Abstract

Since the invention in 1986 atomic force microscopy (AFM) has become the most widely used scanning probe microscopy (Binnig et al. in Phys Rev Lett 56:930–933, 1986). The microscope images the interaction of forces like Van der Waals or Coulomb forces between a sample and the apex of a small tip integrated near the free end of a flexible cantilever. But as all other scanning probe techniques the AFM requires serial data acquisition and suffers therefore from a low temporal resolution. Enhancing the speed to video rate imaging makes high demands on scanner technology, control electronics and on the key feature the cantilever with integrated sharp stylus. For the cantilever probes, fundamental resonance frequencies in the MHz regime are envisaged while the force constant of a few nN/nm shall be maintained. We present different novel AFM probes with ultrashort cantilevers and integrated sharp tips for high speed AFM while focusing on widely dispersed applications and on aspects of mass fabrication.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Albrecht TR, Akamine S, Carver TE, Quate CF (1990) Microfabrication of cantilever styli for the atomic force microscope. J Vacuum Sci Technol A 8:3386–3396CrossRef Albrecht TR, Akamine S, Carver TE, Quate CF (1990) Microfabrication of cantilever styli for the atomic force microscope. J Vacuum Sci Technol A 8:3386–3396CrossRef
Zurück zum Zitat Ando T et al (2005) High speed atomic force microscopy for capturing dynamic behavior of protein molecules at work. E J Surf Sci Nanotechnol 3:384–392CrossRef Ando T et al (2005) High speed atomic force microscopy for capturing dynamic behavior of protein molecules at work. E J Surf Sci Nanotechnol 3:384–392CrossRef
Zurück zum Zitat Binnig G, Quate CF, Gerber Ch (1986) Atomic force microscopy. Phys Rev Lett 56:930–933CrossRef Binnig G, Quate CF, Gerber Ch (1986) Atomic force microscopy. Phys Rev Lett 56:930–933CrossRef
Zurück zum Zitat Brugger J, Buser RA, de Rooij NF (1992) Silicon cantilevers and tips for scanning force microscopy. Sens Actuators 34:193–200CrossRef Brugger J, Buser RA, de Rooij NF (1992) Silicon cantilevers and tips for scanning force microscopy. Sens Actuators 34:193–200CrossRef
Zurück zum Zitat Butt HJ, Jaschke M (1995) Thermal noise in atomic force microscopy. Nanotechnology 6:1–7CrossRef Butt HJ, Jaschke M (1995) Thermal noise in atomic force microscopy. Nanotechnology 6:1–7CrossRef
Zurück zum Zitat Chand A, Viani MB, Schäffer TT, Hansma PK (2000) Microfabricated small metal cantilevers with silicon tip for atomic force microscopy. J Microelectromech Syst 9(1):112–116CrossRef Chand A, Viani MB, Schäffer TT, Hansma PK (2000) Microfabricated small metal cantilevers with silicon tip for atomic force microscopy. J Microelectromech Syst 9(1):112–116CrossRef
Zurück zum Zitat Cleveland S, Manne S, Bocek D, Hansma PK (1993) A nondestructive method for determining the spring constant of cantilevers for scanning force microscopy. Rev Sci Instrum 64:403–405CrossRef Cleveland S, Manne S, Bocek D, Hansma PK (1993) A nondestructive method for determining the spring constant of cantilevers for scanning force microscopy. Rev Sci Instrum 64:403–405CrossRef
Zurück zum Zitat Cook SM, Schaffer TE, Chynoweth KM, Wigton M, Simmonds RW, Lang KM (2006) Practical implementation of dynamic methods for measuring atomic force microscope cantilever spring constants. Nanotechnology 17:2135CrossRef Cook SM, Schaffer TE, Chynoweth KM, Wigton M, Simmonds RW, Lang KM (2006) Practical implementation of dynamic methods for measuring atomic force microscope cantilever spring constants. Nanotechnology 17:2135CrossRef
Zurück zum Zitat Folch A, Wrighton S, Schmidt MA (1997) Microfabrication of ocidation-sharpened silicon tips on silicon nitride cantilevers for atomic force microscopy. J Microelectromech Syst 6:303–306CrossRef Folch A, Wrighton S, Schmidt MA (1997) Microfabrication of ocidation-sharpened silicon tips on silicon nitride cantilevers for atomic force microscopy. J Microelectromech Syst 6:303–306CrossRef
Zurück zum Zitat Hutter JL (2005) Comment of tilt of atomic force microscope cantilevers: effect on spring constant and adhesion measurements. Langmuir 21:2630–2632CrossRef Hutter JL (2005) Comment of tilt of atomic force microscope cantilevers: effect on spring constant and adhesion measurements. Langmuir 21:2630–2632CrossRef
Zurück zum Zitat Hutter JL, Bechhoefer J (1993) Calibration of atomic-force microscope tips. Rev Sci Inst 64(7):1868–1873CrossRef Hutter JL, Bechhoefer J (1993) Calibration of atomic-force microscope tips. Rev Sci Inst 64(7):1868–1873CrossRef
Zurück zum Zitat Irmer B, Simmel F, Bilck RH, Lorenz H, Kotthaus JP, Bichler M, Wegscheider W (1999) Nano-ploughed Josephson junction as on-chip radiation sources. Superlatices Nanostruct 25:785–795CrossRef Irmer B, Simmel F, Bilck RH, Lorenz H, Kotthaus JP, Bichler M, Wegscheider W (1999) Nano-ploughed Josephson junction as on-chip radiation sources. Superlatices Nanostruct 25:785–795CrossRef
Zurück zum Zitat Krause O, Lehrer C, Petersen S (2006) SPM-probe with an EBD-tip. European Patent, EP 1672648 A1 Krause O, Lehrer C, Petersen S (2006) SPM-probe with an EBD-tip. European Patent, EP 1672648 A1
Zurück zum Zitat Lübbe J, Tröger J, Torbrügge S, Bechstein R, Richter C, Kühnle A, Reichling M (2010) Achieving high effective Q-factors in ultra-high vacuum dynamic force microscopy. Meas Sci Technol 21:125501CrossRef Lübbe J, Tröger J, Torbrügge S, Bechstein R, Richter C, Kühnle A, Reichling M (2010) Achieving high effective Q-factors in ultra-high vacuum dynamic force microscopy. Meas Sci Technol 21:125501CrossRef
Zurück zum Zitat Morita S, Yamada H, Ando T (2007) Japan AFM roadmap 2006. Nanotechnology 18:1–10CrossRef Morita S, Yamada H, Ando T (2007) Japan AFM roadmap 2006. Nanotechnology 18:1–10CrossRef
Zurück zum Zitat Rogers B et al (2003) High speed tapping mode atomic force microscopy in liquid using an insulated piezoelectric cantilever. Rev Sci Instrum 74(11):4683–4686CrossRef Rogers B et al (2003) High speed tapping mode atomic force microscopy in liquid using an insulated piezoelectric cantilever. Rev Sci Instrum 74(11):4683–4686CrossRef
Zurück zum Zitat Sader JE, Larson I, Mulvaney P, White LR (1995) Method for the calibration of atomic force microscope canitlevers. Rev Sci Instrum 66(7):3789–3798CrossRef Sader JE, Larson I, Mulvaney P, White LR (1995) Method for the calibration of atomic force microscope canitlevers. Rev Sci Instrum 66(7):3789–3798CrossRef
Zurück zum Zitat Schiffmann K (1993) Investigation of fabrication parameters for the electron-beam-induced deposition of contamination tips used in atomic force microscopy. Nanotechnology 4:163CrossRef Schiffmann K (1993) Investigation of fabrication parameters for the electron-beam-induced deposition of contamination tips used in atomic force microscopy. Nanotechnology 4:163CrossRef
Zurück zum Zitat Sulzbach T, Krause O, Burri M, Detterbeck M, Irmer B, Penzkofer C (2010) “Method of manufacturing an SPM probe with a scanning tip and with an alignment aid located opposite the scanning tip” US Patent Application 20100095409 Sulzbach T, Krause O, Burri M, Detterbeck M, Irmer B, Penzkofer C (2010) “Method of manufacturing an SPM probe with a scanning tip and with an alignment aid located opposite the scanning tip” US Patent Application 20100095409
Zurück zum Zitat Tabak FC et al. (2010) MEMS-based fast scanning microscopes. Ultramicroscopy 110:599–604CrossRef Tabak FC et al. (2010) MEMS-based fast scanning microscopes. Ultramicroscopy 110:599–604CrossRef
Zurück zum Zitat The KS, Lin L (1999) Time-dependent buckling phenomena of polysilicon micro beams. Microelectr J 30:1169–1172CrossRef The KS, Lin L (1999) Time-dependent buckling phenomena of polysilicon micro beams. Microelectr J 30:1169–1172CrossRef
Zurück zum Zitat Viani M et al (1996) Small cantilevers for force spectroscopy of single molecules. J Appl Phys 86(4):2258–2262CrossRef Viani M et al (1996) Small cantilevers for force spectroscopy of single molecules. J Appl Phys 86(4):2258–2262CrossRef
Zurück zum Zitat Wendel M, Lorenz H, Kotthaus JP (1995) Sharpened electron beam deposited tips for high resolution atomic force microscope lithography and imaging. Appl Phys Lett 67:3732–3734CrossRef Wendel M, Lorenz H, Kotthaus JP (1995) Sharpened electron beam deposited tips for high resolution atomic force microscope lithography and imaging. Appl Phys Lett 67:3732–3734CrossRef
Zurück zum Zitat Ximen H, Russel P (1992) Microfabrication of AFM tips using focused ion and electron beam techniques. Ultramicroscopy 42–44:1526–1532CrossRef Ximen H, Russel P (1992) Microfabrication of AFM tips using focused ion and electron beam techniques. Ultramicroscopy 42–44:1526–1532CrossRef
Zurück zum Zitat Yagi T, Shimada Y, Ikeda T, Takamatsu O, Takimoto K, Hirai Y (1997) A new method to fabricate metal tips for scanning probe microscopy. MEMS ’97, Proceedings, IEEE., Tenth Annual International Workshop on MEMS, pp 129–134 Yagi T, Shimada Y, Ikeda T, Takamatsu O, Takimoto K, Hirai Y (1997) A new method to fabricate metal tips for scanning probe microscopy. MEMS ’97, Proceedings, IEEE., Tenth Annual International Workshop on MEMS, pp 129–134
Metadaten
Titel
Cantilever probes for high speed AFM
verfasst von
C. Richter
P. Weinzierl
W. Engl
C. Penzkofer
B. Irmer
T. Sulzbach
Publikationsdatum
01.08.2012
Verlag
Springer-Verlag
Erschienen in
Microsystem Technologies / Ausgabe 7-8/2012
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-012-1454-8

Weitere Artikel der Ausgabe 7-8/2012

Microsystem Technologies 7-8/2012 Zur Ausgabe

Neuer Inhalt