Brooks I, Karius V (1998) Practical foundations of the RVM (Recovery voltage method for oil/paper insulation diagnosis). In proceedings of IEEE conference on electrical insulation dielectric phenomena. pp 345–355
30.
Zurück zum Zitat Gubanski SM et al. (2006) Reliable diagnostics of hv transformer insulation for safety assurance of power transmission system, REDIATOOL—a european research project CIGRE D1-207. Paris Gubanski SM et al. (2006) Reliable diagnostics of hv transformer insulation for safety assurance of power transmission system, REDIATOOL—a european research project CIGRE D1-207. Paris
31.
Zurück zum Zitat der Houhanessian V, Zaengl WS (1998) On-site diagnosis of power transformers by means of relaxation current measurementsin Proc. IEEE Int Symp Electr Insul 1:28–34 der Houhanessian V, Zaengl WS (1998) On-site diagnosis of power transformers by means of relaxation current measurementsin Proc. IEEE Int Symp Electr Insul 1:28–34
32.
Zurück zum Zitat Gafvert U, Adeen L, Tapper M, Ghasemi P, Jonsson B (2000) Dielectric spectroscopy in time and frequency domain applied to diagnostics of power transformers. In proceedings of 6th international conference properties and applications of dielectric materials. vol 2, Xian. pp 825–830 Gafvert U, Adeen L, Tapper M, Ghasemi P, Jonsson B (2000) Dielectric spectroscopy in time and frequency domain applied to diagnostics of power transformers. In proceedings of 6th international conference properties and applications of dielectric materials. vol 2, Xian. pp 825–830
33.
Zurück zum Zitat Kachler AJ (2000) On-site diagnosis of power and special transformers. In Proceedings of IEEE International Symposium on Electrical Insulation. pp 362–367 Kachler AJ (2000) On-site diagnosis of power and special transformers. In Proceedings of IEEE International Symposium on Electrical Insulation. pp 362–367
34.
Zurück zum Zitat Saha TK, Purkait P, Yao ZT (2002) Condition monitoring of transformer insulation by polarization and depolarization current measurements. In proceedings of australasian universities power engineering conference, Melbourne Saha TK, Purkait P, Yao ZT (2002) Condition monitoring of transformer insulation by polarization and depolarization current measurements. In proceedings of australasian universities power engineering conference, Melbourne
35.
Zurück zum Zitat Hassig M, Braunlich R, Gysi R, Alff JJ, Der Houhanessian V, Zaengl WS (2001) On-site applications of advanced diagnosis methods for quality assessment of insulation of power transformers. In proceedings of conference electrical insulation and dielectric Phenomena, pp 441–447 Hassig M, Braunlich R, Gysi R, Alff JJ, Der Houhanessian V, Zaengl WS (2001) On-site applications of advanced diagnosis methods for quality assessment of insulation of power transformers. In proceedings of conference electrical insulation and dielectric Phenomena, pp 441–447
36.
Zurück zum Zitat Yao ZT, Saha TK (2002) Analysis and modeling of dielectric responses of power transformer insulation. In proceedings of IEEE power engineering society summer meeting, vol 1, Chicago. pp 417–421 Yao ZT, Saha TK (2002) Analysis and modeling of dielectric responses of power transformer insulation. In proceedings of IEEE power engineering society summer meeting, vol 1, Chicago. pp 417–421
37.
Zurück zum Zitat Bhumiwat S, Lowe S, Nething Ph, Wickramasuriya P, Kuansatit P (2010) Performance of oil and paper in transformers based on IEC 61620 and dielectric response techniques. IEEE Elec Insul Mag 26(3):16–23CrossRef Bhumiwat S, Lowe S, Nething Ph, Wickramasuriya P, Kuansatit P (2010) Performance of oil and paper in transformers based on IEC 61620 and dielectric response techniques. IEEE Elec Insul Mag 26(3):16–23CrossRef
38.
Zurück zum Zitat Li J, Chen M, Zheng F, Zhou Z (1997) Diffusion theory of slow responses. Science in China (Series A) 40(3):290–296 Li J, Chen M, Zheng F, Zhou Z (1997) Diffusion theory of slow responses. Science in China (Series A) 40(3):290–296
39.
Zurück zum Zitat Fofana I, Hemmatjou H, Meghnefi F (2011) Effect of thermal transient on the polarization and depolarization current measurements. IEEE Trans Dielectr Electr Insul 18(2):513–520 Fofana I, Hemmatjou H, Meghnefi F (2011) Effect of thermal transient on the polarization and depolarization current measurements. IEEE Trans Dielectr Electr Insul 18(2):513–520
Metadaten
Titel
Time Domain Dielectric Response Measurements
verfasst von
Sivaji Chakravorti
Debangshu Dey
Biswendu Chatterjee
Copyright-Jahr
2013
Verlag
Springer London