Skip to main content
Erschienen in:
Buchtitelbild

2024 | OriginalPaper | Buchkapitel

Application of Circuit Model for Early Fault Detection

verfasst von : Easter Joseph, Balbir Singh Mahinder Singh, Dennis Ling Chuan Ching

Erschienen in: ICREEM 2022

Verlag: Springer Nature Singapore

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A Matlab/Simulink-based simulation study of the PV string/array is conducted that focuses on the current parameters. The paper illustrates the variation of current parameters of the PV string and PV array according to two environmental conditions: solar radiation and temperature. The photocurrent of the PV string and current output of the PV array is highly sensitive to the amount of solar radiation while both saturation and reverse saturation currents escalate with the temperature. The percentage of current output reduction is categorized into three groups which correspond to the amount of solar radiation absorbed by the PV array. The simulation results are used as the performance indicator in developing a simple fault detection algorithm.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Zhang M, Zhang Q, Zhou D, Wang L (2021) Punishment or reward? Strategies of stakeholders in the quality of photovoltaic plants based on evolutionary game analysis in China. Energy 220:119754CrossRef Zhang M, Zhang Q, Zhou D, Wang L (2021) Punishment or reward? Strategies of stakeholders in the quality of photovoltaic plants based on evolutionary game analysis in China. Energy 220:119754CrossRef
2.
Zurück zum Zitat Hussin MZ, Hamid MHA, Zain ZM, Ab Rahman R (2010) An evaluation data of solar irradiation and dry bulb temperature at Subang under Malaysian climate, 2010 Hussin MZ, Hamid MHA, Zain ZM, Ab Rahman R (2010) An evaluation data of solar irradiation and dry bulb temperature at Subang under Malaysian climate, 2010
3.
Zurück zum Zitat Kaplanis S, Kaplani E (2011) Energy performance and degradation over 20 years performance of BP c-Si PV modules. Simul Model Pract Theory 19:1201–1211, 2011/04/01 Kaplanis S, Kaplani E (2011) Energy performance and degradation over 20 years performance of BP c-Si PV modules. Simul Model Pract Theory 19:1201–1211, 2011/04/01
4.
Zurück zum Zitat Maghami M, Hizam H, Gomes C, Hajighorbani S, Rezaei N (2015) Evaluation of the 2013 Southeast Asian Haze on Solar Generation Performance. PLoS One 10:e0135118CrossRef Maghami M, Hizam H, Gomes C, Hajighorbani S, Rezaei N (2015) Evaluation of the 2013 Southeast Asian Haze on Solar Generation Performance. PLoS One 10:e0135118CrossRef
5.
Zurück zum Zitat Rahman MM, Selvaraj J, Rahim NA, Hasanuzzaman M (2018) Global modern monitoring systems for PV based power generation: a review. Renew Sustain Energy Rev 82:4142–4158CrossRef Rahman MM, Selvaraj J, Rahim NA, Hasanuzzaman M (2018) Global modern monitoring systems for PV based power generation: a review. Renew Sustain Energy Rev 82:4142–4158CrossRef
6.
Zurück zum Zitat Drews A, de Keizer AC, Beyer HG, Lorenz E, Betcke J, van Sark W et al (2007) Monitoring and remote failure detection of grid-connected PV systems based on satellite observations 81 Drews A, de Keizer AC, Beyer HG, Lorenz E, Betcke J, van Sark W et al (2007) Monitoring and remote failure detection of grid-connected PV systems based on satellite observations 81
7.
Zurück zum Zitat Harrou F, Nounou MN, Nounou HN, Madakyaru M (2015) PLS-based EWMA fault detection strategy for process monitoring. J Loss Prev Process Ind 36:108–119CrossRef Harrou F, Nounou MN, Nounou HN, Madakyaru M (2015) PLS-based EWMA fault detection strategy for process monitoring. J Loss Prev Process Ind 36:108–119CrossRef
8.
Zurück zum Zitat Chine W, Mellit A, Pavan AM, Kalogirou SA (2014) Fault detection method for grid-connected photovoltaic plants. Renew Energy 66:99–110, 2014/06/01 Chine W, Mellit A, Pavan AM, Kalogirou SA (2014) Fault detection method for grid-connected photovoltaic plants. Renew Energy 66:99–110, 2014/06/01
9.
Zurück zum Zitat Dhoke A, Sharma R, Saha T (2019) An approach for fault detection and location in solar PV systems. Solar Energy 194:197–208 11/12/2019 Dhoke A, Sharma R, Saha T (2019) An approach for fault detection and location in solar PV systems. Solar Energy 194:197–208 11/12/2019
10.
Zurück zum Zitat Davarifar M, Rabhi A, El-Hajjaji A, Dahmane M (2013) Real-time model base fault diagnosis of PV panels using statistical signal processing. Int Conf Renew Energy Res Appl (ICRERA) 2013:599–604 Davarifar M, Rabhi A, El-Hajjaji A, Dahmane M (2013) Real-time model base fault diagnosis of PV panels using statistical signal processing. Int Conf Renew Energy Res Appl (ICRERA) 2013:599–604
11.
Zurück zum Zitat Ali MH, Rabhi A, Hajjaji AE, Tina GM (2017) Real time fault detection in photovoltaic systems. Energy Procedia 111:914–923CrossRef Ali MH, Rabhi A, Hajjaji AE, Tina GM (2017) Real time fault detection in photovoltaic systems. Energy Procedia 111:914–923CrossRef
12.
Zurück zum Zitat Sun X, Chavali RVK, Alam MA (2018) Real-time monitoring and diagnosis of photovoltaic system degradation only using maximum power point—the Suns-Vmp method. Prog Photovoltaics Res Appl 27:55–66CrossRef Sun X, Chavali RVK, Alam MA (2018) Real-time monitoring and diagnosis of photovoltaic system degradation only using maximum power point—the Suns-Vmp method. Prog Photovoltaics Res Appl 27:55–66CrossRef
13.
Zurück zum Zitat Ahmad Hamdi RT (2017) Solar cell system simulation using Matlab-Simulink. Kurd J Appl Res 2:45–51 Ahmad Hamdi RT (2017) Solar cell system simulation using Matlab-Simulink. Kurd J Appl Res 2:45–51
14.
Zurück zum Zitat Yaprak D, Spielberg ET et al, A roadmap to uranium ionic liquids: anti-crystal engineering. Chem—A Eur J 6482–6493 Yaprak D, Spielberg ET et al, A roadmap to uranium ionic liquids: anti-crystal engineering. Chem—A Eur J 6482–6493
15.
Zurück zum Zitat Xu X, Wang H, Xu X, Zuo Y (2011) Method for diagnosing photovoltaic array fault in solar photovoltaic system. Asia-Pac Power Energy Eng Conf 2011:1–5 Xu X, Wang H, Xu X, Zuo Y (2011) Method for diagnosing photovoltaic array fault in solar photovoltaic system. Asia-Pac Power Energy Eng Conf 2011:1–5
16.
Zurück zum Zitat Pandiarajan N, Ramaprabha R, Muthu R (2012) Application of circuit model for photovoltaic energy conversion system. Int J Photoenergy 2012:1–14CrossRef Pandiarajan N, Ramaprabha R, Muthu R (2012) Application of circuit model for photovoltaic energy conversion system. Int J Photoenergy 2012:1–14CrossRef
17.
Zurück zum Zitat Ramabadran R, Badrilal M (2009) MATLAB based modelling and performance study of series connected SPVA under partial shaded conditions. J Sustain Dev 2:10/20 Ramabadran R, Badrilal M (2009) MATLAB based modelling and performance study of series connected SPVA under partial shaded conditions. J Sustain Dev 2:10/20
Metadaten
Titel
Application of Circuit Model for Early Fault Detection
verfasst von
Easter Joseph
Balbir Singh Mahinder Singh
Dennis Ling Chuan Ching
Copyright-Jahr
2024
Verlag
Springer Nature Singapore
DOI
https://doi.org/10.1007/978-981-99-5946-4_1