Skip to main content
Erschienen in: Microsystem Technologies 11/2018

17.05.2018 | Technical Paper

Continuous blood pressure measurement based on a neural network scheme applied with a cuffless sensor

verfasst von: Tse-Yi Tu, Paul C.-P. Chao

Erschienen in: Microsystem Technologies | Ausgabe 11/2018

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A new computation method of a back-propagation neural network (BPNNs) is designed and expected to implement continuous measurement of blood pressures (BPs) by a noninvasive, cuffless, handheld strain-type BP sensor. The sensor is successfully designed to acquire pulsation signals at the wrist artery of a subject with a readout designed of a Wheatstone bridge, amplifier, filter, and a digital signal processor. To predict BP based on the obtained pulsation signals, 22 features are extracted to compute systolic blood pressure (SBP) and diastolic blood pressure (DBP) based an established BPNN. There are 22 input neurons, 30 hidden layers and 2 output neurons in BPNN model. The inputs are presented to the pulsation signal of time domain and frequency domain and outputs are presented to SBP and DBP. Experiments are conducted to show the validness of the developed sensor and BPNN. The data show that the prediction errors are within mmHg, respectively. SBP and DBP are 1.35 ± 3.45 and 2.29 ± 3.28 mmHg, respectively. The errors of blood pressure pass the criteria for Association for the Advancement of Medical Instrumentation (AAMI) method 2 and the British Hypertension Society (BHS) Grade B.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat American National Standards Institute/Association for the Advancement of Medical Instrumentation ANSI/AAMI (2010) Human factors engineering guidelines and preferred practices for the design of medical devices. ANSI/AAMI HE-75-2010. Association for the Advancement of Medical Instrumentation, Arlington American National Standards Institute/Association for the Advancement of Medical Instrumentation ANSI/AAMI (2010) Human factors engineering guidelines and preferred practices for the design of medical devices. ANSI/AAMI HE-75-2010. Association for the Advancement of Medical Instrumentation, Arlington
Zurück zum Zitat Bramwell JC, Hill AV (1922) The velocity of the pulse wave in man. Proc R Soc Lond Philos Trans R Soc 93(652):298–306 Bramwell JC, Hill AV (1922) The velocity of the pulse wave in man. Proc R Soc Lond Philos Trans R Soc 93(652):298–306
Zurück zum Zitat Charbonnier S, Galichet S, Mauris G, Siche JP (2000) Statistical and fuzzy models of ambulatory systolic blood pressure for hypertension diagnosis. IEEE Trans Instrum Meas 49(5):998–1003CrossRef Charbonnier S, Galichet S, Mauris G, Siche JP (2000) Statistical and fuzzy models of ambulatory systolic blood pressure for hypertension diagnosis. IEEE Trans Instrum Meas 49(5):998–1003CrossRef
Zurück zum Zitat Fulton JS, McSwiney BA (1930) The pulse wave velocity and extensibility of the brachial and radial artery in man. J Physiol 69(4):386–392CrossRef Fulton JS, McSwiney BA (1930) The pulse wave velocity and extensibility of the brachial and radial artery in man. J Physiol 69(4):386–392CrossRef
Zurück zum Zitat Gao M, Cheng H-M, Sung S-H, Chen C-H, Mukkamala R (2017) Estimation of pulse transit time as a function of blood pressure using a nonlinear arterial tube-load model. IEEE Trans Biomed Eng 64(7):1524–1534CrossRef Gao M, Cheng H-M, Sung S-H, Chen C-H, Mukkamala R (2017) Estimation of pulse transit time as a function of blood pressure using a nonlinear arterial tube-load model. IEEE Trans Biomed Eng 64(7):1524–1534CrossRef
Zurück zum Zitat Huzjan R, Brkljacic B, Delic-Brkljacic D, Biocina B, Sutlic Z (2004) B-mode and color doppler ultrasound of the forearm arteries in the preoperative screening prior to coronary artery bypass grafting. Coll Antropol 28(Suppl. 2):235–241 Huzjan R, Brkljacic B, Delic-Brkljacic D, Biocina B, Sutlic Z (2004) B-mode and color doppler ultrasound of the forearm arteries in the preoperative screening prior to coronary artery bypass grafting. Coll Antropol 28(Suppl. 2):235–241
Zurück zum Zitat IEEE Standards Association (2014) IEEE standard for wearable cuffless blood pressure measuring devices. IEEE Standard 1708–2014, pp 1–38 IEEE Standards Association (2014) IEEE standard for wearable cuffless blood pressure measuring devices. IEEE Standard 1708–2014, pp 1–38
Zurück zum Zitat Kao Y-H, Tu T-Y, Chao Paul C-P, Lee Y-P, Wey C-L (2016) Optimizing a new cuffless blood pressure sensor via a solid–fluid-electric finite element model with consideration of varied mis-positionings. Microsyst Technol 22:1437–1447CrossRef Kao Y-H, Tu T-Y, Chao Paul C-P, Lee Y-P, Wey C-L (2016) Optimizing a new cuffless blood pressure sensor via a solid–fluid-electric finite element model with consideration of varied mis-positionings. Microsyst Technol 22:1437–1447CrossRef
Zurück zum Zitat Kario K, Yasui N, Yokoi H (2003) Ambulatory blood pressure monitoring for cardiovascular medicine. IEEE Eng Med Biol Mag 22(3):81–88CrossRef Kario K, Yasui N, Yokoi H (2003) Ambulatory blood pressure monitoring for cardiovascular medicine. IEEE Eng Med Biol Mag 22(3):81–88CrossRef
Zurück zum Zitat Koeppen BM, Stanton BA (2008) Berne and Levy physiology, 6th edn. Elsevier Inc., New York Koeppen BM, Stanton BA (2008) Berne and Levy physiology, 6th edn. Elsevier Inc., New York
Zurück zum Zitat Kurylyak Y, Lamonaca F, Grimaldi D (2013) A neural network-based method for continuous blood pressure estimation from a PPG signal. In: 2013 IEEE International instrumentation and measurement technology conference (I2MTC), pp 280–283 Kurylyak Y, Lamonaca F, Grimaldi D (2013) A neural network-based method for continuous blood pressure estimation from a PPG signal. In: 2013 IEEE International instrumentation and measurement technology conference (I2MTC), pp 280–283
Zurück zum Zitat Laurent S, Girerd X, Mourad JJ, Lacolley P, Beck L, Boutouyrie P, Mignot JP, Safar M (1994) Elastic modulus of the radial artery wall material is not increased in patients with essential hypertension. Arterioscler Thromb J Vasc Biol Am Heart Assoc 14(7):1223–1231 Laurent S, Girerd X, Mourad JJ, Lacolley P, Beck L, Boutouyrie P, Mignot JP, Safar M (1994) Elastic modulus of the radial artery wall material is not increased in patients with essential hypertension. Arterioscler Thromb J Vasc Biol Am Heart Assoc 14(7):1223–1231
Zurück zum Zitat O’Brien E, Petrie J, Littler W, de Swiet M, Padfield PL, O’Malley K, Jamieson M, Altman D, Bland M, Atkins N (1990) The British Hypertension Society Protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. J Hypertens 8(7):607–619CrossRef O’Brien E, Petrie J, Littler W, de Swiet M, Padfield PL, O’Malley K, Jamieson M, Altman D, Bland M, Atkins N (1990) The British Hypertension Society Protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. J Hypertens 8(7):607–619CrossRef
Zurück zum Zitat Peltokangas M, Vehkaoja A, Verho J, Mattila VM, Romsi P, Lekkala J, Oksala N (2017) Age dependence of arterial pulse wave parameters extracted from dynamic blood pressure and blood volume pulse waves. IEEE J Biomed Health Inform 21(1):142–149CrossRef Peltokangas M, Vehkaoja A, Verho J, Mattila VM, Romsi P, Lekkala J, Oksala N (2017) Age dependence of arterial pulse wave parameters extracted from dynamic blood pressure and blood volume pulse waves. IEEE J Biomed Health Inform 21(1):142–149CrossRef
Zurück zum Zitat Shin H, Min SD (2017) Feasibility study for the non-invasive blood pressure estimation based on PPG morphology: normotensive subject study. Biomed Eng Online 16(1):1–14CrossRef Shin H, Min SD (2017) Feasibility study for the non-invasive blood pressure estimation based on PPG morphology: normotensive subject study. Biomed Eng Online 16(1):1–14CrossRef
Zurück zum Zitat Wang Y-J, Chen T-Y, Tsai M-C, Wu CH (2016) Noninvasive blood pressure monitor using strain gauges, a fastening band, and a wrist elasticity model. Sens Actuators A 252:198–208CrossRef Wang Y-J, Chen T-Y, Tsai M-C, Wu CH (2016) Noninvasive blood pressure monitor using strain gauges, a fastening band, and a wrist elasticity model. Sens Actuators A 252:198–208CrossRef
Zurück zum Zitat Wu TH, Kwong EW-Y, Pang GK-H (2015) Bio-medical application on predicting systolic blood pressure using neural networks. In: 2015 IEEE first international conference on big data computing service and applications, pp 456–461 Wu TH, Kwong EW-Y, Pang GK-H (2015) Bio-medical application on predicting systolic blood pressure using neural networks. In: 2015 IEEE first international conference on big data computing service and applications, pp 456–461
Zurück zum Zitat Xu M (2002) Local measurement of the pulse wave velocity using doppler ultrasound. Dissertation, Engineering in Electrical Engineering and Computer Science, Massachusetts Institute of Technology Xu M (2002) Local measurement of the pulse wave velocity using doppler ultrasound. Dissertation, Engineering in Electrical Engineering and Computer Science, Massachusetts Institute of Technology
Metadaten
Titel
Continuous blood pressure measurement based on a neural network scheme applied with a cuffless sensor
verfasst von
Tse-Yi Tu
Paul C.-P. Chao
Publikationsdatum
17.05.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Microsystem Technologies / Ausgabe 11/2018
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-018-3957-4

Weitere Artikel der Ausgabe 11/2018

Microsystem Technologies 11/2018 Zur Ausgabe

Neuer Inhalt