Skip to main content
Erschienen in: Microsystem Technologies 8/2017

07.07.2016 | Technical Paper

Design and experiment of a PDMS-based PCR chip with reusable heater of optimized electrode

verfasst von: Feng Cui, Wei Chen, Xiaosheng Wu, Zhaoxin Guo, Wu Liu, Weiping Zhang, Wenyuan Chen

Erschienen in: Microsystem Technologies | Ausgabe 8/2017

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A low-cost separable PCR chip, consisting of a reusable electrode part and a disposable PDMS-glass bonded chamber part, is presented. To achieve spatial uniformity of temperature over the whole reactive chamber, the heater of the electrode part with optimized electrode patterns based on traditional serpentine meanders was designed and simulated by using COMSOL Multiphysics. The separable PCR chip was fabricated using MEMS fabrication method. A temperature control thermal cycler system based on ARM microcontroller employing fuzzy-PID algorithm was constructed to provide the PCR required temperatures of denaturation, annealing and extension of each cycle. A thermal infrared imager was used to test the temperature distribution of the fabricated PCR chip. The temperature field simulation and infrared imager test verified that the heater with optimized electrode pattern can provide uniform temperature distribution in the area of the chamber where horizontal temperature fluctuation was within 1 °C. The performances of the microchip and the temperature control system were verified by β-actin gene PCR experiment. The 239 bp DNA segment of 6 μL sample in the micro-PCR chip was successfully amplified similarly to that in the conventional PCR instrument. The experiment proves that the fabricated PCR chip employing reusable heater of optimized electrode can provide efficient DNA amplification product while with less total time than the conventional PCR device. Multiple separable PCR chips with its reusable electrodes part employing the multi-channel thermal cycler system will be feasible for multiple DNA amplification.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Caputo D, de Cesare G, Nardini M, Nascetti A, Scipinotti R (2012) Monitoring of temperature distribution in a thin film heater by an array of a-Si: H temperature sensors. IEEE Sens J 12(5):1209–1213. doi:10.1109/JSEN.2011.2167506 CrossRef Caputo D, de Cesare G, Nardini M, Nascetti A, Scipinotti R (2012) Monitoring of temperature distribution in a thin film heater by an array of a-Si: H temperature sensors. IEEE Sens J 12(5):1209–1213. doi:10.​1109/​JSEN.​2011.​2167506 CrossRef
Zurück zum Zitat El-Ali J, Perch-Nielsen IR, Poulsen CR, Bang DD, Telleman P, Wolff A (2004) Simulation and experimental validation of a SU-8 based PCR thermocycler chip with integrated heaters and temperature sensor. Sens Actuators A 110(1):3–10. doi:10.1016/j.sna.2003.09.022 CrossRef El-Ali J, Perch-Nielsen IR, Poulsen CR, Bang DD, Telleman P, Wolff A (2004) Simulation and experimental validation of a SU-8 based PCR thermocycler chip with integrated heaters and temperature sensor. Sens Actuators A 110(1):3–10. doi:10.​1016/​j.​sna.​2003.​09.​022 CrossRef
Zurück zum Zitat Han D, Jang YC, Oh SN, Chand R, Lim KT, Kim KI, Kim YS (2014) MCU based real-time temperature control system for universal microfluidic PCR chip. Microsyst Technol 20(3):471–476. doi:10.1007/s00542-013-1970-1 CrossRef Han D, Jang YC, Oh SN, Chand R, Lim KT, Kim KI, Kim YS (2014) MCU based real-time temperature control system for universal microfluidic PCR chip. Microsyst Technol 20(3):471–476. doi:10.​1007/​s00542-013-1970-1 CrossRef
Zurück zum Zitat Liao CS, Lee GB, Wu JJ, Chang CC, Hsieh TM, Huang FC, Luo CH (2005) Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases. Biosens Bioelectron 20(7):1341–1348. doi:10.1016/j.bios.2004.05.006 CrossRef Liao CS, Lee GB, Wu JJ, Chang CC, Hsieh TM, Huang FC, Luo CH (2005) Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases. Biosens Bioelectron 20(7):1341–1348. doi:10.​1016/​j.​bios.​2004.​05.​006 CrossRef
Zurück zum Zitat Liu HB, Gong HQ, Ramalingam N, Jiang Y, Dai CC, Hui KM (2007) Micro air bubble formation and its control during polymerase chain reaction (PCR) in polydimethylsiloxane (PDMS) microreactors. J Micromech Microeng 17(10):2055–2064. doi:10.1088/0960-1317/17/10/018 CrossRef Liu HB, Gong HQ, Ramalingam N, Jiang Y, Dai CC, Hui KM (2007) Micro air bubble formation and its control during polymerase chain reaction (PCR) in polydimethylsiloxane (PDMS) microreactors. J Micromech Microeng 17(10):2055–2064. doi:10.​1088/​0960-1317/​17/​10/​018 CrossRef
Zurück zum Zitat Nath P, Maity TS, Pettersson F, Resnick J, Kunde Y, Kraus N, Castano N (2014) Polymerase chain reaction compatibility of adhesive transfer tape based microfluidic platforms. Microsyst Technol 20(6):1187–1193CrossRef Nath P, Maity TS, Pettersson F, Resnick J, Kunde Y, Kraus N, Castano N (2014) Polymerase chain reaction compatibility of adhesive transfer tape based microfluidic platforms. Microsyst Technol 20(6):1187–1193CrossRef
Zurück zum Zitat Phaneuf CR, Pak N, Saunders DC, Holst GL, Birjiniuk J, Nagpal N, Forest CR (2015) Thermally multiplexed polymerase chain reaction. Biomicrofluidics 9(4):044117. doi:10.1063/1.4928486 CrossRef Phaneuf CR, Pak N, Saunders DC, Holst GL, Birjiniuk J, Nagpal N, Forest CR (2015) Thermally multiplexed polymerase chain reaction. Biomicrofluidics 9(4):044117. doi:10.​1063/​1.​4928486 CrossRef
Zurück zum Zitat Saiki RK, Gelfand DH, Stoffel S, Scharf SJ, Higuchi R, Horn GT, Erlich HA (1988) Primer-directed enzymatic amplification of DNA with a thermostable DNA polymerase. Science 239(4839):487–491. doi:10.1126/science.2448875 CrossRef Saiki RK, Gelfand DH, Stoffel S, Scharf SJ, Higuchi R, Horn GT, Erlich HA (1988) Primer-directed enzymatic amplification of DNA with a thermostable DNA polymerase. Science 239(4839):487–491. doi:10.​1126/​science.​2448875 CrossRef
Zurück zum Zitat Scorzoni A, Tavernelli M, Placidi P, Valigi P, Caputo D, de Cesare G, Nascetti A (2014) Thermal characterization of a thin film heater on glass substrate for lab-on-chip applications. In: 2014 IEEE international proceedings on instrumentation and measurement technology conference (I2MTC), pp 1089–1094. doi:10.1109/I2MTC.2014.6860910 Scorzoni A, Tavernelli M, Placidi P, Valigi P, Caputo D, de Cesare G, Nascetti A (2014) Thermal characterization of a thin film heater on glass substrate for lab-on-chip applications. In: 2014 IEEE international proceedings on instrumentation and measurement technology conference (I2MTC), pp 1089–1094. doi:10.​1109/​I2MTC.​2014.​6860910
Zurück zum Zitat Scorzoni A, Caputo D, Petrucci G, Placidi P, Zampolli S, de Cesare G, Nascetti A (2015) Design and experimental characterization of thin film heaters on glass substrate for lab-on-chip applications. Sens Actuators A 229:203–210. doi:10.1016/j.sna.2015.03.011 CrossRef Scorzoni A, Caputo D, Petrucci G, Placidi P, Zampolli S, de Cesare G, Nascetti A (2015) Design and experimental characterization of thin film heaters on glass substrate for lab-on-chip applications. Sens Actuators A 229:203–210. doi:10.​1016/​j.​sna.​2015.​03.​011 CrossRef
Zurück zum Zitat Zhang C, Xing D (2007) Miniaturized PCR chips for nucleic acid amplification and analysis: latest advances and future trends. Nucleic Acids Res 35(13):4223–4237. doi:10.1093/nar/gkm389 CrossRef Zhang C, Xing D (2007) Miniaturized PCR chips for nucleic acid amplification and analysis: latest advances and future trends. Nucleic Acids Res 35(13):4223–4237. doi:10.​1093/​nar/​gkm389 CrossRef
Metadaten
Titel
Design and experiment of a PDMS-based PCR chip with reusable heater of optimized electrode
verfasst von
Feng Cui
Wei Chen
Xiaosheng Wu
Zhaoxin Guo
Wu Liu
Weiping Zhang
Wenyuan Chen
Publikationsdatum
07.07.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Microsystem Technologies / Ausgabe 8/2017
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-016-3064-3

Weitere Artikel der Ausgabe 8/2017

Microsystem Technologies 8/2017 Zur Ausgabe

Neuer Inhalt