Thermal insulation and mechanical resistance play a crucial role for the performance of an intumescent coating. Both properties depend strongly on the morphology and morphological development of the foamed residue. Small amounts (4 wt%) of fiberglass, clay and a copper salt, respectively, are incorporated into an intumescent coating to study their influence on the morphology and performance of the residues. The bench scale fire tests were performed on 75 × 75 × 2 mm3 coated steel plates according to the standard time–temperature curve in the Standard Time Temperature Muffle Furnace+ (STT Mufu+). It provided information about foaming dynamics (expansion rates) and thermal insulation. Adding the copper salt halved the expansion height, whereas the clay and fiberglass change the height of the residue only moderately. The time to reach 500°C was improved by 31% for clay and 15% for the other two fillers. Nondestructive micro computed tomography is used to assess the inner structure of the residues. A transition of the residue from a black, carbonaceous foam with closed cells into an inorganic, residual open cell sponge occurs at high temperatures. This transition is due to a loss of carbon; the change in microstructure is analyzed by scanning electron microscopy. Additional mechanical tests are performed and interpreted with respect to the results of the morphology analysis. Adding clay or copper salt improved the mechanical resistance tested by a factor 4. The additives significantly influence the thickness and foaming dynamics as well as the inner structure of the residues, whereas their influence on insulation performance is moderate. In conclusion, different modes of action are observed to achieve similar insulation performance during the fire test.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Vandersall H (1971) Intumescent coating systems, their development and chemistry. J Fire Flammabil 2(2):97–140 Vandersall H (1971) Intumescent coating systems, their development and chemistry. J Fire Flammabil 2(2):97–140
7.
Zurück zum Zitat Hörold A, Schartel B, Trappe V, Gettwert V, Korzen M (2015) Protecting the structural integrity of composites in fire: intumescent coatings in the intermediate scale. J Reinf Plast Compos 34(24):2029–2044. doi:10.1177/0731684415609791 CrossRef Hörold A, Schartel B, Trappe V, Gettwert V, Korzen M (2015) Protecting the structural integrity of composites in fire: intumescent coatings in the intermediate scale. J Reinf Plast Compos 34(24):2029–2044. doi:10.​1177/​0731684415609791​ CrossRef
12.
Zurück zum Zitat Schuff W, Clar C, Kühnel P, Tramm H (1934) Feuersichere Überzüge ergebendes Anstrichmittel. Germany Patent Schuff W, Clar C, Kühnel P, Tramm H (1934) Feuersichere Überzüge ergebendes Anstrichmittel. Germany Patent
16.
Zurück zum Zitat Camino G, Costa L, Trossarelli L (1984) Study of the mechanism of intumescence in fire retardant polymers: part I—thermal degradation of ammonium polyphosphate-pentaerythritol mixtures. Polym Degrad Stab 6(4):243–252. doi:10.1016/0141-3910(84)90004-1 CrossRef Camino G, Costa L, Trossarelli L (1984) Study of the mechanism of intumescence in fire retardant polymers: part I—thermal degradation of ammonium polyphosphate-pentaerythritol mixtures. Polym Degrad Stab 6(4):243–252. doi:10.​1016/​0141-3910(84)90004-1 CrossRef
17.
Zurück zum Zitat Mesquita L, Piloto P, Vaz M, Pinto T (2009) Decomposition of intumescent coatings: comparison between a numerical method and experimental results. Acta Polytech 49(1):60–65 Mesquita L, Piloto P, Vaz M, Pinto T (2009) Decomposition of intumescent coatings: comparison between a numerical method and experimental results. Acta Polytech 49(1):60–65
20.
Zurück zum Zitat Staggs J (2010) Thermal conductivity estimates of intumescent chars by direct numerical simulation. Fire Saf J 45(4):228–237CrossRef Staggs J (2010) Thermal conductivity estimates of intumescent chars by direct numerical simulation. Fire Saf J 45(4):228–237CrossRef
22.
Zurück zum Zitat Li G-Q, Zhang C, Lou G-B, Wang Y-C, Wang L-L (2012) Assess the fire resistance of intumescent coatings by equivalent constant thermal resistance. Fire Technol 48(2):529–546. doi:10.1007/s10694-011-0243-8 CrossRef Li G-Q, Zhang C, Lou G-B, Wang Y-C, Wang L-L (2012) Assess the fire resistance of intumescent coatings by equivalent constant thermal resistance. Fire Technol 48(2):529–546. doi:10.​1007/​s10694-011-0243-8 CrossRef
23.
26.
Zurück zum Zitat Naik AD, Duquesne S, Bourbigot S (2016) Hydrocarbon time-temperature curve under airjet perturbation: an in situ method to probe char stability and integrity in reactive fire protection coatings. J Fire Sci. doi:10.1177/0734904116658049 Naik AD, Duquesne S, Bourbigot S (2016) Hydrocarbon time-temperature curve under airjet perturbation: an in situ method to probe char stability and integrity in reactive fire protection coatings. J Fire Sci. doi:10.​1177/​0734904116658049​
28.
Zurück zum Zitat Morys M, Illerhaus B, Sturm H, Schartel B (2016) Revealing the inner secrets of intumescence: Advanced standard time temperature oven (STT Mufu +)—μ-computed tomography approach. Fire Mater (submitted) Morys M, Illerhaus B, Sturm H, Schartel B (2016) Revealing the inner secrets of intumescence: Advanced standard time temperature oven (STT Mufu +)—μ-computed tomography approach. Fire Mater (submitted)
31.
33.
Zurück zum Zitat Jimenez M, Duquesne S, Bourbigot S (2006) Multiscale experimental approach for developing high-performance intumescent coatings. Ind Eng Chem Res 45(13):4500–4508. doi:10.1021/ie060040x CrossRef Jimenez M, Duquesne S, Bourbigot S (2006) Multiscale experimental approach for developing high-performance intumescent coatings. Ind Eng Chem Res 45(13):4500–4508. doi:10.​1021/​ie060040x CrossRef
34.
Zurück zum Zitat Bartholmai M, Schartel B (2007) Assessing the performance of intumescent coatings using bench-scaled cone calorimeter and finite difference simulations. Fire Mater 31(3):187–205. doi:10.1002/Fam.933 CrossRef Bartholmai M, Schartel B (2007) Assessing the performance of intumescent coatings using bench-scaled cone calorimeter and finite difference simulations. Fire Mater 31(3):187–205. doi:10.​1002/​Fam.​933 CrossRef
35.
Zurück zum Zitat Bartholmai M, Schriever R, Schartel B (2003) Influence of external heat flux and coating thickness on the thermal insulation properties of two different intumescent coatings using cone calorimeter and numerical analysis. Fire Mater 27(4):151–162. doi:10.1002/Fam.823 CrossRef Bartholmai M, Schriever R, Schartel B (2003) Influence of external heat flux and coating thickness on the thermal insulation properties of two different intumescent coatings using cone calorimeter and numerical analysis. Fire Mater 27(4):151–162. doi:10.​1002/​Fam.​823 CrossRef
36.
37.
Zurück zum Zitat Amir N, Abd Majid AA, Ahmad F (2016) Effects of hybrid fibre reinforcement on fire resistance performance and char morphology of intumescent coating. In: Karim ZAA, Baharudin ZH, Basrawi MF, Rahman MM, Noor MM (eds) Utp-ump symposium on energy systems 2015, vol 38. MATEC Web of Conferences. doi:10.1051/matecconf/20163803001 Amir N, Abd Majid AA, Ahmad F (2016) Effects of hybrid fibre reinforcement on fire resistance performance and char morphology of intumescent coating. In: Karim ZAA, Baharudin ZH, Basrawi MF, Rahman MM, Noor MM (eds) Utp-ump symposium on energy systems 2015, vol 38. MATEC Web of Conferences. doi:10.​1051/​matecconf/​20163803001
38.
Zurück zum Zitat Amir N, Ahmad F, Megat-Yusoff PSM (2012) Char strength of wool fibre reinforced epoxy-based intumescent coatings (FRIC). In: Abdullah MMA, Jamaludin L, Razak RA, Yahya Z, Hussin K (eds) Advanced materials engineering and technology, vol 626. Advanced Materials Research, pp 504–508. doi:10.4028/www.scientific.net/AMR.626.504 Amir N, Ahmad F, Megat-Yusoff PSM (2012) Char strength of wool fibre reinforced epoxy-based intumescent coatings (FRIC). In: Abdullah MMA, Jamaludin L, Razak RA, Yahya Z, Hussin K (eds) Advanced materials engineering and technology, vol 626. Advanced Materials Research, pp 504–508. doi:10.​4028/​www.​scientific.​net/​AMR.​626.​504
39.
Zurück zum Zitat Aziz H, Ahmad F, Yusoff P, Zia-Ul-Mustafa M (2014) Effect of kaolin clay and alumina on thermal performance and char morphology of intumescent fire retardant coating. In: Karuppanan S, Karim ZAA, Ovinis M, Baheta AT (eds) Icper 2014—4th international conference on production, energy and reliability, vol 13. MATEC Web of Conferences Aziz H, Ahmad F, Yusoff P, Zia-Ul-Mustafa M (2014) Effect of kaolin clay and alumina on thermal performance and char morphology of intumescent fire retardant coating. In: Karuppanan S, Karim ZAA, Ovinis M, Baheta AT (eds) Icper 2014—4th international conference on production, energy and reliability, vol 13. MATEC Web of Conferences
43.
44.
45.
Zurück zum Zitat CEN (1999) EN 1363-1: 1999-10: Feuerwiderstandsprüfungen–Allgemeine Anforderungen CEN (1999) EN 1363-1: 1999-10: Feuerwiderstandsprüfungen–Allgemeine Anforderungen
47.
Zurück zum Zitat Brehme S, Schartel B, Goebbels J, Fischer O, Pospiech D, Bykov Y, Döring M (2011) Phosphorus polyester versus aluminium phosphinate in poly(butylene terephthalate) (PBT): flame retardancy performance and mechanisms. Polym Degrad Stab 96(5):875–884. doi:10.1016/j.polymdegradstab.2011.01.035 CrossRef Brehme S, Schartel B, Goebbels J, Fischer O, Pospiech D, Bykov Y, Döring M (2011) Phosphorus polyester versus aluminium phosphinate in poly(butylene terephthalate) (PBT): flame retardancy performance and mechanisms. Polym Degrad Stab 96(5):875–884. doi:10.​1016/​j.​polymdegradstab.​2011.​01.​035 CrossRef
48.
49.
Zurück zum Zitat Goebbels J, Illerhaus B, Onel Y, Riesemeier H, Weidemann G (2004) 3D-computed tomography over four orders of magnitude of X-ray energies. In: 16th world conference on nondestructive testing, Montreal, Canada Goebbels J, Illerhaus B, Onel Y, Riesemeier H, Weidemann G (2004) 3D-computed tomography over four orders of magnitude of X-ray energies. In: 16th world conference on nondestructive testing, Montreal, Canada
50.
Zurück zum Zitat DIN (1994) DIN 4102 Teil 4 Brandverhalten von Baustoffen und Bauteilen DIN (1994) DIN 4102 Teil 4 Brandverhalten von Baustoffen und Bauteilen
Metadaten
Titel
Variation of Intumescent Coatings Revealing Different Modes of Action for Good Protection Performance
verfasst von
Michael Morys
Bernhard Illerhaus
Heinz Sturm
Bernhard Schartel
Publikationsdatum
18.01.2017
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 4/2017
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-017-0649-z

Weitere Artikel der Ausgabe 4/2017

Fire Technology 4/2017 Zur Ausgabe